Service Manual For electronic dual temperature zone wine cellar Includes DWC282 / 283

Similar documents
SERVICE MANUAL FOR MODEL RM-10

Product Information and Technical Guide

Operating Instructions

SERVICE MANUAL FOR MODEL RM-49

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

SERVICE MANUAL FOR MODEL RM-26

Owner s Manual Window Air Conditioner

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Troubleshooting(TC32G)

Table of Contents. Notice: Any maintenance should be returned to the dealer or factory! Attention: Please read this instruction carefully before use.

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

AWR-460DB 46 Bottle Built-In Compressor Wine Cooler

Operation regulations must be strictly obeyed.

USER MANUAL KBU-50 /120 /170 TWO-TEMP ZONES MODELS

Double Door Over 70. Service Manual. Models: F NMTZH 821 F T F NMTZH 822 F T

NO. 15FD-742 ISSUED: AUG. 10, 2007 REVISED: SEP. 30, 2013 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-30A KM-35A KM-50A KM-75A MODEL SERVICE MANUAL

Product Information and Technical Guide

Product Information and Technical Guide

Thermal Electric Wine & Beverage Chiller. Model: WC-20TL (20 Standard Bottle Capacity) Instruction Manual

USER S MANUAL HSC-14/18/24/24A

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

Freestanding Wine Cooler Instruction Manual

Refrigerated Compressed Air Dryer

Refrigerator KE T

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Tornado Operations & Maintenance Manual

Read and save these instructions

A/C-HEATER SYSTEM - MANUAL

Wine Cooler CVD121V/CVD131V/CVD130/CVD120

Room Air Conditioner Service and Parts Manual

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

FTM419A01W USER S MANUAL FROST FREE REFRIGERATOR

FM740 INSTRUCTION MANUAL VACUUM CLEANER. Contents HOUSEHOLD USE ONLY

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

Glass Door Merchandiser. Model RM-49

KF Fridge / Freezer User Guide

INSTALLATION & OPERATING INSTRUCTIONS

Split Floor-Mounted Cooling System Operation Care Installation Manual

Product Information and Technical Guide

Ocean Breeze Split System. General Installation Manual. Ocean Breeze 2951 SE Dominica Terrace Stuart, Florida Tel:

Glass Door Merchandiser

Product instruction manual Easymount Wide Format Laminators

SERVICE MANUAL REFRIGERATION

EURO APPLIANCES BY EUROSTYLE GROUP

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

Part 5. Troubleshooting. 1. Normal Air Conditioner Phenomenon Air Conditioner Protection in Common

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

Glass Door Merchandiser. Model RM-45-SD

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

HAKKO 703B REWORK SYSTEM TROUBLESHOOTING GUIDE

Service Manual Inch Undercounter Refrigeration

TECHNICAL INFORMATION Touchtronic Clothes Dryers

COOLING SOLUTIONS. A Division Of CAG Purification Inc. SPOT COOLER MANUAL. 10,000 BTU to 60,000 BTU Capacities IS T E D ISO 9001, ISO 14001

TABLE OF CONTENTS FOR YOUR SAFETY

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

442 Chapter 16. Figure 16-5 Gas leak detection

Room Air Conditioner SERVICE MANUAL MODEL : LW6013ERY3. CAUTION

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

LONG BEACH 52" outdoor fans

REFRIGERATOR USER S MANUAL MODEL: HS-306LN

KSD-35 DR11 KUE-35 DVN11

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

- 1 - Updated on 18 March, 2010

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

SELF-PRIMING JET PUMPS

Instruction Manual. Please read these instructions fully before using this product. Smart Living Steam Mop. With all new design enhancements

DUST COLLECTOR OPERATION AND SAFETY INSTRUCTIONS FM230 CAUTION: READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

C C C-600 INSTRUCTION MANUAL ICE CUBES MACHINE. (including: exploded views, part list & diagrams) CUISIMAT

Trouble Shooting Guide RAA, 1-phase (D3627)

NO. F ISSUED: JUN. 18, 2008 REVISED: JUN. 17, 2011 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-100A KM-125A MODEL SERVICE MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

HT-2 / 9600 Series Control Contents

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Service Manual & Installation Manual

Fundamental safety warnings

Trouble Shooting Guide PAA, 1-phase (D3731)

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

AWR-460DB 46 Bottle Built-In Compressor Wine Cooler

Thermo 230 / 231 / 300 / 301 / Troubleshooting

Transcription:

Service Manual For electronic dual temperature zone wine cellar Includes DWC282 / 283 2 / 18 This is a service guideline for possible failure and repair. Warning: before attempting any cleaning or maintenance this unit MUST be disconnected from the supply, to prevent electrical shock Preparation before maintenance Equipment 1/ Small bench Vise 2/ Set of Phillips head screwdrivers 3/ Seal pliers 4/ Electrical Multi meter 5/ Amp meter (5A) (caliper cable type) 6/ Electrical soldering iron 7/ Wire strippers 8/ Scissors 9/ Vacuum pump 10/ Soldering iron for copper pipes Cooling system fault How to Evaluate the fault... (Page 3) How to repair the fault (Page 3) How to remove the air duct board... (Page 3) Diagram showing the front side soldered joints.. (Page 8) Diagram showing the rear side soldered joints (page 8) Heating system fault How to Evaluate the fault.(page 9) How to repair the fault. (Page 9) Noise problems Compressor noise... (Page 9) Fan noise...(page 9) Refrigerant jet noise...... (Page 12) Capillary vibration noise....... (Page 12) Oil jam noise......(page 12) Evaporator freezing problems....... (Page 12) Unstable internal Temperature...... (Page 13)? Control system problems? Fault finding by the self-check mode (Page 13)? Sensor fault,.(page 13)]? How to replace the sensor (Page 14)? LED display fault.(page 16)? How to remove parts inside of electrical box (Page 16)

3 / 18 Cooling system faults. How to diagnose faults: It should take approximate 3 hours to reach the lowest setting temperature of 5 for an empty unit (assuming ambient temp of 32 degrees centigrade and continuous operation). If not, check the compressor, cooling fans, controller, and sensors. If all these are working normally, there is probably a cooling pipe fault. Check points 1/ Compressor: Warning this check requires the power to be on, take extra care and consult a qualified electrician Turn on the unit and check there is electricity current flowing to the compressor using a caliper type Amp meter, the current should be within 0.6 to 2 Amps. If the readings are not in this range, turn off and cut off the pipes (G and E see Fig.12) from the compressor, then turn the unit on again (in this case only run the compressor for a few minuets) and recheck the current and if there is pressure at the outlet pipe. If the current reading is still out of range specified above and no pressure from the compressor outlet, replace the whole compressor 2/ to check the cooling system pipe work Carefully check the cooling system after verifying the compressor is working normally. Then follow the procedure below 2.1>Check for leaks. Then cut off process pipe and check the refrigerant. If there is not enough refrigerant, this indicates a small leak isolate the leak and repair it (see below), recharge the system with the correct amount of refrigerant, (0.8-1Mpa of nitrogen) 2.2>. a. Cut off discharge pipe from compressor and charge with refrigerant to 0.8 1Mpa nitrogen via the process pipe. Then place your hand close to the broken end of discharge pipe, if you can feel a little airflow, this proves the capillary is normal, if not it means the capillary is jammed. b. Weld the broken discharge pipe if capillary works normal, then charge to 0.8 1Mpa nitrogen via the process pipe and check if there are any leaks from every soldered joint of the cooling system using soapy water and looking for tiny bubbles, Check the soldered joints around the compressor first (Fig.12), then check the soldered joints around the evaporator see (Fig.11). Remove the air duct board when you check the evaporator joints, see (Page 3). c. If there are no leaks. The faults are A leak in the condenser or anti-dew pipe Or a fault of one of the other components in the unit, These internal leaks cannot be repaired. 2.3>. If there are no leaks in the cooling system pipe work 3/ Refill the refrigerant: 1>. Using the vacuum pump form a vacuum in the system, via the joint of the low-pressure pipe, the high-pressure pipeline is on the process pipe of the drain filter. Apply the vacuum pump for approximately 20 minutes. Until the vacuum is lower than 100Pa. Then solder the drainpipe. Keep the vacuum running while soldering this joint 2>. Fill Cooling system with refrigerant via the process pipe. (The refrigerant is R134a. Regarding refrigerant quantity Please refer to the instruction at back label of wine cellar). Then solder the compressor process pipe after the system is charged with refrigerant. 4/ Running test: Replace all the components after the procedures above and turn the unit on. To verify the effectiveness of the repair, monitor the unit the compressor should automatically stop within + or - 2.5 deg centigrade of the set temperature within approx 3 hours (assuming an ambient temperature of 32 and the unit is empty) How to remove the air duct board. 1>. Remove the shelves; some models have Phillips head screws to hold other models have no screws (Fig.1)

