Analyze IT. Process Gas Chromatograph. PGC2000 Series

Similar documents
Process Gas Chromatograph

Process Gas Chromatograph

931D Style B Process Gas Chromatograph

Process Gas Chromatograph

Rosemount 1500XA Process Gas Chromatograph

Rosemount 1500XA Process Gas Chromatograph

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

FPD - Flame Photometric Detector

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

OPERATION AND SERVICE MANUAL Process Gas Chromatograph PGC OSM F2: October 2008

Integrated Automation Instrumentation & Terminal Devices

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

CALIDUS tm the Modular micro Gas Chromatograph

Standard VistaNET GCC Software: 803V029-(VER)(REV)

GasGard 100 Control System

HFID Heated Total Hydrocarbon Analyzer Module

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Series 9000 Total Hydrocarbon Analyzer

Danfoss gas detection unit Type GD Heavy Duty

Process Gas Chromatograph

SUPREMATouch. Modular Fire & Gas Detection System

Perkin Elmer Clarus 500 Gas Chromatograph

HISTORY OF VARIAN CAPILLARY INJECTORS

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

Recent Improvements in Process GC Instrumentation

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

PUV, PIR and PFO Series BROCHURE

Recalibrate the way you look at gas detection

SUPREMATouch. Modular Fire & Gas Detection System

FIXED GAS ANALYZER (FGA)

ProStar 325 UV-Vis Detector

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Distributed By: M&M Control Service, Inc Building Technologies

Power Flame Incorporated

Chemtron Science Laboratories Pvt. Ltd.

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

ß-Aerosolmonitor FHT 59 C

VHP M100 BIODECONTAMINATION SYSTEM

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Industrial Grade Gas Detection

Industrial Grade Gas Detection Detecting The Difference

HPLC Column Ovens and Temperature Controllers

PROCESS CONTROL COURSES

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

detectors UltiMate 3000 Variable Wavelength Detectors

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Intelligent Single Loop Fire Alarm Control Panel

EC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

SUPREMATouch Modular Fire & Gas Detection System

Analog Input Module IC670ALG630

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Connected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance.

300/400 UNITS - MODULAR CONFIGURATION

Agilent GC Solutions. A Convenient Deans Switch Method for the Analysis of Permanent Gases in Various Matrices by Gas Chromatography CAG

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Airflow Sensors Line Guide

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

Flexible Air-sampling Smoke Detection

SCION 436-GC. Dimensions and Weights

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

LAUDA ECO. Precise, economical, flexible

PRODUCT LINE. Highest Quality, Best Service

Screw Compressors HSD SERIES. Capacities from: 816 to 3002 cfm Pressures from: 80 to 217 psig

Airflow Sensors Line Guide

Design Benefits and Advantages:

Advance Optima Module Magnos 17

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

Spectron LSN (Life Safety Network) Suggested Specifications

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

OMA-300 Process Analyzer

Danfoss gas detection units

July 13, Reducing False Positives When Monitoring for Low Concentrations of Airborne Organic Chemicals in the Workplace

Industrial Grade Gas Detection

Datalogging as standard

Module Features are-configurable, no module jumpers to set

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Nexis GC-2030 Specifications

PHOENIXL 300 New Standards in Leak Testing. Technical information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

VS Series. Variable Speed Rotary Screw Compressors

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Process gas chromatography

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Technical specifications of FT-IR Spectrometer

Transcription:

Process Gas Chromatograph PGC2000 Series PGC2000 Series PGC2002 Process Distillation PGC2003 PNA PGC2005 Temperature Programmed GC PGC2007 Fuel Sulfur Analyzer PGC2008 Olefins Analyzer PGC2009 Fast TP GC Analyze IT Control IT Engineer IT Field IT Inform IT Operate IT Power IT Industrial IT

PGC2000 Series Process Gas Chromatograph A Gas Chromatograph Built On A Foundation Of Leadership ABB manufactured and sold the first on-line process gas chromatograph in 1957. In the decades since, ABB has continually advanced its process GC technology leadership. Now, ABB is leading the way into the 21st Century with the PGC2000 series of process gas chromatographs. The PGC2000 is the second generation of Vista on-line process GC s. ABB PGC analyzers have set a new standard for ease of use, quality and reliability. The PGC2000 has also raised process GC technical standards, with more compact size, improved serviceability, superior connectivity and digital analytical control. A More Compact Design For Greater Space Savings The PGC2000 has a significantly smaller footprint than competitive designs. The analyzer is only 19.5 inches (496 mm) wide. For most configurations, there are no components, tubing or wiring on the left side. That saves even more space in installation. Analyzer-to-analyzer spacing has been reduced by over 19 inches (482 mm), significantly reducing the required shelter space for multi-analyzer systems. Improved Serviceability The PGC2000 uses an integrated backplane that eliminates wiring harnesses and terminal strips. All subsystems such as temperature controllers, detector amplifiers, sensors, and options are assigned specific, clearly labeled plug locations. This self-documenting concept greatly improves serviceability and upgrade ability. It also improves quality and reliability by eliminating loose wiring connections and allowing components and modules to be tested before system installation. Process Gas Chromatograph

