PRODUCT CATALOGUE

Similar documents
4FLOOR-STANDING GAS CONDENSING BOILERS

8FUEL OIL CONDENSING BOILERS

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

FLOOR STANDING GAS CONDENSING BOILERS HOMOLOGATION C 630- ECO: B 23 - B 23P - C 33 - C 53 - C 63 - C 83 - C 93

GTU C 220 FUEL OIL CONDENSING BOILERS

FLOOR-STANDING GAS CONDENSING BOILERS FROM 3.4 TO 35.9KW. by 160 litre enamelled calorifier with coil placed CONDITIONS OF USE HOMOLOGATION

C ECO FLOOR STANDING GAS CONDENSING BOILER CONDITIONS OF USE HOMOLOGATION GAS CATEGORY

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

PMC-M WALL-HUNG GAS CONDENSING BOILERS

FLOOR STANDING GAS CONDENSING BOILERS CONDITION OF USE CLASSIFICATION

Innovens Pro. Wall-hung gas condensing boilers MCA Installation and Service Manual A

NANEO EMC-M EASYLIFE WALL-HUNG GAS CONDENSING BOILERS

>> >> >> High technology with oil. High performance modulating burner Compact boiler design. Compatible with renewable energies. Sustainable Comfort

GT 120 >> >> >> << >> Sustainable Comfort. Longlasting comfort

ADVANCE EASYLIFE PROJECT

GT 220 CAST IRON FLOOR-STANDING FUEL OIL- / GAS-FIRED BOILERS

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

GT 220 PROJECT CAST IRON FLOOR-STANDING FUEL OIL-/GAS-FIRED BOILERS

<< >> Condensing technology at the service of oil. Controlling energy to save money

HPI REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER

Modulens G >> >> >> Condensing in excellence mode

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

MPX 24/28 MI Compact MPX 28/33 MI Compact CONDITIONS OF USE HOMOLOGATION. B 23 - C 13x - C 33x - C 53x - C 93x - C 83x* B 23p - B 33 - C 43x

C 330 ECO - C 630 ECO

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

DIEMATIC VM isystem WALL-MOUNTED CONTROL SYSTEM. DIMENSIONS Length: 320 mm Height: 260 mm Depth: 130 mm. POWER SUPPLY 230 V, 50 Hz, 6 A

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

EMC-M 24 EMC-M 24/28 MI EMC-M 30/35 MI EMC-M 34/39 MI

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

C Tahiti. condensing

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

After Sales Service Guide

Sirius WH. Working towards a cleaner future

Exclusive Green E Condensing Wall-Hung Boilers

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Condensing, pre-mixed, wall-hung gas boilers with water tank

MCR 24 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MI

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX

1 VICTRIX ZEUS Superior kw I features

WHE 2.24 / WHE 2.24 FF

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

ENERGY TOP. Condensing boiler solutions

HeatMaster. Assembling and installation instructions. 201 Booster. HeatMaster. HeatMaster. 200N (Gas) Booster ENGLISH FRANCAIS NEDERLANDS ESPAÑOL

white blue cobalt bordeaux light oak (rovere)

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

PCH/new Series. High performance, total flexibility

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Stokvis R40 Boiler Gas-Fired Wall Hung Condensing

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

WOLF GAS CONDENSING BOILERS COMFORTLINE

ECONOFLAME R6000 LMS GAS FIRED CONDENSING BOILERS

VIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw

Sirius FS. Working towards a cleaner future

Power X High Power Condensing Wall-Hung Boilers

Vivadens. Wall-hung gas condensing boilers MCR 24/28 BIC. User Guide B

Planner Documentation THISION L

Light commercial products. High output boilers Cascade systems

PrestigeMK2. Installation, Operating and Servicing Instructions. Prestige Solo Prestige AquaSpeed Prestige Excellence ENGLISH

Rapid. Suspended Warm Air Heater. Caring for the environment!

