Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

Similar documents
Mathematical Simulation of Longan Fruit Drying

Evaluation of Technology Transfer to Rural Communities for Drying Using Lpg and Solar Energy Cabinet Dryer

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

Specific Energy Consumption of Heat Pump Drying System

Mango Sheet Drying by the Solar Dryer Combine with Electric Coil

Solar Drying Techniques And Performance Analysis: A Review

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

PERFORMANCE OF FORCED CONVECTION EVACUATED TUBE SOLAR GRAIN DRYER. BOOKER ONYANGO OSODO B. Ed.(TECH); M. Phil (Tech. Ed) (J98/25749/2011)

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Study of air circulation inside the oven by computational fluid dynamics.

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

Drying Parawood with Superheated Steam

Fluidised-Bed Paddy Drying

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Available online at I-SEEC Proceeding - Science and Engineering (2013) 19 26

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Effect of Vacuum Cooling Operation Parameters on Cooling Time and Weight Loss of Chinese Cabbage

Corn drying experiments by pilot dryer

Review Article Solar Drying Technology: Potentials and Developments

A study of Transient Performance of A Cascade Heat Pump System

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

Development of a Commercial Scale Must Flow Paddy Dryer

Cassava Chip Drying by Using a Small-Scale Hot-Air Microwave Oven

Variable far infrared radiation (VFIR) technique for cubic carrot drying

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER

Development of Rotating Tray Dryer and Study of the Hot Air Flow Pattern with Computational Fluid Dynamics

Performance Evaluation of Paddy Rice Pneumatic Dryer

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

Experimental Investigation of an Indirect Evaporative Cooler Consisting of a Heat Pipe Embedded in Porous Ceramic

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

A Study of Drying Uniformity in a New Design of Tray Dryer

Purdue e-pubs. Purdue University

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Key Words: Microalgae; Solar Dryer; Exergy Analysis; Energy Analysis;

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Compression of Fins pipe and simple Heat pipe Using CFD

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Use of heat pump dehumidifiers on industrial drying of chili

Performance of a small-scale greenhouse solar dryer for drying long peppers of Ban Khokamin Community Enterprise Loei Province, Thailand

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

ROTATION-PULSED FLUID BED SALT DRYER. Todor Djurkov

PART I - MODELING DRYING OF THREE-DIMENSIONAL PULP MOLDED STRUCTURES - EXPERIMENTAL PROGRAM

VAPOR COMPRESSION HEAT PUMP USING LOW TEMPERATURE GEOTHERMAL WATER: A CASE STUDY OF NORTHERN THAILAND

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

DRYING TECHNOLOGY A high efficiency dryer with a unique design. Presented by Mohamed LAMMI

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE

A Regional Research and Dissemination Programme. Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

PERFORMANCE EVALUATION OF A DRYER FOR PROCESSED LOCUST BEAN CONDIMENTS

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

Performance Enhancement of Inclined Bubbling Fluidized Bed Paddy Dryer by Design Modification

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Helicoil and Shell-Tube Heat Exchanger. Abdullah AlThomairi, Ahmed Sajjad, and Faris AlShuaibi. October 25, 2014

Design, Construction and Testing of Simple Solar Maize Dryer

AN EXPERIMENTAL INVESTIGATION INTO THE EFFECT OF THERMOSTAT SETTINGS ON THE ENERGY CONSUMPTION OF HOUSEHOLD REFRIGERATORS

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Design and Optimization of Domestic Solar Dryer

Effect of Relative Humidity on Oven Temperature of Locally Design Solar Carbinet Dryer

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Drying of agricultural products using forced convection indirect solar dryer

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Asian Journal on Energy and Environment

Performance Evaluation of Reversible Air Flow Drying in Circulating Dryer

Small Scale Pilot Plant Thermal Dryer for Sewage Sludge Dewatering System A Preliminary Study

Thermal Performance Of Low Cost Solar Bamboo Dryer

Comparison of Energy and Cost Analysis of Two Different Industrial Corn Drying Plants Using Solid Fuel

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

INFLUENCE OF DIFFERENT TEMPERING PERIOD AND VACUUM CONDITIONS ON THE RICE GRAIN BREAKAGE IN A THIN LAYER DRYER

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Global Journal of Engineering Science and Research Management

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Performance Investigation of a Natural Convection Grain Dryer for Paddy Drying

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

A study of radiant cooling for a room with daytime application in tropical climate

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

Numerical study of heat pipe application in heat recovery systems

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

An Experimental Study on Drying of Pistacia Terebinthus in a Fixed Bed Dryer

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Drying Kinetics and Inversion Temperature in a Low-Pressure Superheated Steam-Drying System

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Transcription:

