Microbiological Safety Cabinets ENVAIR eco safe Classic Class II Microbiological Safety Cabinet Standard EN 12469 Width (m) 0.9 / 1.2 1.5 / 1.8
Clean technology for a clean environment ENVAIR eco safe Classic the clean generation ENVAIR eco safe Classic Microbiological Safety Cabinets belong to the latest generation of laminar airflow systems, in which the choice of materials of construction of the highest quality guarantees conformity to the strictest safety standards. ENVAIR eco safe Classic vertical laminar flow cabinets are Class II Microbiological Safety Cabinets - designed and built to performance requirements of the EN-12469: 2000 European Standard, with 70% of the air re-circulated via the main Class H14 HEPA filter within the cabinet, whilst the remaining 30% is discharged through an exhaust Class H14 HEPA filter. Safety Cabinets with automatic regulation and microprocessor based monitoring systems. These cabinets are suitable for handling micro-organisms and pathogens as defined by the appropriate European and other International Standards, current health and safety guidelines and legislation aimed at safeguarding health and safety of operators at work. ENVAIR eco safe Classic Microbiological Safety Cabinets series are supplied with centrifugal fan to provide complete operator, product and environmental protection. Multifunctional Keyboard Manual opening front sash Stainless steel side walls with 2 service fixture (23 mm Ø) incl. 2 electrical sockets Full stainless steel chamber Multi-piece stainless steel work surface
Technology of today for the world of tomorrow Enhanced comfort and convenience 10 backward-slanted safety grade glass provides protection from explosion and UV with more comfortable viewing than vertical sashes. Counterbalanced sliding sash can be raised to a maximum height for easy introduction of large items The position of the light tubes ensure excellent illumination over the whole working zone and reduces operator fatigue. The radiused edge prevents the potentially dangerous practice of placing materials in this area Silent working conditions save your brain, you can concentrate on work and even hear yourself thinking. Easy to clean The cabinet work zone has no welded joints to collect contaminants or rust. Details of cabinet developed further to ensure easier cleaning with normal cleaning solvents Airflow laminator protects the filter surface during wipe cleaning. Optional multiple piece stainless steel work surface is easier to remove and put into autoclave / washer. Bottom sink is made of stainless steel type 304 with round corners and draining valves Self-induced Blower German made ebm-papst motors selected for energy efficiency, compact design, and flat profile. Sychronously communicates with microprocessor, there is no need for manual speed control Automatically compensates for normal power line variation, air disruption and filter loading. Motor consumes less energy, reduces heat output and operates more quietly. Filter Life Indication Filters has estimated service life, which is uncertain subject to different local air quality, research subjects and operation frequency. There is potential pollution harzard if operator is unconscious to filter expiration Patented filter life indicator is designed to measure filter life according to actual condition of membrane. You can rely on filter life indicator to make a confident plan for future filter replacement. Airflow Vertical laminar flow sensor
Our technology protects human and environment Airflow velocity monitoring Temperature-compensated airflow sensors monitor the airflow constantly to ensure safe operating conditions are maintained. Two independent sensors (downflow/exhaust airflow) mean double security. Downflow sensor provides instant and precise feedback to the blower so that its speed remains constant regardless of changes in conditions, such as filter loading Velocities of airflow and temperature are inspected at real-time, and indicated on the control panel Alarm thresholds (±10% of the control point) are precisely controlled via microprocessor which guarantees excellent airflow performance ULPA Filtration System HFsafe LC biosafety cabinets are equipped with long life ULPA filtration technology by Swedish Camfil Farr Supply and exhaust filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns, providing superior product protection over conventional HEPA filters. Silicate glass fiber treated with moisture-proof hydrophobic bonding agent is folded in aluminum alloy frame to enlarge filtration area. Leak-free performance is guaranteed through structural stability and scan test conducted prior to shipping. Self-compensation for the clogging of filters optimizes filter use and minimizes service. Friendly Communication The durable LCD is mounted at eye level for at-a-glance viewing of airflow, operating parameters, and alarm messages. The intuitive interface delivers a constant read-out of working area temperature, air velocity/volume, filter life span, total running time. Easy-to-clean touchpad controls allow manual activation of blower, lamp, UV, electrical receptacles and menu selection. Engage the security lock feature to prevent access to the cabinet by unauthorized or unfamiliar users. Robust Construction & Compact Design Energy saving epoxy/polyester coated steel exterior with solid construction, nice looking curves and fresh colour Constructed of seamless, non-porous, autoclavable Type 304 stainless steel for working plate, one-piece side/rear walls and bottom sink. Slim, compact design and dimensions allows for easy positioning and location in the laboratory, can be easily transported through standard 800 mm doorways. The low cabinet height allows the choice of bench top location or mounting on a support stand, easily accommodated in a laboratory with 2.5m ceiling height. Tailor-made Cabinets Special cabinets are manufactured as per customer s requirements on demand. Applications ENVAIR eco safe Classic Microbiological Safety Cabinets have been adopted worldwide in use for product, personnel and environmental protection while handling harmful agents pathogenic to human beings and/or animals as defined in the appropriate International Standards, in a wide range of disciplines in applications such as: Microbiology, Virology, Haematology, Cell culture, Genetics, Handling of hazardous agents to human beings or animals.
