Sola Hydronic Control. An Eco-Friendly Solution.

Similar documents
7800 SERIES RM7888A Relay Module

7800 SERIES RM7888A Relay Module

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

7800 SERIES EC7885A/RM7885A Relay Module

Triton Series High Efficiency Boiler

Honeywell SLATE ICM Platform

Honeywell Thermal Solutions COMBUSTION CATALOG

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

7800 SERIES EC7823/RM7823 Relay Module

COMBUSTION CATALOG. Honeywell Thermal Solutions Honeywell Thermal Solutions Combustion Catalog

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

7800 SERIES RM7840E,G,L,M Relay Module

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

Project Name: Location: Engineer: Contractor: I. GENERAL

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

R7910A SOLA HC (Hydronic Control) R7911 SOLA SC (Steam Control)

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Power Flame Incorporated

7800 SERIES EC7890A,B; RM7890A,B,C Relay Module

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

CONDENSING HIGH EFFICIENCY BOILERS

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Power Flame Incorporated

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

HAWK INTEGRATED BOILER CONTROL SYSTEM

SOFTWARE INTERFACE SPECIFICATION - SOLA MODBUS INTERFACE

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

Distributed By: M&M Control Service, Inc Building Technologies

Commercial/Industrial Combustion Control Level Three Announcement

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

LFL Series Burner Flame Safeguard Control

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

- Data Brochure Universal Reset Module 423

DIVISION FINNED WATER-TUBE BOILERS

TABLE OF CONTENTS BRADFORD WHITE BOILERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Trinity Tft/Lx Model #s: Tft60-399/Lx Version Date:

YP7899C SERIES Burner Management Panel

HCLEARFIRE. High-efficiency, modular steam boiler HP

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

M6063A Compact Rotary Mixing Valve Actuator

New Versa IC Platform

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

Quickheat 30 weather compensated boiler control

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

- Data Brochure Universal Reset Module 422

Inventory Management Guide

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

WATER-TUBE POOL HEATERS

Instructions For A and Flame Simulators

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Less Than.25% Lead Proudly Assembled in the U.S.A

B-40/B-41 Modulating Temperature Controller

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

SECTION SAMPLE SPECIFICATION FOR BOILER CONTROLLER CONVERSION KIT

Revitalize Building Mechanical Systems (4619)

Inventory Management Guide

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

FTIIIC-10. Domestic Hot Water Heaters and Boilers

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

Technical Data Manual

DIVISION FINNED WATER-TUBE BOILERS

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

Less Than.25 Pb Proudly made in the U.S.A

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

Less Than.25% Lead Proudly Assembled in the U.S.A

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

Complete Boiler Management in a Compact, Affordable System

DIVISION FINNED WATER-TUBE BOILERS

SmartVFD HVAC and BYPASS

AFUE 95% Heating Input 50,000 to 200,000 Btuh

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

RM7838A 7800 SERIES Relay Modules

FXLF-9. High Efficiency Water Heaters and Boilers

Better Design, Better Control, Better Systems.

Domestic Hot Water Heaters and Boilers FTIIIC-6

Transcription:

Sola Hydronic Control An Eco-Friendly Solution.

Honeywell s Sola Boiler Control saves you money and reduces your carbon footprint! Efficient Boiler Control Honeywell s Sola Boiler Control offers energy saving features including: setback, fan and burner modulation, outdoor reset and multiple boiler lead lag control. he Honeywell Sola Boiler Control integrates 15 control functions into one compact device. Put it all together and Honeywell's Sola Boiler Control is your solution for efficient, integrated, and reliable boiler control! he Compact Solution 15 Integrated Control Functions Primary flame safeguard control Igniter/Spark generator (22kv 10 mj 60HZ spark/sec) Operating control: Central heat Operating control: Domestic hot water PID load control: Central heat PID load control: Domestic hot water High limit control: Boiler outlet High limit control: Domestic hot water High limit control: Stack temperature Outdoor reset control 3 Pump outputs with 5 assignable functions Stack temperature high limit Multiple boiler lead lag control Building automation router Remote firing rate interface Expanded Diagnostics 11-item programmable first-out annunciation 15-item lockout event history 15-item alert event history Flexibility With flexible display solutions, the boiler network can grow to meet future demand needs. User selectable names, functions, parameters, features and program settings allow tailoring each control to individual requirements With modbus RU protocol, connect Sola controls to a building automation system or up to 8 controls to one system display Remote firing rate control interface (4-20mA) DHW auto detection simplifies commissioning Instantaneous plate heat exchanger I/O and control logic Program interface modules back up and restore control parameters Low Fire, High Fire, and PWM Control Options Safety/Boiler Protection Boiler slow start function to prevent thermal shock Frost protection Anti-condensation 3 Delta- functions with inversion detection Outlet and heat exchanger -rise functions Stack, Boiler, Domestic hot water high limits UL353 Limit Rating: Stack emp or Operating Limit or Inlet/Outlet, Delta - 250 F Vessel High Limit Capability