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina Department of Mechanical Engineering, Faculty of Engineering, King Mongkut s University of Technology Thonburi, 126 Prachauthit rd., Bangmod, Thungkru, Bangkok 10140, THAILAND Tel: +66 08 6230 0620, E-mail: sayompon.sri@hotmail.com Atikorn Wongsatanawarid Department of Mechanical Engineering, Faculty of Engineering, King Mongkut s University of Technology Thonburi, 126 Prachauthit rd., Bangmod, Thungkru, Bangkok 10140, THAILAND Tel: +662 470 9265, E-mail: atikorn.won@kmutt.ac.th Abstract This research study is developing alongside with Royal project in Chiang-Rai province. The objective is exactly aim to reduce the energy usage and production cost of drying process which is used typically for several products of highland area for example flower teas, fruits and vegetables. The study evaluates the drying performance of the conventional drying oven of 60 kg batch size, rather than that we introduce the developing of drying oven designed for better velocity distribution using computational fluid dynamics model in enhancing performance of the oven. The heat sources are performed by indirect heating hot water to air using fin-tube heat exchangers in comparison to a heat pump combined heat pipe system. The oven sizes of 0.4 m in width, 0.45 m in height and 0.6 m long with 6 trays. Drying process is controlled for finished products with 6-7 moisture percentages in dry basis. The results showed that evaporation rate of the indirect hot air dryer and the heat pump dryer were 0.15 and 0.72 kg of moisture/hr with specific energy consumption of 147.3 and 168 MJ/kg respectively. The oven design and developed configuration of the system could be discussed further in details. Keywords: Hot Air Dryer, Heat Pump Dryer, Energy Consumption 1. Introduction Sa-Ngo Royal Project Development Center locates at Mount Sa-Ngo, Sridornmoung, Chiangsan, Chiang-Rai Province was initiated by His Majesty King Bhumibol Adulyadej in 1969. It was introduced to encourage hill-tribe villagers to shift from the cultivation of opium poppies to alternative crops. Recently, the Sa-Ngo Royal Project supports farmers to plant Chamomile and Chrysanthemum as majority products. They harvest the fresh products from farmers to produce Chamomile tea and Chrysanthemum tea using drying processes. The old fashion oven size shown in Figure 1 was 1 m long, 2 m wide and 1.6 m high, with 10 trays and a loading capacity of about 60 kg of fresh flower per batch. The Chamomile flower drying program has 2 steps. First drying step that Chamomile flowers are heated up to Corresponding author 189

80 o C and holing for 4 hours then they are kept at 40 o C for another 8 hours. Chrysanthemum flower drying process is also run by the same oven size. The Chrysanthemum flower drying is carried out by 2 methods. One Chrysanthemum flowers is dried at 40 o C for 12 hours. The second method is that Chrysanthemum flowers are grouped in disc shape then they are steamed for 10 seconds in believing that short steam heating will rush up their color. Then wet bunches of Chrysanthemum are dried at 40 o C for 24 hours. Figure 1: Drying Oven of Sa-Ngo Royal Project Development Center. Basically, the oven was simply built without any engineering design that leads to high energy consumption and takes very long time for processing. During the drying process, they have to open the oven to rearrange the trays due to a big variation of temperature in the chamber. Therefore opening the door could drop the temperature in the chamber this consumes more fuel in compensate. Computational fluid dynamics (CFD) have been widely used for predicting the fluid flow pattern in drying chambers (Norton and Sun, 2006). To design a fruit cabinet dyer with obtaining a uniform distribution of drying air flow and temperature, Amanlou and Zomorodian (2010) used CFD for predicting the air velocity and temperature in drying chamber. Rujininnat (2001) had designed and evaluated drying performance of a cabinet dryer using LPG as a direct heat source for drying air. The drying conditions were the drying air temperature 60 o C, the airflow rate of 0.95 m 3 /s and air recycle of 81.6 %. To improve the energy utilization and reduce the energy cost per unit mass in traditional longan fruit drying, Tippayawong et al (2009) introduced a novel forced draft and recirculating air dryer. It was found that the same mass of dried longan fruit produced, specific energy utilization, fuel cost and operating cost were reduced by more than 42 %, 45 % and 27 % respectively. Teeboonma, 190

