GAS CHROMATOGRAPHY PURDUE UNIVERSITY INSTRUMENT VAN PROJECT. DEMYSTIFICATION ACTIVITY FOR THE GAS CHROMATOGRAPH (Revised: ) INTRODUCTION

Similar documents
Chemistry Materials Separation Processes

Laboratory Techniques

Laboratory Techniques

Safety Lab Goggles are required! Apron is optional!

Laboratory Techniques

Vernier Mini GC Plus Gas Chromatograph (Order Code: GC2-MINI)

Test Tube Rack. Test Tube

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

PROTOCOL FOR FREE LIPID SOP

Standard Operating Procedure for Oil & Grease Method EPA1664A

Aquamax KF Oil Evaporator. User Manual

4.3 Higher Elementary Exercises

STUDENT SAFETY RULES

Operating Instructions

1. Conduct yourself in a responsible manner at all times in the laboratory.

HISTORY OF VARIAN CAPILLARY INJECTORS

Laboratory SAFETY RULES

22 The Flame Ionization Detector

HydroFlux Welder Torch System T0-102 / T0-103

Vernier Gas Chromatograph Mini GC (Order Code: GC-MINI)

Vernier Gas Chromatograph Mini GC

Chapter 10: Laboratory Equipment

Laboratory Equipment. Section 1L. Chemistry I & II

Science Lab Equipment

BAXTER: FACTOR VII 600 IU (Plasma Derived)

Parents and Educators: use #CuriousCrew #CuriosityGuide to share what your Curious Crew learned!

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

Safety In Chemistry. Identified Risks and Hazards

Laboratory Equipment. Use of equipment

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

APPENDIX A: MICROSCALE APPARATUS AND TECHNIQUES A.1 CRAIG TUBES: RECRYSTALLIZATION

FPD - Flame Photometric Detector

Centrifuge STANDARD OPERATING PROCEDURE

CHM 130LL: Lab Safety Name: Answer Key _ Section:

DEPARTMENTAL SAFETY ISSUES - SAFETY TECHNOLOGIST / INFECTION CONTROL PRACTITIONER

Familiarize yourself with the following:

Chiltern Model Steam Engines

Safety Scenarios. You enter the lab and discover that you will be boiling water in a beaker and pouring the hot water into a separate container.

Aromatics and Oxygenates in Gasoline June2018

Lab Safety. Section 2L. Chemistry I & II

PASTEURIZED MILK CONTAINERS, CLOSURES AND PACKAGING IMS #22 (PMC) [Unless otherwise stated all tolerances are ±5%] 1. Laboratory Requirements

GAS COOKTOP INSTALLATION INSTRUCTIONS

Multi-Mode Electrode pro

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

Unit 21 Charles's Law. Procedure

Monitoring Flammable Vapors and Gases in Industrial Processes

Agilent Vac Elut SPS 24 Manifold User Guide

Exploded View - Model J-7020M/J-7040M Miter Cut-off Saw Base

Assembly and Running Instruction for Steam engine

Chemtron Science Laboratories Pvt. Ltd.

OIL MIGRATION IN R-12 & R-22 SYSTEMS By: Norman Sharpe Professor, Air Conditioning & Refrigeration Dept., California State Polytechni College

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

Thermal Stability Systems

Installation Instructions

The Heidelberg Integrated 14 CO 2 Sampler Institute of Environmental Physics, ICOS CRL

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /

04.SOIL MOISTURE MEASUREMENT

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Student and Demonstration Experiments TESS. beginner. Heat

H-10PM. Refrigerant Leak Detector

Buehler Cast N Vac 1000 Embedding System

Indirect Cryogenic Cold Trap System Instructions

Ion OneTouch Template Kit Publication Part Number Revision E Date 31 October 2011

WARNING! For your safety

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

PDMS Casting Station Supplies

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

1 L Rotary Vacuum Evaporator Instruction Manual

ChBE Safety Training. July Emily Edwards Lab Coordinator Chemical & Biological Engineering Tufts University 4 Colby St., Room