Superior VistaNET 2.0 Connectivity Integration of the PGC2000 into the process control loop is readily achieved with the ABB VistaNET2.0 Integrated Process Analyzer Network Architecture. VistaNET 2.0 is an economical single-wire solution that enables seamless connectivity to existing Ethernet-based systems. With VistaNET 2.0 all process analytical equipment can share the same network for data exchange, with control systems and higher-level processes, in a true distributed network architecture. VistaNET 2.0 provides plant engineers, maintenance engineers and other data users with a common platform for data collection, presentation and analysis. Digital Analytical Control Functions The PGC2000 offers standard digital temperature and optional digital pressure control. With digital controls, temperature and pressure can be set directly at the analyzer keypad or remotely via VistaNET 2.0 Digital control reproduces temperature and pressure settings far more precisely than analog temperature controls or mechanical pressure regulators. The optional electronic pressure control improves chromatography by providing better resolution, exceptional retention time stability, and faster analysis time. Ambient temperature, carrier supply, and barometric pressure effects are reduced, greatly improving analyzer stability. Analytical flows can vary for different methods within the same analyzer, enabling a wider range of on-line and at-line applications. Carrier gas consumption can be minimized by turning carrier flow off when not needed and by reducing or eliminating split flows and flows to vent during portions of the analysis.

Ease Of Operation The PGC2000 Series offers a fast learning curve with minimal training. Analyzers can be placed on-line and kept on-line with a minimum amount of time spent learning the programming. The PGC2000 s menu-driven interface, front panel keypad and 5.6 inch (142 mm) diagonal graphics display allow users to easily change, modify or edit all analysis parameters. All front panel functions are also available at any network PC via VistaNET 2.0 This allows operating personnel to concentrate on the analytical aspects of the application instead of electronic/programming concerns. A World Class Analyzer Meets World Standards The PGC2000 Series is designed from the ground up to meet current and emerging international standards such as CE/CENELEC, ATEX, CSA, and NEC/NRTL. In most cases,the standard configuration meets all required international standards, minimizing analyzer variants and assuring consistent performance and safety. VistaBASIC virtually eliminates the need for a PLC in complex discrete sampling systems. VistaBASIC provides interanalyzer communications, where measurement values from one analyzer are used in calculations on another, via VistaNET 2.0 While VistaBASIC can be used for these more sophisticated analyzer solutions, BASIC programming skills are not required for typical analyzer applications. Common uses for VistaBASIC include calculated values derived from measured component valves, such as heating value (BTU). VistaBASIC provides the tools for custom extensions to the chromatograph controller s capabilities and provides full access to the extensive I/O of the Vista controller. Specialized PGC2000 Series In addition to the standard PGC2000, ABB Analytical offers several specialty process gas chromatographs: PGC2002 Process Distillation PGC2003 PNA (Paraffins, Naphthenes and Aromatics) PGC2005 Temperature Programmed GC PGC2007 Fuel Sulfur Analyzer PGC2008 Olefins Analyzer PGC2009 Fast Temperature Programmed GC for Simulated Distillation Real-Time VistaBASIC Flexibility and integration are critical to a process chromatograph. ABB s VistaBASIC language provides additional flexibility in meeting customer application requirements. Real-time VistaBASIC allows the chromatographic controller to be used in a supervisory capacity to monitor sample systems and interface with other devices in more complex remote-controlled systems.

