Fire Resistant Cables

Similar documents
CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Low Voltage Catalogue_Final ai 11/8/09 11:37:27 AM BICC 1 BICC Final Brochure-NEW.indd 1 7/5/10 3:02 PM

PRODUCT RANGE.

FIRE RESISTANT CABLES FP300

Corporate Presentation. 14 June 2009

FIRE RESISTANT CABLES FP400

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

High Performance LSZH Fire Resistant Cable

Steel, Civil, MEP & Telecommunication Infrastructure Service Providers MEP Profile

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

FIRE RESISTANT CABLES FP200 GOLD

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

LSOH Flexible Cables

LV FIRE RESISTANT CABLES

BS /1000V XLPE Insulation LSZH Sheath Cables

Introduction.

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

FIRE RESISTANT CABLES FP200 GOLD

STANDARDS INSTALLATION. Certificate No 077m

THE TRUE FIRE SURVIVAL CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

fire resistant cables

Total Fire Solutions. Includes BS 8519 and the updated BS :

The Quality Connection. BETAflam Fire Resistant Safety Cables

Flame Retardant Overall Screened Instrumentation Cables (multicore)

ENHANCED FIRE PERFORMANCE CABLE

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

FIRE PERFORMANCE CABLE

LSZH Zero Halogen Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Havells Fire Survival Cables

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

WORLDWIDE CABLE EXPERTS

Photovoltaic Cables EN H1Z2Z2-K

10.17 Scope of Accreditation

The world s most trusted cable brand

The world s most trusted cable brand

DNVGL-CP-0401 Edition February 2016

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

Phelps Dodge International (Thailand) Limited. Company Profile

DNVGL-CP-0399 Edition March 2016

Multi-Core Fire Resistant Cable

FIRE RESISTANT CABLES

The safe choice. Now real safety is possible and easy. The evolution of safety. Fire resistant LSOH cables. Ecology Line. Traditional standard cables

Shipboard & Offshore Cables

Cable technology for highest safety requirements

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Tratos Railway Cables

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Caledonian Flame Retardant Coaxial Cables

PRODUCT CATALOGUE Norröna

Catalogue. Instrumentation & Control Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

Catalogue Telecommunication Cables INTRODUCCIÓN

VISION MISSION. To be internationaly renowned customer focused company offering comprehensive solutions and quality products

For Heavy Duty Commercial and Industrial Environments

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Telecommunication Cables

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

Cablosam Tapes for Fire-Resistant Cables

Catalogue Power Cables

SAS Security and Alarm Safety Cables

Caledonian fire Resistant signal & Data cables

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

10.6 Schedule of Accreditation

Comtran Cable. Hub-LINK Cables for Transit Applications

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

OIL & GAS INDUSTRY OTHER INDUSTRIES

Traction Cable Radox 3 GKW

Lloyd s Register Type Approval System Test Specification Number 3

Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Second Issue April See rear cover for applicable countries

DNVGL-CP-0402 Edition February 2016

UK Direction BS7671 BS 8492 BS /01/2018

FIRE PROTECTION SYSTEMS IN BURJ KHALIFA. By NAFFCO Fire Protection

10.6 Schedule of Accreditation

INTERNATIONAL STANDARD

WHAT MAKES PRYSMIAN CABLES DIFFERENT?

CIRCA Ceiling Range. Ceiling products designed to meet a wide range of applications and compliment any ceiling décor

Transcription:

Fire Resistant Cables

Ducab (Abu Dhabi) Factory P.O. Box 9171, Abu Dhabi, UAE Tel: (971-2) 502 7777 Fax: (971-2) 502 7888 email: ducab@ducab.com Ducab Connect P.O. Box 11529, Dubai, United Arab Emirates Tel: (971-4) 808 2500 Fax: (971-4) 808 2599 E-mail: sales@ducab.com P.O. Box 683, Dubai, United Arab Emirates Tel: (971-4) 266 7400 Fax: (971-4) 266 8955 E-mail: sales@ducab.com Ducab-Oman P.O. Box 3542, 112 Ruwi, Muscat, Sultanate of Oman Tel: (968) 24565 177 Fax: (968) 24564 302 E-mail: ducabomn@omantel.net.om JBK-BICC W.L.L. P.O. Box 14039, Doha, Qatar Tel: (974) 442 1924 Fax: (974) 441 9003 E-mail: jbkbicc@qatar.net.qa BICC MET W.L.L. P.O. Box 11413, Manama, Bahrain Tel: (973) 1772 7071 Fax: (973) 1772 8027 E-mail: bicc@batelco.com.bh P.O. Box 39171, Abu Dhabi, United Arab Emirates Tel: (971-2) 644 1155 Fax: (971-2) 644 3338 E-mail: kalazzani@ducab.com