Tiansuwan and Soponronnarit (2003) recommended the most important factors when examining the optimum conditions of heat pump fruit dryers (HPD) and for minimizing HPD cost are recycle air ratio, evaporator bypass air ratio, airflow rates and drying air temperature. Nirubon and Tul (2003) studied the performance of a combined heat pump-heat pipe dryer and compared the difference between a drying process using heater and a combined heat pump-heat pipe. Nomenclature DR drying rate, kg/h SEC specific energy consumption, MJ/kg LHV lower heating value for fuel, J/kg m f m w h mass of fuel used, kg mass of moisture lost, kg drying time, hour The objectives of this research were to design the new drying oven by using CFD and evaluated drying performance of new drying oven that the heat sources are performed by indirect heating hot water to air using fin-tube heat exchangers in comparison to a heat pump combined heat pipe system. 2. Methodology 2.1 Design improvement The new drying oven was newly designed based on; (i) Heat source: A new drying oven is designed in compatible with various heat source such as LPG burning, Agriculture waste burning and also hot air from heat pump system using indirect heating method, however, in this study LPG burning is our priority. (ii) Fluid dynamics: Hot air in a dryer chamber is designated flow and direction by means of force convection which give higher drying rate than the present oven. (iii) Thermal insulation: Drying cabinet and connecting hot water pipes are well insulated to prevent excessive heat loss. With a well insulated system, a narrower temperature fluctuation inside the dryer could be obtained, as well as variation of temperatures in a layer can be greatly reduced; and (iv) Air side control: Thermocouples were installed at inlet and exit to measure the temperature and relative humidity of drying air. This was simpler and more convenient to allow control of the drying conditions and process fine tuning. 191

2.2 Indirect hot air dryer system Figure 2 illustrates the new system design. It consisted of a hot water system and a drying chamber. The hot water system consisted of two fin-tube heat exchangers, a heat exchanger direct heated with firing of LPG using high efficiency self-respirating burner. A hot water pump of 1 hp electrical motor flows hot water through the second heat exchanger installed at upstream of drying chamber. There was a 0.5 hp of centrifugal fan generated hot air flow throughout the oven size of 0.4 m in width, 0.45 m in height and 0.6 m long with 6 trays. The piping lines were all insulated with 25 mm-thick of EPDM rubber. All ducts were tightly insulated with 25 mm-thick cellular glass insulation cladding with galvanized sheets. Figure 2: An indirect hot air dryer. 2.3 Heat pump combined heat pipe heating system In figure 3, the heat pump system was using reverse refrigeration cycle of 36,000 Btu/hr combined with a heat pipe in front of the condenser. With normal operation of the R-22 cycle it can generated maximum of hot air at condenser outlet of 52 C. The heating system was installed to the oven size of 1 m in width, 1.7 m in height and 1.4 m long with 24 layers of tray. This is comparative study of drying process in identical of inlet condition of the oven in terms of drying rate and energy consumption. The system piping and ducting were also well insulated with EPDM close cell rubber in preventing heat loss in the same level. 2.4 Test procedure and evaluation The experimental program includes the influences of various operating parameters on the dryer performance and drying characteristics of the marigold flower as an example. The target point is reducing the product moisture to 6 % in a dry basis. Table 1 lists the conditions of the experimental carried out in the present work. 192

Figure 3: A heat pump combined heat pipe dryer. Table 1: The experimental conditions for marigold drying in comparative study. Investigating parameters Indirect hot air dryer Heat pump-heat pipe dryer Surface load (kg/m 2 ) 3 3 Ambient temperature ( o C) 33.2 32.6 Ambient relative humidity (%RH) 63.5 62.3 Inlet drying air temperature ( o C) 51.7 51.3 Inlet drying air relative humidity (%RH) 22.9 19.7 Average air velocity (m/s) 1.64 0.91 Bypass air (%) 0 80 Drying rate is defined as the evaporation mass of moisture from the products divided by the drying time. m w DR (1) h Specific energy consumption is defined as the summation of energy used including electrical and thermal energy used per unit mass of evaporation moisture. As for the LPG burning, the SEC could be obtained by; SEC m LHV f (2) m w 193

3. Results and discussion 3.1 Drying characteristic The experimental results of the indirect hot air dryer showed that the average temperature of inlet hot water (T1) was 94.2 o C, the outlet hot water (T2) was 77.2 o C, the drying (T3) was 51.7 o C and the e ambient (T4) was 32.6 o C as shown in figure 4. In figure 5 demonstrated the variations of relative humidity at inlet and outlet of the drying chamber in comparison with ambient as a function of drying time. Figure 4: Experimental inlet and outlet temperatures of the indirect hot air dryer. Figure 5: Inlet and outlet relative humidity of the indirect hot air dryer in the experiment. 194

The experimental results of the heat pump combined heat pipe dryer of the average temperature of air at evaporator inlet (T1), condenser inlet (T2), drying temperature (T3) and ambient temperature (T4) were 23.5, 35.2, 51.3 and 33.5 in degree centigrade respectively. The temperature plots with time as shown in figure 6. Figure 7 shows the variations of relative humidity at inlet and outlet of the drying chamber as a function of drying time. Figure 6: Experimental inlet and outlet temperatures of the heat pump-heat pipe dryer. Figure 7: Inlet and outlet relative humidity of the heat pump-heat pipe dryer in the experiment. 195