Analytical Oven Analytical Oven Precise air bath oven temperature control Efficient oven layout Valves oriented for easy access PFA Teflon replaces SS tubing for air lines Liquid and vapor injection valves Detectors appropriate for the applications: Flame Ionization Detector Thermal Conductivity Detector Flame Photometric Detector Packed, micro-packed and capillary columns Liquid Sample Valve The field proven liquid sample valve, with wear compensating seals, is a one piece design with vaporizer and metal surface deactivation to yield longer life. Sample pressures up to 435 PSI (197.28 KPI) and temperatures up to 200 C (392 F). Continuous Performance (CP) Sliding Plate Valve Accommodates packed or capillary columns. Design includes automatic wear compensation and slider tension loading. Sample pressures up to 150 PSI (68.03 KPI) and temperatures up to 180 C (356 F). Liquid Sample Valve Continuous Performance (CP) Sliding Plate Valve

Analytical Detectors The ABB Flame Ionization Detector provides extreme sensitivity for ppm hydrocarbons and is individually heated as required by the application. Analytical-Detectors Thermal Conductivity Detector Chromatogram Storage The ABB Thermal Conductivity Detector is suited for general purpose analytical measurements, normally in the percent ranges, but may be applied to measurements down to hundreds of ppm in some applications. It may also be individually heated when required by the application. The Flame Photometric Detector is the third ABB designed detector available. It is selective for analysis of sulphur levels down to very low ppm. Technical And Performance Features Flame Photometric Detector The process gas chromatograph PGC2000 Series offers a broad range of features. Some of these features are outlined here. Chromatogram Storage Analysis may be saved on calibration, benchmark, typical, alarm, last analysis and current analysis Up to one hour of chromatograph storage is available The user can save raw chromatograms manually or automatically The operator can view the chromatogram at the Model 2000 controller or on a PC connected to VistaNET 2.0 The PGC2000 Controller Front Panel Keyboard/LCD 5.6 inch (142 mm) diagonal LCD graphic user interface 320 x 240 dot monochrome (white on blue screen) 50-key touch pad Plain language menus Digital Temperature And Pressure Controllers Temperature Standard EPC Optional Allow full visibility of all analyzer temperature and pressure settings Up to five independently-controlled zones for temperature and pressure Zones can control external sample system heaters at user s option Temperature and pressure setpoints may be varied as dictated by the analytical methods Reproduce temperature and pressure settings more precisely than analog controllers or mechanical regulators Detector Signals Design integrates two detector signals simultaneously in any combination TCD/FID, TCD/FPD, FID/FID, etc. Detector signals digitized using Voltage to Frequency conversion Converter integrates detector signal, counting a pulse 32 times per second Reading represents continuous integration of the signal over previous 1/32 of a second. Eliminates errors associated with finite sampling rates

SQC Support SQC Support access to peak area baseline noise analyzer status other data printer for hard copy reports Analog Outputs Analog trend outputs for component concentrations 32 each, 4-20 ma isolated outputs 96 each, 0-5 or 1-5 volt outputs 0-10 volt recorder output Applications Engineering ABB applications engineers pioneers and innovators are world-recognized leaders in chromatographic applications technology. Our application experience, coupled with the power of the PGC2000 Series, enables ABB to successfully apply the chromatographic technique to a broad range of process applications and achieve targeted analysis times. To discuss your specific application and receive complete information on the PGC2000 Series, please contact your ABB Representative. System Maintenance Written alarm messages Integral diagnostics Help menus Integral chromatogram display Resume On Power Interrupt feature Base Inputs 12 each, discrete stream select inputs or additional VistaBASIC inputs 4 each, discrete VistaBASIC inputs Up to 8 each, dry contact sensor inputs Remote start 2 each, 12-bit differential VistaBASIC analog inputs Serial Outputs 1 each, RS232 printer, write only DCS outputs through the VistaNET 2.0 Gateway Digital Outputs Up to 32 each, remote streams (10 each, standard) Up to 96 each, concentration alarms Other Support Functions Program supports up to 8 each, analyzer oven valves 8 each, methods 50 components Worldwide Service and Support ABB supports the PGC2000 Series and all of its analyzer products through a specialized business unit dedicated to service and support. ABB Customer Service and Support (CSS) provides installation and start-up services, commissioning and training, maintenance services, reconditioning, repair and replacement parts, and other specialized services designed to reduce the customer s cost of ownership. Maintenance services are available on an as-needed basis or through scheduled maintenance agreements. Training services are available for virtually every aspect of operating and maintaining the PGC2000. Training may be arranged on-site or at any of our training centers. With manufacturing facilities, sales and distribution units located worldwide, ABB Customer Service and Support is available wherever you need it.

BUASC1A-1-1102 Specifications subject to change without notice. ABB Inc. 843 N. Jefferson Street Lewisburg, WV 24901 USA 304-647-4358 voice 304-645-4236 fax 2002 ABB Inc. www.abb.com/analytical