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

MINORCA KC - KR - KRB 24

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Power X High Power Condensing Wall-Hung Boilers

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

FORMENTERA KC - KRB - KR

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

COND SYSTEM Condensation boiler outdoor / indoor combined with indoor heaters

R40 (Evolution Range) Gas-Fired, Wall Hung Condensing Boiler Boiler Options & Systems Planner Manual

Gas-fired unit heaters for indoor installation

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 310/610 ECO PRO RANGE FEATURES AND BENEFITS

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

ALEZIO REVERSIBLE AIR/WATER HEAT PUMPS SPLIT INVERTER CONDITIONS OF USE

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

GB Condensing Gas Boiler

Transcription:

PRODUCT CATALOGUE 010- PROJECT INNOVENS PRO CA 5-115 from 8.9 to 11 (7.6-98.0 cal/h) Wall-hung gas condensing boilers P. PROJECT INNOVENS PRO CA 5-115 CASCADE SYSTES from 80 to 8 (68.8-368 cal/h) Complete cascade systems for to CA 5, 65, 90 or 115 boilers P. 6 Provide a solution to every customer SOLAR SOLID FUEL HEAT PUPS CONDENSING BOILERS Sustainable Comfort

from 7.6 to 98.0 cal/h from 8.9 to 11 for chimney connection or forced flue Wall-hung gas condensing boiler for heating CA_Q0018 n CE 0063CL3333 AIN DIENSIONS (mm and inches) ➁ Heating flow R1 1/ ➃ Gas inlet R 3/ ➅ Heating return R 1 1/ ➇ Condensates drain (siphon and flexible drain Ø 5 mm ext provided) ➈ Air/flue gas connection Ø 80/15 mm for CA 5 Ø 100/150 mm for CA 65, CA 90 and CA 115 PROJECT INNOVENS PRO CA 5, CA 65, CA 90, CA 115 - Wall-hung gas condensing boiler - Equipped to operate on natural gases and can be converted to propane - Gas supply pressure: 0 mbar - Forced flue or chimney connection - Annual operating efficiency up to 110% - Low pollutant emissions: NOx < 37 mg/h for CA 5, 3 mg/h for CA 65, 5 mg/h for CA 90 and 6 mg/h for CA 115 - onoblock heating body in aluminium/silicium - Gas premix burner in stainless steel with a surface in woven metallic fibres, modulating from 18 to 100% of output - Fan with air intake silencer - Delivered with integrated automatic air vent, run-off siphon 80 500 191 30 80 100 - Choice of one of the following two control panels: DIEATIC isystem : control panel to control and regulate up to 3 heating circuits + 1 DHW circuit, depending on optional equipment connected, according to the outside temperature. It can also be used to optimise management of combined control system associated with boilers with IniControl (even DIEATIC isystem) and control cascades of to 10 boilers. inicontrol : for operation either according to outside temperature (sensor optional), or through the 0-10 V contact fitted to this panel as standard. It can also be used as a secondary boiler as part of a cascade installation controlled by a boiler with the DIEATIC isystem control panel or in a cascade system in which each boiler is controlled in 0-10 V. (see page ). Packaging: packages 500 9 100 INNOVENS RESIDENTIAL OUTPUTS see page 7 of the product catalogue 010 Wall-hung condensing gas solution, high performance for small collective and tertiary application 95 750 6 8 191 365 50 13 8 6 50 75 CA_F008 TECHNICAL SPECIFICATIONS Condensing in. outlet temperature: 0 C in. return temperature: 0 C - ax. operating temperature: 90 C - ax. operating pressure: bar Protection index: IPXDD Power supply: 30 V/50 Hz Classification: B 3P, C 13x, C 33x, C 93x, C 53 CA 5 65 90 115 Nominal output at Pn (50/30 C) 3 65 89.5 11 Effi ciency at % - 100% average temp. 70 C % 97. 98.3 97.9 96.6 output and C { 100% return temp. 30 C % 10.9 10.6 10.1 10.5 water temp. 30% return temp. 30 C % 107.7 108.9 108.1 107.1 Water fl ow at Δt = 0 K 1.7.6 3.6.60 Auxiliary electrical power at Pn/Pmin (without circul. pump) W 68/18 88/3 15/0 199/5 in./max. useful output at 50/30 C 8.9-3 13.3-65.0 15.8-89.5 18.-11 in./max. useful output at 80/60 C 8-0 1-61 1.1-8. 16.6-107 in./max. fl ue gas mass fl ow rate kg/h 1/69 1/10 8/138 36/178 Flue gas pressure available Pa 150 100 160 0 Water content l 5.5 6.5 7.5 7.5 inimum water fl ow 0. 0. 0. 0. Water resistance at Δt = 0 K mbar 90 130 10 50 Gas fl ow - natural gas H. 6.6 9.1 11.7 (15 C-1013 mbar) { - propane 1.7.5 3.5.7 Net weight kg 53 60 68 69 odel CA 5 65 90 115 CA isystem Ref. 100016199 10001600 10001601 1000160 CA inicontrol Ref. 100016195 100016196 100016197 100016198 NB: These boilers have been designed, tested and certifi ed with the fl ue systems offered in our catalogue, pursuant to the requirements of standard EN 83 covering central heating boilers using gaseous fuels. We guarante the safety and correct operation of our boilers as long as they are installed with the certifi ed fl ue systems under the conditions recommented in our technical documentation. OPTIONS: see page 3, SYSTES CASCADES: see pages 6-7, FLUE SYSTES: see page 8 and chapter 17 of the product catalogue 010 www.dedietrich-heating.com