4 / 18 Fig.1 2>. 2>. Remove the electric box. There are two. For old version, see below 1 To disassemble the old version a. Remove box fixing screws (1,2,3,4), See (Fig.2). (The right hand diagram is for reasons of clarity only). Fig.2 b. Pull out electric box to expose the control panel as per the direction of arrowhead, then unplug all the connectors from the control panel, and remove electric box (A). See (Fig.3) (Fig.4) Shows the new version of the control panel

5 / 18 Fig.3 Fig.4 New version control panel connections 1. To the fan of the refrigeration compartment (F3 White). 2. To the air cycling fan.(f2 Yellow) 3. To the fan of the freezing compartment.(f1 red) 4. To the sensor of the freezing compartment (X1 yellow) 5. To the sensor of the refrigeration compartment (X10 White) 6. To the sensor of the evaporator (X11 Red) 7. To the power supply (L,N) 8. To the grounding or earth 9. To the PTC heater (X9 White) 10. To the compressor (X3 White)

c. Remove screws (6,7,8,9,10,11), then remove the lower cover of middle air duct board: (Fig.5) 6 / 18 Fig.5 d. Remove screws (12,13,14,15,16,17), then remove the upper cover of the middle air duct board (G) to expose the air duct board. See (Fig 6) Fig.6 2 To disassemble the new version a. Remove the shelves then remove the fixing screws (2,3). (The right hand diagram shows the box for clarity only). See (Fig 7)

7 / 18 Fig.7 b. Remove the upper cover of middle air duct board (A), then unplug all connectors from the control panel: (Fig 8). The connections of the control board are as per (Fig.4). c. Remove the fixing screws (7,8,9,10,11,12), then pull out electric box (C) to expose the air duct board; (Fig.9) Fig.9

3>. Remove the fixing screws of air duct board (1,2,3,4,5,6), then pull out air duct board (A). See (Fig 10) 8 / 18 Fig.10 4>. For a View of the internal configuration after removal of the air duct board, see (Fig.11) Front side joints location. See (Fig.11) A. Capillary soldered joints B. evaporator soldered joints See (Fig.12) for a rear side view of the joints position. B. Dry filter process pipe soldered joint C. Dry filter soldered joint. D. Capillary soldered joint E. Process pipe soldered joint. F. Suction pipe soldered joint G. Discharge pipe soldered joint H. Condenser process pipe soldered joint I. Anti-Dew pipe soldered joint

9 / 18 Heating system faults How to diagnose faults: If the temperature of refrigeration compartment is (-2 ) lower than setting temperature for an empty unit (assuming ambient temp of over 0 degrees centigrade and continuous operation and normal temperature of the freezing compartment), check the heater fan and PTC heater. If both are working normally, there is probably a heating system fault. How to repair the fault: 1. How to check the heater fan. If the temperature of refrigeration compartment is lower than set temperature but heater fan does not function, after verifying no bad connections replace the fan unit (Fig.13) 2. How to check the PTC heater Check the resistance at both sides of PTC heater using a Multi meter; the reading should be approx 1.5 KΩ (assuming normal temperature), if open circuits Replace the PTC heater having once verified the connections to the PTC heater. See (Fig.11) 3. If no fault in the fan or PTC heater, replace the control panel, see (Page 16). High noise of wine cellar compressor noise 1. The working of motor and piston motion will cause noise when compressor working. So if noise is steady and not exceeds 42 db, it s normal. If noise is not steady or very high, it s compressor fault and it should be maintained or replaced. 2. If compressor s shock absorption rubber is hardening or damaged, or fixing screw of compressor is too tight or loose, it will cause noise. The settlement is to change new shock absorption rubber or adjust fixing screws. fan noise 1. Normal fan motor and airflow should not exceed 32 db. 2. If there is noise above 32BD or the noise levels fluctuate the fan shaft is either damaged or worn. 3. How to replace the fans 1>. Heater fan. a. Remove the shelves. See (Fig.1) b. Remove the electric box. See (Page 4) c. Remove the air duct board. See (Fig.10)

10 / 18 d. Remove screws (1,2,3,4), then replace the heater fan. See (Fig.13) Fig.13 2>. Air cycling fan and evaporator fan. 1. If the unit has an new style electrical box a. Remove the shelves and screws (1,2), then pull out the upper cover of the middle air duct board (A); See (Fig.14) b. Then remove the foam (B), (Caution: Do not damage the foam). See (Fig.14) Fig.14 c. Remove the fixing screw (3), then remove the sensor(c); See (Fig.15)

