NEMA Applications Guide

Similar documents
NEMA Standards Publication. Guide for Proper Use of Smoke Detectors in Duct Applications

NEMA Standards Publication SB Fire Service Annunciator and Interface

American National Standard for Electrical Lamp Bases Specifications for Bases (Caps) for Electric Lamps

Compatibility between Smoke Alarms and Arc-Fault Circuit Interrupters

NEMA Standards Publication ICS (R 2007) Adjustable Speed Electrical Power Drive Systems

NEMA Standards Publication Temporal Light Artifacts: Test Methods and Guidance for Acceptance Criteria

NEMA Enclosures for Electrical Equipment (1000 Volts Maximum)

American National Standard. for Roadway and Area Lighting Equipment Solid State Light Sources Used in Roadway and Area Lighting ANSI C136.

American National Standard for Electrical Intermediate Metal Conduit

For Roadway and Area Lighting Equipment Ingress Protection (Resistance to Dust, Solid Objects, and Moisture) for Luminaire Enclosures

NEMA Standards Publication Enclosures for Electrical Equipment (1000 Volts Maximum)

NEMA Standards Publication WC High-Temperature and Electronic Insulated Wire, Impulse Dielectric Testing

American National Standard for Roadway and Area Lighting Equipment Induction Lighting

American National Standard for Roadway and Area Lighting Equipment Elliptically Shaped, Enclosed Side-Mounted Luminaires

ANSI C Revision of ANSI C National Electrical Manufacturers Association. American National Standards Institute, Inc.

American National Standard. for Roadway and Area Lighting Equipment Solar Lighting Systems ANSI C Secretariat:

Insulated High Temperature Hook-Up Wire; Types ET (250 Volts), E (600 Volts), and EE (1000 Volts)

American National Standard for Roadway and Area Lighting Equipment Plasma Lighting

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

NEMA Standards Publication WC Standard for Controlled Impedance Shielded Twisted Pairs in Internal Electrical Cable

American National Standard for Portable Lithium Primary Cells and Batteries Safety Standard

ANSI/NEMA HP Approved as an American National Standard ANSI Approval Date: April 15, Published by:

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

ANSI/IEC American National Standard for Arc Welding Equipment Part 2: Liquid Cooling Systems

NEMA Enclosures for Electrical Equipment (1000 Volts Maximum)

American National Standard

Errata ANSI Z223.1 National Fuel Gas Code 2015 Edition

2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14

NEMA SB Applications Guide Carbon Monoxide Alarms and Detectors

NEMA Standards Publication WC Standard for Controlled Impedance in Internal Electrical Cable

American National Standard for Requirements for Watthour Meter Sockets

Overview of Standards for CO Detection Products

Life Safety Code Comparison

American National Standard

Report on First Revision June 2014 NFPA 5000

American National Standard for Product Safety Information in Product Manuals, Instructions and Other Collateral Materials

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa

Carbon Monoxide Detection in Buildings Frequently Asked Questions

DIVISION C ADMINISTRATIVE PROVISIONS

NFPA Overview. International Titanium 2014 Conference Chicago Kevin L. Kreitman

Personal Emergency Response (PERS) Verification and Notification Procedures

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

FIRE & LIFE SAFTEY STANDARD

Management Practices: Fire Protection Impairments November 2015

2019 COURSE CATALOG (rev )

INTERNATIONAL STANDARD

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

NFPA 72 Code Changes vs 2013

Florida Senate SB 982 By Senator Bennett

home smoke candles alarms electrical burns smoking medical oxygen cooking FIREFIGHTING MATCHES & LIGHTERS SPRINKLERS

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

INTERNATIONAL STANDARD

PLUGS, RECEPTACLES, AND CONNECTORS OF THE PIN AND SLEEVE TYPE FOR HAZARDOUS LOCATIONS

This document is a preview generated by EVS

American National Standard for Safety Tags and Barricade Tapes (for Temporary Hazards)

REQUIREMENTS. For FIRE DEPARTMENTS. State of West Virginia. Bob Wise Governor THE DEPARTMENT OF MILITARY AFFAIRS AND PUBLIC SAFETY