OPTIONS FOR INNOVENS PRO CA 5 TO 115 ALL OPTIONS EXCEPT CONTROL UNITS OPTIONS Hydraulic connection kit HC 139 10000310 Pipe cover HC S101539 Insulation for hydraulic boiler connection kit HC 5 11 Rear insulation for hydraulic boiler connection kit HC 3 1318 Flue gas thermostat HR 3 S100310 3-stage heating pump for - CA 5 HC 11 1000031 - CA 65 HC 13 1000031 - CA 90/CA 115 HC 15 10000316 Electronic heating pump of class A for CA 5 HC 1 10000313 Primary pump for CA 5-65, 90-115 HC 17 1000033 otorized 3 way valve HC 15 85317005 Right gas tap 3/ CA 5 to 115 HC 158 1000061 HW PLUS 70 decoupling cylinder HC 8 85317018 HW 00 decoupling cylinder HC 9 85317019 Neutralisation station (without pump) HC 33 8531703 Wall bracket for neutralisation station HC 3 853170 Neutralisation granules kg HC 35 8531705 Condensates neutralisation system with lift pump - boiler up to 10 DU 13 83877009 - from 10 to 350 DU 1 83877010 - from 350 to 1300 DU 15 83877011 Neutralisation granules 10 kg for DU 13, 1 and 15* - 95601 Cleaning tool boiler body CA 5/65 HC 6 S58 Cleaning tool boiler body CA 90/115 HC 7 S5886 Adapter bi-fl ow x Ø 80 mm DY 906 S10076 Adapter bi-fl ow x Ø 100 mm DY 907 S10166 * To order at the spare parts department DESCRIPTION (cascade installations) PACKAGE REF. CA mounting rail on an existing C cascade system ("LV" and "RG" alignment only) HC 5 S10163 Gas fi lter Ø 50 mm HC 07 111779 Set of elbows Ø 65 mm HC 09 111788 Extension pipe for gas fi lter Ø 50 mm HC 11 111805 Collector insulation HC 13 111069 Insulation for hydraulic boiler connection kit HC 5 11 Rear insulation for hydraulic boiler connection kit HC 3 1318 Decoupling cylinder insulation < 350 HC 11569 Decoupling cylinder insulation > 350 HC 15 111067 Insulation 90 elbow HC 16 111167 Set of counter fl anges to be welded Ø 65 mm HC 17 1163 Adjustable foot HC 19 111807 For cascade of 8 to 1070 : Gas fi lter Ø 65 mm HC 08 111780 Set of elbows Ø 100 mm HC 10 111790 Extension pipe for gas fi lter Ø 65 mm HC 1 111806 Set of counter fl anges to be welded Ø 100 mm HC 18 11633 DHW PRODUCTION PACKAGE REF. With solar calorifi er see chapter 1 and 10 of the product catalogue 010 With independent water calorifi er see chapter 19 of the product catalogue 010 CA 5 to 115/BL, BP, BSC and DT connecting kit EA 11 10000787 HC 15 HC 139 HC 33 HC 8 HC 9 HC 1 CA_F0065 8531Q00 HC 11 (HC 13) (HC 15) (HC 1) (HC 17) HC 3 HC C10_Q0016 CA_F0015 C35E_Q001 HC 6 HC 7 HC 158 HR 3 HC 16 HC 19 CA_F0065 CA_F0015 CA_F0015 C35E_Q001 C35E_Q001 HC 3 HC 5 8531Q07 8531Q08A CA_F0065 HC 07 HC 08 CA_F0065 HC 11 HC 1 CA_F0065 8531Q06 DU 13 8531Q017 C10_Q001 HC 17 HC 18 CA_F0065 HC HC 5 HC 13 CA_F0065 CA_F0065 www.dedietrich-heating.com 3

