OPERATION MANUAL Part No s. P8003V10C, P8004V10C

Similar documents
OPERATION MANUAL Part No. s - MAG2000, MAG2000M

OPERATION MANUAL Part No. MIL8001V4C

WDB2 Series Bearing Temperature Sensor

OPERATION MANUAL Part No. T4004NV46C / T4004NV4C

R500E MANUAL (Software Version 2.0)

A400E MANUAL A4004V4C & A4004V46C. Important: This document should be read carefully before commencing installation

F500 Elite. FIELDBUS ADAPTER. Watchdog NTC to Modbus RTU communications. (Software Version 3.3.0)

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

F500 Elite. FIELDBUS ADAPTER. Watchdog (NTC) Elite to DeviceNet communications. (Software Version 1.1.x)

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Incutrol/2 Regulator

Intrinsically Safe Transmitters, Option Code 2n

MN908 No. 282C Replaces 282B LB7013

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

A10. Installation & Operation Manual. Flow Switch. For the latest version of this manual, visit kteksolidslevel.com.

Controllers. Instruction Manual WARNING

User s Manual and Operating Instructions

Remote Relay Module (RRM)

OPERATION MANUAL. W4005V46-SYSx /B (BÜHLER) INSTALLATION INSTRUCTIONS. Elevator Monitoring System

Master Prep Chopper OWNER S GUIDE QB600W

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Power Conditioners User s Manual. For use with Standard Power Conditioners, Medical Power Conditioners and Ground Guard Power Conditioners

Installation, Operation & Service Manual

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

HotPoly Tote Tank / IBC Heaters (TTH Series)

Original instructions Sense7-series Non-contact coded safety switch

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

(HSTAT Series) Instruction Manual

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Ramsey Motion Monitoring Systems

Instruction Manual WARNING

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Irene-H READ AND SAVE THESE INSTRUCTIONS

MaxLite LED MICRO-T PANEL

Original instructions JSNY7 Magnetic switch

Professional Stackable Chopper

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Radiant Thermostat 519

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Owner s Manual. PIR-1 IR Learner

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

OPERATION & INSTALLATION MANUAL

User s Manual and Operating Instructions

MaxLite LED Round Pendant Highbay Series

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

SEALING FIBER SEALING COMPOUND

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

User s Manual and Operating Instructions

G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

MICRO SWITCH BX/BX2 Series

Global Water Instrumentation, Inc.

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

Thermometer model 02059

Eliza Hugger 56 CEILING FAN

DUST FREE CARBON Whole House Air Purifier

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

PodView Level Indicator LI40 Series Manual

OPERATION MANUAL Part No. s - WDC4V4C, WDC4V46C Hardware Version R4 - Software Version 4.7.X

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

General Purpose Industrial VRS Magnetic Speed Sensors

Ultrasonic Reflective Sensor

High Temperature Industrial VRS Magnetic Speed Sensors

User s Manual and Operating Instructions

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

FLCH4R Garage and Utility Electric Heater

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Master Prep Frozen Treat & Drink Maker

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

Industrial Vacuums, Inc

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

INSTALLATION MANUAL. PP1 Ozone System Designed for use within pool skimmer

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

XT Series Thermostats

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Hazardous Area Ringdown Telephone

2-in-1 Corded Stick Vacuum Cleaner

INSTRUCTION MANUAL HS-229G

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Figure 1. Figure 2. See notes 1 and 2 below.

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

ion Genesis Pump Controller

USER GUIDE. Metal Ceramic Heater NS-HTMCSL6. Before using your new product, please read these instructions to prevent any damage.

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Irene READ AND SAVE THESE INSTRUCTIONS

No Touch Door Release Exit Sensor ACA-NTEB

Transcription:

P8003/P8004 Proxswitch INDUCTIVE PROXIMITY SENSOR C US APPROVED Class II Div. 1 INSTALLATION INSTRUCTIONS OPERATION MANUAL Part No s. P8003V10C, P8004V10C www.go4b.com/usa

TABLE OF CONTENTS CUSTOMER SAFETY RESPONSIBILITIES Page 4-5 PRODUCT OVERVIEW Page 6 SPECIFICATIONS Page 6 DIMENSIONS Page 7 INSTALLATION Page 7-8 STANDARD WIRING DIAGRAM Page 8 TESTING & COMMISSIONING Page 9 TROUBLESHOOTING GUIDE Page 10 PRODUCT WARRANTY Page 11 WARNING Rotating parts can crush, cut and entangle. Do NOT operate with guard removed. Lockout power before removing guard or servicing.