Technical specifications A2 Nominal size 0.9m (3') 1.2m (4') 1.5m (5') 1.8m (6') External Dimensions with Base Stand (D W H) Internal Work Area, Dimensions (D W H) 771 1023 2255 mm 30.4" 40.3" 88.8" 600 900 678 mm 23.6" 35.4" 26.7" 771 1323 2255 mm 30.4" 52.1" 88.8" 600 1200 678 mm 23.6" 47.2" 26.7" 771 1623 2255 mm 30.4" 63.90" 88.8" 600 1500 678 mm 23.6" 59.1" 26.7" 771 1923 2255 mm 30.4" 75.7" 88.8" 600 1800 678 mm 23.6" 70.9" 26.7" Internal Work Area, Space 0.54 m2 (5.8 sq.ft) 0.72 m2 (7.8 sq.ft) 0.9 m2 (9.7 sq.ft) 1.08 m2 (11.6 sq.ft) Average Airflow Velocity* Inflow 0.53 m/s (104.3 fpm) 0.53 m/s (104.3 fpm) 0.53 m/s (104.3 fpm) 0.53 m/s (104.3 fpm) Downflow 0.35 m/s (68.9 fpm) 0.35 m/s (68.9 fpm) 0.35 m/s (68.9 fpm) 0.35 m/s (68.9 fpm) Airflow Volume Inflow 363 m³/h (213 cfm) 477 m³/h (281 cfm) 592 m³/h (348 cfm) 706 m³/h (416 cfm) Downflow 658 m³/h (377 cfm) 866 m³/h (510 cfm) 1075 m³/h (633 cfm) 1282 m³/h (755 cfm) Exhaust 363 m³/h (213 cfm) 477 m³/h (281 cfm) 592 m³/h (348 cfm) 706 m³/h (416 cfm) ULPA Filter Typical Efficiency Downflow Exhaust Biosafety Protection Test Personnel Protection Test KI-Discus containment and microbiological testing is performed Product Protection Test 1~8 106 5CFU 5CFU 5CFU 5CFU Cross-contamination Test 1~8 106 2CFU 2CFU 2CFU 2CFU Sound Emission (Typical) NSF/ANSI 49 <52 dba <54 dba <54 dba <57 dba EN 12469 <49 dba <51 dba <52 dba <54 dba Fluorescent Light Intensity 800~1200 Lux (74~112 foot candles) Excellent light distribution Yes Yes Yes Yes RMS 2.3μm 2.3μm 2.3μm 2.3μm Cabinet Construction Main Body 1.2 mm (0.05") steel with white oven-baked epoxy-polyester Work Zone 1.5 mm (0.06") stainless steel, type 304 Side Walls 1.5 mm (0.06") stainless steel, type 304 Electrical sliding windows Option Yes Yes Yes Yes Window material Hardened/laminated safety glass Electrical Cabinet Full Load Amp (FLA) 2A 2A 4A 4A Fuses 10A 10A 10A 10A Cabinet Nominal Power 190W 220W 280W 390W Optional Outlets FLA 5A 5A 5A 5A Total Cabinet FLA 7A 7A 9A 9A Power Supply* 220 V / 50 Hz Yes Yes Yes Yes 220 V / 60 Hz Yes Yes Yes Yes 110 V / 60 Hz Yes Yes N/A N/A Net Weight Manual Type 120 kg (264 lbs) 225 kg (496 lbs) 280 kg (617 lbs) 320 kg (805 lbs) Shipping Weight Manual Type 175 kg (386 lbs) 295 kg (650 lbs) 350 kg (772 lbs) 320 kg (860 lbs) Shipping Dimensions Maximum (D W H) 945 1125 1717mm 37.2" 46.3" 67.3" 945 1425 1717mm 37.2" 56.1" 67.3" 945 1725 1717mm 37.2" 67.9" 67.3" 945 2026 1717mm 37.2" 79.8" 67.3" Shipping Volume, Maximum 1.81 m³ (64 cu.ft.) 2.30 m³ (81.2 cu.ft.) 2.79 m³ (99 cu.ft.) 3.27 m³ (115.5 cu.ft.) * Please contact us for more optional power supply information
Technical specifications B2 Nominal size 0.9m (3') 1.2m (4') 1.5m (5') 1.8m (6') External Dimensions with Base Stand (D W H) Internal Work Area, Dimensions (D W H) 710 1040 2130 mm 30.0" 40.9" 83.9" 575 950 625 mm 22.6" 37.4" 24.6" 710 1340 2130 mm 30.0" 52.8" 83.9" 575 1250 625 mm 22.6" 49.2" 24.6" 710 1640 2130 mm 30.0" 64.6" 83.9" 575 1550 625 mm 22.6" 61.0" 24.6" 710 1940 2130 mm 30.0" 76.4" 83.9" 575 1850 625 mm 22.6" 72.8" 24.6" Internal Work Area, Space 0.54 m2 (5.8 sq.ft) 0.72 m2 (7.8 sq.ft) 0.9 m2 (9.7 sq.ft) 1.06 m2 (11.4 sq.ft) Average Airflow Velocity* Inflow 0.53 m/s (104.3 fpm) 0.53 m/s (104.3 fpm) 0.53 m/s (104.3 fpm) 0.53 m/s (104.3 fpm) Downflow 0.30 m/s (59.1 fpm) 0.30 m/s (59.1 fpm) 0.30 m/s (59.1 fpm) 0.30 m/s (59.1 fpm) Airflow Volume Inflow 363 m³/h (214 cfm) 477 m³/h (281 cfm) 592 m³/h (348 cfm) 706 