Setback/ime Of Day Saves fuel by reducing boiler output temperatures for low use or unoccupied periods Outdoor Reset Saves up to 10 percent on average fuel usage Adjusts boiler output temperature to compensate for outdoor air temperature changes, causing boiler to operate at lower temperatures during mild weather Reduces unnecessary boiler cycling ypical Applications he Sola Boiler Control works with low mass and commercial boilers of all types. ypical applications may include apartment buildings, hospitals, retail complexes, schools, universities and office complexes. Fan And Burner Modulation Maximizes electrical energy savings and minimizes fuel use compared to fixed speed components Reduces fan speed and burner firing rate in response to modulation An ideal pairing with Premix components and Premix burner technology, which reduce NOx formation Lead Lag Save money and enhance equipment life Boiler cascade logic Boiler timed rotation Outdoor reset multiple boiler sequencing Multiple boiler pump control logic Base load and unison firing control logic Enhanced PID control to minimize equipment cycling Affordable Compare to purchasing, installing and maintaining 15 individual controls. Money Reduced installation, wiring and maintenance with integrated control functions Reduced energy usage helps save you money

he Hydronic Boiler Control Solution 24 Vac L2 Outdoor emp L1 Flame Signal Interlock Stack Alarm Outlet P P P Header emp PII Limit Input(s) Limit Annunciation (8) Remote Reset ime of Day Fan Boiler Ignitor Pilot Valve V Main Valve(s) V Intermediate Boiler Inlet Boiler Mix Loop Domestic Hot Water ank DHW Loop Key Central Heating Loop SA Remote Setpoint 4-20mA Local Keyboard Display Module Operator Interface Building Automation System P V Input Output emperature Input Pump Output Valve Output Honeywell's Sola Boiler Control is your solution to efficient boiler control!

Singular Control he Sola Boiler Control orchestrates multiple hydronic boiler functions, based on user programmable settings and priorities. Each boiler has a dedicated control, with an optional display for monitoring, adjustment diagnostics and trend analysis (model dependent). Central Heating is the main heating loop, while Domestic Hot Water comprises the optional secondary heating loop. User assigned priorities for each heat loop dictate which is addressed first. Choose he Sola Hydronic Control for Your Application Item R7910A1001 R7910A1019 R7910A1118 R7910A1027 R7910A1084 24 Vac Control Circuit 24 Vac Demand Input 24 Vac Load Circuit 120 Vac Load Circuit Modulation Output: PWM Modulation Output: 4-20 ma or 0-10V dc High/Low Fire Switch Inputs Flame Rod Flame Detection UV Flame Detection hermostat Input /Heat Anticipator Program Module PM7910A1013 Sola program back-up and restore of application parameters. Facilitates field control replacement. Interface Options S7910A1008 Local Keyboard Display Module LCD for monitoring and setpoint adjustment of a local Sola and the boiler it controls. Communicates via Honeywell 3-wire protocol. Order separately. S7999C1008, S7999C1016, S7999C1040 Local Operator Interface ouchscreen display for individual boiler configuration, control, remote monitoring, fault history and diagnostics. Provides visual indication of burner operational status, control variables, thresholds and lockout or alert events. Communicates via 3-wire RS-485 ModBus protocol. Order separately. S7999B1026, S7999B1067 System Operator Interface ouchscreen display for individual and multiple boiler configuration, control, remote monitoring, fault history, diagnostics and trend analysis. Provides visual indication of burner operational status, control variables, thresholds, lockout or alert events and trends. Up to 8 Sola devices may be monitored and controlled with a single system operator interface. Communicates via 3-wire RS-485 ModBus protocol. Enables Building Automation Interface to one or multiple Sola controllers. Order separately.