Dear 4B Customer: Congratulations on your purchase. 4B appreciates your business and is pleased you have chosen our products to meet your needs. Please read in its entirety and understand the literature accompanying the product before you place the product into service. Please read the safety precautions carefully before operating the product. With each product you purchase from 4B, there are some basic but important safety considerations you must follow to be sure your purchase is permitted to perform its design function and operate properly and safely, giving you many years of reliable service. Please read and understand the Customer Safety Responsibilities listed below. Failure to follow this safety directive and the Operation Manuals and other material furnished or referenced, may result in serious injury or death. SAFETY NOTICE TO OUR CUSTOMERS A. In order to maximize efficiency and safety, selecting the right equipment for each operation is vital. The proper installation of the equipment, and regular maintenance and inspection is equally important in continuing the proper operation and safety of the product. The proper installation and maintenance of all our products is the responsibility of the user unless you have asked 4B to perform these tasks. B. All installation and wiring must be in accordance with Local and National Electrical Codes and other standards applicable to your industry. (Please see the article Hazard Monitoring Equipment Selection, Installation and Maintenance at www. go4b.com.) The installation of the wiring should be undertaken by an experienced and qualified professional electrician. Failure to correctly wire any product and/or machinery can result in the product or machine failing to operate as intended, and can defeat its design function. C. Periodic inspection by a qualified person will help assure your 4B product is performing properly. 4B recommends a documented inspection at least annually and more frequently under high use conditions. D. Please see the last page of this manual for all warranty information regarding this product. CUSTOMER SAFETY RESPONSIBILITIES 1. READ ALL LITERATURE PROVIDED WITH YOUR PRODUCT Please read all user, instruction and safety manuals to ensure that you understand your product operation and are able to safely and effectively use this product. 2. YOU BEST UNDERSTAND YOUR NEEDS Every customer and operation is unique, and only you best know the specific needs and capabilities of your operation. Please call the 24-hour hotline at 309-698-5611 for assistance with any questions about the performance of products purchased from 4B. 4B is happy to discuss product performance with you at any time. PAGE 4

3. SELECT A QUALIFIED AND COMPETENT INSTALLER Correct installation of the product is important for safety and performance. If you have not asked 4B to perform the installation of the unit on your behalf, it is critical for the safety of your operation and those who may perform work on your operation that you select a qualified and competent electrical installer to undertake the installation. The product must be installed properly to perform its designed functions. The installer should be qualified, trained, and competent to perform the installation in accordance with Local and National Electrical Codes, all relevant OSHA Regulations, as well as any of your own standards and preventive maintenance requirements, and other product installation information supplied with the product. You should be prepared to provide the installer with all necessary installation information to assist in the installation. 4. ESTABLISH AND FOLLOW A REGULAR MAINTENANCE AND INSPECTION SCHEDULE FOR YOUR 4B PRODUCTS You should develop a proper maintenance and inspection program to confirm that your system is in good working order at all times. You will be in the best position to determine the appropriate frequency for inspection. Many different factors known to the user will assist you in deciding the frequency of inspection. These factors may include but are not limited to weather conditions; construction work at the facility; hours of operation; animal or insect infestation; and the real-world experience of knowing how your employees perform their jobs. The personnel or person you select to install, operate, maintain, inspect or perform any work whatsoever, should be trained and qualified to perform these important functions. Complete and accurate records of the maintenance and inspection process should be created and retained by you at all times. 5. RETAIN AND REFER TO THE OPERATION MANUAL FOR 4B S SUGGESTED MAINTENANCE AND INSPECTION RECOMMENDATIONS As all operations are different, please understand that your specific operation may require additional adjustments in the maintenance and inspection process essential to permit the monitoring device to perform its intended function. Retain the Operation Manual and other important maintenance and service documents provided by 4B and have them readily available for people servicing your 4B equipment. Should you have any questions, please call the free 24-hour hotline number (309-698-5611). 6. SERVICE REQUEST If you have questions or comments about the operation of your unit or require the unit to be serviced please contact the 4B location who supplied the product or send your request via fax (309-698-5615) or call us via our 24-hour hotline number in the USA (309-698- 5611). Please have available product part numbers, serial numbers, and approximate date of installation. In order to assist you, after the product has been placed into service, complete the online product registration section which is accessed via our website www. go4b.com/usa. PAGE 5

