Model : CHB Series CHUNGHO C.A. CO., LTD. Head office / Factory Seowoon-Dong, Gyeyang-Gu, Incheon, Korea. com

Similar documents
Contents. 11. Preamble. 12. For the safe use. 13. Appearance. 14. Connecting the sources of electricity. 15. Caution for use before the operation.

Contents. 11. Preamble. 12. For the safe use. 13. Appearance (Body). 4. Before connecting sources of electricity. 15. Points of warning and caution.

Instruction Manual for Dust Collector

Original instructions. Operation Manual & Cautions

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

PORT700CF Portable Fume Collector

Operation Manual RANGE HOOD

Installation/Instruction Manual

1. The structure and its description

INSTRUCTION MANUAL EPH-121 CONTENTS

40E ELECTRIC FAN HEATER

BLAST-IT-ALL BUMPER BLASTER

40E ELECTRIC FAN HEATER

TYPE FSD KYOWA EXHAUST GAS SCRUBBER OPERATION MANUAL

INSTRUCTIONS MANUAL ELECTRIC COMMERCIAL GRADE PATIO COOLER

Operating Instructions

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

Part No KEMPER Filter-Master XL

Electrostatic Precipitator

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal

JT-SB116JH-G-NA JT-SB116JH-W-NA

Installation manual Mini Comfort 50 S/L 07/ V EN

user manual Model #: BLZ-WVH-42

hp Dust Collector With Vacuum Attachment

PS /2 Inch Angle Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C

JLBIHD624 60cm Cooker Hood

Centrifugal Fan Turbofan Type KT/KP

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

BATTERY POWERED BACKPACK VACUUM

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

Operating Instructions

User Manual Drywall Sander Model: BNR7231A

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

55-Gallon Dispenser Package

Requests for Care and Maintenance

INSTRUCTION- AND MAINTENANCE MANUAL FOR ELECTROMAGNETIC AIR PUMP JDK-60, JDK-80, JDK-100, JDK-120

Far-infrared Oil Heater Owner's manual

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Operation Manual (Version 1.5.1)

Bosch Split-Type Ductless Air Conditioner / Heat Pump

1. GENERAL SAFETY RULES

PUGMILL/MIXER. Instruction Manual NVS-07

Split Air Conditioner

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

MV 2. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Owner s. 18 Misting MF18W. To view

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

BAGLESS UPRIGHT VACUUM

Landis Fume Buster 3, 4 & 5 Foot

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

COOKER HOOD USER MANUAL

TOU-716 U S E R M A N U A L. Please read these user manual and warranty information carefully before use and keep them handy for future reference.

Instruction Manual JLHDA cm Cooker hood

SPLIT - TYPE ROOM AIR CONDITIONER

Hand Dryer Installation & User Manual

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

DESIGNER HOOD MODEL: EH-E9122ST(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

USE & CARE INSTRUCTIONS

Use, Care, and Installation Guide

Checking the components Safety information Operating the product Other information

Inverter Split-type Room Air Conditioner

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Owner s Guide. Powerhead Canister Vacuum Cleaner

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

Installation Instructions

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

BarAid 400. Installation and. Starting from Serial No.:

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

MV 4 MV 4 Premium. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

OPERATION INSTRUCTION

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

690 and Power Fishing Systems

Safety In Chemistry. Identified Risks and Hazards

MODEL NO. VOLTAGE AMPS EP-3A º-500º EP-5A º-750º EP-7A º-1000º

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

Barcelona Collection. Use and handling instructions Mode d emploi et d entretien Instrucciones de uso y mantenimiento

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

Operating Instructions

Ultrasonic Humidifier TALL. Product Manual

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

MARUYASU INDUSTRIES CO.,LTD.

General safety precautions English

Operating Instructions

Service Manual This Service Manual is written for the after sail service department, especially for the fix and maintenance workers.

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

BLAST-IT-ALL PRESSURE BLAST CABINET

Solutions. Fire risk under control in welding fume extraction systems

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Surgically Clean Air Inc.

Transcription:

FUME ELIMINATOR OPERATING MANUAL (DUCLEAN) Model : CHB Series CHUNGHO C.A. CO., LTD. Head office / Factory 148-90 Seowoon-Dong, Gyeyang-Gu, Incheon, Korea. T E L : 032-555-1661 FAX:032-549-8644 http://www.chca.co.kr www.duclean. com e-mail:kwk@chca.co.kr

Contents 11. P reamble. 1 2. For the safe use. 1 3. A ppearance. 1 4. Before connecting sources of electricity. 1 5. Cautions before the operation 6. Characteristic 7. Checking. 8. Cautions for use. 9. Check of fan rotating direction 1 0. Input method of 3 phase sources of electricity 11. O peration. 1 2. St op. 1 3. Discharge of dust 1 4. Replacement of filter 1 5. Regular check table 1 6. Specification 1 7. Tr oubleshooting 1 8. Warranty and aft er service.

