Flammable Safety cabinets for toxics and Multirisk safety cabinets

Similar documents
SAFETY CABINETS FOR CORROSIVES

Flammable. cabinets. Corrosive. cabinets. Toxic cabinets. and multirisk. Pesticide range. Fume hoods, filtering. cabinets - Ventilation

EN Storage of gas cylinder

Flammables Safety Cabinets

STORAGE ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS...

We are your partner for security and environment protection

Safety Cabinets / Width 1200 mm / 2 Doors. Height 1968 and 1298 mm Height 1968 mm Height 1968 mm. Folding door. Type 90. Type 30

4 Storage cabinets SCALA

Explosion-Proof Waste Chemical Storage Cabinets

Sovella wall shelving. Sovella wall shelving. Oval horizontal rail

Metal shelving Meccanocar line "Taurus" Base Module. Workshop furniture

Well. informed! Edition compact 3 Professional Storage of Hazardous Materials. Technical Highlights Facts and Consequences

FIRE MY11 - FIRE RADIO MY11 SAFETY CABINETS CERTIFIED FOR THE STORAGE OF FLAMMABLE AND RADIOACTIVE PRODUCTS

UTILITIES SICUR WOOD 61 SICUR 63 SICUR KEM 64 SICUR SHELF 65 PHYTOSAFETY 66 DRUM STORAGE SUMPS 67 ABSORBENT PADS 68 EMERGENCY EYE AND BODY SHOWER 69

2. Occupational safety/security Furniture/Stairs-Fume hoods

L a b o r a t o r y E q u i p m e n t C a t a l o g

CABINETS AGF BROME KNOWS YOUR CHALLENGES!

MODULAR BEST Products and services presentation January 2012

Steel Casework Acid Storage

19 Cabinets. Eurolan. 19" Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets

Phenomena up close. Demonstration fume cupboards. Special features

Smart Compact mobile "L" Cabinet

COOL line Safety storage cabinets in modern design. Type 90. Fire-proof refrigerators for maximum fire protection

Lista Premium 75/200 Drawer cabinets, workbenches and partition material

Smart Compact Mobile "L" Cabinet

TOOL STORAGE CONTACT US +44 (0) Fax: +44 (0) Serenco UK Full Product Catalogue

Model :- MGMT-TB3C. Model :- MGMT-TB5C

V-LINE The new formula for the storage of hazardous materials

Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

Technical Catalogue laboratory furniture system

HOME OFFICE WALL UNITS

Safe and cooled storage of flammable hazardous materials

Technical Catalogue laboratory furniture system

5 Supply and disposal

Q u iet Q u i c k P a y l o ad T o u g h

Biological Incubators Biotech Ovens

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

TRIO Compact Gas Barbecue

Internal Storage of hazardous Materials P P

3 WO OPEN WALLCABINET, TWO ADJUSTIBLE SHELVES 1 W OPEN WALLCABINET, TWO ADJUSTIBLE SHELVES

>>> FIRE MY11 >>> ACCORDING TO VERSIONS NEW SAFETY CABINETS CERTIFIED TYPE 90 FOR THE STORAGE OF FLAMMABLE PRODUCTS

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Safety and environmental protection. Safe flammable storage aboard cruise ships

Laboratory Furniture System DELTA 30

Saveer Europe Laboratory Furniture

Basic suction pump - Technical Information

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

CLASSIC line Safety storage cabinets in modern design. Type 90. Safety storage cabinets with wing door technology

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

Dimplex ebrochure PDF

Pharmette Medicine Centers

CP+ Gas & Oil Cabinet Heater Range

GUIDE SPECIFICATIONS AQUARIUS ii

TOOL STORAGE THE PROFESSIONAL'S CHOICE.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Drawers BUYERS GUIDE 2013/14

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Laboratory Refrigerators and Freezers

Tool and Parts Drawers

2.2. Type 90. Safety cabinets for active storage of drums

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

ecostore 1 Door Digital Stainless Steel Freezer, 670lt (-22/-15) ecostore

GO Office Limited STEEL STORAGE CATALOGUE

METAL PEDESTALS. By Actiu.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

For perfect office organisation.