he Honeywell Solution Get the Honeywell advantage by combining the Sola Boiler Control with compatible Honeywell components for a compact and powerful boiler solution. For more information, visit customer.honeywell.com. Component C7027, C7035, C7044 UV Sensors C7007, C7008, C7009 / Q179A-B-C-D, C7005, Q347 V4730/V4734/ V8730C VMU Valves, Venturi Q624A, Q652B Solid State Spark Generators Purpose Minipeeper ultraviolet flame detectors. Disposable models and field replaceable UV tube models. Integral threaded collar and bracket mounted models. Compatible with Sola integral amplifier. Flame Rod Holders / Pilot Burner Assemblies for rectified flame sensing. Some gas pilot assemblies have integral ignition electrodes. Compatible with Sola integral amplifier. Q347 used for single rod spark and sense applications. Valve/Venturi compatible with modulating premix burners. Internal dual shutoff valves and regulator. A modulated combustion blower motor pulls the gas/air mixture through venturi, mixing in a 1:1 ratio for consistent burner operation. Modulation directed by Sola control. Capacity range of 512-2, 320k Btuh, sizes from ½ to 1¼, 24Vac & 120Vac. No proof of closure switch. High voltage solid state spark generators, 120Vac. Synchronized for use with UV sensors by sparking on one half of the ac cycle while UV sensors operate on the opposite half cycle. Prevents ignition interference. 32004766 Ignition wire. Note: cannot be used with the Q347 single rod spark/sense application. V4046C/8046C V4295A/8295A Gas Pilot Valves 198799Z 32003971-002 32003971-003 Sensors 50001464-006 50001464-007 Sensors A72D A88A Control ransformer ControLinks V5055C, V5097, V4055D Valves, Actuator V51E, M72x4, Q100 Valve, Actuator, Linkage 24 Vac and 120 Vac gas pilot valves provide on/off control of pilot burners. he V4046C valves are magnetically operated, while the V4295A valves are solenoid operated. Fits various pipe sizes between 1/8" and 2½". Single element 10KOhm NC resistive temperature sensors. emperature range of -40 F to +266 F. For use as inlet, header, outdoor and intermediate sensors. -002 sensor has 6" leads and Molex splice connector. -003 kit contains 198799Z sensor with 42 leads and all necessary hardware for strap-on or outdoor mounting. Dual element 10K Ohm NC resistive temperature sensors. emperature range of -40 F to 266 F. For use as outlet and domestic hot water operation/limit sensors. May be used for stack limit sensor if temperature specifications are not exceeded. -006 sensor has 6" leads and Molex splice connector. -007 sensor has 42" leads. 24 Vac, Class 2 control transformer for powering the Sola control. A72D is 40 VA and the A88A is 75 VA. Various configurations available for each. he ControLinks fuel air ratio control system may be used with the high/low fire switch input versions of Sola. Maximizes combustion efficiency over the entire firing rate curve with independent actuators. Uses a ControLinks system display. Safety shut-off valves and on/off actuator. Available with integral proof of closure switch. Modulating valve, modulating motor and butterfly valve linkage. Actuator accepts 4-20 ma signal from control and are available in 24 Vac or 120 Vac. Valve not suitable for safety shut-off applications. Fuel and air must be mechanically linked for proper operation. 775M Control May be used for 4-20mA remote setpoint or modulation control inputs.