Preamble Thank you for purchasing CHB series, the automatic welding fume dust collector. Before use, please read the directions for use to handle this product safely and properly. After reading the directions please place this document where it s convenient to refer to it anytime. Please note that we are not responsible for any accident or breakdown caused by the followings. 1.Wrong operation 2.Handling diverted from specifications and inappropriate storage 3.Modification before use 4.Act of god or fire 5.Other unavoidable external causes Specification This manual is about CHB series and if no specification is specified, it is deemed to apply to all in general. If you have any enquiries regarding the product and the manual, please contact our branch office. When a warning label was detached, contact our branch office to replace it with a new one. Please note in advance that the specification or items of outward form is subject to change for the purpose of its reform.

For the safe use Before using the product, make sure to read and be aware of the following warning and caution with care. Warning Do not inhale the following substance, Explosive substance: those found as not inhalant as a result of measuring explosiveness level, such as dust of magnesium or magnesium alloy or cutting chip, etc. Inflammable substance:gasoline, Thinner, Benzene, kerosene, paints Dust containing sparks : those arisen from high-speed cutter, Grind, welder Fire source:cigarette butt, tobacco ashes and so on Others:fluid such as water, oil, medicines As for the explosive substances, measure its explosiveness level and confirm if it can be inhaled by a dust collector before use. (About the measurement of explosiveness level, consult with us) Do not use near where fume, mist or gas of inflammable, explosive, erosive substances residue There s a risk of ignition or explosion Do not operate when the wing bolt released There s a risk of injury or burn in case of explosion Do not dust off the filter when the wing bolt released There s a risk of injury or burn in case of explosion Do not look into or lean on a detonation blast Duct Do not use with a voltage other than specified on the product. There s a risk of fire or electric shock Do not connect or detatch a power cord with a wet hand There s a risk of electric shock

Do not damage or break a power Cord. There s a risk of fire or electric shock if a power cord is damaged when a heavy thing is placed on it or it is pulled or bent with force. Warning Do not modify this machine There s a risk of fire and electric shock Do connect Earth In case of short-circuit, there s a risk of electric shock Take necessary action as follows in case of fire or dust explosion inside Promptly cut off power to the main machine Use a fire extinguisher fit for a dust collector Do not open the door until the internal temperature goes down to a normal temperature after extinguishment. Failure to do so may cause 2 nd explosion Caution Use gloves when checking or replacing Filter and parts There s a risk of injury Do not operate with an inhalant hole closed May cause ignition due to overheating In case of abnormal sound, fuming, abnormal vibration, overheating or weird smell during operation, cut off power to the main machine right away When a motor stops during operation, cut off power to the main machine right away There s a risk of electric shock At a time of inspection or maintenance/repair, cut off power to the main machine There s a risk of electric shock

Not every micro dust of the machine is an object of inhalation. Upon use, check and confirm safety of micro dust for inhalation with care Against possible dust explosion inside, prepare a fire extinguisher fit for the inhalant micro dust Appearance

Before connecting sources of electricity Connect a power cord to single phase or 3 phase sources of electricity in a following order Warning Do not use any other voltage than specified on the product Not a multiple wiring Risk of fire or electric shock Do not connect or detach sources of electricity with a wet hand Risk of electric shock Do not damage or break a power Cord. There s a risk of fire or electric shock if a power cord is damaged when a heavy thing is placed on it or it is pulled or bent with force. Connecting Earth In case of short-circuit, there s a risk of electric shock 1. Check if the specification of power source recorded on the name plate of the machine is the same as that of power source to be connected 2. Cut off the power source of switchboard or breaker to prevent an electric shock 3. Firmly fix a terminal of earth cord(green) among 4 power Cords to the earth terminal of a switchboard using a screw 4. Firmly fix a terminal of the rest power cords(r,s,t) other than earth cord into a terminal of a switchboard using a screw 5. Check the above 1~4 again and input the sources of electricity to switchboard or breaker

