Fire Suppression Systems

Similar documents
MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

FIGHTING FIRE as easy as blowing out a match

Fire and Security Products and Services

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

Element C3.4 Fire Fighting Equipment

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

WATER MIST CONVENTION AND EXHIBITION

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Sprinklers in Europe known problems and misconceptions. Alan Brinson

New Approaches to Design for Fire Safety - Residential sprinklers, open plan flat layouts and water mist

K Series - Fire Suppression Systems for the Catering Industry

What is HI-FOG? The natural enemy of fire

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

The Science Behind Water Mist Protection of Typical Building Hazards

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Standards and third party certification

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Fire protection for buildings

Certificate No: EWS534

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

Personal Protection Systems (PPS)

An Overview of Extinguishing Systems for Computer Equipment

Third Party Certification:

The Route to Third Party Certification

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

Installation and Maintenance Requirements

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Nessie High Pressure Water Mist Components for Fire Fighting

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

PREVENT SYSTEMS WHEN SAFETY IS TAKEN SERIOUSLY

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

Aspirating Smoke Detection (ASD) Systems Fire Detection

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Fixed fire protection solutions

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

Crown Premises Fire Inspection Group

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

Water Mist v Sprinklers

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

Retail solutions by Tenos. Value engineered fire safety solutions for landmark retail developments.

ISLE OF WIGHT FIRE & RESCUE SERVICE

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

Fire protection solutions for ships and offshore facilities

Occupational Health & Safety Practitioner. Reading BUILDING FIRE SAFETY

Fire fighting with fast deployment units. CRISTANINI Spa Via Porton 5, Rivoli Veronese, ITALY

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

Advanced Fire Rated Ductwork Solutions

Building Services Brochure

Watermist Systems Compliance with Current Fire Safety Guidance

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

FIRE SAFETY IN THE HOME

Water Mist Fire Suppression

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

FOREFRONT AT THE OF PROTECTION

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

FIRE SAFETY IN THE HOME

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

Ceasefire Watermist Hydrant Systems

This document is a preview generated by EVS

What extinguishes fires without pressure peaks?

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Reflex fire detection and extinguishing system filled with ABC dry powder. Installation, operation and maintenance instructions

FIRE STOP 200/30. High technology system for first attack of fire with high pressure nebulized water (Water mist) FD 907. Ed.

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Reflex fire detection and extinguishing system charged with Novec 1230 extinguishing agent. Installation, operation and maintenance instructions

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Local area fire protection using automatic suppression

High-Pressure Water Mist systems for the protection of shopping centres in historical city centres

Checklist For Building Inspection & Fire Safety

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

MORE THAN JUST FIRE PROTECTION

FIREMASTER CONCERTINA TM

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

asphalt applications European Asphalt Standards and their application in the UK mpa asphalt Asphalt Information Service Mineral Products Association

HIGH PRESSURE WATER MIST SYSTEM Application: High Rise Building Bindreiter Michael London,

Oxeo extinguishing systems

Transcription:

Fire Suppression Systems www.watermist.com Public Buildings Custodial Food Industry Transportation Power Generation

The Hydramist product range was created to address fast, safe and efficient water based fire suppression systems that present no risks to the environment or people. fire suppression systems Hydramist Introduction Hydramist is a high pressure watermist fire fighting system manufactured by Watermist Limited in the UK that is designed to suppress and extinguish fires in a wide range of applications. With many years combined experience in fire suppression and equipment manufacture the Hydramist product has quickly become a leading fire suppression system in the United Kingdom and Europe. At Hydramist Fire testing is an integral part of our product development. We have tested a wide variety of applications using recognised fire testing institutions such as Building Research Establishment (BRE). Hydramist actively supports and is working with regulatory authorities to establish relevant standards and codes of practice. The company has a quality based approach to all of its activities and is UKAS accredited to ISO9001:2008, Hydramist products are CE marked in accordance with European regulations. Hydramist products have been installed in commercial kitchens, factories, offices, banks, hotels, public buildings including prisons, courts and libraries. Get in touch with us today, contact: Hydramist Fison Way, Thetford, Norfolk IP24 1HT United Kingdom T: +44 (0) 800 731 9288 E: info@watermist.com W: www.watermist.com 02 T: +44 (0) 800 731 9288 Introduction