Technical Ventilation

Wiring Duct Product Selection Guide

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Variety of drawer accessories available: full-depth partitions, dividers, plastic bins, hanging file holders, foam for protection, etc.

Treston ESD Storage Systems Picking Bins. Stacking Bins

Packing volume (cbm) G.W (kgs) Item No Picture Description Size(mm) Remark. 0.7mm after coating. HY-D001 two drawers cabinet/kd W400*D490*H510 0.

incubator, the best in its class

HIGH DENSITY TOOL & PARTS STORAGE

English. Medication, Plasma, Blood, Lab Supplies Organisation in the Refrigerator FRIDGES KS-E01

Variety of drawer accessories available: full-depth partitions, dividers, plastic bins, hanging file holders, foam for protection, etc.

Safety In Chemistry. Identified Risks and Hazards

SELF 800 THE CHOICE. When capacity matters

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

TOOL STORAGE THE PROFESSIONAL'S CHOICE.

Loadstar AC/DC Systems

FUNCTIONAL STORAGE SOLUTIONS KITCHEN WARDROBE BATH

Division 12 Furnishings

PR / MP I Laboratory / Medicine

Technical Catalog laboratory furniture system

Stainless Steel Healthcare Equipment

FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT

Stainless Steel Sanitary Ware

Chemical Systems Control

World class DG storage for Australasian labs

Workbenches Tool carts Metal lockers.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Gram Commercial Technical information

Condensate water pumps

DANSANI MIDO NEW TERRA GREY. Dansani.co.uk

Transcription:

Safety for toics and Multirisk safety Introduction Due to obvious reasons of safety (fire, eplosion, corrosion, intoication) dangerous chemicals, whatever they may be must be handled and stored etremely carefully. This catalogue will help you to find solutions in connection with the storage of your dangerous chemicals according to your safety requirements. Do not hesitate to contact us for fast and personalized advices. CERTIFICATIN The homologated laboratory MPA Dresden (GER) has controlled and certified GS our safety (Range 6 page, Range page, Range 8 page 5 and Range.A page 8,. The GS certification guarantees the quality and the very good level of security of our products (respecting our manufacturer recommendations). NRMALIZATIN Public health (relates to toics) Toics and poisonous chemicals must be stored in a specific place equipped with key closing. Recommendation (relates to different families of chemicals) Non compatible chemicals must be stored in separate or compartments. Environment (relates to pollutants) Each chemical liable to pollute water or soil must be stored with a retention tank. European norm EN 70 (relates to flammables in laboratories) s kept inside laboratories must be stored into one or more safety with a minimum fire resistance of 5 minutes. classifications: 5, 0, and 90 minutes. EN 70 Choose your safety cabinet according to your storage and chemicals incompatibilities. Simplified diagram of the incompatibilities between hazardous chemicals Antifire equipments and Files Chemicals to be stored. Xn Xn Xi Xn Xi Adapted cabinet onecompartment Range 6 (page ) Range (page ) Adapted cabinet multicompartments. Range.B / Range 8 Range.D Range.E Range Range.C Range.A Range 7.90 (page 6) (page ) (page 9) (page 0 & (page 8) (page 7) (page 5) ) Xn Xi Xi Compatible products Do not store, handle or waste together ecept if particular conditions are applied. Non compatible products. For the storage of very corrosive chemicals (Hydrochloric acid, Nitric acid, Sulfuric acid), we recommend our.b or 8.A. For more information, please refer to our catalogue concerning for corrosives. The manufacturer keeps the right to modify the technical characteristics without notice. Edition 0/009. and Toic Whether you are working in a workshop, laboratory, warehouse, manufacturing unit, department of a company, if you store hazardous chemicals such as poisons, flammables, corrosives, polluting, harmful products, etc, you must store them cautionsly safety.