OPTIONS FOR INNOVENS PRO CA 5 TO 115 CONTROL UNITS OPTIONS CHOICE OF OPTIONS ACCORDING TO THE CONTROL PANEL TYPE AND THE CONNECTED CIRCUITS Circuit Boiler self-standing or boiler 1 of a cascade Boiler to 10 of a cascade type for additional boiler () INNOVENS PRO CA 5 to 115 DHW direct valve direct + x valve direct with control panel: 1 valve + x with valve valve x with valve inicontrol + 1 x AD 1 as standard (1) no no no no no no DIEATIC isystem (3) + 1 x AD 1 as standard 1 x AD 199 1 x AD 199 With inicontrol 1 x AD 199 1 x AD 199 control panel + 1 x AD 9 + 1 x AD 9 no no With DIEATIC isystem control panel () 1 x AD 199 1 x AD 199 + 1 x AD 9 for DIEATIC isystem control panel: CDI D. isystem remote control AD 5 100013309 Radio remote control CDR D. isystem module (without radio transmitter/receiver) AD 53 100013308 Room temperature sensor AD 100010 Radio outside temperature sensor AD 51 100013306 Boiler radio module (transmitter/receiver) AD 5 100013307 Simplified remote control + room sensor F 5 8575777 PCB + sensor for mixing valve AD 9 10001330 Simplified remote control + room sensor F 5 8575777 Sensor for mixing valve AD 199 88017017 DIEATIC BUS connection cable (1 m) AD 13 88017851 DHW sensor AD 1 100000030 Sensor for storage tank AD 50 100013305 for inicontrol control panel Outside temperature sensor F 6 8575771 (1) + Package F 6 (outside temperature sensor) to control an installation of a single boiler according to the outside temperature. Without outside temperature sensor, the CA inicontrol boilers used as single boiler or as part of a cascade installation, will be connected through the 0-10 V contact. () According to the number of heating circuits to be connected, it will be necessary to insert 1 or more CA isystem slave boilers in the cascade, the other boilers of the cascade being fitted with the inicontrol control panel. (3) Each of the circuits "heating" can be completed in choice by a remote control AD 5, AD 5/53, F 5 or room sensor AD. www.dedietrich-heating.com

TS AUXN L L AUX L L TS N 13: 13: 13: 13: 13: EXAPLES OF INSTALLATIONS FOR INNOVENS PRO CA 5 TO 115 INNOVENS PRO CA isystem - circuits with mixing valve - 1 DHW calorifier CA 5 isystem AD5 AD5 1x AD199 + 1x AD9 30V GAS HC 139 HC 17 AD 1 8 CA_F007A Boiler CA 5 isystem - 100016199 1 x Sensor for mixing valve AD 199 88017017 1 x PCB + sensor for mixing valve AD 9 10001330 DHW calorifier BP 00 EC 03 10000673 Options Hydraulic connection kit CA 5 HC 139 10000310 Primary pump HC 17 1000033 x CDI D. isystem remote control x AD 5 x 100013309 INNOVENS PRO CA inicontrol - 1 direct circuit - 1 DHW calorifier F 6 CA 5 inicontrol 30V 30V Boiler CA 5 inicontrol - 100016195 DHW calorifier BL 00 EC 10001306 CA /BP, BL connecting kit EA 11 10000787 Outside temperature sensor F 6 8575771 Options Hydraulic connection kit CA 5 HC 139 10000310 Electronic heating pump for CA 5 HC 1 10000313 EA 11 GAS HC 139 HC 1 EA 11 AD 1 (b) CA_F0071B 1 x INNOVENS PRO CA isystem x INNOVENS PRO CA inicontrol - 1 direct circuit - circuits with mixing valve - 1 DHW calorifier 1x AD199 CA... isystem 30 V CA... inicontrol CA... inicontrol 30 V 30 V 30V (b) AD5 AD5 AD5 + AD1 1x AD9 BUS BUS B 1000 GAS Cascade system CA_F0073 1 x boiler CA 5 isystem - 100016199 x boiler CA 5 inicontrol - x 100016195 1 x Sensor for mixing valve AD 199 88017017 1 x PCB + sensor for mixing valve AD 9 10001330 Cascade system for 3 boilers CA 5 wall-hung alignment - LW.010.3000 DHW calorifier B 1000-8975981 Options 3 xcdi D. isystem 3 x AD 5 3 x 100013309 www.dedietrich-heating.com 5

