BioMAT 2 BioMAT 2-S2. Class 2 Microbiological. Safety Cabinets. Simple. Safe. Quiet. Efficient. To EN 12469:2000

Similar documents
Class II ECO Generation 8 Microbiological Safety Cabinet

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

BioMAT 2 Safety Cabinet

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Gelaire BH-EN and UltraSafe cabinets

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

Environmental Health and Safety Biological Safety Program Guidance Document

LABORATORY CABINETS 103

INCREASE YOUR LAB EFFICIENCY

Laboratory Automation & Robotic System Enclosures

Thermo Scientific 1300 Series A2

Biological Safety Cabinets or Fume Hoods Which one to use?

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

INCREASE YOUR LAB EFFICIENCY

CIRCULAIRE FORMALIN CONTAINMENT SYSTEMS.

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

Ergonomic and Green Class II s

UVC/T-AR UVC/T-M-AR UVT-S-AR

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

The ultimate microbiological safety cabinet

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

HERAEUS HERASAFE KS SAFETY CABINET CLASS II. Safety. Everything you need more than you expect

CLEAN AIR SYSTEM.

Quick Reference Guide to Cabinet types

Flexible Solutions. Reliable Results. Hypoxic Chambers: O 2 Control Cabinets for InVivo Studies. ÂÂHyperoxic. ÂÂPathologic ÂÂIntermittent Hypoxia

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

Control of Biological Hazards

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

Mars Pro. Mars Pro. Ultrasafe Class 2 An Ultrasafe Triple Filter - Microbiological Safety Cabinets. Cytosafe 3 filter Class 2 cabinets

Safe Operating Procedure (Revised 2/10)

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

2 Microbiological Safety Cabinet

6/19/2015 BIOLOGICAL SAFETY CABINET. Types of Classes. Types of BSC.

Thermo Scientific HERAsafe Microbiological Safety Cabinets Advanced operator and product protection

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Aseptic Barrier Systems

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

Fume Hood Safety TYPES OF FUME HOODS

PART III. Laboratory equipment

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

LAMINAR FLOW FOR ALL YOUR NEEDS

Innovation in air purification unmatched air quality

Fortuna. Fortuna. »ScanLaf Probably the best in Class 1, Class 2 and Laminar flow technology.

INCREASE YOUR LAB EFFICIENCY

L a b o r a t o r y E q u i p m e n t C a t a l o g

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

Labexia 820 LX. Undercounter Laboratory Glassware Washer Dryer. A big washer for small spaces! Accessories

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Mars. Mars Class 2. Microbiological Safety Cabinets. ScanLaf...Advanced Designs for your Safety & Comfort. Class 2 Safety Cabinets

ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations

Biological Safety Cabinets. Biological Safety Cabinets

USER MANUAL ADVANCED BIO SAFETY CABINET (ABS) CLASS II. TM020-O&M-001 Revision 5 Page 1 of 68

Howorth Air Technology. Pharmaceutical Containment Solutions

Installation manual Mori HR

**BVC professional G

Biological Safety Cabinet

INCREASE YOUR LAB EFFICIENCY

G Installation manual Solitude - dmev unit

CHEMICAL FUME HOOD PROGRAM

L E C M E D I C A L LABORATORY FREEZERS

Howorth Air Technology. Pharmaceutical Containment Solutions

FUME CUPBOARDS DESIGN FEATURES GENERAL ARRANGEMENT FACE VELOCITIES EXTRACTION SYSTEMS AIRFLOW CHARACTERISTICS

OPERATION AND MAINTENANCE MANUAL

Considering Filtration. Austin Baker Ventilation Director Hog Slat, Inc

Technical Catalog laboratory furniture system

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

LAMINAR FLOW AND VENTILATED SOLUTIONS FOR ALL YOUR NEEDS

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station

air handling units AT THE LEADING EDGE OF AIR FLOW

IVF/ART Series Laminar Flow Cabinets

XPert Balance and Bulk Powder Enclosures

i Van Intelligent Control Panel

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

BIOLOGICAL SAFETY CABINET

Appendix C IBC Safe Use of Biosafety Cabinets SOP

Laboratory Division. Product Range Cold Storage Clean Air Lyo

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Chemistry diaphragm pumps

**BVC control G. * With 4l PP collection bottle for general aspiration tasks, completely autoclavable together with a 0.2 µm protection filter