EN IS 8 C Range 6 (w ) AB RPV In compliance with EN IS 8 (SV50 model). Large warning labels in compliance with IS 86, 9/58/CEE European directive and norm NF X08.00. Fan: 0 marking. Tested en approved GS by MPA DRESDEN laboratory. High and low vents Ø 00 mm. Selfclosing system of the door (ecept u SV50 model). Doors with keylock system. Adjustable feet (ecept u SV50 model). Built in steel 5/0th (ecept u SV50 model: built in steel /0th 0 mm mineral fiber insulation). Double wall door in steel 5/0th (ecept u SV50 model: double wall doors in steel /0th 0 mm mineral fiber insulation). Epoy paint : Yellow RAL 0 (v flammable products); Blue RAL 505 (w corrosive products); White RAL 900 (u solvent, base products and y toic products). Large warning labels. Adjustable steel retention shelf (w corrosive models equiped with retention tray in PVC). Removable steel retention tank (00 mm high) at the bottom of the cabinet (for "" model w, tank made in PVC). Reference u SV50 (flammables) SECURITE WARNING! The AC0 model should not be used with highcorrosive products (sulfuric acid, nitric acid, phenol, hydrocloric acid) and requires an ehausting system to improve the life cycle. For highcorrosive products storage please refer to our 8A (ref. APC0). For flammable products storage in laboratories refer to our brochure EN70 Safety. Eternal dim. Internal dim. H W D (mm) H W D (mm) 750** 000 50 **without feet: height 670mm Storage Number of Weight capacity (L) capacity (L) shelves 650 950 00 50 6 For SV50 model, selfclosing system of the doors firebreak valve for air outlet. v SV0 (flammables) 670 0 500 650 50 70 0 8 0 w AC0 (acids) 670 0 500 650 50 70 0 8 0 BA0 (bases) 670 0 500 650 50 70 0 8 0 y T0 (toics) 670 0 500 650 50 70 0 8 0 w AB (acids bases) 670 00 500 () 650 50 70 56 wv AS (acids flammables) 670 00 500 () 650 50 70 56 v BS (bases flammables) 670 00 500 () 650 50 70 56 wv AT (acids toics) 670 00 500 () 650 50 70 56 y BT (bases toics) 670 00 500 () 650 50 70 56 vy ST (flammables toics) 670 00 500 () 650 50 70 56 wv ABS90 (acids bases flammables) 670 650 500 () 650 50 70 90 8 90 670 00 500 () 650 50 70 0 0 wvy ABST0 (acids bases flammables toics) and All (ecept SV50 model): swivel castors ( with locking) ref. RVP. Electric fan IP ; 0 v; CEI 6.8 agreements; 90 m/h for w "Acids", "Base" and y "Toic" models. (ref. M00/). Power regulation bo for fan (ref. BCDE). SV50 model only: SECURITY kit (selfclosing system of the doors firebreak valve for air outlet) in option. The manufacturer keeps the right to modify the technical characteristics without notice. Edition 0/009. ne cabinet for each type of chemical used. Possibility of connection between models (eample: toic corrosive, see table) ecept for SV50 model. Especially designed to settle under the bench. RPV swivel castors ( with locking); height with castors: 70 mm. M00/ Singlephase fan (90 m/h 0 volts) for w, or y models. BCDE Power regulation bo for fan ref : M00/ and cans Antifire equipments and Files v SV0 RPV u SV50 Toic UNDERBENCH SAFETY CABINETS