from 68.8 to 368 cal/h from 80 to 8 INNOVENS PRO CA 5, 65, 90 OR 115 CASCADE SYSTES DIEA T O O L S Complete cascade systems for to CA 5, 65, 90 or 115 boilers CA_F007 : n. CE 0063BL353 PROJECT CA 5 to 115 cascade systems are available in 3 versions: - LW: for wall-hung alignment of the boilers - LV: for floor-standing alignment of the boilers - RG: for back to back assembly of the boilers These systems include: - the decoupling cylinder - the boiler connection collector including the heating flow and return connection pipes Ø 65 mm, the gas connection pipes Ø 50 mm and the flanges - the primary injection pumps - the boiler connection kits including the outlet valve, the multi-function return valve (with filling and draining valve, gate valve, non-return valve, safety valve and connection for the expansion vessel), and the gas valve - the wall assembly rail for LW versions or, for LV and RG versions, the corner support structures with the boiler assembly frame - the outlet sensor + sensor tube and the inter-boiler BUS connection cable Nota: the boilers should be ordered separately Options: - insulating shells - connecting flanges (see page 3) The modularity in answer to high output CASCADE COBINATIONS DEPENDING ON THE TOTAL REQUIRED OUTPUT () - Wall-hung alignment: LW boilers 1337 080 0 0 0 3.3 LW.0080.000 1 0 0 0 5.3 LW.01.000 168 0 0 0 7.0 LW.0168.000 1 0 0 0 9.17 LW.01.000 05 3 boilers 1867 10 3 0 0 0 5.1 LW.010.3000 183 0 3 0 0 7.8 LW.0183.0300 5 0 0 3 0 10.80 LW.05.0030 31 0 0 0 3 13.76 LW.031.0003 05 boilers 50 (1) 05 397 739 (1) CA_F0060 160 0 0 0 6.86 LW.0160.000 0 0 0 10.6 LW.0.000 336 0 0 0 1.0 LW.0336.000 8 (1) 0 0 0 18.3 LW.08.000 (*) except insulating shells (1) with decoupling cylinder > 350 Caption: Designation LW 0080000 Type Total Composition: boilers CA 5 of alignment output 0 boilers CA 65 (LW, LV or RG) (at 80/60 C) 0 boilers CA 90 0 boilers CA 115 6 www.dedietrich-heating.com

CASCADE COBINATIONS DEPENDING ON THE TOTAL REQUIRED OUTPUT () - Floor-standing alignment: LV boilers 136 80 0 0 0 3.3 LV.0080.000 1 0 0 0 5.3 LV.01.000 168 0 0 0 7.0 LV.0168.000 1 0 0 0 9.17 LV.01.000 60 3 boilers 189 10 3 0 0 0 5.1 LV.010.3000 183 0 3 0 0 7.8 LV.0183.0300 5 0 0 3 0 10.80 LV.05.0030 31 0 0 0 3 13.76 LV.031.0003 60 boilers 160 0 0 0 6.86 LV.0160.000 0 0 0 10.6 LV.0.000 336 0 0 0 1.0 LV.0336.000 8 (1) 0 0 0 18.3 LV.08.000 (1) 500 60 739 (1) - back to back alignment: RG 3 boilers CA_F0061A 10 3 0 0 0 5.1 RG.010.3000 183 0 3 0 0 7.8 RG.0183.0300 5 0 0 3 0 10.80 RG.050030 31 0 0 0 3 13.76 RG.031.0003 136 91 boilers 1008 91 (1) 160 0 0 0 6.86 RG.0160.000 0 0 0 10.6 RG.0.000 336 0 0 0 1.0 RG.0336.000 8 (1) 0 0 0 18.3 RG.08.000 (*) except insulating shells (1) with decoupling cylinder > 350 () Important: boiler cascade of up to 1070 : consult us 136 1679 (1) CA_F0063A OPTIONS: see page 3 www.dedietrich-heating.com 7