Sparkfree Refrigerators ATEX Certified

Pharmacy Refrigerator

Setting new Standards for Safety Containment. Comfort. Convenience. Thermo Scientific HERASAFE KS and KSP Class II Biological Safety Cabinets

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

Maximum protection for your health and well-being

VP, Facilities and Construction Management

Technical Catalogue laboratory furniture system

Performance on demand

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Laboratory Fume Cupboards

Microbiological Safety Cabinets

Transcription:

BioMAT 2 BioMAT 2-S2 Class 2 Microbiological Safety Cabinets To EN 12469:2000 Simple Safe Quiet Efficient

BioMAT 2 and BioMAT 2-S2 Class 2 Microbiological Safety Cabinets Significant upgrades make the new BioMAT 2 the most simple, safe, quiet and efficient model to date The 6th generation BioMAT 2 brings together decades of experience in containment design to provide a range of Class 2 Microbiological Safety Cabinets, simple and safe to use and maintain, quiet and energy efficient in operation. Application BioMAT 2 Microbiological Safety Cabinets provide both operator and product protection for the routine handling of biological agents up to Hazard Group 3 (ACDP Publication - Categorisation of Pathogens according to Hazard and Categories of Contaminant 1990). www.containedairsolutions.co.uk

BioMAT 2 and BioMAT 2-S2 Class 2 Microbiological Safety Cabinets BioMAT 2 Class 2 Microbiological Safety Cabinet Complies with BS EN 12469:2000 DOWNFLOW SAFE INFLOW SAFE 13:58 Simple to use Intuitive controls with crystal clear iconography for ease of operation. 10cm x 6cm TFT touch screen providing real time indication of cabinet operation with dynamic animated airflow diagram. Engineers menu allows rapid and simple adjustment of cabinet fan speed and UV light time function. Simple four digit password protection offers users simple and quick security in maintaining cabinet operations. Efficient operation Animated airflow diagram provides real time indication Energy efficient EC fan technology coupled with low of cabinet status loss filters, LED lighting and energy efficient controls provide significantly reduced power consumption. Typical running consumption: 140W based on a Class 2 cabinet operational performance of 0.6 m/sec inflow and 0.35m/sec downflow. Set back mode detects unattended cabinet operation and automatically closes visor to 50mm, extinguishes lights and reduces fan speed to maximise energy efficiency (BioMAT 2-S2). DOWNFLOW SAFE INFLOW 13:58 SAFE DOWNFLOW LOW INFLOW 13:58 LOW Safe operation Full width LED light function gives operator unparalleled clear unambiguous indication of any airflow problem. Animated airflow diagram provides the operator with instant clear indication of any abnormal cabinet status. Quiet operation All models are equipped with EC fans, additional attenuation, low pressure HEPA filters and noise reduction technology ensures the lowest possible noise levels. Typical noise level now 49dBA (1200mm models). VISOR OPEN 13:58 Tel: +44(0)161 655 8860

Features The BioMAT 2 range of Class 2 Microbiological Safety Cabinets provide a flexible design platform allowing users to select a cabinet to meet their exact laboratory requirement. Fans Latest generation EC fan technology provides reduced noise levels with improved energy efficiency Exhaust Cabinets can be provided in standard exhaust, thimble, re-circulation or our unique patented TriMAT constant exhaust format to meet the particular application Controls Tactile control buttons with crystal clear iconography provide simple clear control of cabinet operation and functions Indications TFT touch screen complete with animated airflow diagram provides real-time indication of cabinet status under all operating conditions Alarms Audible alarms coupled with large red LED light alerts operator to any cabinet/airflow malfunction Side glazing Provides users with a bright open working environment and a flexible solution for the addition of future services Front visor Available in 200mm fixed aperture or motorised sliding sash to suit user preference Worktrays Manufactured in grade 316 stainless steel as standard. Available as a single dished unit or divided sections to suit users needs Support Stand Fixed height, manually adjustable or fully DDA compliant electrically operated motorised stands as required www.containedairsolutions.co.uk

Features Divided worktrays Side view Red LED visual alarm indication Single piece worktray Fixed aperture door with night door Tel: +44(0)161 655 8860

