Evaporative Cooler 10 litre

Similar documents
Ceiling Sweep Fan Assembly Instructions

PORTABLE AIR CONDITIONER

Mobile Air Conditioner Instruction Manual Model TC-N9KM

10L Evaporative Cooler with Timer

Dual-Hose Portable Air Conditioner User Manual

Table of contents. Installing the charcoal filter 18 Cleaning the prefilter 18 Long term storage 18 Troubleshooting 19 Limited warranty 22

7Litre Evaporative Cooler With Remote

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

PORTABLE AIR CONDITIONER

Local air conditioner

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

OWNER'S MANUAL MODEL: P-08PE P-12PE. For any service needs, call

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Instruction Manual Item No.: V~, 60Hz

INSTRUCTIONS FOR CARBON INFRARED HEATER

Instruction Manual. Portable Air Conditioner

AC-12200E Portable Air Conditioner

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

WCD-200W Water Dispenser

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

Instruction Manual Item No.: V~, 60Hz

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Air Conditioner

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

12,000 BTU Evaporative Portable Air Conditioner

AH-450B Oil-Filled Radiator Heater OWNERS MANUAL

ARTICA. 8000Btu. Room Air Conditioners Portable Range

AIR COOLER OPERATING INSTRUCTIONS MODEL NO: ARC-30 ARC-30. Instruction Manual

SERVICE NUMBER ( )

FAN HEATER FH118 User Manual

Portable Air Conditioner

PORTABLE AIR CONDITIONER

Utopian Portable A/C

Mobile Type AIR CONDITIONERS (LOCAL AIR CONDITIONERS)

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

OWNER S MANUAL Compact Portable Refrigerated Air Conditioner CP35CW1

40cm Pedestal Fan with Remote Control

INSTRUCTIONS AND WARRANTY

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Portable Air Conditioner

P O R T A B L E Air Conditioner

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

ENGLISH INSTRUCTION MANUAL PLM 9KE-410 /12KE-410 /15KE-410 PLUS HEATER VERSIONS

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

EH1688. Over Door Heater & Fan Chauffage de Porte & Ventilateur

Radiant Heater. Instruction Manual QH-200 N13275

EVAPORATIVE AIR COOLER SERVICE MANUAL

Portable Air-conditioner Use and Care Manual

AH-600 Baseboard Heater

AF-1000 Series Evaporative Cooler OWNERS MANUAL

Mobile Evaporative Cooler EVA-12

EH0533 Indoor Climate Control

2400W Ceramic Tower Heater

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

AH-450B Oil Filled Heater OWNERS MANUAL

IMPORTANT SAFETY INSTRUCTIONS

Electric Fireplace Insert with Heater OWNER S MANUAL Model No. FP404R-Q

OT600E Tower Fan with Remote Control

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Portable Air Conditioner USER MANUAL

IMPORTANT INSTRUCTIONS READ & SAVE

MODEL: DC10RCDH / DC12RCDH

Portable Air Conditioner

Model No.: PS08-01 PS10-01 Ref: KY80 KY100


Electric Fireplace Insert with Heater

OWNER S MANUAL. ClimateMaster Portable Refrigerated Air Conditioner. (English) (CM9CW1)

EH " (40cm) Remote Control Wall Fan

Aquarius Cordfree 1.7L Kettle KAK36. Instruction Booklet

Operating Instructions

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

Installation & Operating Instructions

PANEL HEATERS OPERATING INSTRUCTIONS

OWNER S MANUAL. Portable Refrigerated Air Conditioner. CP12CW2 (English) (CP12CW2)

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Portable Air-conditioner

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

Please read and keep manual to ensure safe and effective use of this Appliance HOUSEHOLD USE ONLY

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

Low Profile. Baseboard Heater

Portable Evaporative Air Cooler User Manual Read and save these instructions before use

compact ceramic heater

&Fan. Instruction Manual. ULTRASlimline Heater. Model: (with remote control) Voltage: 120V AC Frequency: 60 Hz Power: 1500 W

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

Electric Fireplace. Electric Fireplace

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

IMPORTANT SAFETY INSTRUCTIONS

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

EH0554 Indoor Climate Control

SEVILLE KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 18152AU 18152AU_IB_FA_240712

YORK KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 20431AU 20431AU_IB_FA_190314

Transcription:

Evaporative Cooler 10 litre CWEC01 Instructions Manual Important! Please read these instructions carefully. Due to continuous research and development the specifications herein are subject to change without notice. CWEC01 Instructions copy.indd 1

