Travis County Emergency Services District #1 Standard Operating Guidelines

Similar documents
2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

CARBON MONOXIDE (CO)

Model Carbon Monoxide (CO) Alarm Response Policy

Manhattan Fire Protection District

Carbon Monoxide Poisoning

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

Carbon Monoxide Alarm Response Guide. High Country Training Center Training On Demand

Frequently Asked Questions About Carbon Monoxide Detectors

Carbon Monoxide Alarm

What is carbon monoxide (CO) and why do I need a carbon monoxide detector?

Carbon Monoxide Safety Information

LOMBARD FIRE DEPARTMENT ILLINOIS CARBON MONOXIDE ALARM DETECTOR LAW. Carbon Monoxide Law. Takes effect January 1, 2007 One outside each sleeping area

From Your Building Inspector

Seriously how do you know your CO monitor is Working!

Carbon Monoxide Detection in Buildings Frequently Asked Questions

CARBON MONOXIDE DETECTOR, i4h-co-m330

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

SAFETY TIPS. From Your Building Inspector. The Sound of Safety.

Carbon Monoxide Detectors. What is carbon monoxide?

Protecting Children from Carbon Monoxide Poisoning

PROTECT YOURSELF AND YOUR FAMILY FROM THE SILENT KILLER IS YOURS INSTALLED?

Natural Gas Pipeline Safety. EDM Services, Inc. April 2009

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

LA GRANGE FIRE DEPARTMENT JANUARY 2018

The Village of Franklin Gas Safety Pamphlet

Arvada Fire Uses Advanced Gas Monitors To Keep Citizens and Responders Safe

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

Battery Powered Commercial CO Monitor

System-Connected Carbon Monoxide Detectors

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING GUIDELINE

Dutchess Community College. Emergency Action Plan. Conklin Hall College Residence

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL Models RV & RV ABOUT THIS ALARM

Structural Firefighting Policy

HOLLY HILL FIRE DEPARTMENT

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

OWNER'S MANUAL PLEASE READ AND SAVE!

I. It shall be the responsibility of the department officers to implement this operating guideline.

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Models & ABOUT THIS ALARM

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

C8600A CO Alarm OWNER S GUIDE RESIDENTIAL USE ONLY

OAK GROVE SCHOOL DISTRICT SCHOOL SITE FIRE PREVENTION PLAN

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

Commercial Carbon Monoxide Detector Owner s Manual

University of Maryland FIRE EVACUATION PLAN

carbon monoxide Preventing carbon monoxide poisoning in your home

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL 65 Series Surface Mount Models: , R, MS, R-MS

TEXAS A&M UNIVERSITY EMERGENCY MANAGEMENT. Home Safety. Smoke Alarms

can quickly rise to dangerous levels

2010 Fire Log Fire Log. Annual Fire Safety Report

FIRE PREVENTION AND SAFETY IN THE HOME. Provided to You by Lawrence Laviolette CD Fire Safety Officer

Carbon Monoxide Alarm Owner s Manual

This About Your House answers often-asked questions about carbon monoxide to help you make the right decision to make your home safe.

Home Heating MORE THAN JUST STAYING WARM

Frequently Asked Carbon Monoxide Questions

Travis County Emergency Services District #1 Standard Operating Guidelines

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

St. Vincent s Health System Page 1 of 6

Contents

RV Safety Alarms Education Test

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

Outline. Standards of Coverage. ICS Features 2/12/2016 ICS

READY, SET, PREVENT YOUR PERSONAL SUN CITY FIRE PREVENTION GUIDE. Georgetown Fire Department

Austin Independent School District Police Department Policy and Procedure Manual

Carbon Monoxide Room Alarm Installation and User Guide Part No:

OWNER S MANUAL for Models:

Carbon monoxide Knowing more

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Office of the Fire Commissioner

Department of School Safety and Security MONTGOMERY COUNTY PUBLIC SCHOOLS Rockville, Maryland

UNIVERSITY OF WEST GEORGIA Crisis Management Plan. Prepare. Respond. Recover.

Guidelines for the Design Engineer

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Screen for carbon monoxide poisoning instantly to help safeguard your staff with the ToxCO range

about your house Carbon Monoxide

Introductions HERS Industry HERS Ratings ACCA Standard 12 Resources

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

C0-210 Carbon Monoxide Probe

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

Installation and User Guide

Travis County Emergency Services District #1 Standard Operating Guidelines

STANDARD OPERATING PROCEDURES RESPONDING TO EMERGENCIES DEPARTMENT RESPONSE PROCEDURES EFFECTIVE: AUGUST 2007

Emergency Action Plan

Carbon Monoxide and Gasoline Powered Smoke Blowers STRATEGIC MANAGEMENT OF CHANGE

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

GEORGIAN COLLEGE OPERATING PROCEDURES & PRACTICES. Revised Responsible Procedure Date: Department: Administration Number: LOCKDOWN