Assembly of a Microbial Fuel Cell

Name Science Period 1

IMPORTANT INSTRUCTIONS OPERATING MANUAL

Mildew & Rot Proof Standards

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

In Chapter 3 you learnt that woollen

BASIC SYSTEM LOCATION INDEX

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

Steam Blaster Model EP95B

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

UNITY 2 TM. Air Server Series 2 Installation Manual. Version September 2012

SUS-12 Steam Cleaner User Manual

Avila Contemporary Indoor Outdoor Ethanol Fireplace. User s Manual. Model: GF201500

Experiment 4: Purification of Liquids by Distillation

Installation Instructions Preference Wall Mount Range Hood

Activity Sheet Chapter 1, Lesson 1 Molecules Matter

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Information Job Sheet 4. Closed-Loop Drainback Systems. Drainback tanks

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

OWNER S MANUAL. Smoky Hill 5pc Gas Firepit Chat Set. Product Code: D71 M25973 UPC Code: Date of Purchase: / /

Introduction. Sharps. Working Safely with Sharps at UAB (OHS_HS255) Objectives. Defined

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

MODEL: CGG-306 Chef s Style Portable Tabletop Grill ASSEMBLY AND OPERATING INSTRUCTIONS

Effects of Wind on Plant Size

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Users Manual. Automatic Vaccinator for Poultry (Dual Syringe) Changzhou ZA Medical Devices

Transcription:

INTRODUCTION DEMYSTIFICATION ACTIVITY FOR THE GAS CHROMATOGRAPH (Revised: 1-24-93) Gas chromatography (GC) is a very powerful tool for separating components of a mixture. The GC utilizes the physical and chemical properties of the components to achieve the separation. A mixture of compounds, the sample, is injected and vaporizes in a stream of carrier gas. The carrier gas is used to force the sample through the system, much as water forces a boat down a river. The vaporized sample and the carrier gas make up the mobile phase of the GC. All of the components of the mobile phase move through the system at the same rate until they reach the stationary phase. The stationary phase is designed to resist the flow of the mobile phase. Each component of the mobile phase is slowed a different amount as it passes through the stationary phase. Therefore, each component of the mobile phase leaves the system at a different time and produces a separation. A detector is placed at the end of the system to record when each of the components exits the system. Below is a schematic of a typical GC. SAFETY CONSIDERATIONS 1)The carrier gas for this activity is methane. Do not leave the gas jet on without lighting the flame. 2)The burner tip of the GC will remain hot for a long time after the flame is extinguished. 3)Take care when bending glass in a burner flame. It will cool slowly. 4)Halogenated hydrocarbons tend to be flammable and somewhat toxic. This activity should be carried out in a well ventilated room. Keep the samples away from open flames. 5)The samples should be kept in sealed containers to prevent them from evaporating. These compounds are hazardous to the ozone layer and should be contained as much as possible. Preparation of the GC

MATERIALS 1 x 20 cm glass tubing 1 x 60 cm rubber/ tygon tubing 2 x 2 cm rubber/ tygon tubing 1 x 4 cm rubber/ tygon tubing 1 glass Pasteur pipet 1 cotton ball 1 x 30 cm fine copper wire 1 box of matches 2 clothes pins (utility clamps) l small cup of activated TIDE (dried in an oven overnight) 1 glass/ plastic T 1 pinch clamp 1 plastic syringe without the needle PROCEDURE PART A - PREPARATION OF THE GC COLUMN 1.Put a small cotton plug into one end of the glass tube. 2.Attach a funnel to the open end of the tube with a small piece of rubber tubing. 3.Fill the glass tube with activated Tide by pouring it through the funnel. 4.Tap the funnel or tube to break up any clogs. DO NOT stick anything into the funnel or tube to break up blockages. This will only make matters worse. 5.After filling the tube, tap it gently on a rubber stopper to settle the Tide in the column. If necessary add more Tide to fill the tube to within 0.5 cm of the top. 6.Place a cotton plug into the open end of the tube. PART B - PREPARATION OF THE BURNER ASSEMBLY 2