11/ 18 Fig.15 d. Remove the fixing screws (1,2,3,4), then remove the air cycling fan (A). See (Fig.15.1); Remove the fixing screws (5,6,7,8), then remove the condenser fan (B). See (Fig.15.1); and replace them separately. Fig.15.1 2. If the unit has an old style electrical box, a, Remove the lower cover of middle air duct board, See (Fig.5),then remove the foam(a), See (Fig.16) b, Remove screw(9), then remove the sensor(d); See (Fig.16) c, Remove screws(1,2,3,4 ), then remove air cycling fan(c); See (Fig.16) Remove screws(5,6,7,8 ), then remove evaporator fan(b); (Fig.16) Then replace them separately

12 / 18 Fig.16 Refrigerant jet noise If here is continuous noise like a water spray from the capillary, the end of the capillary is in the wrong position, or there are rough edges on the end of the capillary 1>. Heat the soldered joint of the capillary ( A of Fig.11), then remove the capillary from the evaporator and smooth the end with an eraser. (Caution: do not allow any particles into capillary unit) 2>. Replace the capillary into the evaporator, then solder it back into the correct position (not exceeding 15mm in the evaporator) and pack the joint with anti vibration compound 3>. Recharge with refrigerant. See (Page3) Capillary vibration noise Fault: high frequency impact noise in capillary Zone. Caused by either: 1>. The capillary being insert too deep into the evaporator, so when the refrigerant is Jetting, the end of vibrating capillary will hit the inside of the evaporator. 2>. Vibration from the capillary touching the inside of the cabinet or air duct board, then when refrigerant is jetting. How to repair this problem 1>. De-solder the capillary and re-solder in the correct position avoiding contact with the inside of the evaporator, (The depth should be within 15mm), then recharge the unit with refrigerant. See (page 3) 2>. If the capillary touches the inside of the cabinet or air duct board, you should Adjust position of capillary and pack it with anti-vibration compound. (Fig 11) Oil jammed noise Fault: intermittent and deep jet noise coming from inside of the capillary. Caused by: Compressor oil flowing into the cooling system pipe work probably due to the capillary slightly out of alignment during transportation, Clean the cooling system pipe, and recharge with refrigerant see (page 3) Evaporator freezing. This is normally due to A/ Poor seal between door and doorframe B/ The door not closed correctly for a long period of time, This allows moist air into the cabinet, which freezes in the evaporator, if the ice is allowed to get

too thick, it may damage the fan 13 / 18 1>. Ensure the door is sealed against the frame, If there is slight distortion of the seal, heat the effected area gently with a hair dryer gently see (Fig.17) with smooth strokes of the hair dryer, then when still warm pull the effected area back into its original position, this process may have to be repeated until the seal is completely back to its original condition, If this fails, replace the seal. Fig.17 2>. If the ice has damage the fan it will need to be replaced. See (Fig.15.1 & Fig.16) Unstable temperatures inside the cabinet. Unstable temperatures inside the cabinet is mostly due to a fault in the evaporator fan, you can check this by: When compressor works, the RUN indicator light should come on and the fan should spin, If fan does not spin check the fans electrical connections are faulty and repair them or if the fan is damaged replace the whole fan unit. See (Fig.15.1 & Fig.16) Control system fault Difference between old and new version control panel. JG32C wine cellar has two versions of control panel. See (Fig.4) The difference between the two is: New version has the evaporator sensor socket (X11) and the refrigeration compartment sensor socket (X10) is in a different position as is the freezing compartment sensor socket (X1). Ensure the replacement control panel is correct before replacing it if it faulty, please refer to section < To disassemble old style electrical box>, See (Page 4) Fault finding by self-check mode. This series wine cellar has a computerized controller with built in self-check function. Start the self-check mode as follows: 1>. Press and hold Set lower and Set upper button with power on. 2 beeps will sound, and then the controller will start the self-check function 2>. If everything is operating correctly, a. No response when pressing buttons. b. LED only display 20 if ambient temperature is over 20, and display actual temperature if ambient temperature is lower than 20. c. The compressor works and the RUN indicator light are on all the time. d. If the cooler has condenser and evaporator fans they should work at full speed; Heater and air cycling fans should work for 30 seconds alternately. e. The switch controls the light functions normally. 3>. If the control panel and the various components of the unit do not respond as above check the faulty part and relevant connection. If this does not cure the fault replace the control board see (Page 3) 4>. To return the control panel to its normal working mode UN plug the unit and plug it in again

