Chemtron Science Laboratories Pvt. Ltd.

Similar documents
SCION 436-GC. Dimensions and Weights

PID Detector. Add-on to any GC For R&D, QC, Industrial Hygiene, and Environmental & Routine ppb Analysis. PID Model C/ PID Model C

Selecting the right generator for your GC system. By Ed Connor, GC Product Specialist, Peak Scientific Instruments Ltd

TENDER NOTICE NO. 07/2012 INVITATION FOR BIDS / NIT

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

Perkin Elmer Clarus 500 Gas Chromatograph

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Gas Chromatography (GC-342)

Chemistry Instrumental Analysis Lecture 29. Chem 4631

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Process Gas Chromatograph

Recent Improvements in Process GC Instrumentation

FIXED GAS ANALYZER (FGA)

CALIDUS tm the Modular micro Gas Chromatograph

POPULAR CONFIGURATION GCs Cryosulfur GC. System Overview

Process Gas Chromatograph

FPD - Flame Photometric Detector

Nexis GC-2030 Specifications

Aromatics and Oxygenates in Gasoline June2018

Rosemount 1500XA Process Gas Chromatograph

Rosemount 1500XA Process Gas Chromatograph

Datalogging as standard

GC Injectors. GC Injectors

DISSOLVED GAS ANALYZER (DGA)

Technical specifications of FT-IR Spectrometer

Process Gas Chromatograph

Process Gas Chromatographs MAXUM edition II

Process gas chromatography

Process Gas Chromatograph

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

intrinsically safe detector for hydrocarbon gases

Analyze IT. Process Gas Chromatograph. PGC2000 Series

931D Style B Process Gas Chromatograph

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Maintenance and Troubleshooting Manual. PN , Revision March 2011

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

Rosemount Analytical Solutions. Emerson Offshore Technology Day March 26th 2015 by Rune Damgaard, Account Manager - Measure & Analyze

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

E²M. Innovation with Integrity. Enhanced Environmental Mass Spectrometer. Safety & Security

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

TYPES AND APPROPRIATE INJECTORS

HPLC Column Ovens and Temperature Controllers

22 The Flame Ionization Detector

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Getting Started. PN , Revision May 2010

Ministerial Decree No. 14/2005 (VI. 28.) KvVM. on the rules concerning the screening surveys of remedial site investigations.

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

GC DETECTORS Reduction Gas Detector - RGD. Overview

Agilent 7890A Network Gas Chromatograph

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Process Gas Chromatograph

HISTORY OF VARIAN CAPILLARY INJECTORS

Vernier Mini GC Plus Gas Chromatograph (Order Code: GC2-MINI)

Thermo Scientific TVA2020 Introduction

HFID Heated Total Hydrocarbon Analyzer Module

Vernier Gas Chromatograph Mini GC

PRODUCT CONFORMITY CERTIFICATE

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

GAS CHROMATOGRAPHY PURDUE UNIVERSITY INSTRUMENT VAN PROJECT. DEMYSTIFICATION ACTIVITY FOR THE GAS CHROMATOGRAPH (Revised: ) INTRODUCTION

YL6500 Gas Chromatograph

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

This document is a preview generated by EVS

GAS ANALYSIS / DETECTION Gas Detector

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

NOTICE INVITING TENDERS FOR THE PURCHASE OF 1. FLASH CHROMATOGRAPHY 2. ION CHROMATOGRAPH 3. MICROWAVE MUFFLE FURNACE

1320 Detectors. 1 of 30. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

Standard Operating Procedure Gas Chromatograph Mass Spectrometry (GC/MS) - Agilent 7890B GC & 240 Ion Trap MS

Series 9000 Total Hydrocarbon Analyzer

Gas Detection - GD -

Complete Gas Analysis

Dual Cell Microvolume Thermal Conductivity Detector

Gas Technology Services

Key Performance. CompactGC 4.0

THE RIGHT CONSUMABLES FOR YOUR GC APPLICATIONS. Clarus 590/690 Gas Chromatography Consumables and Supplies Reference Guide

Vernier Gas Chromatograph Mini GC (Order Code: GC-MINI)

Mobile CWA Detection and Identification. Innovation with Integrity. Mobile Mass Spectrometer MM2 CBRNE

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

APPLICATION DATA SHEET

INJECTORS Purge & Trap General Operating Procedures continued

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

INSTRUCTION, OPERATING AND MAINTENANCE MANUAL FOR MODEL

T.ex Single Gas Detector VISA

Process Gas Chromatographs

Chromatography. Research Supplies. 2014/2015 Catalog

get mass. without massive work. [ 3100 MASS DETECTOR ]

PRODUCT CONFORMITY CERTIFICATE

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

TCD-to-FID Series Connection on a 6820 GC, Accessory G4319A

TOTALFLOW Technical Bulletin 139

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Project demonstrates benefits of traceable on-line measurement of siloxanes in industrial biogas Solving the siloxane measurement problem

Corpus Christi - Air Monitoring Project

Dräger X-am 7000 Multi-Gas Detection

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Labtronics.