SAFETY INSTRUCTIONS Keep the ice packs (supplied) away from the children as they contain chemical based crystals. DO NOT use this unit for functions other than those described in this instruction manual DO NOT tilt the unit. Always keep in upright. Position on a flat and stable surface, where it cannot be easily knocked over. Take extra care when operating DO NOT cover or obstruct the air filter inlet or outlet grilles DO NOT use the unit in a wet room, such as a bathroom or laundry DO NOT sit or place articles on the unit DO NOT touch the unit with wet hands or bare feet DO NOT let chemical substances come into contact with the unit DO NOT use the unit in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol etc. DO NOT use the mains plug to start and stop the unit DO NOT pull the supply cord or place it near a heat source. Always unwind the cord completely to avoid overheating. If the supply cord is damaged it must be replaced by the service agent or a similarly qualified person, in order to avoid a hazard DO NOT allow children to play with this appliance. This appliance is not intended for use by children or infirm persons without supervision. DO NOT conduct repairs on this unit. It has been built in accordance with relevant safety and performance standards. An electrical specialist must carry out all repairs. If the power cord is damaged, it must be replaced by a qualified electrician DO NOT use the unit without the filter fitted DO NOT allow objects to enter any ventilation or exhaust other than ice or water as specified in these instructions This unit is intended for indoor use only. ALWAYS unplug the unit from the mains before maintenance or cleaning ALWAYS use the switch on the control panel to start and stop the unit ALWAYS keep a clearance of at least 20cm from walls furniture and curtains ALWAYS turn off and unplug the unit when not in use ALWAYS switch off, and unplug the unit before filling up with water or ice Adequate clean water should be put into the water tank within the water level limits shown on the level indicator. Should you wish to move the unit any great distance, or before storing it, always drain the water from the tank using the plug provided at the bottom of the unit. When draining the water tank always do this over a bucket, outside so that water does not damage the carpet or flooring ENERGY SAVING TIPS Use the unit in the recommended room size of up to 20m 2 (assuming standard 2.4m ceiling height) Do not locate the air conditioner where furniture or other objects can obstruct the air flow. Keep blinds/curtains closed during the sunniest part of the day Close the fireplace damper, floor and/or wall registers, so cool air does not escape through the chimney or duct work Keep the air filter clean Set the unit to maximum cooling and high speed ventilation for the initial startup, then adjust the unit down to a more comfortable setting as required 2 CWEC01 Instructions copy.indd 2

IDENTIFICATION AIR CONDITIONER 1. Control panel 2. Air inlet filter 3. Cool air outlet 4. Horizontal louvers 5. Vertical louvers 6. Front body 7. Water level indicator 8. Water entrance 9. Caster wheels 10. Carry handle 11. Chiller bottles 12. Remote control 13. Ice Tray Door 2. Air inlet filter 12. Remote control 8. Water entrance 11. Chiller bottles 13. Ice Tray Door 1. Control panel 10. Carry handle 3. Cool air outlet 4. Horizontal louvers 5. Vertical louvers 6. Front body 7. Water level indicator 9. Caster wheels CONTROL PANEL 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 1. Timer switch 2. Oscillate switch 3. Mode Switch 4. Power OFF switch 5. Fan Speed Switch 6. Cool switch 7. Power On switch 8. Time indicators 0.5 Hr, 1 Hr, 2 Hr, 4 Hr 9. Oscillate Indicator 10. Mode indicators : 1 Normal, 2 Breeze, 3 Circulate 11. Remote sensor window 12. Fan speed indicators : low, medium, high 13. Cool indicator 14. Power indicator 3 CWEC01 Instructions copy.indd 3

OPERATION Turning ON/OFF Press the power ON button to turn on and OFF button to turn off the evaporative cooler. Setting Fan SPEED Press the speed button to set fan speed. Press the button repeatedly to change the fan speed Low, Medium and High Setting the Mode Change the mode to the desired type (Normal, Breeze and Circulate) by pressing the mode switch repeatedly. Modes Explained 1. Normal mode The fan speed remains constant at set speed (Low or Medium or High). This mode is recommended normal operation. 2. Breeze mode The fan speed varies randomly (Low, Medium, High and off) giving the effect of natural breeze. It is recommended to set the fan speed at high under this mode for better result. 3. Circulate (sleep) mode The fan speed switches on and off at set speeds thus saving energy during night. It is recommended to set the fan speed at low under this mode for quieter performance and less energy consumption. Cool Function Cool switch is used to operate the automated water pump system. This function is recommended for higher/ efficient cooling effect under any mode. Oscillate Function (Regulating air flow direction) Oscillate function switch is used to direct the air flow automatically from horizontally (side to side) by means of the vertical louvers. This can be done while the unit is in operation. To control the air flow direction via the horizontal louvers adjust louvers manually (louvers interlocked). Setting Timer Set the Timer to the desired operating time (0.5 Hour to 7.5 Hours) by pressing the Timer switch repeatedly. When the set time has been reached the unit will shut off automatically. * Please make sure sufficient water is in the storage tank before operation. Refer to Storage & Drainage section for details. 4 CWEC01 Instructions copy.indd 4