product application Product applications, system design and application advice The Hydramist product range has many applications, including the following: Commercial Kitchens, Industrial Fryers, Ovens and Food Processing Factories Prisons, Hotels, Guest Houses and Accommodation Blocks Archive Stores and Libraries Power Generation (Diesel Generators, Turbines, Battery Rooms) Specialists available to survey, design and specify fire suppression systems Hydramist design manual available to guide architects, consultants and equipment suppliers Telephone help line to provide advice and guidance on selection of nozzles and equipment Website interactive notice board to provide feedback and comments Engine Test Cells Data Centres, Communications and Server Rooms Plant and Electrical Switch Rooms Offices and Public Buildings Warehouses and General Storage Facilities W: www.watermist.com Case Studies 03

fire suppression products (please note images are not to scale) MHRU Modular Hose Reels Fixed Hose Reel Cabinet Offering a more effective alternative to conventional hose reels, the Hydramist Modular Hose Reels flow less than a quarter of the water provided by a conventional hose reel and because the water is atomised it can protect an area up to 100 times larger. MHRU s are used extensively within the United Kingdom prison service for fighting fires in cells and accommodation areas and the food industry for effectively dealing with fires in waste bins and fryers. Installed as replacement or in addition to a conventional hose reel Can be installed anywhere in any building requiring only a 15mm water supply and single phase power supply Hose reach 35m 50m Easy to use trigger assembly and controls Reduced water use and residual water damage Dramatically reduces smoke spread from the fire Proven in extensive testing with the UK Building Research Establishment and the Ministry of Justice to provide a life sustainable environment whilst in use Patent GB2458698 Used in conjunction with the Hydramist range of fixed pump sets, the Fixed Hose Reel Cabinet gives a flexible method of providing high pressure watermist fire fighting into any building or area. Used extensively within the United Kingdom prison service for fighting fires in cells and accommodation areas the Hydramist Fixed Hose Reel Cabinet can be installed anywhere that a conventional hose reel is used. Fire fighting system that can be quickly deployed around any building Installed as replacement or addition to a conventional hose reel Can be installed anywhere in any building in conjunction with a Hydramist fixed pump set Hose reach 35m 50m Easy to use trigger assembly and controls Proven in extensive testing with the UK Building Research Establishment and the Ministry of Justice to provide a life sustainable environment whilst in use Reduced water use and residual water damage Dramatically reduces smoke spread from the fire 04 T: +44 (0) 800 731 9288 Product Range

fire suppression products (please note images are not to scale) 120PU Pump Sets CPU Pump Set Range With an output of 120 litres per minute at a constant pressure of 100bar the 120PU pump sets can be coupled together to give increased outputs of 240litres/min, 360litres/min (or any other multiple of 120litres/ min). Used primarily for larger risks, the Hydramist 120PU has been used to provide protection to IT Data Centres, Power Generation plants, Archive and Library storage areas, Food factory production lines and many other risks both large and small. Food factory production lines Power generation equipment Server and Communications rooms Local application risks with multiple areas Each 120PU delivered complete and tested Reduced water use and residual water damage Low power consumption and start up configuration Delivered complete with integral 1000 litre water tank Available with outputs of 30, 36, 45 & 54 litres per minute at a constant pressure of 100bar the CPU range was designed to be compact to enable easy installation into confined spaces within buildings. Used extensively within the UK prison service and food industry the CPU is most suited to multiple areas requiring protection. Food factory production lines Power generation equipment Server and Communications rooms Prisons (when used in conjunction with Fixed Hose Reel Cabinets or fixed in cell nozzles) Local application risks with multiple areas Each CPU delivered complete and tested Reduced water use and residual water damage Low power consumption Delivered complete with integral 250 litre water tank W: www.watermist.com Product Range 05