RANGE AS ASDD and ASDD AS In compliance with the articles R566 and R568 of health regulation. In compliance with recommendations of The National Institute of Research and Safety at work. Large warning labels in compliance with IS 86, 9/58/CEE European directive and NF X08.00 norm. Tested and approved GS by MPA DRESDEN laboratory. High and low vents: double grating air inlets in the bottom of the doors. top air outlet Ø 00 mm with grating. Handling doors with keylocking system. Additional shelf. shelf and tank in PVC for corrosive products. Industrial absorbent mat for retention tank (Ref. JF0D). Inepensive solution for your dangerous products storage. Available in versions : "", "" or "Toic" products. Built in steel 0/0th. White epoy paint RAL 900. "", "", "Toic" or "Harmful" large warning labels. adjustable retention shelves. Removable retention tank at the bottom (00 mm height). To protect the users health and to improve the life cycle and the safety of your cabinet we recommend to install an ehausting system. Please contact us for more information. Antifire equipments and Files WARNING! For safety reasons, do not store different product families together in the same compartment. Do not store highcorrosive products like sulfuric acid, nitric acid, hydrochloric acid... Reference AS ASDD AS ASDD AS ASDD Internal dim. H W D (mm) Storage capacity (l) capacity (l) Number of shelves W. Single door cabinet for flammable products 0 5 500 7 50 50 6 Double doors cabinet for flammable products 0 0 500 7 00 00 9 Single door cabinet for corrosive products 0 5 500 7 50 50 6 Double doors cabinet for corrosive products 0 0 500 7 00 00 9 Single door cabinet for toic products 0 5 500 7 50 50 6 Double doors cabinet for toic products 0 0 500 7 00 00 9 AS Single door cabinet for irritating/harmful products 0 5 500 7 50 50 6 ASDD Double doors cabinet for irritating/harmful products 0 0 500 7 00 00 9 EE Eternal dim. H W D (mm) Desciption 0 50 70 5 ESASDD Additional shelf for double doors cabinet Additional shelf for single door cabinet 0 0 70 0 8 SEPVC SBPVC 0 50 00 50 5 shelf in PVC* base trough in PVC* *CAUTIN! For double doors models pieces by level are required. The manufacturer keeps the right to modify technical characteristics without notice. Edition 0/009. Toic SECURE CABINETS FR DANGERUS PRDUCTS

RANGE 8 SAFETY CABINETS WITH GLAZED DRS FR TXIC AND NXIUS PRDUCTS Toic In compliance with articles R566 and R5866 of the health regulation. Large warning labels in compliance with IS 86, 9/58/CEE European directive and NF X08.00 norm. Tested and approved GS by MPA DRESDEN laboratory. Economic solution for dangerous products storage. Easy sight of the stored products thanks to glazed doors. Available in versions, for toic products or for noious products. Additional shelf. WARNING! For safety reasons (chemical reactions between incompatible products) the different product families must be stored separately. Eternal dim. H W D (mm) AJ ne door cabinet for toic products 975 50 00 AJD Two doors cabinet for toic products 975 000 00 AJ ne door cabinet for noious/irritant products 975 50 00 AJD Two doors cabinet for noious/irritant products 975 000 00 ESAJ Additional shelf for one door cabinet 5 50 50 ESAJD Additional shelf for two doors cabinet 5 9 50 Ref. AJ option ESAJ To protect the users health and to improve the life cycle and the safety of your cabinet we recommend to install an ehausting system. Please contact us for more information. Internal dim. Storage Number of W. H W D (mm) capacity (L) capacity (L) shelves 90 50 50 9 75 90 9 00 7 5 90 50 50 9 75 90 9 00 7 5 8 5 Antifire equipments and Files AJD High opening vent Ø 00 mm with connecting piece for possible ehaust. mm thick glazed door(s). Handling door(s) with keylocking system. The manufacturer keeps the right to modify technical characteristics without notice. Edition 0/009. and Built in steel 0/0th. White epoy paint RAL 900. "Toic" or "Noious" large warning labels. adjustable shelves in height. removable retention base trough at the bottom ( mm high).