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2007 SESSION LAW SENATE BILL 1924

TECHNICAL REPORT IEC/TR

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

Carbon Monoxide Detectors in New and Existing Buildings

This is a preview - click here to buy the full publication

ICC 902/ APSP 902/ SRCC Solar Pool and Spa Heating System Standard

This section shall take effect on June 27, 2015 and transition period effective date of this section and June 27, 2016

BOARD OF EXAMINERS OF LANDSCAPE ARCHITECTS

Fire Alarm Inspection, Testing, Maintenance. Assuring the System s Operational Reliability

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Slide 1. Slide 2 Instructor. Slide 3. NFPA 25 The Owner s Manual. Roles & Responsibilities DISCLAIMER

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

GS-12 GREEN SEAL STANDARD FOR OCCUPANCY SENSORS FIRST EDITION FEBRUARY 14, 1997

INTERNATIONAL STANDARD

BS 8418: 2015 Installation and remote monitoring of detector-activated CCTV systems Code of practice

Rutgers Environmental Health and Safety (REHS)

ENGINEERING EVALUATION

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPA DOCUMENTS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA DOCUMENTS

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

SANS :2014 Edition 1 IEC :2012 Edition 1

Recent Revisions and Proposed Key Changes to Fire Code

Guidelines for designating and monitoring notified bodies in Norway

British Columbia Landscape Standard. Published by:

Audio Verification and Notification Procedures

INTERNATIONAL STANDARD

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

CAMDEN COUNTY FIRE COORDINATOR

ISO 6183 INTERNATIONAL STANDARD. Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation

Township of Woolwich. By-law No

CE marking & your legal obligations

INTERNATIONAL STANDARD

NFPA 211. Standard for Chimneys, Fireplaces, Vents, and Solid Fuel- Burning Appliances Edition

Please think twice about printing this matrix. You can it, along with your ballot to or

Medical electrical equipment

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

June 20, 2011 PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS

COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

Transcription:

Page 3 NEMA Applications Guide Carbon Monoxide Alarms and Detectors Published by National Electrical Manufacturers Association 1300 North 17 th Street, Suite 1752 Rosslyn, Virginia 22209 www.nema.org

Page 4

Page 5 NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or seller s products or services by virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safety related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement.

Page 6 Foreword The purpose of this guide is to provide information concerning the proper use of carbon monoxide (CO) alarms and detectors. The guide covers the major technologies used for the detection of CO, the differences between CO alarms and CO detectors, combination devices and CO device reliability, effectiveness and limited life. The guide was developed by NEMA s Signaling Protection and Communications Section (3-SB). Some of the material contained in the guide was extracted from NFPA 720, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment. NEMA extends its thanks to the National Fire Protection Association (NFPA) for granting permission to extract this material. About the NEMA Signaling Protection and Communications Section (3SB): The objective of the Signaling Protection and Communications Section is to be the principal source of technical, training, and educational materials essential for the specification, application and manufacture of reliable life safety products, including their installation, performance and inspection. The Section currently represents 18 manufacturers in support of the automatic fire detection and alarm industry and the health care communications industry. Fire detection and alarm products include life safety/fire alarm systems and devices that provide early warning of an impending or actual fire or gaseous hazard. The products detect, notify, and initiate control functions in case of hazard to life or property. For more information on life safety, go to www.lifesafetysolutionsonline.com. About the Association Electrical and Medical Imaging Equipment Manufacturers (NEMA): NEMA is the association of electrical and medical imaging equipment manufacturers. Founded in 1926 and headquartered near Washington, D.C., its approximately 450 member companies manufacture products used in the generation, transmission and distribution, control, and end use of electricity. These products are used in utility, industrial, commercial, institutional, and residential applications. The association s Medical Imaging & Technology Alliance (MITA) Division represents manufacturers of cutting-edge medical diagnostic imaging equipment including MRI, CT, x-ray, and ultrasound products. Worldwide sales of NEMA-scope products exceed $120 billion. In addition to its headquarters in Rosslyn, Virginia, NEMA also has offices in Beijing and Mexico City. Proposed or recommended revisions should be submitted to: Vice President, Technical Services Department National Electrical Manufacturers Association 1300 North 17th Street Suite 1752 Rosslyn, Virginia 22209