WARNING Rotating machinery can cause serious injury or death Always lockout and tagout the machine prior to installation PRODUCT OVERVIEW The P800 Proxswitch is an inductive sensor designed to detect shaft speed, shaft position, gate position, or object presence. The P800 is a limit switch style proximity sensor, which works on the damped oscillator principle. No contact is made between the sensor and the object being monitored. Two different Sensor outputs are available. One with the output energized ON (P8003V10C), and another with the output de-energized OFF (P8004V10C) with no target present. Both units are fully encapsulated and come with a 6 foot cable lead and 1/2 inch conduit entry. Two LED s show power supply and input status. SPECIFICATIONS Supply Voltage - Output - Output State - Max. Input Speed - Indication - Operating Temperature - Sensing Range - Enclosure - Conduit Entry - Cable Length - Weight - Protection - Approvals - 12 to 240 VDC / 24 to 240 VAC Fully opto-isolated, high voltage, bilateral FET 120 VAC / VDC 100 ma max. P8003V10C - Output energized (on) with no target (optional) P8004V10C - Output de-energized (off) with no target (standard) 100 Hz (6,000 PPM) Red (input) and green (output) LED s for target detection -13 F (-25 C) to 158 F (70 C) Ferrous target - 1/2 inch (12 mm) maximum Non-ferrous target - 5/16 inch (6 mm) maximum Nylon 1/2 inch NPT 6 ft. (2 m) - 4 core 1 lb. IP67 CSA Class II Div 1 Groups E, F and G (USA and Canada) PAGE 6

ALL DIMENSIONS IN INCHES Sensing Face DIMENSIONS 4-19/32 Top Side 1/2 NPT Conduit Entry 1-9/16 1-3/16 6 ft. Cable 1-9/16 1-5/32 2-3/8 1/4 Dia. INSTALLATION The P800 should be wired as shown in the connections diagram on page 8. The two P800 models have different connections, so make sure to use the correct diagram for your model. Cable length can be extended to virtually any distance required. The proximity sensor is well protected against electrical interference, but if long cable runs are used in very noisy environments, the cabling should be segregated from any high current carrying conductors. The sensing face of the sensor, should overhang at least 1-1/4 inches (31 mm) from any metalwork that the unit is fixed to, otherwise the unit will stay in the ON state. Ensure that any background metalwork, behind the target to be sensed, is at least 5/8 inches (15 mm) behind the target. This will prevent the proximity sensor from detecting that background metalwork. Illustration A below denotes sensing ranges for ferrous and non-ferrous targets. NOTE - Red LED (input) indicates target sensed, and green LED (output) indicates output on. LED s are located on the top side of the P800 (Illustration A). Target 3/4 Dia. (19 mm) 1/2 (12 mm) Max. (Ferrous Target) 5/16 (6 mm) Max. (Non-Ferrous Target) Shaft 5/8 Min. (15 mm) Metalwork (Grey Area) 1/1/4 Min. (31 mm) ILLUSTRATION A - SENSING RANGES Ensure all connections are correct before applying power. Apply power to the P800 and machinery, then check that the input and output LEDs are flashing ON and OFF indicating the target is being sensed. PAGE 7