Transcription:

Chemtron Science Laboratories Pvt. Ltd. To, INTRODUCTION TO CSL GAS CHROMATOGRAPHS COMPANY PROFILE Chemtron Science Laboratories Pvt. Ltd. is an ISO 9001: 2000 by BSI, a part of fastest growing industry i.e. chemical and electronics industry. Established in the year 1992 CSL has annual growth rate of 25%. We are well equipped with advanced technology lab equipments, testing and inspecting facilities, which makes our products one of the best in the industry. CSL has a team of trained qualified engineers in its R & D Department, which constantly seeks to innovate, specialized products as per customer s requirement. CSL PRODUCTS Gases Division Speciality Gas Mixture Pure Gases Gas Handling Equipment s a) Gas regulators b) Manifolds c) Sampling Bomb d) Closed/Open type sampling system Instrumentation Division Thermal Conductivity Detector Assembly Flame Ionization Gas Detector Assembly Electron Capture Detector Assembly Ultra Sensitive SF6 Leak Meter (PPT Level) Transformer Oil Gas Analyser Binary Gas Analyser Hydrocarbon Gas Analyser Supercritical CO2 Extraction Fodder Machines CSL detectors in GCs Detector Type Support gases Selectivity Detectability Flame ionization (FID) Mass flow Hydrogen and air Most organic cpds. 100 pg Thermal conductivity Concentration Reference Universal 1 ng (TCD) Helium Ionization Concentration Helium In organic Gases 50 Ppb Detector( HID) Electron capture (ECD) Concentration Make-up Halides, nitrates, nitriles, peroxides, anhydrides, organometallics 50 fg Flame photometric (FPD) Mass flow Hydrogen and air possibly oxygen Sulphur, phosphorus, tin, boron, arsenic, germanium, selenium, chromium Photo-ionization (PID) Concentration Make-up Aliphatics, aromatics, ketones, esters, aldehydes, amines, heterocyclics, organosulphurs, some organometallics 100 pg Maintenance & Service Division We currently take care of service and maintenance contracts for various Gas Analysers and Instruments from companies like ABB-Nasik & Baroda, S & S Power Switchgear Ltd.- Baroda and Crompton Greaves-Nasik. 2 pg

Sales and Support Network To cater specific needs of our customers who are scattered in all parts of India, CSL has developed an efficient well connected marketing team consisting of Dealers operating in all four corners of India. Though most of the marketing takes place through direct personal customer contact, CSL also participates and advertise regularly in various Fairs and Exhibitions, Journals related to Analytical Instruments. CSL CUSTOMERS Our customers belong to the following categories: Petrochemical Refineries, Steel, Fertilizer, Cement, Power, Oil & Gas, Instrumentation & Research Institutes. CSL products are used in the above industries mainly in quality control and instrumentation departments for calibration of various instruments like process analysers, gas chromatograph, toxic gas monitors & flammable gas analysers. We are supplying our products to various ISO-9000 Companies, Government and Semi Government Organizations like Enron Oil & Gas India Ltd., Reliance Petroleum Ltd., Hyundai and Indian Petrochemicals Corp. Ltd., Oil & Natural Gas Corp. Ltd., Rashtriya Chemicals & Fertilizers Ltd., Department of Atomic Energy, ACC and Bureau of Indian Standards. CSL TEAM Consisting of well trained qualified chemists with education qualification of B.Sc., M.Sc. and have more than 9-10 years experienced engineers and senior quality control inspectors. Apart from that we also have assistance from various consultants. The Managing Director of the company Dr. O.P. Srivastava has been awarded PhD. Degree from University of Wales-U.K. in the field of Gas Chromatography, has been associated for more than 30 years in developing G.C. s, Process Control Instruments, etc. As a retired BARC scientist, his expertise and experience value added to all our activities. Advantages TECHNICAL Complete in-depth technical knowledge of working & manufacturing GC s, Gas Analysers in terms of Electronics and Analytical capability. Trained Chemists, in house availability of Std. Gas Mixtures and well-equipped Analytical Lab. enables to fulfill all calibration standardization needs of the instruments. Qualified Engineers already experienced in installation, repair and maintenance of Instruments. COMMERCIAL Well established contacts in industry in the field of instrumentation over the past eight years. Good infrastructure with latest communication facilities. Registered with various consultants, projects and system houses, in most of the government /non government institutions in all over India.