BS7846 LOW VOLTAGE 600/1000V Areas of application for fire resistant cables include: 1. Areas where people will remain in occupation for short time e.g. schools, shopping malls, cinemas etc. 2. Mass transit system e.g. metro, airport terminals etc. 3. High-rise buildings 4. Places where evacuation of people cannot be done iediately in case of fire e.g. large hospitals 5. Services where circuit integrity is of paramount importance under fire conditions 6. Essential safety circuits e.g. fire detection, alarm and evacuation 7. Power supply to equipment used in fire fighting e.g. sprinkler pumps, smoke extractors and fire shutters etc. High Rise Buildings Metro and Underground Tunnels Airports Hospitals

B S 7 8 4 6 LOW VOLTAGE 600/1000V Cable Features Fire Resistant Cable Construction 1 Copper conductor 2 Dual insulation - Mica glass - XLPE 3 LSF Bedding (Low Smoke & Fume. Also known as Low Smoke Zero Halogen - LSZH) Core identification - Standard Red-Black Red-Yellow-Blue Red-Yellow-Blue-Black - Alternative* Brown-Blue Brown-Black-Grey Blue-Brown-Black-Grey *Available on special orders. 4 Galvanised steel wire armoured 5 LSF outer sheath INSTALLATION GUIDELINES Cables Installed in Air It is anticipated that many of the in air installations will be in buildings, and the ratings are therefore given in accordance with IEE Wiring Regulations for Electrical Installations, BS 7671. It should be noted that all ratings for cables run in free air have been based on the assumption that they are shielded from the direct rays of the sun without restriction of ventilation. The rating for cables subjected to direct sunlight should be reduced to take account of this factor and further guidance on this subject is available on request. In order to maintain circuit integrity under fire conditions, it should be ensured that accessories used with cables are also fire rated. Rating factor for ambient air temperatures Air Temperature 25 C 30 C 35 C 40 C 45 C 50 C 55 C Rating Factors 1.02 1.0 0.96 0.91 0.87 0.82 0.76 offers complete cable components and accessories selection for cables.

Technical Data

B S 7 8 4 6 LOW VOLTAGE 600/1000V Introduction Ducab, established in 1979, is the leading manufacturer of electric cables in the Middle East. It is today equally owned by the Government of Abu Dhabi and Government of Dubai. Ducab's aim is to provide electric cables of the highest quality and provide customer service that is unequalled worldwide. Ducab's product range also covers Ducab Smokemaster low smoke and fume cables, Ducab Powerplus MV cables upto 33 kv, LV cables, Instrumentation and Pilot cables, Control and Auxiliary cables, Wiring cables, Lead sheathed cables for the oil, gas, and petrochemical sector. Ducab also offers a complete range of cable components and accessories. Ducab is coitted to providing the customer with total quality. Ducab's quality management system conforms to ISO 9001 : 2000 standards and certified by BASEC. Also, Ducab is the first cable manufacturer in the region to achieve certification to ISO 14001, the international environmental management standard by BASEC. cables: cables are fire resistant armoured cables intended for applications requiring circuit integrity during a fire. Since these cables are used in critical applications, the approval process and certification are vital to ensure necessary performance. cables comply with BS 7846 category F1 and F2 and are LPCB (Loss Prevention Certification Board) approved to the full British Standard. Ducab has taken the view that using LPCB to approve only the basic fire tests such as CWZ and F2 classifications is not sufficient. By seeking full BS7846 approval from LPCB Ducab has proved that it is coitted to go beyond these tests and deliver a superior product with approved materials and manufacturing processes, as well as regular independent assessment and product testing. This ongoing coitment to quality is one of the reasons why our customers have complete faith in Ducab products. In addition to maintaining circuit integrity under fire conditions, cables generate very low smoke and are Halogen free in accordance with BS7846, thus helping to save human life and provide protection for the sensitive equipment. cables also have type approval for the complete range by Lloyd's Register, UK. Key fire performance requirements BS 7846 cable is designed to meet: 1. Flaability: IEC 60332-1 and IEC 60332-3 categories A, B & C. 2. Resistance to fire: C-W-Z of BS: 6387, IEC: 60331 and F-2 of BS: 7846 3. Smoke Emission: IEC 61034-1 & 2 4. Acid Gas Content: IEC 60754-1 & 2, BSEN 50267-1 & 2 Special Features a. Maintains Circuit Integrity for 3 hours under fire condition. b. Zero halogen, low smoke and to flame propagation.