WARNING O.S.H.A. requires that all exposed rotating shafts are provided with a full guard. Therefore, this device and its target must be equipped with a guard. Fasten the P800 to a suitable mounting bracket, such as 4B s Whirligig universal shaft sensor mount, with the nose of the switch within the sensing range of the target, as shown below - P800 Shown on Optional Whirligig Shaft Sensor Mount with Mag-Con Magnetic Connector STANDARD WIRING DIAGRAM All wiring must be In accordance with local and national electrical codes and should be undertaken by an experienced and qualified electrician. Always use dust/liquid tight flexible metal conduit with approved fittings to protect the sensor cables. Use rigid metal conduit to protect the cables from the sensors to the control unit. Conduit systems can channel water due to ingress and condensation directly to sensors and sensor connections which over time will adversely affect the performance of the system. As such, the installation of low point conduit drains is recommended for all sensors. L (+) Supply 12-240 VDC 24-240 VAC L (+) N (-) Brown Blue Black White Maximum Signal 120 VAC/VDC 100 ma Max. Load N (-) P8003V10C - Output state is energized ON with no target present. P8004V10C - Output state is de-energized OFF with no target present. - Sensor supply and load supply can be different values, and have different ratings. NOTE Signal polarity is not important and the load may be connected to either lead. PAGE 8

TESTING AND COMMISSIONING 1. Check that the unit is correctly installed (see standard wiring diagram). 2. Check that the distance between the target, stud or bolt head and sensing face of P800 is within the minimum distance specified. 3. Start up machine. 4. If monitoring for speed see A, for proximity monitoring see B - A. If the P800 is being used to monitor speed, 4B s SpeedMaster calibration and testing device can be used to insure the P800 shuts down the machine at the correct percentage of slip. Shut down will depend on your specific monitoring setup. 4B recommends an instant shutdown on any belts slipping 20% or more of normal speed. B. If the P800 is being used as a proximity switch, be sure that the target is not within range of the sensor prior to testing. Use a metal putty knife or a small piece of metal and place it between the sensing face of the P800 and the target. This will cause the sensor to energize the output, and both the green and red LEDs will go on. Removing the putty knife will de-energize the output signal and both LEDs will go off. Patents - US8947073 MX321802 EP26223568 SPEEDMASTER The SpeedMaster with Pulse Pilot is the only device that accurately tests the calibration of a speed switch, and allows testing of the alarm and shutdown features of the sensor while installed on the machine shaft. The SpeedMaster operates in two modes. Input mode is used to measure the pulse rate at normal speed. Output mode will allow the user to input pulses to the sensor for testing purposes. The Pulse Pilot fits between the gap between the sensor and the target. The Pulse Pilot will have no effect on the operation of the speed switch until it is connected to the SpeedMaster and set to output mode. WARNING If the system does not immediately shutdown as expected or alarm as required, then remove the machine from service until the problem has been diagnosed and corrected. PAGE 9

TROUBLESHOOTING GUIDE FAULT REMEDY Check that the sensing face of the sensor is not bolted directly to metalwork Input and Output LED s Stay ON Check that there is a space between the sensor face and any surrounding metalwork (1-1/4 inches - 31 mm minimum) Check that the machinery is rotating and that the target is actually leaving the sensor before reappearing Check that background metalwork, behind target, is far enough away so as not to be detected Check supply voltage to the sensor. Input and Output LED s Stay OFF Check that target is within specified operating range of unit. Check that machinery is rotating and that target is passing the sensing face of the sensor. PAGE 10