FLUE SYSTES FOR INNOVENS PRO CLASSIFICATION = L1+L L1 L C 13x 1 L1 = L1+L C 53 5 L C 33x 1m max B 3P 6 7 C 33x 1m max C 93x 3 1m max C 93x C 33x CR_F0011C Classification C 13x : Air/flue gas connection through concentric pipes to a horizontal air/flue gas vent (so-called forced flue) Classification C 33x : Air/flue gas connection through concentric pipes to a vertical air/flue gas vent (roof outlet) Classification C 33x (newly C 93x ) : Air/flue gas connection using concentric pipes in the boiler room and single pipes in the chimney (combustive air in counter current in the chimney) or Air/flue gas connection using concentric pipes in the boiler room and single "flex" pipes in the chimney (combustive air in counter current in the chimney) Classification C 53 : Separate air and flue gas connection using a bi-flow adapter and single pipes (combustive air taken from outside) Classification B 3P : Connection to a chimney (combustive air taken from the boiler room). Classification B 3P : for cascade installations TABLE OF AXIU AIR/FLUE GAS PIPE LENGTHS ADISSIBLE ACCORDING TO BOILER TYPE Type of air/flue gas connection L max : aximum length of the connecting pipes in m INNOVENS PRO CA 5 65 90 115 Ø mm Concentric pipes connected to a horizontal air/ C 13x 80/15 16 - - - flue gas vent (PPS) 110/150-9 8 5.9 Concentric pipes connected to a vertical air/ C 33x 80/15 1.5 - - - flue gas vent (PPS) 110/150-11.5 10 9. Pipes C 93x 80/15 - concentric in the boiler room, C 15 - - - 33x 80 - single in the chimney 80/15 5 - - - (combustive air in counter current) (PPS) 110 110/150 110-16 13. 10 Pipes C 93x 80/15 - concentric in the boiler room, C 33x 80 1 - - - - flex in the chimney (combustive air in 110/150 counter current) (PPS) - 16.5 13.5 9. 110 Bi-flow adapter and separate single air/flue C 53 80/15 gas pipes (combustive air taken from outside) to x80 0.5 - - - (Aluminium) 100/150 to x100-3 17.5 16 In the chimney (rigid or flex) B 3P 80 (rigid) 3.5 - - - (combustive air taken from the premises) (PPS) 110 (rigid) - 0 (1) 0 (1) 0 (1) 80 (flex) 1 - - - 110 (flex) - 9.5 (1) 17.5 See page of th product catalogue 010 191 19 193 19 195 196 Attention: aximum L is measured by adding the lengths of the straight air/flue gas pipes and the equivalent lengths of the other sections: - Ø 80 mm (Aluminium): 87 elbow: 1. m, 5 elbow: 0.9 m, inspection T:.8 m, straight inspection: 0.5 m - Ø 100 mm (Aluminium): 87 elbow: 5 m, 5 elbow: 1. m, inspection T: 5.3 m, straight inspection: 0.5 m - Ø 80/15 mm (PPS): 87 elbow: 1.5 m, 5 elbow: 1 m, inspection T:.6 m, straight inspection: 0.6 m, inspection elbow: m - Ø 80 mm (PPS): Inspection pipe for flex pipe: 0.3 m, 87 elbow: 1.9 m, 5 elbow: 1. m, 30 elbow: 0. m, 15 elbow: 0. m, inspection T:. m, straight inspection: 0.3 m, inspection elbow: 0.7 m - Ø 110/150 mm (PPS): 87 elbow: 3.7 m, 5 elbow: 1 m, inspection T:.5 m, straight inspection: 1 m - Ø 110 mm (PPS): 87 elbow:.9 m, 5 elbow: 1.1 m, inspection elbow:.8 m, Inspection pipe for flex pipe: 0.5 m Important: Our gas- boilers have been designed, tested and approved using the air/flue gas pipes proposed in our catalogue, pursuant to the requirements of the prevailing NF EN 83 and XPD 35-30 standards. We guarantee the safety and correct operation of our boilers when they are installed with the approved flue systems and under the conditions recommended in our technical documentation. (1) : ax. height in the flue pipe from the support elbow to the outlet musn't exceed: - 30 m for rigid PPS - 5 m for flex PPS In case of higher lenghts, holding collars must be added by slices of 5 or 30 m. DE DIETRICH THERIQUE S.A.S. with corporate capital of 87 610 57, rue de la Gare - F - 67580 ertzwiller Tel. +33 3 88 80 7 00 - Fax +33 3 88 80 7 99 www.dedietrich-heating.com Sustainable Comfort Réf. 300078-09/010-10309