ALARM FOR SAFETY CABINETS SPECIFICATIONS

Similar documents
AIRFLOW SPECIFICATIONS

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

AirGard. Air Flow Monitors

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Fume Hood Operating Display Panel

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

BX444-Mc Gas Detector

Installation & Calibration Guide

AFA 500 FUME HOOD ALARMS

Door Release Power Supply

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Static Pressure Alarm For Hazardous Location Fume Hoods

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

APM110 LOW AIR VELOCITY ALARM

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Model 405 AIRGARD Fume Hood Monitor

Emotron M10 Shaft Power Monitor. Instruction manual English

AWL AIRCRAFT WARNING LIGHT MIOL-AC & MIOL-C TYPE OPERATION AND MAINTENANCE MANUAL

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

X10 Mini, Midi & Maxi

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

METEOROLOGICAL INSTRUMENTS

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Room thermostat with Auto Timer, Option External Input

Room thermostat with Auto Timer, independent DHW

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Touchpoint Plus. A whole new control experience

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

AFA1000/1 MK3 Airflow Monitor

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

CommStat 4 Controller

Technical Manual. Level Alarm Unit CARLA & WIDS

GS100M Gas Detection Controller

Room thermostat with Auto Timer, Option External Input

ELECTRONIC SOUNDER STROBE Model : AVD-C407

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

Movement Detector GJD 300

LABCONCO 1000 GUARDIAN DIGITAL MONITOR Operating and Instruction Manual

MODEL MARINE WIND TRACKER

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

AirGard 385 Fume Hood Monitor

AO Annunciator Module

FUME HOOD MONITOR ALNOR AIRGARD 200

Entero Voice Alarm system.

DIESEL Engine Fire Pump Controllers Features

Room thermostat with Auto Timer, Option External Input

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

RPM1600 Series Room Pressure Monitors

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

FCCP 200: Fume-cupboard indicator and monitor

CA5000 Liquid CO 2 Freezer Backup System

Excel-EN Conventional Fire Control Panel

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

ACCESSOIRES ELECTRICAL ACCESSORIES

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Entero Voice Alarm system. User guide

Conventional Fire Alarm System 2014 V1.2

GAS SUPRESSION CONTROL PANEL:

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

VEHICLE EXHAUST DETECTOR

THX-DL Data Logger USER & INSTALLATION MANUAL V

ELECTRO-FENCE TM. Fence Protection System. Installation Manual. EF_Install_V2

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

METEOROLOGICAL INSTRUMENTS

BC-R10 Series. Burner Controllers

ANALOX 3000 Carbon Monoxide Monitor

Obelux MI-2KR-A Page 1/5 ICAO Medium Intensity Type B and C, FAA L-864 and L-885, cd flashing / fixed red obstacle light

Room thermostats with LCD RDD100..

Manual Vane Anemometer PCE-VA 20

Oakton TEMP 9500 Advanced Multiparameter Controller

Flopurge TS. Operation Manual

Model # Airflow Monitor Warranty. Installation, Operation, Maintenance Manual. Analog Airfl ow Monitor Model Number #51403

METEOROLOGICAL INSTRUMENTS

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

Dräger REGARD -1 Control System

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Centro-Matic Automated Lubrication Systems System Controls

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Intelligent Security & Fire Ltd

FUME HOOD MONITOR ALNOR AIRGARD 335

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

MODEL WIND TRACKER

Duct Air Quality Sensors

SPACEMOTION SERIES SMM 01

SENTINEL A - Fault Passage Indicator

Tower & Obstruction Lighting Controls

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Transcription:

ALARM FOR SAFETY CABINETS SPECIFICATIONS Parc Technologique Delta Sud * 09340 Verniolle * France Tel + 33 5 61 69 84 43 * fax + 33 5 61 67 86 03 info@seat-ventilation.com * www.seat-ventilation.com 1