Sola Hydronic Control Condensed Specifications Application Modulating hydronic low mass or commercial boilers with central heating and domestic hot water loops. 24 Vac or 120 vac load circuit with 24 vac control circuit. All features are integral to control: 2 Boiler control loops Primary flame safeguard control Igniter/spark generator Central heat operating control Central heat high limit control Central heat PID load control Domestic hot water operating control Domestic hot water high limit control Domestic hot water PID load control Outdoor reset control 3 Pump outputs with 5 assignable functions Stack temperature high limit control Expanded annunciation Slow start function Frost protection Anti-condensation protection 3 Delta- functions with inversion detection Outlet and heat exchanger -rise functions Stack rate limit function Prioritization for demand, rate limiting Multiple boiler lead lag control Building Automation Router Remote firing rate interface Instantaneous plate heat exchanger I/O and logic Lead Lag logic; cascade, timed rotation, outdoor reset, pump control, base load-unison firing, enhanced PID to minimize equipment cycling. Required Components Optional Components Electrical Ratings Ambient emperature Range Humidity Range Dimensions (W x H x D) Approvals Communication Controller: R7910A1001/R7910A1019/R7910A1118/R7910A1027/R7910A1084 Plug connector bag assembly: 50032893-001 Operator interface: S7999B1026/S7999B1067/S7999C1008/S7999C1016/S7999C1040 (configure/monitor boiler) UV Sensors: C7027/C7035/C7044 Flame rod holders/pilot burner assemblies: C7007, C7008, C7009/Q179A-B-C-D, C7005, Q347 Inlet/header/outdoor/intermediate temperature sensors: 198799Z or 32003971-002 (purchase qty needed) Header and outdoor temperature sensor kit: 32003971-003 (purchase qty needed) Outlet and domestic hot water operation / limit sensors: 50001464-006 or 50001464-007 (purchase two if using both functions) Stack limit sensor: 50001464-006 or -007. Maximum 266 F (130 C) Local keyboard display module: S7910A1008 (for monitoring, setpoint adjustment) Program module: PM7910A1013 (back-up, restore) Control transformer, 24 Vac, Class 2: A72D (40VA) or A88A (75VA) R7910A1001: 24 Vac (+25%, -16.6%), 50/60 (+-5%) Hz load circuit R7910A1019/1027: 120 Vac (+10%, -15%), 50/60 (+-5%) Hz load circuit All R7910A: 24 Vac (+25%, -16.6%), 50/60 (+-5%) Hz control circuit voltage; Requires Class 2 control transformer S7910A: 24 Vac, obtained from Sola 3-wire interface S7999B/S7999C: 100-240 Vac, 50/60 Hz power input to a separate power supply (included) R7910A: -4 F to 150 F (-20 C to 66 C) S7910A: 32 F to 120 F (0 C to 49 C) S7999B: 32 F to 122 F (0 C to 50 C) R7910A: up to 95% Relative humidity, non-condensing S7910A/S7999B/S7999C: up to 85% Relative humidity, non-condensing R7910A: 6 x 9 x 3 installed (152mm x 229mm x 76mm) S7910A: 5.7 x 4.1 x 1.1 (141mm x 102mm x 51mm) S7999B: 9.4 x 6.7 x 1.6 (239mm x 169mm x 40mm) S7999C: 7.2 x 5.1 x 0.8 (183mm x 128mm x 21mm) R7910A: UL/cULComponent Recognized, CSD-1 Acceptable, FCC (Part 15, Class B, Emissions) S7910A: FCC (Part 15, Class A digital device), UL/cUL Listed S7999B/S7999C: FCC (Part 15, Class A digital device), UL/cUL component recognized ECOM: Honeywell 3-wire interface for communication with dedicated local display keyboard display Modbus MB1: 3-wire RS-485 interface for Modbus network; Up to 8 device connections Modbus MB2: 3-wire RS-485 interface for Modbus network; Up to 8 device connections

Learn More For more information please contact your Honeywell distributor. Or visit http://customer.honeywell.com. Automation and Control Solutions In the U.S.: Commercial/Industrial Combustion Controls Honeywell 1985 Douglas Drive North Golden Valley, MN 55422-3992 In Canada: Honeywell Limited 35 Dynamic Drive oronto, Ontario M1V 4Z9 www.honeywell.com 63-9725 PR November 2010 2010 Honeywell International Inc.