The drying rate data was collected during the process for fix amount of the sample. The sampling was taken at every hour from each tray during the process. The results data were tabulated for indirect hot air dryer and heat pump combined heat pipe dryer in table 2 and 3 respectively. The highlighted data was showing that it was achieved to the target weight. Table 2: The marigold was dried by using the indirect hot air dryer. Time (hr) Marigold weight (kg) 1 2 3 4 5 6 0 0.288 0.290 0.290 0.290 0.290 0.302 1 0.220 0.216 0.210 0.218 0.238 0.248 2 0.172 0.166 0.158 0.176 0.198 0.212 3 0.132 0.132 0.122 0.146 0.170 0.186 4 0.104 0.102 0.094 0.124 0.144 0.162 5 0.080 0.078 0.072 0.096 0.122 0.144 6 0.062 0.058 0.056 0.080 0.104 0.118 7 0.052 0.048 0.040 0.066 0.090 0.106 8 0.044 0.036 0.034 0.056 0.072 0.088 9 0.030 0.030 0.022 0.046 0.058 0.074 10 0.030 0.026 0.022 0.040 0.056 0.068 Table 3: The marigold was dried by using the heat pump-heat pipe dryer. Time (hr) Marigold weight (kg) 1 2 3 4 12 0.459 0.420 0.739 0.718 14 0.359 0.340 0.579 0.558 16 0.339 0.330 0.479 0.458 18 0.319 0.320 0.379 0.358 3.2 Specific energy consumption Table 4 presents comparison of the indirect hot air dryer and the heat pump combined heat pipe system dryer. From our findings, the average drying time of the indirect hot air dryer was 8 hours, the average drying time of the heat pump combined heat pipe system dryer was 12 hours, the drying rate of indirect hot air dryer and the heat pump combined heat pipe system dryer were 0.15 and 0.72 kg of evaporated water/hr respectively, the specific energy consumption of the indirect hot air dryer was found to be 147.3 MJ/kg water evaporated and the specific energy consumption of the heat pump combined heat pipe system dryer was 196

found to be 168 MJ/kg water evaporated. It should be noted that the energy consumption of heat pump combined heat pipe system was electricity then the conversion here was not include any consideration of second law of thermodynamics then the energy quality was not taken into account. Table 4: The comparison of the indirect hot air dryer and a heat pump-heat pipe dryer. Title Indirect Heat pump Average drying time (h) 8 12 Drying rate (kg/h) 0.15 0.72 Specific energy consumption (MJ/kg) 147.3 168 4. Conclusion In this study, the developing of drying oven designed for better velocity distribution using Computational Fluid Dynamics model in enhancing performance of the oven. The performance of the indirect hot air dryer was compared with the heat pump combined heat pipe system dryer. Improvement in drying time was successfully demonstrated. However, the complexity of the system design was not discussed here. The batch size of experimental study was also largely difference. Regarding to the experimental resulted, we would inform that the hot air dryer using LPG burning was performed comparably to the heat pump combined heat pipe system in the view point of energy consumption. ACKNOWLEDGMENT We are gratefully thanks to Pilot Plant Development and Training Institute, King Mongkut s University of Technology Thonburi for vastly funding support. We are also appreciated in always kind and hospitality help on site of Sa-Ngo Royal Project Development Center in Chiang-Rai. We would give greatly thanks to Asst.Prof.Dr.Wishsanurak Wechasatol for project sharing and comments. REFERENCES Norton, T., Sun, D.W. (2006) Computational fluid dynamics (CFD) an effective and efficient design and analysis tool for the food industry: a review, Trends in Food Science and Technology, 17, 600 620. Amanlou, Y. and Zomorodian, A. (2010) Applying CFD for designing a new fruit cabinet dryer. Journal of Food Engineering 101, pp.8-15. Rujininnat S. (2001) Fruit Drying Using LPG-Fuel Tray Dyer. A Research Project Submitted in Partial Fulfillment of the Requirement for the Degree of Master of Engineering. 197

Tippayawong, N., Tantakit ti, C., Thavornun, S., Peerawanitkul, V. (2009) Energy conservation in drying of peeled longan by forced convection and hot air recirculation. Biosystems Engineering, 104, 119-204. Teeboonma, U., Tiansuwan, J. and Soponronnarit, S. (2003) Optimization of heat pump fruit dryers. Journal of Food Engineering 59, pp.369-377. Kanjanangkoonphun, N. and Maneewattana, T. (2003) Study on the performance of a combined heat pump-heat pipe dryer. The 17 th Conference of Mechanical Engineering. 198