Page 7 CONTENTS FOREWORD... 6 1 SCOPE AND PURPOSE... 1 1.1. Scope... 1 1.2. Purpose... 1 2 REFERENCED STANDARDS... 1 2.1. Installation Standards... 1 2.2. Product Standards... 1 3 GLOSSARY OF TERMS... 2 4 CARBON MONOXIDE OVERVIEW... 3 4.1. What is Carbon Monoxide (CO)?... 3 4.2. Why is CO a concern?... 3 4.3. Where is CO produced/found?... 5 4.4. How can we protect against CO?... 5 4.5. Model Building Codes... 5 5 HOW CARBON MONOXIDE ALARMS AND CARBON MONOXIDE DETECTORS OPERATE.. 6 5.1. Biomimetic Sensor Operation... 6 5.2. Metal Oxide Semiconductor CO Sensor Operation... 6 5.3. Electrochemical CO Sensor Operation... 7 5.4. Limited Life of CO Sensors... 8 5.5. Operational differences between alarms and detectors... 9 5.6. Combination Smoke/CO Alarms and Combination Smoke/CO Detectors... 11 5.7. Carbon Monoxide Detection Technology Reliability and Effectiveness... 12 6 INSTALLATION AND PLACEMENT... 12 6.1. Placement and Spacing... 13 6.2. Carbon Monoxide Detectors for Control of Carbon Monoxide Spread... 13 7 INSPECTION, TESTING AND MAINTENANCE... 13 7.1. Carbon Monoxide Alarms... 14 7.2. Inspection, Testing, and Maintenance Practices of Carbon Monoxide Detection Systems... 14 7.2.1. Notification... 14 7.2.2. Visual Inspection... 14 7.2.3. Reacceptance Testing... 14 7.2.4. Functional Testing... 14 7.2.5. Chinese Drywall... 14

Page 8 8 CARBON MONOXIDE DETECTION SYSTEMS... 15 8.1. Design Considerations... 15 8.2. Distinctive Signals... 15 8.3. Types of CO Detection Systems... 15 8.4. Occupant Notification... 16 8.5. Secondary Power Requirements... 16 ANNEX A NFPA 720-2009... 17

Page 1 1 Scope and Purpose 1.1. Scope This document covers carbon monoxide (CO) detection devices including single and multiple station CO alarms and system-connected CO detectors and sensors connected to a control unit. CO detection devices used in ventilated spaces, such as enclosed parking garages, are not included under the scope of this document but are addressed by the Occupational Safety and Health Administration and the Environment Protection Agency. 1.2. Purpose The purpose of this document is to provide guidance on the proper application, installation, location, performance, inspection, testing, and maintenance of CO detection devices. It outlines basic principles, which should be considered in the application of early warning CO detection devices. Operating characteristics of devices and environmental factors, which may aid, deter, or prevent their operation, are identified. Fire protection engineers, mechanical and electrical engineers, fire service personnel, building code officials, fire alarm designers, and installers will find the contents educational. The document is based on industry expertise and many years of experience, and it is intended to be used only as a technical guide. Applicable codes and standards as well as directives of the Authorities Having Jurisdiction must be followed. 2 Referenced Standards 2.1. Installation Standards National Fire Protection Association (NFPA): NFPA 720-2009, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment: The standard covers the proper application, installation, and maintenance of CO detection. The 2009 edition of The Standard is primarily concerned with life safety, not with protection of property, public health or worker safety. It covers the selection, design, application, installation, location, performance, inspection, testing, and maintenance of CO detection and warning equipment in buildings and structures. NFPA 72-2010, National Fire Alarm and Signaling Code: The standard covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components. 2.2. Product Standards The following American National Standards Institute (ANSI) and Underwriters Laboratories (UL) ANSI/UL standards apply to CO alarms and CO detectors: National Electrical Manufacturers Association