Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Similar documents
Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

Inductive slot sensor

PEPPERL+FUCHS GmbH

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR DP 7060 Supplementary Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

VERSAFLOW VORTEX Supplementary instructions

MANUAL Oil Level Sensor

EU DECLARATION OF CONFORMITY

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Annubar Flowmeter Series

Safety instructions VEGAPULS 64

SEK-3 Marine Grounding System

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Operating Instructions Edition 02/2007

AND INSTALLATION MANUAL

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

MANUAL Overflow sensor NVF-104/34-PF

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Supplementary Installation and Operating Instructions. Category II2G

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

4) Intrinsic Safety Certification

OPTIWAVE X500 Supplementary Instructions

Certificate of Compliance

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

SET Installation and Operating Instructions. Level switch for one sensor

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

IECEx Certificate of Conformity

OilSET-1000 (12 VDC)

DB5 Intrinsically Safe Sounder Type DB-5

Declaration of conformity

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Installation and Operating Instruction

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

SET-2000 Hi Level/Oil

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Certificate of Compliance

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Survey of electrical equipment installed in hazardous areas on tankers

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multisensor fire detector

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Solutions

Certificate of Compliance

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

FDOOT241-A9-Ex Multisensor fire detector

Rosemount 752 Fieldbus Remote Indicator

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

SET-2000 Oil/Sludge 12 VDC

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Temperature Measurement Transmitters for field mounting

UL HAZARDOUS LOCATIONS SERVICES

Certificate of Compliance

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,


IECEx Certificate of Conformity

INSTRUCTION & SERVICE MANUAL

RT FLOW RATE TOTALISER

Model 144H. Product Data Sheet , Rev DB February Content

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Operating Manual MS220DA

Product Information to the manual

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Multipoint temperature sensor

Certificate of Compliance

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Certification Supplement Manual

Temperature sensors SensyTemp TSP Measuring insets TSA

Transcription:

0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product s documentation. Accessories BF 18 Mounting flange, 18 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation flush Output polarity Safety Function Assured operating distance s a 0... 4.05 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage U o 8 V DC Switching frequency f 0... 500 Hz Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Ambient conditions Ambient temperature -40... 100 C (-40... 212 F) Mechanical specifications Connection type cable silicone, 2 m Core cross-section 0.75 mm 2 Housing material PP Sensing face PP Degree of protection IP68 information Use in the hazardous area see instruction manuals Category 1G; 2G; 3G; 1D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165F UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions M18 x 1 44 1 35.5 39 24 Electrical Connection BN BU L+ L- 1

ATEX 1G Device category 1G EC-Type Examination Certificate PTB 00 ATEX 2049 X II 1G Ex ia IIC T6 Ga Standards EN 60079-0:2009, EN 60079-11:2012, EN 60079-26:2007 Ignition protection "Intrinsic safety" Appropriate type NJ 5-18GK-SN... 120 nf ; a cable length of 10 m is considered. 200 µh ; a cable length of 10 m is considered. Cable length Dangerous electrostatic charges on the fixed connection cable must be taken into account for lengths equal to and exceeding the following values: Explosion group IIA 78 cm Explosion group IIB 39 cm Explosion group IIC 6 cm and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. Electrostatic charging When used in group IIC non-permissible electrostatic charges should be avoided on the plastic housing parts. 2

ATEX 2G Device category 2G EC-Type Examination Certificate PTB 00 ATEX 2049 X II 1G Ex ia IIC T6 Ga Standards EN 60079-0:2009, EN 60079-11:2012 Ignition protection "Intrinsic safety" Appropriate type NJ 5-18GK-SN... 120 nf ; a cable length of 10 m is considered. 200 µh ; a cable length of 10 m is considered. and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. 3

ATEX 3G (nl) Note This instruction is only valid for products according to EN 60079-15:2003, valid until 31-May-2008 Device category 3G (nl) Standard conformity Maximum permissible ambient temperature T Umax at Ui = 20 V for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Connection parts II 3G EEx nl IIC T6 X The Ex-significant identification is on the enclosed adhesive label EN 60079-15:2003 Ignition protection category "n" 120 nf ; A cable length of 10 m is considered. 200 µh ; A cable length of 10 m is considered. and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-15. The explosion group depends on the connected and energy-limited supply circuit. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! 70 C (158 F) 85 C (185 F) 69 C (156.2 F) 84 C (183.2 F) 51 C (123.8 F) 66 C (150.8 F) 80 C (176 F) 39 C (102.2 F) 54 C (129.2 F) 61 C (141.8 F) The sensor must not be mechanically damaged. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 4

ATEX 3G (ic) Device category 3G (ic) Certificate of Compliance PF 13 CERT 2895 X Standards Maximum permissible ambient temperature T Umax at Ui = 20 V for Pi=34 mw, Ii=25 ma, T6 for Pi=34 mw, Ii=25 ma, T5 for Pi=34 mw, Ii=25 ma, T4-T1 for Pi=64 mw, Ii=25 ma, T6 for Pi=64 mw, Ii=25 ma, T5 for Pi=64 mw, Ii=25 ma, T4-T1 for Pi=169 mw, Ii=52 ma, T6 for Pi=169 mw, Ii=52 ma, T5 for Pi=169 mw, Ii=52 ma, T4-T1 for Pi=242 mw, Ii=76 ma, T6 for Pi=242 mw, Ii=76 ma, T5 for Pi=242 mw, Ii=76 ma, T4-T1 Connection parts II 3G Ex ic IIC T6 Gc The Ex-significant identification is on the enclosed adhesive label EN 60079-0:2009, EN 60079-11:2012 Ignition protection category "ic" 120 nf ; A cable length of 10 m is considered. 200 µh ; A cable length of 10 m is considered. and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! must be observed. The sensor must only be operated with energy-limited circuits, which satisfy the requirements of IEC 60079-11. The explosion group depends on the connected and energy-limited supply circuit. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! 70 C (158 F) 85 C (185 F) 69 C (156.2 F) 84 C (183.2 F) 51 C (123.8 F) 66 C (150.8 F) 80 C (176 F) 39 C (102.2 F) 54 C (129.2 F) 61 C (141.8 F) The sensor must not be mechanically damaged. The connection parts are to be installed, such that a minimum protection class of IP20 is achieved, in accordance with IEC 60529. 5

ATEX 1D Device category 1D for use in hazardous areas with combustible dust EC-Type Examination Certificate ZELM 03 ATEX 0128 X Standards Appropriate type Maximum housing surface temperature Electrostatic charging II 1D Ex iad 20 T 108 C (226.4 F) The Ex-significant identification is on the enclosed adhesive label IEC 61241-11:2002: draft; pren61241-0:2002 type of protection intrinsic safety "id" NJ 5-18GK-SN... 120 nf ; a cable length of 10 m is considered. 200 µh ; a cable length of 10 m is considered. and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! The maximum surface temperature of the housing is given in the EC-Type Examination Certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iad. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. The intrinsically safe circuit has to be protected against influences due to lightning. The adhesive label provided must be affixed in the immediate vicinity of the sensor! The surface to which the label is applied must be clean, flat and free from grease! The affixed adhesive label must be readable and durable, taking account of the possibility of chemical corrosion! When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The applicable directives and standards must be observed. The connection cables are to be laid in accordance with EN 50281-1-2 and must not normally be subjected to chaffing during use. 6