fire suppression products (please note images are not to scale) Mobile 8 Nozzles Providing fast reactive fire fighting, the Hydramist Mobile 8 unit is used extensively, but not exclusively, within the United Kingdom prison service for fighting fires in cells and accommodation areas and in the food industry for effectively dealing with fires in waste bins and fryers. First reaction mobile watermist fire fighting system that can be quickly deployed around any building Easy to use lance and controls Guaranteed 5 minutes of fire suppression Reduced water use and residual water damage Dramatically reduces smoke spread from the fire Proven in extensive testing with the UK Building Research Establishment and the Ministry of Justice to provide a life sustainable environment whilst in use Hydramist fire suppression nozzles are designed and tested to provide fast and effective fire suppression to a wide range of applications. Heat sensitive frangible bulbs from 57-141 C Open nozzles for deluge applications Varied flow rates to match applications Food safe stainless steel nozzle protection caps Individually numbered to provide traceability Precision manufactured from stainless steel to give long service life 06 T: +44 (0) 800 731 9288 Product Range

fire suppression products (please note images are not to scale) Kitchen fire suppression in10 seconds 15AMPU Designed primarily for fire suppression on deep fat fryers in commercial kitchens, the Hydramist 15AMPU has been tested and approved by the LPCB LPS1223 standard. The Hydramist 15AMPU offers fast and effective suppression and extinguishing, is safe for people and the environment and dramatically reduces the spread of smoke from a fire. Fast acting and effective fire suppression system with both automatic and manual operation Tested and approved to LPCB LPS1223 Continuous operation until manually stopped Reduced water use and residual water damage Dramatically reduces smoke spread from the fire Easy to install Cost effective Kitchen area returned to normal within minutes of a fire Stainless Steel case to meet food standards finish and match styling of existing kitchen equipment W: www.watermist.com Product Range 07

UK Supreme Court Law library Located in Westminster, London, the Westminster Guildhall is of historic interest dating back to 1889. The building was closed in March 2007 for refurbishment and conversion to the United Kingdom Supreme Court. As part of the these works The Ministry of Justice required a 21st century fire protection system to protect the nationally important central law library within the main building. A key requirement of the design was that the fire protection system should be largely unseen, blending in with the antique style library furniture and bookshelves. Live fire tests with the Hydramist system demonstrated that stored materials suffered very minimal water damage and it was noted that the Hydramist system provided a greater level of fire suppression than other competing suppression systems. The requirement for minimal aesthetic impact of the system was easily satisfied by incorporating the nozzles within an existing suspended light rail. The Hydramist system supply piping was hidden above the bookcases and behind architectural wall mountings. The overall project Architects, Feilden & Mawson, were impressed by the experience and data that Hydramist Limited were able to provide to ensure that this project was carried out smoothly and to the entire satisfaction of all parties. Following competitive evaluation and extensive testing, Hydramist was selected for this project. 08 T: +44 (0) 800 731 9288 Case Studies

HM Prison Service The HM Prison Service commissioned a set of tests to determine the effectiveness of the traditional hose reels which, to date, had been installed in prisons across England and Wales throughout the 20th century. During these tests it was observed that the conventional hose reels did not effectively fight the fire and that smoke from the fire presented a greater risk to both the cell occupants and rescuers than the fire itself. The use of conventional hose reels also created extensive water damage and extended turnaround time of the affected cell in some cases the cell below as well. Knowing that Hydramist systems offer a far more efficient way of using water to fight fires, the HM Prison Service asked us to participate in a series of evaluation trials to determine the effectiveness of Hydramist systems, these were held at the world renowned Buildings Research Establishment (BRE). The BRE test criteria established were: maintain a tenable atmosphere for a period of 20 minutes when fire tested in accordance with the specifications discharge a relatively small amount of water deliver a spray of water mist with sufficient momentum to discharge droplets to the back wall of a cell The inundation was to last for 5 minutes after pre-burn and operation of internal cell fire detection systems, then a simulated rescue of an inmate involving opening the door for a set period of one minute would occur, followed by re-closing the door and waiting 10 minutes during which time the fire was not to resume. Hydramist tested the products as follows: Mobile 8 and Hosereel mounted hand held lances Fixed in cell nozzle with glass frangible bulb operation using a locally mounted pump unit In all tests Hydramist : Successfully extinguished the fire at the first attempt Dramatically reduced cell temperature, toxic gases and smoke to tenable levels Ensured sufficient oxygen was available to sustain life throughout the cell Note: During the rescue and ten minute waiting period after inundation that the fire did not resume; temperatures and toxic gases in the cell continued to fall, remaining well below levels that could be harmful to life. Since successfully passing these tests Hydramist systems have become the equipment of choice for The HM prison Service and are installed in over 150 prisons. W: www.watermist.com Case Studies 09