Cautions before the operation Warning Do not inhale the following substance, Explosive substance: those found as not inhalant as a result of measuring explosiveness level, such as dust of magnesium or magnesium alloy or cutting chip, etc. Inflammable substance:gasoline, Thinner, Benzene, kerosene, paints Dust containing sparks : those arisen from high-speed cutter, Grind, welder Fire source:cigarette butt, tobacco ashes and so on Others:fluid such as water, oil, medicines As for the explosive substances, measure its explosiveness level and confirm if it can be inhaled by a dust collector before use. (About the measurement of explosiveness level, consult with us) Do not use near where fume, mist or gas of inflammable, explosive, erosive substances residue There s a risk of ignition or explosion Do not operate with a wing bolt released There s a risk of injury or burn in case of explosion Do not dust a filter with a wing bolt of a check door released There s a risk of injury or burn in case of explosion Do not look into or lean on a detonation blast Duct Take necessary action as follows in case of fire or dust explosion inside Promptly cut off power to the main machine Use a fire extinguisher fit for a dust collector Do not open the door until the internal temperature goes down to a normal temperature after extinguishment. Failure to do so may cause 2 nd explosion

Caution In case of abnormal sound, fuming, abnormal vibration, overheating or weird smell during operation, cut off power to the main machine right away When a motor stops during operation, cut off power to the main machine right away There s a risk of electric shock At a time of inspection or maintenance/repair, cut off power to the main machine There s a risk of electric shock Characteristic 1. CHB series is portable type, and has a strong Turbo blower which can be inhaled fume and smoke. Fume and smoke sucked in can be filtered a flowing-in flame and thick particles through 1 st Filter(Demist filter), and can be perfectly collected a minute fume and dust over 99,99% through Washable1 st Filter(Demist filter 2. Washable1 st Filter(Demist filter) is economical, and 1 st Filter(Demist filter) is easy to replacement. 3. 1 st Filter(Demist filter) can be collected 99.99% of 0.3micro meter. 4. This type has a Flexible Arm Hood which can be approached for collecting dust and fume, and Flexible Arm has four angles, and can be available 360 degree revolution. 5. Available to move and use a small space by attaching Caster.

Checking 1. 1 st Filter(Demist filter), Open the upper door(in case of Hatch type), and Pull out 1 st filter(pre-filter), and then Clean a accumulated dust with Air Blow at the opposite side of inhalation direction. In case the accumulated dust doesn t brush off, wash it with water by using the neutral detergent, and use after drying a filter. 2. Main filter(hepa FILTER) Open the upper door, and pull out the main filter toward the upper direction. In case there are damages and accumulated dust of 50% over, replace the filter. Cautions for use 1 Install this dust collector indoors 2 Supply the sources of electricity marked in the specification table 3 Use the 4-core cabtyre cord as a power cord and earth a green coated wire for earth conductor 4 In case the Fan rotating direction is the reverse when the power is supplied, link the two lines of three lines except the earth conductor line, and run it 5 Don t inhale of water or oil. Check of Fan rotating direction In case of changing the connection of power upon initial operation or movement, check the fan s rotating direction in the following order and use in a right rotating direction. 1. Press ON on the surface of a panel board Fan Motor and Fan starts rotating 2. Press OFF on the surface of an electric field box 3. If Fan rotates slowly, check the rotating direction of a motor at the upper part of a main body. If a Motor rotates in a direction of an arrow, it s okay If it reverse-rotates, change the input line of 3-phase sources of electricity

Input method of 3-phase sources of electricity 1. Cut off power supplied to the machine to avoid any electric shock 2. Detach any 2 power cords except Earth cable from the terminal of switchboard 3. Connect detached 2 power cords after changing the terminal of a switchboard Fix power cord firmly to a switchboard by a screw 4. Input sources of electricity to the machine 5. Check if the rotating direction is normal according to the above Fan rotating direction Operation Input power to the main machine and press ON Stop Press OFF ON-OFF possible at a long distance with a Remote Control Install a long distance Switch separately (Check the terminal plate)

Discharge of dust Discharge dust collected in Demist filter and HEPA filter by brushing off Accumulated dust in Basket may cause fire or explosion 1. Press OFF to stop operation 2. Discharge Dust after the machine has completely stopped 3. Release a wing bolt of the upper cover door and open the door 4. Bush off a dust attached in Demist filter and HEPA filter. 5. Install a filter properly as per the reverse order of the above