EAST CLACKAMAS COUNTY S.O.G. S

Red Alarm Indicator Light

Ontario is taking another step to keep families and homes in Ontario safe by making carbon monoxide alarms mandatory in all residential homes.

a) Establishment of emergency procedures to be followed at the time of an emergency;

Notes From the Commish

USER S INFORMATION MANUAL

Carbon Monoxide: The High Cost and Affects of Complacency

BROWNSVILLE VOLUNTEER FIRE DEPARTMENT

TACTICAL GUIDELINES. To provide guidelines to aid the decision making process for personnel during emergency/nonemergency

NATURAL GAS SAFETY. Your safety. Our priority Update

Transcription:

PURPOSE CARBON MONOXIDE To establish a procedure for response to carbon monoxide (CO) incidents, to insure the safety of both the firefighters and the public, and to allow for safe incident mitigation. GENERAL OSHA/EPA TCESD1 Carbon monoxide is an odorless, colorless, tasteless non-irritating gas that is deadly. It is a byproduct of a fuel-burning process that has resulted in incomplete combustion. Many appliances (such as furnaces, kitchen stoves/ranges, water heaters, etc., including vehicles) can produce carbon monoxide and, when faulty or unusual conditions exist, carbon monoxide gas may be vented into areas where people are present. It enters the body by respiration and is transferred via the lungs by bonding with blood hemoglobin that reduces the body s ability to carry oxygen to vital organs. Carbon monoxide poisoning may be difficult to diagnose. Its symptoms mimic the flu, which may include headache, nausea, fatigue and dizzy spells, and more seriously, seizures and unconsciousness. The Occupational Safety and Health Administration (OSHA) has established a Time Weighted Average (TWA) Final Rule Limit for CO at 35 ppm (parts per million). The NIOSH 8-hour limit is 35 ppm. The U.S. Environmental Protection Agency (EPA) has established that residential levels are not to exceed 9 ppm over an 8-hour period. Any levels above these are considered harmful. The Fire Department is responsible only for investigating a reported carbon monoxide problem or a detector sounding, to attempt to identify and locate possible sources and clear the emergency, which may require shutting off gas at the appliance or the meter (whichever is necessary) or eliminating the hazards by other means of alternatives available. WE ARE NOT THERE TO REPAIR THE PROBLEM! We are to render emergency medical care (if applicable), to SOG B7 Version Date: 3/06/2015 Page 1 of 6

advise the occupants of our findings, and to assist occupants in exiting the structure if necessary. DISPATCH/COMMUNICATIONS OPERATORS Dispatchers are to attempt to determine whether anyone is symptomatic or feeling ill. Again, symptoms of carbon monoxide poisoning include flu-like symptoms, headaches, dizziness, lightheadedness, nausea, seizures, and unconsciousness. Complaints of not feeling well or feeling different than usual qualify as being symptomatic. If anyone is symptomatic, dispatch a Med Unit and Engine informing fire personnel of such an occurrence, that an alarm is sounding and persons are complaining of carbon monoxide symptoms. If an alarm only is sounding, advise occupants they should exit the premises to a safe place. Dispatch fire personnel accordingly, advising that only a detector is sounding and that no complaints of illness are present. ENGINE COMPANY AND EMS 1. Establish scene control as per incident command procedures. 2. Full turnout gear and SCBA shall be worn until determined otherwise by Incident Command. 3. The primary concern is the safety of our personnel and citizens. 4. The first priority after arrival of personnel is to determine if there are any illnesses related to the incident. If there are complaints or suspected complaints reported or found after arrival, a Med Unit will be requested and initial care of the injured/ill begun prior to any investigation for carbon monoxide. 5. Once medical aid is provided to victims according to established EMS protocol, the Engine Company will proceed according to the following guidelines: a. Verify if the alarm is coming from a carbon monoxide detector or a smoke detector. The cause of the alarm may be determined to be a true alarm, low battery indication, poor location of device, etc., and should be repeated to dispatch as soon as possible in the form of updating the size-up report as related to the Incident Command structuring. SOG B7 Version Date: 3/06/2015 Page 2 of 6