14 / 18 5>. Only the new version control panel has a self-check mode. Sensor fault 1>. The LED temperature display should the actual ambient temperature shortly after the unit is plugged in, if not check if the connections are good in the electrical box see (Page 4), check if the sensor plug is connected properly, if the connections are good and the fault persists replace the sensor. 2>. If the LED displays E1 indicates a freezing compartment sensor open circuit fault and the sensor should be replaced see (Page 14) 3>. If the LED displays E2 indicates a freezing compartment sensor short circuit fault and the sensor should be replaced see (Page 14). 4>. If the LED displays E3 indicates an evaporator sensor open circuit fault and the sensor should be replaced see (Page 14). 5>. If the LED displays E4 indicates an evaporator sensor short circuit fault and the sensor should be replaced see (Page 14). 6>. If the LED displays E7 indicates a refrigeration compartment sensor open circuit fault and the sensor should be replaced see (Page 15). 7>. If the LED displays E8 indicates a refrigeration compartment sensor short circuit fault and the sensor should be replaced see (Page 15). 8>. For some older models with old version control panels, If the LED displays 37, 99F or infinity, replaces the sensor. See (Page 14) How to replace sensors 1>. Evaporator sensor The evaporator sensor is plugged into the fin of evaporator. Remove the air duct board to access the sensor plug (A) and unplug in the direction of the arrowhead. See (Fig.18), then unplug the other end of sensor from the X11 socket of the control panel, and replace it. See (Fig.4). A Fig.18 2 >.Freezing compartment sensor. The freezing compartment sensor is located on the evaporator fan, See (A of Fig.19). If it faulty, please refer to section < How to remove the Air cycling fan and evaporator fan>, See (Page 10)

15 / 18 Fig.19 3 >.Refrigeration compartment sensor. Refrigeration compartment sensor is located on (B) of (Fig.19). It has two different installations with 2 different replacements. See (Fig.20 & Fig.20.1) For new replacement: Remove the 2 fixing screws (1), then remove sensor cover (2), pull out the sensor (4) from the sensor cover, and unplug the housing (3), then replace the sensor. See (Fig.20) For old replacement: Remove the air duct board see (Page 3), then remove the fixing screw (1), then unplug the other end of sensor from socket (X1) from the control panel, and replace the sensor. See (Fig.20.1) Fig.20 Fig.20.1 4>. There is a quick replacement solution for refrigeration compartment sensor, See (Fig.21) a. Remove the sensor fixing screw and pull out the sensor, cut off the wire at the end of the sensor (A); b. Split the ends of the wires about 50mm, and strips the ends about 12mm (B): c. Prepare 2 heat shrink sleeves (Spec: φ2.5mm 25mm) and one new sensor (Spec: as per shown in diagram), See (C), (D). d. Take the new senor and split wire end through heat shrink sleeves, then connect the wire with new sensor, twist the wires together, slip the heat shrink sleeves over this 2 joints and secure the connection by heating the sleeves with a lighter. See (E) of (Fig.21)

16/18 Fig.21 LED display error Replace the electrical display board fault; see (Fig.22& Fig.23) How to disassemble the electrical box. There are two versions of electrical box (old and new). 1>. To disassemble old structure electrical box, See (Page 4) a. Remove the shelves and fixing screws (1,2,3,4) from the electrical box, then remove the box to expose the whole control board; See (Fig.2 & Fig.3) b. Unplug all the connecters, then press the head of each of the four plastic screws (5) one by one, then remove the control board (B) and replace the control board see (Fig.22) c. Remove the two transformer fixing screws and Replace the transformer (C); see (fig 22) d. To replacing the display board. Pull the four 4 display cover fasteners on display board cover (E) as per arrowhead direction, and then remove the display board (D) and its two connectors from both sides. Replace the display board. See (Fig.22)

17 / 18 Fig.22 2>. To disassemble new structure electrical box, See (Page 6) a. Remove all the shelves and the upper cover of the air duct board to expose the whole control panel, See (Fig.7) b. Unplug all the connecters, then press the head of each of the four plastic screws (6) one by one, then remove the control board (C) and replace the control board see (Fig.23) c. Remove the two transformer fixing screws and replace the transformer (D); see (fig 23) d. To replacing the display board. Pull the four 4 fasteners of display board cover (F) as per arrowhead direction, and then remove the display board (E) and its two connectors from both sides. Replace the display board. See (Fig.23)

Fig.23 18 / 18