Replacement of filter Caution Use gloves when checking or replacing Filter and parts There s a risk of injury Replace a Filter every 1~1.5 years. When a damage or breakdown is found at a time of inspection, replace it with a new one right away. Use the anti-electrostatic filter only. After replacement, check if neutralizing filter sends an electric current to the main body prior to use Requirements Replace a filter in consideration of the followings Failure to do so may cause trouble, malfunction or breakdown of a product - Do not operate without a filter - Fix the Filter firmly using wing nuts - Replace Filters all at the same time. A partial replacement may accelerate filter clogging 1) Open the upper door after release a ring. (Please note to handle Duct hose attached the Flexible arm, there may be risk of accident by swing the Flexible arm when you open the upper door) 2) After opening a Hatch cover, pull up the Demist filter toward the upper direction.. 3) After separating a Demist filter, pull up the HEPA filter toward the upper direction 4) Check out the Demist filter and HEPA filter. 5) Replace the parts (filters) in case there are breakage. 6) When replacing a filter, check the condition of Packing2 and change it too if necessary

Regular check table Check Check frequency items Everyday 1 week 1 month 1 year Method and description hood, connection duct/hose O 1. Check the installed condition. If it s not good, install it correctly 2. Check damage or transformation. If any, repair or replace it 3. Check any accumulated dust in dust/hose or hood. If any, adjust pipe to remove dust or prevent its accumulation Filter O 1. Open the check door and check the installed condition. If it s not good, install it again correctly 2. Open the inspection door and check any damage or contamination. If the dust still doesn t fall off, replace the filter with a new one Power cord O 1. Check if the power cord is old or damaged. If covering is damaged and reveals the inner cable, stop using it immediately and replace it with a new one Dust leakage from O 1. Check dust leakage from ventilation port. If any, check out the installation of a filter and replace it ventilation port Dust in filter O 1. Check the state of accumulation. Motor O 1. Repair and maintenance are required every 2~3 years. contact near branch office or shop

Specification TYPE CHB - 200 CHB - 300 CHB - 500 LENGTH (A) 770mm 770mm 770mm DIMENSION HEIGHT WIDTH (B) 670mm 670mm 670mm STANDARD (C) 750mm 790mm 826mm FILTER (D) 1050mm 1090mm 1126mm MOTOR(Kw) 1.5KW X 2P 2.2KW X 2P 3.7KW X 2P FAN MOTOR POWER SOURCE 220V 1P AC, 220V/380V 3P 60Hz 220/380V 3P AC 60Hz, 440V(Option), 50Hz FLEXIBLE ARM LENGTH / QUANTITY 2m x 1 SET 3m x 1 SET DIAMETER Ø150mm FILTRATION EFFICIENCY 99.74% 3m x 2 SET (For two people) FILTER FILTRATION SIZE SHAPE 19.3m² MEDIA TYPE CARTRIDGE VOLUME OF WIND(m³/min) 25m³/min 40m³/min 60m³/min TURBO FAN CONSTANT PRESSURE(mmAq) 230mmAq ROUGH WEIGHT (INCLUDING FILTER AND ARM) ABOUT 70kg ABOUT 74kg ABOUT 83kg * Above specifications are based on 60HZ. * Power cord (4-core cabtyre cord) 3m-long * This specification is subject to change without advance notice for the purpose of product development

Troubleshooting In case of any abnormal conditions, cut off power first for safety and check out the product. If repair is required, contact the shop where the product was purchased or any near branch office TROUBLE Cause Solution Inhalation trouble - Reverse rotating -Refer to operation directions -Pipe trouble, clogged DUCT -Check and repair pipes Dust seen in exhaust port Abnormal sound or vibration No reaction at Switch on -Damaged filter -Wrong mounting of filter -Damaged Packing -Cell Plate defect -Foreign substance attached to Blower impeller -Abrasion and damage of Blower Motor axis -Tighten Blower mounting bolt -Switch defect -Motor trouble -Disconnection of power cord -Short-circuit of 2 nd electric pipe laying -Replace a filter -Mount correctly at a right angle -Replace Packing -Modify and reset -Clean impeller -Check out a filter -Replace and mount -Mount correctly -Repair and replace -Repair and replace -Replace -Check out the connecting lines S/W tripping at a time of Switch - Foreign substance attached to on Blower impeller - Clean impeller Abnormal stop -Stop by overload -Get rid of the cause AFTER SERVICE and Warranty Trouble during operation Read the manual carefully and think of inspection. However, if the machine doesn t recover still, do not repair by oneself but request for repair from our branch office

Warranty This product issues <warranty> upon request of a customer at a time of delivery The warranty period is 1 year from the date of purchase, and there are cases where gratuitous repair may not apply even during the warranty period. (such as materials subject to wear and tear, customer s liabilities) Holding period of parts The minimum holding period of functional parts of dust collector for repair use is 6 years after discontinuance of manufacturing Functional parts for repair use are parts required for maintaining the function and performance of a product In order to maintain performance and to use safely for a long term, please use our authorized parts for replacement.