Benefits GENERAL DESCRIPTION International Standards Compliance Ease of installation and maintenance Attractive design Digital display in m/s or FPM Applications: safety cabinets or hoods Features Audible and visual alarm 3 Push buttons: Fan ON/OFF, light ON/OFF, Mute Alarm for past time Options Alarm relay: An alarrm relay can be installed optionnaly. Battery back up: Red LED alarm is still functional up to 6h when unit loses power. Digital display in m/s or FPM Colors Plastic fascia is available in 3 colours:white, black and yellow. - CEM Electromagnetic Compatibility EN 61326:1997 / A1 : 1998 /A2 : 2001 / A3 : 2003 (Test RC-05-42060-1) US FCC Part 15 Class B edition 2005 (Test report RC-05-42060-2-A). - RoHS directive - Laboratory French standard XPX 15206 January. 2005 - CE - Labour regulation Nr R4222-13 (Alarm for safety cabinets containing dangerous products) Components Circuit board with sensor included Panel mounted circuit board to be installed horizontally onto cabinet with 2X2,8 mm screws; IP55 protection ensured by O seal ring; Face plate is supplied with chemical resistent plastic sticker (horizontal) with control/push buttons on fascia; Mounting box is included. Power supply 230Vac to 12Vdc power transformer directly into alarm circuit board. Packing Supplied in cardboard box which includes controller circuit board, O seal ring, power supply 220/12V and mounting box. 2

OPERATING PRINCIPLE When the fume extraction fan is running, it causes negative pressure inside the safety cabinet or hood. While normal operation (closed doors) the pressure is intense, the front air velocity is constant. If the doors are opened, the pressure becomes less intense and air velocity decrease. If an opening is made in the wall of the cabinet, air will enter in at a velocity determine by the same negative pressure that is drawing air in the front of the safety cabinet. The obtained air velocity level measurement by using the numerical sensor is displayed on the fascia by LED illumination or digital read out. An audible alarm will sound in case of opened doors or exhaust fan failure. The alarm timer count the safety cabinet uptime. It allows to check the filters and installation situation in accordance with recommendation. The setting is made from 0 to 100h and from 5 to 365 days. 3

LED & DIGITAL DISPLAY Power supply 220V/12v Dc Alarm for past time + Alarm -Opened door -Fan OFF or failing Light relay On/Off SEAT exhaust fan 4

SPECIFICATIONS LED version Digital display version References 819698 819697 Digital display Led 1 green LED Air flow Ok 1 flashing red LED for Alarm No digital display 1 green LED Air flow OK 1 flashing red LED for Alarm 3 digits display with velocity reading Units N/A Meter par second (m/s) or FPM Display range N/A 0-2.00 m/s Alarm past time 1 flashing Led 5% remaining time 2 constant Leds past Time 1 flashing Led 5% remaining time 2 constant Leds past Time Alarm delay Selectable 15s or 30s Selectable 15s or 30s Alarm Indication Alarm mute button Light On/Off button Fan On/Off button 1 flashing red LED and audible Buzzer 1 flashing red LED and and audible Buzzer Alarm relay Yes (optional) Yes (optional) Battery back up Yes (optional) Yes (optional) Alarm past time Audible and visual Audible and visual Mounting Mounting box Mounting box Calibration Power supply Factory pre-calibaretd @ 0.5m/s. Recalibration possible 12Vdc (power supply included 220v:12v) Factory pre-calibrated @ 0.5m/s. Recalibration possible 12Vdc (power supply included 220v:12v) Orientation Horizontal Horizontal Dimensions Front fascia: 210L x 75lx 10H mm Mounting box: 205L x 75l x 25H mm Front fascia: 210L x 75l x 10H mm Mounting box: 205L x 75l x 25H mm 5

Alarm+mounting box DIMENSIONS 25 75 A tube of diameter 22 mm and lenght 30cm is supplied for a head measurement. Mounting box 20 Face plate Screw Ø 2.8 210 6

OVERALL VIEW Front plate Digital display 1 green LED Air flow OK 1 red LED Air speed too low Fan ON/OFF button Alarm mute push button Light ON/OFF button 1 flashing LED 5% remaining time 2 constant LEDS for past time Alarm for past time 7