SERVICE VERSUS REMOVAL OF OBSOLETE COMMERCIAL KITCHEN PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Similar documents
FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

UNIFIED FACILITIES GUIDE SPECIFICATIONS

D. Reference Standards (Utilize latest editions available):

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

Design & Construction Standards, Revised January

June 2018 Safety Meeting Fire Extinguishers Part I

The Need For Fire Extinguishers & Rack Hose Regardless of Code Requirements

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

NFPA 96, 2017 REVIEW SUMMARY

Fire Suppression Installation (R-102) for AVI Hoods & XLT Ovens

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

COMMERCIAL KITCHEN FIRE SAFETY

XRRS Specification Fire Ready Hood

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

Sheetz Inc. Fire Protection Service Guidelines

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

Capital Projects Group Fire Extinguishers Specification

SECTION COMMERCIAL-KITCHEN HOODS

JOINT CODE INTERPRETATION

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

FM-200 In-Cabinet Series

CORE Protection Fire System Specification

June 20, 2011 PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS

ANSUL TO-ANSUL. For more information... Check your local Yellow Pages for your authorized Ansul Restaurant Systems Distributor.

SPECIFICATION: ARGONITE Engineered Fire Suppression System

NFPA Talking Points on NFPA 1 Fire Code update to the 2015 Edition:

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

Narrative Reports As Regulated by 780 CMR, Section 903.0

OWNER'S OPERATION AND MAINTENANCE MANUAL

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

COUNTY OF ROCKLAND Department of General Services Purchasing Division

Emergency Evacuation Plan

SUPPRESSION SALES I INSTALLATION I SERVICE

Fire-Rated Glazing Changes in 2012 International Building Code (IBC)

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

Are Your Kitchen Hood Filters Compliant?

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

DSPA-5 Manual. Product Information, Usage, Preperation and Deployment guidelines for users of the DSPA -5

KITCHENShield WCK Kitchen Fire Suppression System. Advanced fire protection systems

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

KIDDE WHDR WET CHEMICAL FIRE SUPPRESSION AND INTELLIGENT CONTROL SYSTEM FOR COOKING OPERATIONS WITH ARIES-NET MULTI-LOOP INTELLIGENT CONTROL UNIT

ASHRAE JOURNAL ON REHEAT

Types of Detection. Fusible Link Detection - Most Common

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Hospitals and Major Medical Centers

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

SECTION FM-200 FIRE SUPPRESSION SYSTEM

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

NAFED Fire Extinguisher Training Seminar Pre-Engineered Systems Seminar

Design Criteria. Installation

36 months or more 12 months

Chapter One Commercial Kitchen Fires

Linear Heat Detection Engineering Specifications

Water Purveyor s Guide to 2006 Fire Sprinklers in Single Family Dwellings

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

A Guide for Meeting NFPA 10 Subsection

In just two minutes, a fire can become life-threatening. In five minutes, a residence can be engulfed in flames.

ICC CODE CORNER 2015 International Fire Code

FIRE SAFETY PRACTICES AND PROCEDURES

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

The Cannabis Industry: Fire Department Requirements

Fire Suppression Introduction Contact Information

Model Policy On Portable Fire Extinguishers (Ontario Version)

Get it Right the First Time Avoid These Commonly Cited Errors

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

EVALUATION SUBJECT: FIRE SUPPRESSION RANGE HOOD DIVISION: MECHANICAL SECTION: COMMERCIAL-KITCHEN HOODS.

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

MERAMEC VALLEY R-III SCHOOL DISTRICT 126 North Payne Street Pacific, MO

PART 1 GENERAL 1.01 SUMMARY

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

Fixed fire protection solutions

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Figure 1. Figure 2. See notes 1 and 2 below.

NEW ENERGY IN THE BATTERY INFRASTRUCTURE

Kitchen Suppression System Manuals

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Emergency Response Plan

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Transcription:

SERVICE VERSUS REMOVAL OF OBSOLETE COMMERCIAL KITCHEN PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS The members of the Fire Equipment Manufacturers Association (FEMA) are in the business of providing the very best design & system hardware for fire control and extinguishment. Commercial Kitchen Wet Chemical Pre-Engineered Fire Suppression Systems are a critical component in a balanced fire protection plan. These systems are a proven tool when used in the beginning stages of a fire. They significantly minimize the risk of death, injury, and property loss. Manufacturers invest heavily in research and development to find an optimum combination of design characteristics, hardware, and extinguishing agent. Operator safety, fire control, extinguishment performance, and system design are the primary concerns as Preengineered Systems are brought to the market. The members of the National Association of Fire Equipment Distributors (NAFED), other independent qualified fire equipment distributors, and fire protection professionals know that an essential part of good fire protection is maintaining equipment so that it will be operational any time an emergency occurs. The protection of life and property should never be compromised. Therefore, the design, installation, service, and maintenance of Commercial Kitchen Wet Chemical Pre-engineered Fire Suppression Systems must be done according to published recognized standards and the manufacturer s instructions. Questions sometimes arise about maintaining older kitchen pre-engineered systems manufactured by companies no longer in business (such as System Master, Reliable, Safety First, and others), systems that have been declared obsolete by existing manufacturers, or systems for which replacement parts or recharge agent are no longer available. History has shown us that the use of components not specified in the manufacturers' installation manual or recognized by the listing agency as part of a pre-engineered systems listing can cause dangerous and even life threatening results. Pressure relief devices, safety disks, gauges, o-rings, and valve stems are made to exact tolerances, as are control heads, detection devices, manual remotes, and emergency shut-offs. Discharge nozzles are designed and matched to chemical characteristics to give measured flow rates and discharge pressures. System agent cylinders must be compatible. Agent quality and chemical characteristics are unique to each system manufacturer. Non-listed agents may produce different flow characteristics and have been shown to fail to discharge effectively. Agents must be tested with each individual system design and hardware by a nationally recognized testing laboratory to assure that required discharge times, discharge flow rates, nozzle discharge patterns and fire extinguishing performance are acceptable. End-users must FIRE EQUIPMENT MANUFACTURERS' ASSOCIATION Executive Director: THOMAS ASSOCIATES, INC. 1300 Sumner Avenue, Cleveland, Ohio 44115 2851 Telephone: 216 241 7333 Fax: 216 241 0105 E Mail: fema@femalifesafety.org www.femalifesafety.org www.rackhosetraining.com www.firesystemstraining.org

be able to count on the listed performance of a pre-engineered system for their safety. FEMA offers the following information to help clarify when a pre-engineered system should no longer remain in service due to its lack of a recognized listing. Codes & Standards There are legal requirements that call for the installation and maintenance of listed Commercial Kitchen Pre-engineered Fire Suppression Systems. Most states have adopted NFPA 96, NFPA 17A, and NFPA 17 through their Building, Mechanical and Fire Prevention Codes. If a pre-engineered system is no longer considered listed, it cannot be used to satisfy the requirements of Federal or State Codes. FEMA members design Commercial Kitchen Pre-engineered Fire Suppression Systems according to Underwriters Laboratories Inc. (UL). Commercial Kitchen Pre-engineered Fire Suppression Systems are tested for performance per ANSI/UL 300. The combination of design characteristics, hardware, and agent are incorporated as part of a pre-engineered systems listing. The 2002 edition of NFPA 17A Standard for Wet Chemical Extinguishing Systems states: (4.1) Only system components referenced or permitted in the manufacturer s listed installation and maintenance manual or alternate components that are listed for use with the specific extinguishing system shall be used. (4.6.1) The type of wet chemical used in the system shall be listed for the particular system and recommended by the manufacturer of the wet chemical system. Wet chemical solutions of different formulations or different manufacturers shall not be mixed. (5.1.1) Wet chemical fire extinguishing systems shall comply with standard UL 300. (7.3.1) A trained person who has undergone the instructions necessary to perform the maintenance and recharge service reliably and has the applicable manufacturer s listed installation and maintenance manual and service bulletins shall service the wet chemical fire extinguishing system 6 months apart as outlined in 7.3.2. (7.4.2) Systems shall be recharged in accordance with the manufacturers' listed installation and maintenance manual. Additionally, the 2001 Edition of NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations states: (10.1.1) Fire-extinguishing equipment for the protection of grease removal devices, hood exhaust plenums, and exhaust duct systems shall be provided. (10.2.1) Fire-extinguishing equipment shall include both automatic fire-extinguishing systems as primary protection and portable fire extinguishers as secondary backup. (10.2.3*) Automatic fire-extinguishing systems shall comply with standard UL 300, Standard for Fire Testing of Fire Extinguishing Systems for Protection of Restaurant Cooking Areas, or other equivalent standards and shall be installed in accordance with their listing. (12.1.2.2*) Cooking appliances requiring protection shall not be moved, modified, or rearranged without prior reevaluation of the fire-extinguishing system by the system installer or servicing agent, unless otherwise allowed by the design of the fireextinguishing system. Commercial Kitchen Pre-engineered Fire Suppression Systems must be listed. NFPA defines listed as equipment, materials, or services included in a list published by an organization that is acceptable to the authority having jurisdiction and concerned with evaluation of