m³/h (416 cfm) Exhaust 927 m³/h (546 cfm) 1220 m³/h (718 cfm) 1515 m³/h (892 cfm) 1805 m³/h (1062 cfm) ULPA Filter Typical Efficiency Downflow Exhaust Biosafety Protection Test Personnel Protection Test KI-Discus containment and microbiological testing is performed Product Protection Test 1~8 106 5CFU 5CFU 5CFU 5CFU Cross-contamination Test 1~8 106 2CFU 2CFU 2CFU 2CFU Sound Emission (Typical) NSF/ANSI 49 <52 dba <54 dba <54 dba <57 dba EN 12469 <49 dba <51 dba <52 dba <54 dba Fluorescent Light Intensity 800~1200 Lux (74~112 foot candles) Excellent light distribution Yes Yes Yes Yes RMS 3μm 3μm 3μm 3μm Cabinet Construction Main Body 1.2 mm (0.05") steel with white oven-baked epoxy-polyester Work Zone 1.5 mm (0.06") stainless steel, type 304 Side Walls 1.5 mm (0.06") stainless steel, type 304 Electrical sliding windows Option Yes Yes Yes Yes Window material Hardened/laminated safety glass Electrical Cabinet Full Load Amp (FLA) 4A 4A 5A 5A Fuses 10A 10A 10A 10A Cabinet Nominal Power 850W 855W 1200W 1200W Optional Outlets FLA 5A 5A 5A 5A Total Cabinet FLA 9A 9A 10A 10A Power Supply* 220 V / 50 Hz Yes Yes Yes Yes 220 V / 60 Hz Yes Yes Yes Yes Net Weight Manual Type 210 kg (463 lbs) 250 kg (551 lbs) 295 kg (650 lbs) 340 kg (750 lbs) Shipping Weight Manual Type 260 kg (573 lbs) 310 kg (686 lbs) 365 kg (804 lbs) 420 kg (926 lbs) Shipping Dimensions Maximum (D W H) 945 1125 1717 mm 37.2" 44.3" 67.3" 945 1425 1717 mm 37.2" 56.1" 67.3" 945 1725 1717 mm 37.2" 67.9" 67.3" 945 2026 1717 mm 37.2" 79.8" 67.3" Shipping Volume, Maximum 1.81 m³ (64 cu.ft.) 2.30 m³ (81.2 cu.ft.) 2.79 m³ (99 cu.ft.) 3.27 m³ (115.5 cu.ft.) * Please contact us for more optional power supply information
Service in pure culture Envair offers service in pure culture. We do not simply sell our units to you but will assist you gladly from A to Z. Delivery: We deliver all units ex works. Set-up service and packaging disposal are included upon request. Service: 24h at site service and 24h free of charge phone hotline 7 days a week Spare parts guaranty: 10 years Availability within 24h Ex stock Emmendingen Qualification: IQ/OQ GMP GAMP 21 CFR Part 11 Decontamination: We carry out microbiological decontaminations with most modern H2O2 generators in Cleanrooms, Isolators and Safety Cabinets. Maintenance: Microbiological Safety Cabinets DIN 12469 Cytotoxic Dispensing Cabinets with KI-discus test DIN 12980 Laminar Flow Cabinets Laboratory Fume Hoods Cytotoxic Dispensing Isolator EN 14644-7 Isolator EN 14644-7 Cleanrooms Autoclaves CO2 Incubator PCR Thermal Cycler Real Time Thermal Cycler Centrifuge Water purification Ultra Low Temperature Freezer -86 C Service by professional staff. All works are carried out by service technicians qualified by TÜV Nord Maintenance contract: Regular terms of maintenance increase your safety. With a maintenance contract we guarantee the complete check of all functions of your units. We will contact you reliably in regular terms. Guaranty and Warranty: Combined with an ENVAIR maintenance contract we offer a 2-year warranty to all units. Excepted are consumables and wearing parts as well as compressed air components. Legend: TÜV-tested Work zone rear wall varnished Hinged front visor for optimal cleaning Media connections installed electrical sockets installed Stainless steel work zone rear wall Ergonomic Low power consumption 1.0 2016/07 Should you have requirements which need to be discussed and agreed upon, please contact ENVAIR.