CONTINUOUS RIDGE VENTILATORS

Similar documents
Model L - W - H Description Construction Wt 1 to 5 6+

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

Industrial Fans & Blowers

Direct Fired Heater Model AD Specification

FAS-300 Central Dust Collection Systems

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Portable Vertical Air-Conditioning and Heating Systems

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Low Wall Back Shelf Exhaust Canopy

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

IMPORTANT! READ BEFORE PROCEEDING! CI3H - CI12H, CI81S Ceiling & Inline Fans

SECTION AIR OUTLETS AND INLETS

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

OFF-RIDGE VENTILATION PRODUCT BROCHURE

GA Gas Unit Heater Assemblies Technical Guide

Bulletin FH05 FUME EXHAUST

Heat or Energy Recovery Ventilation System

ZEPHYR Ceiling Exhaust Fans

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

University of Houston Master Construction Specifications Insert Project Name

Twin City Fan & Blower

Project Name: Location: Engineer: Contractor: I. GENERAL

Sheet Ref. CSCONTENTS May Revision 0

MANUAL RESET ALARM RELEASE BOX

TECHNICAL SPECIFICATIONS

MX 200. MX-200 Technical Specifications FEATURES:

Section 9 - Tumble Dryers. Tumble Dryers LEPH

Hubbell NX500 High Efficiency Gas Condensing Water Heater

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

Packaged Terminal Air Conditioner (PTAC)

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Our energy efficient experts and engineers have made ground breaking innovations in this field.

THREE-WAY HEAT SAVER/VENTILATOR

Convectors Steam / Hot Water November, 2009

ST. KITTS CEILING FAN

Inspection Checklist Mechanical Rough in

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

Broiler Feeding System

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

2012 INTERNATIONAL FUEL GAS CODE VENTS

ZEPHYR Ceiling Exhaust Fans

GUIDE TO GOOD VENTILATION

HEAT & SMOKE VENT INSPECTION AND MAINTENANCE PACKET

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

MX 200. MX-200 Technical Specifications FEATURES:

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

GLOBAL FINISHING SOLUTIONS

Deluxe Welding Tool Chest

SAFETY AND INSTALLATION MANUAL MODEL 8100

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

HE120, HE160 Humidifier Installation Kit

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Inspection Checklist Mechanical Final

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

36"x17" Portable Tool Chest and 6-Drawer Tool Cabinet

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A guide to looking after your windows, doors and conservatories. spectus n. look, appearance, aspect

NU800, NU1200 & NU1600

XeteX, Inc. All Rights Reserved.

SECTION GYPSUM PLASTER

KIC Air Curtains. Technical Guide

Mobile Heated Cabinet

Day after day, Season after season, Generation after generation.

A GUIDE TO LOOKING AFTER YOUR WINDOWS AND DOORS

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

SECTION AIR DUCT ACCESSORIES

CFH Series High Efficiency Filters

Packaged Terminal Air Conditioner (PTAC)

Hoop House / Greenhouse Kit Instructions Sample Version

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Steel Storage Cabinets

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

Do not use this vent pipe or fittings for venting incinerators of any kind.

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

B. Design meeting requirements of the particular class and type of cabinet as follows:

Models , Equinox, and Sirens Clutch Replacement Service Manual

Packaged Terminal Air Conditioner (PTAC)

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

7700 & 5400 PATIO DOORS ATIO DOORS

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

1.1 This section applies to air handling units for HVAC Systems.

PROFESSIONAL AIR MOVER OWNER S MANUAL

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Luxury Greenhouses 1

Ventilation Techniques. Topic 5 - Audio 53

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

VENTILATED Wire Shelving

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

SASH WINDOWS. Office: Mob: or us at

4 Storage cabinets SCALA

Transcription:

CONTINUOUS RIDGE VENTILATORS A properly engineered ventilation system using continuous ridge ventilators controls the movement of fresh air through the building removing hot, stale air and air contaminated by manufacturing or production processes. Summer heat is released naturally through gravity ridge ventilators. During winter proper ventilation can assist in the control of condensation and other moisture problems, such as rust and deterioration of insulation or the damage to stored products. Vents may be furnished with or without dampers to control the flow of air. Pull chains are the standard operators for dampers. Multiple damper operations are available for two or more units. Standard ridge ventilators are shipped with a 1:12 end cap and can be field modified to accommodate up to a 6:12 roof pitch. Ventilators can be custom ordered to accommodate roof pitches greater than 6:12. 9" and 12" Throat Continuous Ridge Ventilators ALSO AVAILABLE Metallic Products 9" and 12" throat continuous ridge ventilators are also available in Florida Approved specifications. SPECIFICATIONS STANDARD SIZE 9" throat and 12" throat available in 10' sections. Low profile design can be used for single unit or continuous run installation with no disassembly. Additional sizes: 4", 15", 18", 24", 30", 36", 42" and 48" For custom lengths or throat sizes, please contact your sales representative. INTEGRAL DAMPERS Easy-moving damper opens to any degree from fully open to completely closed. Lockerpull operator is standard and comes with 10' sash chain and chain keeper. Check out our ridge vent operator selections for hand pull, lever, boatwinch and operation extension options. DESIGN Aerodynamically proportioned to exclude weather. Protects air passages and full outlet area. BIRD SCREEN Fully protected by 4 x 4 bird screen mesh galvanized hardware cloth. CONSTRUCTION Durable 26-gauge exterior combined with internal components of 24-, 20- and 18-gauge die formed sheet metal and machined parts for long service life. FINISH Galvalume or Polar White finish is standard, and other colors are available including Kynar. DRAINAGE AREA Continuous slot drainage placed at the bottom of both sides of windbands. NOTE Please specify flat or die form skirts, roof pitch, damper operator and color when ordering.