BS 7846 2-Core Fire resistant cables. Two Core Armoured Cables 600/1000 V Grade with stranded copper conductors Nominal conductor area Approximate Diameter Under armour Over armour Overall dia Approximate cable weight Maximum conductor Maximum armour Current rating on perforated cable trays / free air Voltage drop (1φ ΑC) 2 kg/km Amp mv/a/m 600/1000 V Copper power and control cables 1.5* 8.7 10.5 12.4 315 12.1 10.2 29 31 2.5* 9.9 11.7 13.8 385 7.41 8.8 39 19 4* 11.1 12.9 15.0 460 4.61 7.9 52 12 6* 12.1 13.9 16.0 535 3.08 7.0 66 7.9 10* 13.9 15.7 18.0 690 1.83 6.0 90 4.7 16* 15.7 18.2 20.5 920 1.15 3.7 115 2.9 25* 19.7 22.2 24.7 1270 0.727 3.7 152 1.9 35* 21.9 25.1 27.8 1720 0.524 2.6 188 1.35 50 19.5 22.6 25.4 1810 0.387 2.3 228 1 70 22.1 25.2 28.2 2305 0.268 2.0 291 0.69 95 24.5 28.4 31.6 3105 0.193 1.4 354 0.52 120 29.1 33.0 36.4 3820 0.153 1.3 410 0.42 150 31.1 35.0 38.6 4475 0.124 1.2 472 0.35 185 33.4 38.3 42.2 5675 0.0991 0.82 539 0.29 240 38.0 42.9 47.0 7090 0.0754 0.73 636 0.24 300 43.0 47.8 52.2 8570 0.0601 0.67 732 0.21 * Circular conductors, all others are sector shaped Installation conditions for above rating: Ambient Air Temperature 30 o C Conductor operating temperature 90 o C

BS 7846 3-Core Fire resistant cables. Three Core Armoured Cables 600/1000 V Grade with stranded copper conductors Nominal conductor area Under armour Approximate Diameter Over armour Overall dia Approximate cable weight Maximum conductor Maximum armour Current rating on perforated cable trays / free air Voltage drop (3φ AC) 2 kg/km Amp mv/a/m 600/1000 V Copper power and control cables 1.5* 9.2 11.0 12.9 345 12.1 9.5 25 27 2.5* 10.5 12.3 14.4 425 7.41 8.2 33 16 4* 11.8 13.6 15.7 515 4.61 7.5 44 10 6* 12.9 14.7 16.8 610 3.08 6.7 56 6.8 10* 14.8 17.3 19.6 910 1.83 4.0 78 4.0 16* 16.8 19.3 21.8 1110 1.15 3.5 99 2.5 25* 21.1 24.3 27.0 1720 0.727 2.5 131 1.65 35* 23.5 26.7 29.6 2105 0.524 2.3 162 1.15 50 24.9 28.0 30.8 2480 0.387 2.0 197 0.87 70 26.9 30.0 33.0 3145 0.268 1.8 251 0.60 95 30.6 34.5 37.9 4310 0.193 1.3 304 0.45 120 33.9 37.8 41.4 5170 0.153 1.2 353 0.37 150 37.8 42.7 46.5 6555 0.124 0.78 406 0.30 185 42.2 47.1 51.0 7915 0.0991 0.71 463 0.26 240 46.4 51.3 55.6 9815 0.0754 0.63 546 0.21 300 52.8 57.6 62.1 12030 0.0601 0.58 628 0.185 400 58.0 62.8 67.7 14740 0.0470 0.52 728 0.165 * Circular conductors, all others are sector shaped Installation conditions for above rating: Ambient Air Temperature 30 o C Conductor operating temperature 90 o C