Models BioMAT 2 BioMAT 2-S2 The BioMAT 2 offers the proven 200mm fixed aperture design provided by all previous cabinet generations. The visor is secured by simple slidelocks and closure is achieved using a night door supplied with each cabinet. The BioMAT 2 S2 offers an aerosol tight motorised sliding sash front visor, operated using simple up/down arrows on the main control panel. The sliding sash is normally set at 200mm for standard cabinet operation but can be raised to allow passage of large items into the main cabinet working area or lowered to close and seal the cabinet as required. The S2 visor also incorporates an anti trap function which automatically raises the glass visor in the event that an obstruction is detected and a set back mode which lowers the visor to 50mm and switches off lights when the cabinet is left unattended to maximise energy efficiency. Exhaust Options Standard exhaust Ducted type with exhaust module incorporating single HEPA filter and integral anti blowback damper Thimble exhaust Exhaust module incorporating double HEPA filters and integral anti blowback damper Re-circulation Exhaust module incorporating double HEPA filters and vertical or horizontal discharge grille for return air back into the laboratory TriMAT Unique patented (UK Patent No GB2501283) constant bypass exhaust module designed specifically for use in containment level 2 & 3 facilities Lab air Filtered air Contaminated air Normal operation Normal operation Emergency operation Normal Operation - Cabinet ON Normal Operation - Cabinet OFF Emergency Operation -Room Extrat Fail Cabinet on Cabinet off Room extract fail Lab Air Filtered Air Contaminated Air www.containedairsolutions.co.uk

Technical Specifications Features BioMAT 2 1200mm* BioMAT 2 1500mm BioMAT 2 1800mm External width 1200mm 1500mm 1800mm Internal width 1110mm 1410mm 1710mm External depth 705mm 705mm 705mm Internal depth 560mm 560mm 560mm External height 1420mm 1540mm 1540mm Internal height 680mm 680mm 680mm Air volume (typ.) 0.13m3/sec 0.17m3/sec 0.21m3/sec Power consumption 140W 200W 350W Noise level 49dBA 52dBA 58dBA Weight 240kg 280kg 330kg Cabinet construction 1.5mm mild steel Paint finish Traffic white RAL 9016 Inner liner Grade 304 stainless steel Side windows 5mm UV resistant toughened glass Fumigation options Front visor BioMAT 2 Front visor BioMAT 2-S2 Standard Formaldehyde or vaporised hydrogen peroxide 5mm toughened glass with 200mm open aperture closed for fumigation using a night door (supplied) Aerosol tight 5mm sliding sash front visor operated via simple up/down buttons on control panel, incorporating anti trap reverse function Type tested and approved to EN12469:2000 *1200mm internal working width model also available on request Accessories Support Stands: Fixed, adjustable or DDA compliant electrically operated (750mm to 1050mm operating range) Service taps, vacuum, laboratory gases etc Solenoid operated gas valves UV germicidal light with programmable timer function Detachable Arm rest Tel: +44(0)161 655 8860

Also in the range BioMAT Class 1 Microbiological safety cabinets Operator protection cabinets to the requirements of EN 12469:2000 BioMAT Class 3 Microbiological safety cabinets Full barrier high hazard protection cabinets to the requirements of EN 12469:2000 CAS Robotics Enclosures Class 1 or 2 controlled environments to house robotic instruments for automated processes H-MAT Clean air workstations To the requirements of BSEN 14644 IsoMAT Positive or negative pressure 2 or 4 glove pharmaceutical isolators CAS Tables Ventilated tables Available in a variety of sizes and materials Contained Air Solutions is the largest domestic manufacturer of Microbiological safety Cabinets and associated clean air products in the United Kingdom. All products are 100% designed and manufactured in our Manchester production facility which has been approved to the ISO9001:2000 Quality Assurance Standard. We provide a large range of standard and engineered product solutions to meet the precise needs of laboratory users. All CAS products are installed and commissioned by our own fully trained personnel to ensure maximum operational safety, performance and reliability. We also offer comprehensive after sales service and support, advice and guidance on all aspects of Microbiological Safety Cabinet design, operation and safe use. Visit us: www.containedairsolutions.co.uk Unit 4, Greengate, Middleton Junction, Manchester, M24 1RU. Tel: +44(0)161 655 8860 Fax: +44(0)161 655 8865

Wolf Laboratories Limited www.wolflabs.co.uk Tel: 01759 301142 Fax:01759 301143 sales@wolflabs.co.uk Use the above details to contact us if this literature doesn't answer all your questions. Pricing on any accessories shown can be found by keying the part number into the search box on our website. The specifications listed in this brochure are subject to change by the manufacturer and therefore cannot be guaranteed to be correct. If there are aspects of the specification that must be guaranteed, please provide these to our sales team so that details can be confirmed.