RANGE.C AS In compliance with the health regulation articles (R566 & R568). Large warning labels in compliance with IS 86, NF X08.00 norm and the European directive 9/58/CEE. High and low vents Ø 00mm outlet for possible eternal connection. Handling door(s) with key locking. and Possibility to separate the dangerous product families ( in compliance with the National Institute of Research and Safety at work. Modulable solution for the storage of your chemicals. Internal equipments of the different compartments following your needs. Possibility to join the different models together. th APCA APCA APCA Built in steel 0/0. White epoy paint RAL 900. Toic,, Harmful or Acid large warning label following your needs Steel retention shelves adjustable in height. ne removable base trough in steel in the bottom of each compartment. PVC equipment for acid compartment including PVC protection shelves and PVC retention tank. Additional shelf in steel. Industrial absorbent mat (Ref JP 0). To protect the users health and to improve the life cycle and the safety of your cabinet we recommend to install an ehausting system. Please contact us for more information. Antifire equipments and Files EURPEAN MANUFACTURE Reference Dimensions H W D (mm) Compartments capacity Storage (l) (l) N of Shelves W. AS compartment cabinet 85 5 500 50 AP compartments cabinet 85 5 500 0 ( ) 7 ( 7) ( ) 65 AP compartments cabinet 85 5 500 ptions for acids compartments 90 ( 0) 96 ( ) ( ) 70 CAPP PVC protection shelves and PVC retention tank for AS,5 CAPP CAPP PVC protection shelves and PVC retention tank for AP PVC protection shelf and PVC retention tank for AP,5 APCA compartments cabinet with one acid equipped compartment ref CAPP 85 5 500 0 ( ) 7 ( 7) ( ) APCA compartments cabinet with one acid equipped compartment ref CAPP 85 5 500 90 ( 0) 96 ( ) ( ) 7 APCA compartments cabinet ( AP) with one acid equipped compartment ref CAPP 85 0 500 0 ( ) 8 ( 7) 8 ( ) APCA 6 compartments cabinet ( AP) with one acid equipped compartment ref CAPP 85 0 500 (6 0) 9 (6 ) 6 (6 ) Eemples for equipped and/or assemblied 6 6 The manufacturer keeps the right to modify technical characteristics without notice. Edition 0/009. Toic MDULABLE CMPARTMENTS CABINETS

RANGE.D Toic MULTIRISK MDULAR CMPARTMENTS CABINETS Strong rubber wheels insure steadiness Possibility to segregate the dangerous product families (in compliance with the National Institute of Research and Safety at work). Modular solution for the storage of your chemicals. Individual equipments of the different compartments following your needs. Possibility to join the different modules together. Supplied with Toic,, Harmful or Acid large warning labels following your needs (to stick on according to your storage). ne large Sliding drawer per module allowing easy access of the products from both sides and insuring visibility. Strong rubber wheels easing the opening of the door while insuring the steadiness of the cabinet. Additional steel retention shelves (ref. EST). Protection shelves in PVC (ref. ESPT). PVC equipment for acid compartment including PVC protection shelves and PVC retention tank (ref. CAPT). Industrial absorbent mat (ref. JP 0). Built in steel 0/0th. White epoy paint RAL 900. Steel retention shelves (height: 50 mm) adjustable in height. Reference EURPEAN MANUFACTURE To protect the users health and to improve the life cycle and the safety of your cabinet we recommend to install an ehausting system. Please contact us for more information. Dimensions H W D (mm) Compartments capacity Storage (bottles) (l) N of shelves W. AT ne module cabinet 85 5 500 8,5L 0 AT Two modules cabinet 85 0 500 98 ( 8),5 L ( 0) 8 ( ) AT AT Three modules cabinet 85 6 500 ( 8),5 L 0 ( 0) ( ) 0 Four modules cabinet 85 0 500 9 ( 8),5 L ( 0) 6 ( ) 0 EST Additional steel retention shelves ESPT CAPT Protection shelf in PVC PVC protection shelves and PVC retention tank for the corrosive module 8 50 5 5 50 0 0,5 L,5 L 0 0 () 50 0 0 8 ( ),5L 0 ( 0) 7 The manufacturer keeps the right to modify technical characteristics without notice. Edition 0/009. High and low vents 0 00mm outlet for possible eternal connection. Handling door(s) with key locking. Per module : one large Sliding drawer on rails. Antifire equipments and Files In compliance with the health regulation articles (R566 & R568) and with the recommendations of the National Institute of Research and Safety at work. Large warning labels in compliance with IS 86, NF X08.00 norm and the European directive 9/58/CEE. and AT