Remote Control This remote control requires 2 x AAA alkaline 1.5V batteries. To install the batteries, remove the battery cover then insert the batteries in right polarities (+/-). Replace the battery cover before use. The remote control has all the same functions as the buttons on the control panel of the air cooler. To use the remote control, make sure that the air cooler unit is plugged into the mains supply, then point the remote at the sensor on the top of the main unit, and press the desired button. The remote control operating range is 7 meters. It is ideal not to have any obstacles between the remote and the sensor. STORAGE AND DRAINAGE Sufficient water needs to be stored in the storage tank (at the bottom of the unit) to ensure supply of cool air. Before storing water in the unit, switch the unit off and unplug from the mains supply. Water is poured into the storage tank through the water entrance on the side of the unit as shown below to appropriate level (from the water level indicator in the front of the unit). Make sure that the water storage tank is re-filled once it runs out. 1. 2. 3. 4. 5. 6. 7. To drain the water when the unit is not in use. 1. Position a water tray flat on the floor, beneath the drain hole. 2. Unscrew the drain cap at the bottom of the unit and then remove the water plug from the drain hole, allowing the water to drain out. (refer to figure below) 3. When the drain tray is almost full replace the water plug into the drain hole and empty the tray. 1. Mode 2. Louver Oscillation ON/OFF 3. Power ON 4. Cool ON/OFF 5. Fan Speed 6. Timer OFF 7. Power OFF Drain cap location 5 CWEC01 Instructions copy.indd 5

Chiller Bottles The chiller bottles provided with the unit must be filled with water and must be allowed to freeze in a refrigerating unit (in an upright position) prior to their use in the cooler unit. Place chiller bottle into the side water entrance. If desired a length of string can be attached to bottle cap hook provided for easier retrieval. Place bottle in water entrance door and leave string end out when closing the door. Ice Tray For even more effective cooling, fill the ice tray, located at the top of the cooler with cube ice. Fig 1. Fig 2. 6 CWEC01 Instructions copy.indd 6

Cleaning and Maintenance Always switch off and unplug from the mains supply before attempting any kind of cleaning and maintenance. After extended period of use, replace the water in the tank with fresh water. The air filter (only) at the inlet at the rear of the unit can be cleaned if required. The foam filter should be cleaned in a mild soapy solution, then left to dry before replacing. External enclosure can be cleaned with a damp cloth. Cleaning the Air Filters Unplug the power cord. To clean the sliding air filter remove the ice tray door out the top of the unit and remove the sliding air filter from the top. To clean the rear air filter, loosen the screw as indicated and remove the air filter. In a smoky or dusty environment the filters may appear gray after 1-2 months and will need to be cleaned. In conditions without smoke or minimal dust, the filters to be cleaned every 1-6 months depending on the condition of the filters. Wash the air filters with warm soapy water and a soft brush. Place side of filters with the light contact agent facing upwards in the sun for at least 4 hours to re-generate the light contact agent and re-fit it back in the unit. Sliding Air Filter Fig 1. SPECIFICATIONS Model: CWEC01 Wattage: 230-240V ~ 50Hz Input power consumption: 60 Watt Water Capacity: 10 Litres Loosen screw Rear Air Filter Fig 2. 7 CWEC01 Instructions copy.indd 7

Coolway Guarantee Coolway guarantees this product against defects in materials and/or workmanship, under normal domestic use and conditions for 12 months from the date of purchase. Except as otherwise provided for by Trade Practices Act and State Consumer Legislation, this guarantee becomes void if, in the opinion of Coolway: The product has been misused or abused Used in a commercial application Installed incorrectly Modified or installed by an unauthorised person Has been damaged in transit subsequent to purchase Connected to electrical supply not corresponding to the product s specification The product has been used with type of controller not recommended by Coolway. If any part of the product proves defective within the warranty period, such part will be repaired or replaced free of charge at the discretion of Coolway. The purchaser of the fan is to be responsible for: Travel costs incurred where service is requested at premises or at such time outside normal areas or times as defined by Coolway or their authorised agent. Transport and insurance costs if product or parts have to be returned for repair or replacement to Coolway or their authorised agent. Repair of defects not covered by this warranty To claim under this guarantee, the purchaser must produce proof of purchase, plus proof of installation (contractor invoice and contractor licence number). For Service enquiries Phone: (03) 9727 8860 Fax: 1300 360 650 Email: customerservice@coolway.com.au This instruction leaflet is subject to copyright and must not be reproduced, copied or otherwise used in any way or for any purpose without the consent in writing of the owner. CPIN002026/2 8 CWEC01 Instructions copy.indd 8