DIMENSIONS THROAT* A B C D E 4" 6-1/4" 12-1/2" 9" 10" 18" 9" 13" 21-1/4" 14-1/2" 18" 28-1/4" 12" 17" 28-1/2" 18" 22" 33" * Other throat sizes available upon request. SHIPPING WEIGHT THROAT STANDARD CRATED PACKAGE SIZE (L x H x W) 4" 190 lbs.** 125" x 14" x 20" 9" 230 lbs.** 125" x 19-3/4" x 30-1/2" 12" 250 lbs.** 125" x 22-1/2" x 34-3/4" ** Approximate weight.

15" TO 48" THROAT WELDED FRAME RIDGE VENTILATORS NOTE: Exterior and interior frame made of 1/8" x 1-1/2" x 1-1/2" angle hot-dipped galvanized after welding. All other parts made of 22-gauge sheet metal, standard white or galvalume. A A/2 B C D E F G H J K L M N P WT. (lbs.) 15 7-1/2 39 26-1/2 8 22-3/4 11-3/8 11-3/8 9-7/8 5 6-1/2 7-1/2 16-7/8 8 25 275 18 9 45-5/8 30-5/8 10-5/8 26-3/4 13-3/8 13-3/8 11 5-7/8 8-1/4 9 18-5/8 9-1/2 30 300 24 12 57 38-3/8 11-7/8 33-1/2 16-3/4 16-3/4 13-5/8 8-1/8 9-1/4 12 21-1/2 11 36-1/8 400 30 15 70-1/8 45-9/16 14-3/8 41 20-1/2 20-1/2 14 9-1/2 11-5/8 16 26-5/8 11-3/8 49-1/4 450 36 18 81-1/4 53-5/8 16-7/8 47-1/2 23-3/4 23-3/4 19-1/2 12-3/8 12-1/2 18 26-1/2 14-1/4 55 500 42 21 94 61 18-7/8 56 26-13/16 26-5/16 22-1/2 14-1/2 13-9/16 21 31-1/4 16-5/8 62 575 48 24 106 65-7/8 19-1/4 67-1/4 27-1/4 27-1/4 26-7/8 16-7/8 13-5/16 24 34-1/8 20-1/8 67-1/8 650 Purlin Spacing = P Plus 3" Each Side

TABLE OF CAPACITIES FOR CONTINUOUS VENTILATORS CAPACITY: To determine capacity per unit, multiply Base Rating by Temperature-Height Factor : CFM = Base x Temperature-Height Factor Based on fresh air intake area 1-1/2 times ventilator throat area. Assumes 5 mph wind speed. THROAT SIZE BASE RATINGS C.F.M. 4" 1200 9" 2700 12" 3600 15" 4500 18" 5400 24" 7200 30" 9000 36" 10800 42" 12600 48" 14400 HEIGHT TEMPERATURE-HEIGHT FACTORS TEMPERATURE DIFFERENCE 5 10 15 20 25 30 35 40 45 10'.37.49.58.64.70.76.81.86.95 15'.42.60.71.80.86.92.99 1.05 1.09 20'.53.70.81.92.99 1.07 1.14 1.22 1.26 25'.58.77.89 1.00 1.08 1.18 1.25 1.33 1.36 30'.63.83.97 1.08 1.17 1.28 1.36 1.45 1.50 35'.66.87 1.02 1.14 1.24 1.35 1.44 1.51 1.58 40'.70.93 1.08 1.22 1.30 1.41 1.50 1.61 1.68 45'.74.96 1.12 1.28 1.38 1.48 1.59 1.68 1.75 50'.77 1.01 1.18 1.33 1.44 1.56 1.67 1.75 1.83 55'.80 1.06 1.23 1.39 1.50 1.64 1.72 1.83 1.92 60'.83 1.09 1.28 1.44 1.55 1.69 1.79 1.90 2.00 65'.85 1.12 1.32 1.48 1.61 1.74 1.85 1.97 2.06 70'.88 1.17 1.36 1.53 1.67 1.79 1.89 2.02 2.11 75'.90 1.19 1.39 1.57 1.69 1.83 1.96 2.06 2.17 80'.93 1.22 1.42 1.61 1.72 1.86 2.00 2.11 2.20 Height = Vertical rise from inlets near floor to ventilator Temperature = Estimated temperature difference between middle of air intake near the floor and ventilator with dampers open

CONTINUOUS RIDGE VENTILATOR OPERATORS OPERATOR A HAND PULL 40' Cable (1) Chain Catch OPERATOR C LEVER (6"-9" vents and 4"-12" vents) 40' Cable (1) Eyebolt (not welded) with Nuts (1) Lever Handle with Mounting Hardware (1) Installation Instructions OPERATOR D BOATWINCH (8"-9" vents, 6"-12" vents, 4"-24" vents and 3"-36" vents) 60' Cable (1) Boatwinch (1) Cable Catch (2) Eyebolts (not welded) with Nuts (1) Mounting Hardware (1) Installation Instructions OPERATION EXTENSION 50' Cable (2) Eyebolts (not welded) with Nuts DUFF NORTON OPERATOR Duff Norton Motor (10-9" vents, 7-12" vents)