CMPARTMENTS SAFETY CABINETS Toic C RANGE.A AB SV90 SV50 In compliance with the health regulation articles (R566 & R568). Large warning labels in compliance with IS 86, NF X08.00 norms and 9/58/CEE European directive. Fan with 0 marking. Tested and certified GS by MPA DRESDEN laboratory. White epoy paint RAL 900. "Toic", "", "Bases" or "Acids" large warning labels. Steel retention shelves adjustable in height. shelf in PVC for "Acid" compartment. removable base trough in steel for bases compartment (ecept "Acids" compartment: base trough in PVC). Possibility to separate the dangerous products families in compliance with The National Institute of research and Safety at work (INRS). High and low vents Ø 00 mm outlet (for possible eternal conneion). Handling doors with keylocking system. 0V50Hz electric fan (AB and AB75 models). Built in steel 5/0th. Double wall door in steel 5/0th. Additional shelf. Industrial absorbent mat (ref. JF0D). Ref. AB Dimensions H W D (mm) Et. 0 5 5 Int. () 890 50 70 High cabinet with fan AB75SC High cabinet without fan (l) High cabinet without fan ( 0) 0 ( ) 56 (8) 70 (5) Et. 5 5 Int. () 890 50 70 AS75SC High cabinet without fan SV90 Storage (l) Compartment type Number of shelves Underbench cabinet with fan Et. 670 00 500 ABSC Underbench cabinet without fan Int. () 650 50 70 ASSC Underbench cabinet without fan AB75 Compartment capacity Et. 995 0 5 Int. () 50 90 ( 0) 8 (8) W. Fan 85m/h 0 m/h 75 68 90 ESV90 Additional shelf for SV90 model EPSV90 Additional shelf in PCV for SV90 model CASV90 Additional "Acid" compartment equipment SV50 High cabinet without fan Et. 0 5 Int. () 890 50 70 0 ( ) 0 (5) 8 50 ESV50 Additional shelf for SV50 model EPSV50 Additional shelf in PCV for SV50 model CASV50 Additional "Acid" compartment equipment 8 Compartments customization N REQUEST. The manufacturer keeps the right to modify technical characteristics without notice. Edition 0/008. Antifire equipments and Files and AB75

RANGE C VENTILATED SAFETY CABINETS FR REAGENTS AND TXIC PRDUCTS In compliance with the health regulation articles (566 & R568). Large warning labels in compliance with IS 86, 9/58/CEE European directive and NF X08.00 norm. Fan in compliance with EN 5 5 (part ), EN 6859, CE 075/986, 0 marking standards. Integrated electric fan. Large storage capacity. Built in steel 0/0th. White epoy paint RAL 900. "Toic" and "Noious" large warning labels (to specify with your order). retention shelves adjustable in height with rack system. Removable retention tank at the bottom of cabinet (00 mm height). Integrated electric fan: 0 volts 0, A 8 W; flow 90 m/h; IPX protection; sound level 7,5 Lp db(a) (m). Double handling doors with points keylocking system. Toic Additional shelf. Additional retention shelf in PCV. Sliding drawer. "Poison" chests (see below). MF model with MF poison chest option. and "PISN" CHESTS Can be used as wall mounted to store dangerous products or as poison chest in your safety cabinet ref MF. Built in steel 0/0th. White epoy paint RAL 900. "Toic" warning label in compliance with IS 86, 9/58/CEE European directive and NF X08.00 norm. Shelves adjustable in height: units for the model MF and for the model MF. Handling door with keylocking system. Possibility to fi on the wall. Possibility to connect models. Ref. Eternal dim. Internal dim. Storage Number of W. H W D (mm) H W D (mm) capacity (L) capacity (L) shelves MF Poison chest L 70 05 70 70 0 MF Poison chest 9 L 5 70 05 570 70 9 5 MF Cabinet with ventilation 975 000 500 90 9 50 00 MFSV Cabinet without ventilation 975 000 500 90 9 50 00 ESMF Additional shelf 6 SPMF Additional shelf in PVC 5 TCMF Sliding drawer 0 MF MF 9 The manufacturer keeps the right to modify technical characteristics without notice. Edition 0/009. Antifire equipments and Files Showers and firstaid equipments