BS 7846 4-Core Fire resistant cables. Four Core Armoured Cables 600/1000 V Grade with stranded copper conductors Nominal conductor area Under armour Approximate Diameter Over armour Overall dia Approximate cable weight Maximum conductor Maximum armour Current rating on perforated cable trays / free air Voltage drop (3φ AC) 2 kg/km Amp mv/a/m 600/1000 V Copper power and control cables 1.5* 10.1 11.9 13.8 390 12.1 8.8 25 27 2.5* 11.5 13.3 15.4 480 7.41 7.7 33 16 4* 13.0 14.8 16.9 590 4.61 6.8 44 10 6* 14.2 16.7 19.0 825 3.08 4.3 56 6.8 10* 16.4 18.9 21.2 1065 1.83 3.7 78 4.0 16* 18.6 21.1 23.6 1335 1.15 3.1 99 2.5 25* 23.4 26.6 29.3 2070 0.727 2.3 131 1.65 35* 26.1 29.3 32.2 2550 0.524 2.0 162 1.15 50 26.5 29.6 32.6 3015 0.387 1.8 197 0.87 70 30.7 34.6 38.0 4240 0.268 1.2 251 0.60 95 34.5 38.4 42.0 5420 0.193 1.1 304 0.45 120 38.1 43.0 46.8 6935 0.153 0.76 353 0.37 150 42.8 47.7 51.6 8270 0.124 0.68 406 0.30 185 47.2 52.1 56.4 10000 0.0991 0.61 463 0.26 240 52.5 57.3 61.8 12485 0.0754 0.54 546 0.21 300 58.2 63.0 67.9 15175 0.0601 0.49 628 0.185 400 66.5 72.6 78.0 19800 0.0470 0.35 728 0.165 * Circular conductors, all others are sector shaped Installation conditions for above rating: Ambient Air Temperature 30 o C Conductor operating temperature 90 o C

BS 7846 Multi-Core Fire resistant cables. Armoured Auxiliary Cables 600/1000 V Grade with stranded copper conductors Number of cores Nominal conductor area 2 Under armour Approximate Diameter Over armour Overall dia Approximate cable weight kg/km Maximum conductor Maximum armour Current rating on perforated cable trays / free air (Multi circuit operation) Amp Current rating on perforated cable trays / free air (Single circuit operation) Amp Voltage drop (3φ AC) mv/a/m 600/1000 V Copper auxiliary control cables 7 1.5 12.0 13.7 15.9 485 12.1 7.5 19 29 27 12 15.8 18.3 20.6 820 12.1 4.0 16 29 27 19 18.6 21.1 23.6 1060 12.1 3.5 14 29 27 27 22.4 25.6 28.3 1525 12.1 2.3 12 29 27 37 25.2 28.4 31.1 1840 12.1 2.0 11 29 27 48 29.0 32.2 35.1 2240 12.1 1.8 10 29 27 7 2.5 13.8 15.5 17.7 610 7.41 6.3 25 39 16 12 18.3 20.8 23.3 1040 7.41 3.5 21 39 16 19 21.6 24.8 27.5 1525 7.41 2.3 18 39 16 27 26.1 29.3 32.2 1980 7.41 1.9 17 39 16 37 29.4 32.6 35.5 2425 7.41 1.7 15 39 16 48 33.9 37.9 41.1 3260 7.41 1.2 14 39 16 7 4 15.6 18.0 20.3 885 4.61 4.0 33 52 10 12 20.8 24.0 26.5 1450 4.61 2.3 28 52 10 19 24.6 27.8 30.5 1940 4.61 2.0 24 52 10 27 29.8 33.0 36.0 2560 4.61 1.7 22 52 10 37 33.6 37.6 40.8 3445 4.61 1.2 19 52 10 48 38.8 42.8 46.2 4240 4.61 1.0 17 52 10 * Multi circuit means all conductors are loaded equally and operating in close vicinity Installation conditions for above rating: Ambient Air Temperature 30 o C Conductor operating temperature 90 o C

Installation Guidelines Precautions to be observed for extensions or alterations with existing & new color scheme. Single Phase Existing Color Code New Harmonised Color Code Red L L Brown Black N N Blue Three Phase Red L1 L1 Brown Yellow L2 L2 Black Blue L3 L3 Grey Black N N Blue