products or services, that maintains periodic inspection of production of listed equipment or materials or periodic evaluation of services, and whose listing states that either the equipment, material, or service meets identified standards or has been tested and found suitable for a specified purpose. In recent correspondence, which is attached, Underwriters Laboratories clarified that an extinguishing system would not be considered listed unless that system was serviced and maintained in accordance with NFPA 96, NFPA 17A, and NFPA 17, the instructions on the nameplate, and the manufacturer s manual referenced on the nameplate. When the appropriate service part(s) or agent for recharging are no longer available for a specific model UL Listed extinguishing system unit, the Listing for that system unit cannot be maintained in accordance with the manufacturer s manual, NFPA Standards, and therefore, would not be considered UL Listed. Liability Liability for servicing Commercial Kitchen Pre-engineered Fire Suppression Systems, particularly those manufactured by companies that have long been out of business, rests solely with the system service company and its components supplier. No one else is around to answer questions either in or out of court. Only the assets and insurance policies of the system service company and perhaps the end-user are available to back up any problems should an incident occur. Given the age and antiquated design of some pre-engineered systems, it is logical that problems are more likely to arise with older, outdated hardware than with newer equipment that meets current design standards, as well as current Building, Mechanical and Fire Codes. Warranties, even if the manufacturer of the system hardware is still in business, have long since expired. An older system could have been manufactured by a quality conscious manufacturer that is still in business, but that same manufacturer recommends the system be removed from service and is no longer making replacement parts available. Service companies that use manufacturer recognized components and agents as specified in the system installation manual and the listing agencies published listed components directory, protect their license, help avoid claims against their products liability insurance policy, and protect their good reputation and public trust. Antiquated Commercial Kitchen Fire Suppression Systems In today s tight labor market with costs for energy, insurance, vehicles, and real estate soaring, it is a mistake to assume that labor-intensive service work on antiquated Commercial Kitchen Pre-engineered Fire Suppression Systems is always profitable. Without using some form of Activity Based Costing, it is difficult to determine exact costs of service. A 25-yearold pre-engineered system that no longer meets the current code requirements cannot be maintained in accordance with NFPA Standards or no longer has a manufacturer supporting it should be considered for replacement. Additionally, dry chemical systems are no longer approved for cooking hazards. Any labor or service work performed on these type systems is wasted money for both the service company and the end user. Many end-users have a policy regarding replacement costs. If the cost of repairs, updates, or service work exceed a certain percentage (often 50%) of the cost to replace the equipment, they would rather replace it and take advantage of current design technology, as well as a new warranty. However, if service is performed no one can be assured of the system s performance should it be called upon in a fire situation. At the end of the day, the end-user still has a 25-year-old pre-engineered kitchen system that doesn t meet the needs of the

current cooking hazard, local, and state Building, Mechanical and Fire Codes or its UL Listing. If a service company uses part(s) or agent not approved: What happens if the system fails to operate? What happens if the system fails to discharge properly? What happens if someone is injured? Conclusions There are Commercial Kitchen Pre-engineered Fire Suppression Systems in the marketplace that should be removed from service because they are obsolete, are no longer supported by a manufacturer, do not meet current code requirements, have lost their UL Listing, or are just too costly to update and maintain. This should be done first and most importantly to insure life safety. FEMA members are in the business of protecting life and property. Building, Mechanical and Fire Codes require APPROVED and LISTED pre-engineered systems for code compliance. Federal requirements require contents in a system container to match the nameplate. Underwriters Laboratories Inc. requires servicing to be performed using parts and recharge agents that will maintain the pre-engineered systems listing. Improper parts or agent will cause the system to loose its status as UL Listed. By removing outdated or obsolete preengineered systems, customers get new equipment that meets current standards. Most importantly, safety to life and property is maximized. Both the customer and the service company will benefit from a fresh factory warranty and a Commercial Kitchen Pre- Engineered Fire Suppression System designed to meet their current cooking hazard and the liability issue discussed earlier is avoided. Prepared by the members of FEMA s Systems Division Visit our website on Balanced Fire Protection at www.femalifesafety.org