RANGE.B EN 70 C MULTIRISK CABINETS EN 70 TYPE 90,, 0 or 5 MINUTES Toic "" compartment tested and approved according to EN 70 (0/00) norm. Large warning labels in compliance with IS 86, 9/58/CEE European directive, EN 70 (0/00), and NF X08.00 norm. Allows segregated storage per product famillies. Fire resistance tested and approved by an independent European laboratory. "" compartments built in Cellular PVC, offering high chemical corrosion resistance. SPECIFICATINS "Toic" compartment : Built in white Cellular PVC. "Toic" large warning label. High and low vent. Handling glazed door with keylocking system. retention sliding drawer. 0 Fire resistance (minutes) MR9 MR6 MR MR E79 C79 E8A 90 0 5 Eternals dim. H W D (mm) 950 70 65 0 90 0 90 00 8 57 8 "Acid" compartment : Built in white Cellular PVC. "Acid" large warning label. High and low vent. Handling glazed door with keylocking. retention sliding drawers. Each compartment is divided in major and one (or two) secondary compartment (H 0 W 0 D 50 mm). The second one may be used for empty bottles storage. See table. "Bases" compartment : Built in white Cellular PVC. "Bases" large warning label. High and low vent. Handling glazed door with keylocking system. retention sliding drawer. Ref. MR9 Additional shelves (ref.: E8A and E79). Perforated cover plate (ref.: C79). W. 95 90 85 6 Major compartments details Number of Internals dim. Storage Number of retention secondary H W D (mm) capacity capacity (L) shelves/tanks compartment 90 0 05 L 8 Acids 870 67 50 0 Kg Bases 0 67 50 Kg Toic 0 67 50 Kg Additional shelf for "flammable" compartement Perforated cover plate to put in retention tank for "flammable" compartment Additional sliding drawer for major "Acid"/"Base"/"Toic" compartements 0 The manufacturer keeps the right to modify technical characteristics without notice. Edition 0/008. EN 770 "" compartment: Double wall construction: outer housing made of sheet steel; inner body made of H.P.L (High pressure laminated) coated sheet. Thermal insulation panel between the walls avoiding thermal bridges. White epoy paint RAL 900. "" and "No open flame" large warning labels. Static ground connection. pening vents with outlet Ø 00 mm for possible eternal conneion. In case of fire a thermofuse automatically seals off the ventilation system. Thermoepanding seals off the door allow keeping the internal body fireproof. Selflocking door with cylinder lock. Keylocking system. Possibility to keep the door open. If the temperature rises to 50 C, a fuse link closes the door automatically. adjustable retention shelves. Removable retention tank on the bottom. Antifire equipments and Files and Storage in separate compartments with ventilation (Ø00) centralized on the cabinet roof (for possible connection).