b. If the alarm is determined to be a smoke detector: i. Investigate the cause of the alarm. ii. Take necessary action to mitigate the situation. iii. Advise dispatch of the situation and call for additional resources as necessary. c. If the alarm is a carbon monoxide detector: i. Determine if anyone exhibits any symptoms of carbon monoxide poisoning; if so, immediately evacuate and ventilate the premises. ii. If no one exhibits or complains of any symptoms it will not be necessary to evacuate or ventilate the premises unless a level of over 9 ppm is detected by metering equipment as outlined later. d. The Officer in Charge/Incident Commander may request that the gas company respond to the scene at any time they feel is necessary to assist with checking for leaks and shutting off gas. e. The Gas Company will conduct a leak check at various locations in the occupancy to determine if there is a problem related to gas company equipment. If a problem is found, the Gas Company will shut off the gas and will advise the occupant of repairs that are needed before gas service can be restored. The gas company will make repairs unless they determine a problem exists on their equipment only (gas meter or backward to the service line). CARBON MONOXIDE INVESTIGATIONS (PROCEDURES) 1. Full turnout gear and SCBA shall be worn until determined otherwise by Incident Command. All personnel shall make complete use of personal protective equipment (PPE) and SCBAs in any atmosphere that is in excess of 35 ppm in any occupancy unless the Officer in Charge or Incident Commander deems the equipment necessary at lesser concentrations. 2. Zero the meter/monitoring device in fresh air and complete all other start-up procedures as per manufacturer s instructions of the device being used. 3. Initiate a survey of the premises to determine if there are any amounts above OSHA standards (35 ppm for business occupancy) or EPA standards (9 PPM). Remember to take initial reading just inside the entry point (i.e., front door, back door, garage entry, etc.). SOG B7 Version Date: 3/06/2015 Page 3 of 6

4. Proceed with a systematic search and survey of occupancy. 5. Readings of 9 ppm or less: a. Inform the occupants that our instruments did not detect an elevated level at this time but a concentration was noted and where it was found. b. Recommend occupants to check their CO detector per manufacturer s recommendations. c. Attempt to reset the detector. d. Inform occupants that if it activates again, CALL 911. 6. Readings of more than 9 ppm but less than 50 ppm: a. Any reading above 9 ppm will be considered an abnormal reading. b. Occupants shall be informed that we have detected a potentially dangerous level of CO. c. Recommend that all persons leave the premises and we shall begin ventilation procedures and continue checking for possible sources. Try not to ventilate any unchecked area. It may be necessary to hold ventilation for a short time to prevent ventilating an unchecked area. d. If it is determined that an appliance is malfunctioning and thereby producing CO, it shall be shut down by whatever means necessary. The occupant shall be informed of the action that has taken place and that repairs need to be made and the appliance retested by a repair service to ensure safe operation. e. Once the CO has been reduced to a safer level for the occupancy, an attempt shall be made to reset the detector. If levels are still safe the premises may be reoccupied - at the discretion of the occupant. f. Inform the occupant that if the alarm activates again CALL 911. g. If a source for CO cannot be located, occupants shall be informed of the situation and advised to contact various repair services as may be needed to conduct specific testing of appliances and equipment in order to locate and make needed repairs. SOG B7 Version Date: 3/06/2015 Page 4 of 6

7. Readings of 50 ppm or greater: a. With any readings of 50 ppm or greater, inform the occupants that we have detected a potentially lethal level of CO. b. Advise the occupants that they should evacuate the premises immediately and we will begin ventilation procedures. RECOMMEND: ONCE THE CARBON MONOXIDE LEVEL HAS BEEN REDUCED TO A SAFER LEVEL FOR THE OCCUPANT, THE PREMISES MAY BE OCCUPIED AT DISCRETION, BUT DUE TO THE LETHAL LEVELS THAT OCCURRED, THEY SHOULD CONSIDER NOT RETURNING UNTIL SOURCE PROBLEM HAS BEEN REPAIRED. c. If it is determined that an appliance is malfunctioning and thereby producing CO, it shall be shut down by whatever means necessary. The occupant shall be informed of the action that has taken place and that repairs need to be made and the appliance retested by a repair service to ensure safe operation. d. Once the CO has been reduced to a safer level for the occupancy, an attempt shall be made to reset the detector. If levels are still safe the premises may be reoccupied - at the discretion of the occupant. e. Inform the occupant that if the detector activates again to CALL 911. f. Remind the residents that potentially lethal levels of CO were found in the property and that your actions only reduced the existing level of CO gas. Also, be sure the resident understands that the source of the CO was or was not determined and that the malfunction was not corrected g. If a source for CO cannot be located, immediately notify the Gas Company and have all gas shut off to the premises. Once gas service has been shut off, it cannot be turned on for service until the source can be located and repaired by qualified technicians. SOG B7 Version Date: 3/06/2015 Page 5 of 6

MONITORING EQUIPMENT 1. All devices should be maintained per manufacturers specs. It is recommended that all monitors be calibrated by a certified technician at least quarterly or as the manufacturer recommends. 2. Monitoring equipment shall be included in all daily equipment checks. 3. All personnel should receive periodic training on the use and care of the monitoring equipment. 4. Monitoring equipment is to be carried on the first out engine and stored in its proper container or self-storage charging unit when not in use. SOG Revision Record Version Number Date Reason for Revision 1 3/6/2015 Document Release SOG B7 Version Date: 3/06/2015 Page 6 of 6