1.If your teacher has prepared your burner assembly for you, go on to the next section. 2.Obtain a glass Pasteur pipet. Place the tapered part of the pipet into a burner flame. Rotate the pipet until it starts to bend. Stop rotating the pipet and allow it to bend to a right angle. 3.Remove the pipet from the flame and allow it to cool. Caution the glass will remain hot for several minutes! PART C - PREPARATION OF THE DETECT0R 1.Wind the piece of copper wire around the large end of the pipet as shown below. As you wind the coils, keep your thumb on the end of the wire to prove tension. 2.Make 10 wraps around the pipet and leave a 3 cm tail of wire. Cut the remaining wire. The wire must be wrapped tightly together. 3.Slip the wire off of the pipet. 4.Bend one of the tails so that it runs down the center of the coil perpendicular to the coils. 3

5.Place the bent tail into the SMALL opening in the burner assembly. 6.Tuck the other tail into the coil. PART D - ASSEMBLY OF YOUR GC 1.Push one end of the long piece of rubber tubing onto the gas jet at your lab station 2.Attach the other end of the tubing to the glass/ plastic T. 3.Attach a 4 cm piece of tubing to the T at a right angle to the first. 4.Attach a 2 cm piece of tubing to the third opening of the T. 5.Attach the Tide column to the other end of the 2 cm piece of tubing. 6.Attach the other 2 cm piece of tubing to the other end of the Tide column. 7.Connect the burner assembly to the 2 cm piece of tubing. 8.Adjust the burner assembly so that the detector is in a vertical position. 9.Secure the GC with the clamps provided. 4

Lab Activities For Your GC PART A - AGING YOUR BEILSTEIN DETECTOR The detector for your GC is based upon the Beilstein test for Halogenated hydrocarbons. This test identifies compounds that contain halogens by burning them in a flame with copper metal. A blue-green flame indicates the presence of a halogen. Our GC, therefore, can only be used to separate compounds that contain a halogen. For the detector to work properly it must first be "aged." That is, it must be burned in a flame until the copper metal turns black. 1.Assemble the GC as directed above. 2.Turn on the gas jet. CAUTION: Do not leave the gas jet on without lighting the flame. An explosion could result due to the build up of methane gas in the room. 3.Light the flame with a match. 4.Allow the flame to burn for several minutes before you move to the next activity. CAUTION: You may leave the flame burning throughout the period as long as you do not leave it unattended. PART B - MEASURING THE RETENTION TIME OF THE GC COLUMN The retention time is the time that it takes for a substance to pass through the GC. Different substances will move through a GC at different rates depending upon their properties. 1.First we will measure the retention time for air. 2.Turn the gas on all the way and light the flame. 3.Inject 0.5 ml of air into the injection port of your GC. 4.Carefully measure the SHORT amount of time that it takes for the air to pass through the GC. The flame will dip, become smaller, when the air gets to the flame of the detector. This is caused by a change in the fuel air mixture. 5

Now your are ready to run samples of known compounds through your GC to measure their retention times. 5.Draw up a syringe full of VAPOR, not liquid, out of one of the sample bottles. 6.Hold the tip of the syringe near the flame of the detector and slowly inject the sample into the burner flame. Notice the color change in the flame. This is the indicator to look for when injecting samples through the GC. 7.Fill the syringe with vapor from the same sample as before. Inject the sample into the injection port of the GC and determine the retention time for the sample. Record in the DATA TABLE the amount of time that it takes for the first color change in the flame. Also record in the DATA TABLE the amount of time it takes for the flame to return to its original color. 8.Repeat the process for the other samples that are provided. Record your data and observations. 9.If time permits, try injecting a mixture of two of the samples into the GC. 6

NAME CLASS PERIOD DATA TABLE Sample Amount of Time For First Color Change In The Flame (sec) Amount of Time For Flame to Return to its Original Color (sec) LAB WRITTEN BY: RICHARD HEASTON 7