RANGE 7.90 EN 70 MULTIRISK CABINETS 05 min NRMS AND REGULATINS Toics Tested and approved according to EN 70 (0/00) and EN 6 (06/000). Normalized labelling according to IS 86, 9/58/CEE Directive and EN 70 (0/00). In compliance with the health regulation articles (R566 & R568) for the multirisk. Fire resistance during 90 minutes (approved Type 90) in accordance with IS 8 fire heating curve. Tested and approved by an independent European laboratory. Possibility to separate the dangerous products families in compliance with The National Institute of Research and Safety at work (I.N.R.S.). TECHNICAL DATA Pease, check the EN 70 flammable compartment capter page 0. Pease, check our brochure EN 70 Safety for flammable and eplosive products. 79M 79M 79M 79M 79M 79M 795M p 79M p 79M Underbench cabinet, two doors, with compartments Working cover cabinet, two doors, compartments Working cover cabinet, two doors, compartments Tall cabinet, one door, with compartments Tall cabinet, one door, with compartments Tall cabinet, one door, with compartments Tall cabinet, two doors, with compartments 795M Tall cabinet, two doors, with compartments 795M Tall cabinet, two doors, with compartments 795M Tall cabinet, two doors, with compartments p 795M p 79M Compartment type and storage capacity (L)* p 795M p 795M p 795M Delivered with Eternal Dim. HWD Base Peforated (mm) shelves trough cover plate Weight 8 0 0 8 8 0 0 8 0 670 5 65 0 5 65 0 5 65 8 65 65 8 65 65 8 65 65 8 5 65 6 option option option 8 7 6 8 5 6 0 0 8 8 8 8 5 65 8 5 65 8 5 65 5 6 option 76 78 88 N.B.: In compliance with the EN 70 norm and for the etraction of toic vapours generated inside your cabinet, an ehausting system is required. In all cases, before to store chemical products in multirisk, each user must to contact his safety manager and his chemical products supplier. Please, check our documentation about ehausting systems. Antifire equipments and Files Ref. p 79M p 79M The manufacturer keeps the right to modify technical characteristics without notice. Edition 0/009. 79M and p 795M E79

S SECURE CABINETS FR DANGERUS PRDUCTS RANGE.E AZ00 In compliance with the health regulation articles (R566 & R568) and with the recommendations of the National Institute of Research and Safety at work. Large warning labels in compliance with IS 86, NF X08.00 norm and the European directive 9/58/CEE. Tested and certified GS. Epoy paint : Body: grey (RAL 705). Door(s): yellow (RAL 0)., and Toic large warning labels. shelves/base through (50 mm height). Maimum load by shelf : kg. shelves adjustable in height. Especialy designed for dangerous products storage in compliance with the regulation. Inepensive solution for your dangerous products storage. Delivered with large warning labels :, () and Toic. Working cover cabinet (Ref. : AZ50 et AZ0) are delivered with one rubber cabinettop work tray. Hight and low vents. Handling door(s) with 0 opening angle. Door(s) with key lock. Built in steel. Eternal dim. H W D (mm) AZ50 Working cover cabinet with door 000 500 500 AZ0 Working cover cabinet with doors 000 90 500 AZ50 Tall cabinet with door 950 500 500 AZ00 Tall cabinet with doors 950 90 500 ESE50 Shelf/Base through for AZ50/AZ50 50 88 CE50 Perforated cover plate for ESE50 50 8 8 ESE00 Shelf/Base through for AZ0/AZ00 50 98 CE00 Perforated cover plate for ESE00 50 9 8 Ref. Additional retention shelves/base through (ref. : ESE50 and ESE00). Galvanized perforated cover plate for retention shelves/base through (ref. : CE50 and CE00). Industrial absorbing mat (ref. : JF0D). Number of W. Internal dim. Storage H W D (mm) capacity (L) capacity (L) shelves/tank 890 98 5 0 6 890 98 5 0 98 5 0 50 98 5 00 90 0 6 5 0 0 The manufacturer keeps the right to modify technical characteristics without notice. Edition 0/009. AZ0 AZ50 Antifire equipments and shelvings Ehausting systems Toic AZ50