Network Rail Archive Store The very latest Hydramist technology for fire fighting has been used to ensure historic and valuable documents held in the network rail central archive store are protected by the most effective and efficient means. The bespoke warehouse archive facility contains an irreplaceable collection of rail-related documents dating back well over a hundred years-using The Hydramist system network rail knew that they would be protected by a 21st century fire protection and detection system. A requirement of the design was that the fire protection system should protect each individual storage area separately and be able to detect smoke before it was visible to the human eye. The Hydramist high pressure system was linked to VESdA (Very Early Smoke detection Aspirator) detection in the archive areas and conventional point type detection in the escape routes, corridors and stairs. It was observed that fires started in various positions within a scaled section of a typical archive store were quickly controlled by the Hydramist system preventing the fire from spreading and containing the smoke to the affected area only. Additionally it was observed that the precious archive documents stored adjacent to the fire source were safe throughout the tests as there was zero water penetration to the document containers. Crucially, the tests showed that this was the right solution for the archive being both effective at fighting fire and safe for the document storage application. A series of fire tests were designed and carried out by Hydramist Limited in accordance with the guide-lines of NFPA750 and the specific requirement of Network Rail under the supervision of their designated fire risk consultant. 10 T: +44 (0) 800 731 9288 Case Studies

Commercial Kitchen Systems Until now restaurant fryer fire protection systems have traditionally used dry powder or wet chemical fire suppression systems as a fire suppression medium. However these traditional systems can leave a large amount of potentially hazardous residues from the fire suppression agent on the catering equipment which must be cleaned up before cooking can re-commence. This leaves a restaurant without a kitchen during this period. Using atomised normal drinking water the Hydramist 15AMPU high pressure Watermist fire extinguishing systems act quickly to extinguish the fire and prevent re-ignition by cooling the oil and hot metal surfaces. The Hydramist systems very fine droplets of water turn to steam upon contact with the flames. The steam created then smothers the fire by displacing oxygen at the flame front to extinguish the fire. After extinguishment the mist evaporates latent heat away to prevent re-ignition. As the droplets are very fine no water can come into contact with the oil until the oil temperature is below 100c removing any risk of splashing. To verify fire performance, safety, and system durability the Hydramist 15AMPU system has successfully completed LPCB LPS1223 accreditation carried out and witnessed by the Building Research Establishment (BRE). Hydramist is the first high pressure Watermist product in the world to be included in the highly regarded LPCB Red Book for LPS1223 approved Kitchen Suppression Systems. Hydramist 15AMPU Systems have been installed for many well-known and prestigious clients including: Greggs the Bakers Rocco Forte hotels Sheffield University ITV KP Foods Brighton and Hove FC Norwich Open Academy Browns hotel of Mayfair Sanderson Hotel The Hydramist 15AMPU Kitchen Suppression System offers a cost effective fast reacting solution to this fire risk. Using a wall mounted Hydramist pump also eliminates storage issues for the fire suppression equipment. To see the 15AMPU in action visit www.watermist.com After activation next to no clean-up is necessary as the extinguishing agent is clean water allowing the kitchen to be back in operation extremely quickly. W: www.watermist.com Case Studies 11

Hydramist Fison Way, Thetford, Norfolk IP24 1HJ United Kingdom T: +44 (0) 800 731 9288 E: info@watermist.com W: www.watermist.com Hydramist is a trading name of Watermist Ltd a company registered in England Registration number 5672571