1. EXCLUSIVE WRITTEN LIMITED WARRANTY ALL PRODUCTS SOLD ARE WARRANTED BY THE COMPANY (4B COMPONENTS LIMITED, (4B) BRAIME ELEVATOR COMPONENTS LIMITED, AND (4B) S.E.T.E.M. Sarl HEREIN AFTER REFERRED TO AS 4B TO THE ORIGINAL PURCHASER AGAINST DEFECTS IN WORKMANSHIP OR MATERIALS UNDER NORMAL USE FOR ONE (1) YEAR AFTER DATE OF PURCHASE FROM 4B. ANY PRODUCT DETERMINED BY 4B AT ITS SOLE DISCRETION TO BE DEFECTIVE IN MATERIAL OR WORKMANSHIP AND RETURNED TO A 4B BRANCH OR AUTHORIZED SERVICE LOCATION, AS 4B DESIGNATES, SHIPPING COSTS PREPAID, WILL BE, AS THE EXCLUSIVE REMEDY, REPAIRED OR REPLACED AT 4B S OPTION. 2. DISCLAIMER OF IMPLIED WARRANTY NO WARRANTY OR AFFIRMATION OF FACT, EXPRESSED OR IMPLIED, OTHER THAN AS SET FORTH IN THE EXCLUSIVE WRITTEN LIMITED WARRANTY STATEMENT ABOVE IS MADE OR AUTHORIZED BY 4B. 4B SPECIFICALLY DISCLAIMS ANY LIABILITY FOR PRODUCT DEFECT CLAIMS THAT ARE DUE TO PRODUCT MISUSE, ABUSE OR MISAPPLICATIONS, AS AUTHORIZED BY LAW, 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE. 3. NO WARRANTY BY SAMPLE OR EXAMPLE ALTHOUGH 4B HAS USED REASONABLE EFFORTS TO ACCURATELY ILLUSTRATE AND DESCRIBE THE PRODUCTS IN ITS CATALOGS, LITERATURE, AND WEBSITES, SUCH ILLUSTRATIONS AND DESCRIPTIONS ARE FOR THE SOLE PURPOSE OF PRODUCT IDENTIFICATION AND DO NOT EXPRESS OR IMPLY A WARRANTY AFFIRMATION OF FACT, OF ANY KIND OR A WARRANTY OR AFFIRMATION OF FACT THAT THE PRODUCTS WILL CONFORM TO THEIR RESPECTIVE ILLUSTRATIONS OR DESCRIPTIONS. 4B EXPRESSLY DISCLAIMS ANY WARRANTY OR AFFIRMATION OF FACT, EXPRESSED OR IMPLIED, OTHER THAN AS SET FORTH IN THE EXCLUSIVE WRITTEN LIMITED WARRANTY STATEMENT ABOVE, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 4. LIMITATION OF DAMAGES PRODUCT WARRANTY ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL, EXEMPLARY, OR PUNITIVE DAMAGES, OR FOR LOSS OF PROFIT WHETHER DIRECT OR INDIRECT, IS EXPRESSLY DISCLAIMED. PAGE 11

With subsidiaries in North America, Europe, Asia, Africa and Australia along with a worldwide network of distributors, 4B can provide practical solutions for all your applications no matter the location. 4B BRAIME ELEVATOR COMPONENTS Hunslet Road Leeds LS10 1JZ United Kingdom Tel: +44 (0) 113 246 1800 Fax: +44 (0) 113 243 5021 4B DEUTSCHLAND 9 Route de Corbie Lamotte Warfusée F-80800 France Tel: +49 (0) 700 2242 4091 Fax: +49 (0) 700 2242 3733 4B ASIA PACIFIC Build No. 899/1 Moo 20 Soi Chongsiri, Bangplee-Tam Ru Road, Tanbon Bangpleeyai, Amphur Bangplee, Samutprakarn 10540 Thailand Tel: +66 (0) 2 173-4339 Fax: +66 (0) 2 173-4338 4B COMPONENTS LTD. 625 Erie Avenue Morton, IL 61550 USA Tel: 309-698-5611 Fax: 309-698-5615 4B SETEM SARL 9 Route de Corbie 80800 Lamotte Warfusée France Tel: +33 (0) 3 22 42 32 26 Fax: +33 (0) 3 22 42 37 33 4B AFRICA 14 Newport Business Park Mica Drive, Kya Sand 2163 Johannesburg South Africa Tel: +27 (0) 11 708 6114 Fax: +27 (0) 11 708 1654 4B AUSTRALIA Unit 1/18 Overlord Place Acacia Ridge Queensland 4110 Australia Tel: +61 (0) 7 3711 2565 Fax: +61 (0) 7 3711 2574 www.go4b.com Copyright 2015 4B Group - All Rights Reserved REV121715