Chemtron Science Laboratories Pvt. Ltd. GAS CHROMATOGRAPH GC WITH COLUMNS IN OVEN SYRINGES SAMPLING CONTROL VALVE FOR GC SAMPLE COLLECTORS

SPECIFICATIONS OF CSL GC Technical Specifications Outline: The Gas Chromatograph is 24 Bit microcontroller based instrument with 40x4 alphanumeric LCD display with back light for Injector, Column Oven, Detector and all heated zones temperature indications. It has a built in 24 bit high resolution data integrator A/D board with sampling frequency up to 20 Hz. It is having injection system suitable for analysis of Gas sample and liquid samples on packed/capillary columns using Thermal Conductivity and Flame Ionization Detectors. The data system has complete control of instrument conditions. Complete runtime display of chromatograms, quantification of analysis. It has advance options of storage and processing analytical data. What makes it affordable! Chemtron has been designing low cost gas chromatographs for over a decade. Chemtron has team of highly skilled and experience R&D department which consists of chemists and engineer's who have been developing these instruments specially for small scale industries, collage s and educational institutional which could not afford these analytical instruments. The complete system is made in house which includes The complete instrument consisting of Detectors, Columns, Pneumatics, Chassis, Electronics and also the Data integration software and its 24 Bit A/D board. CSL-MODEL No.-1045 CSL-MODEL No. 2045 Description (With Single Detector - PIP. FPD. ECD. HID. TCP or FID) Gas Chromatograph will have the facility of Pressure Regulator Valve / Pneumatics Mass flow controller integrators, Manual cooling oven. Operating sensitivity mode (Low / Medium / High). The data system will have facility of control of instrument conditions, display of Chromatograms, quantification of analysis and storage of analytical data. CSL-1045 Gas Chromatograph also having optional facility of Methanizer. manual sampling valve, split/split less injection port for FID for dedicated analysis. University /College/Educational, Etc. (With Dual Detector-Upgradable up to 3 Detector) Gas Chromatograph will have the facility of TCD protection circuit, oven heat protection, in built integrators for data acquisition system. CSL-2045 Gas Chromatograph also having optional facility of M.F.C. (Digital), Methanizer, manual gas sampling valve for ppm level analysis of CO & CO2, data system with PC Storage of Chromatogram. Up to 3 detectors with TCD in series with FID can be configured for natural Gas analysis, Dissolved gas Analysis (TOGA). DGA Analysis/Solvent Gas Analysis/Permanent Gas Analysis. Detectors Single Dual up to 3

Chemtron Science Laboratories Pvt. Ltd. Injection System (Controlled from PC with Software common for all models) Single port (Dual Optional) Single/Dual with two packed columns and one 1 PTV with split/split less spot Operating Temp. Range Ambient 350^C Ambient 350^C Pressure Control System Pressure regulator for carrier as well as air and H2 for FID. Mass flow controller for carrier gas. Optional TCD Different Pressure regulators for the air and H2 for FID. Mass flow controller for carrier gas. Column Oven Temp (Controlled from PC with Software) common for all models Ambient 350^C react rate of 6 minutes at 1C/min to 30C / min with 7 ramps Ambient 350^C with react rate of 4 minutes at 1oC/min to 30C /min with 7 ramps Cooling Speed 350C to 30C in 10 mins. with manual control. 350C to 30C in 4 min with auto control. Over Heat Protection Available Hardware / Software Available Hardware / Software Temp. Programming Ambient to 350C with 1C/min to 30C/min with 7 ramps Ambient to 350C with 1C/min to 30C/min with 7 ramps Optional Facility Methanizer for detection of CO at ppm level. 24 bit software with pc control with instrument conditions, display of chromatographs, quantification and analytical data. Methanizer for detection of CO at ppm level. 24 bit software with pc control with instrument conditions, display of chromatographs, quantification and analytical data. Accessories Packed column silica gel / molecular sieve 13 x gas tight syringe, septa, carrier gas cylinders, 24 bit data integrator with PC and printer Packed column silica gel / molecular sieve 13 x gas tight syringe, septa, carrier gas cylinders, 24 bit data integrator with PC and printer Weight 8KG 18KG

http://wstemp.imart.intermesh.net/chemtron/electronics.html#gas-chromatograph