ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

Similar documents
Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

ME 3011C / Alarm Indication / Quick Reference Guide

Signal Processing System ME30 infobox

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_v0707_Pre.doc 1/50

Alarm Systems. Digital Alarm Annunciator. ME 3011b Instruction Manual SERIAL PRODUCTS. Manual ME3011b_E_r07 at 1/68

Mosaic System-Control Room Technology. Illuminated Pushbutton and Pushbutton Switch LT 1879 / LT 2479 LS 1879 / LS 2479

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

M1000 Alarm Annunciator

Parameterisable compact fault annunciator with permanent display

Annunciator Unit SACO 16 D1. Product Guide

Panel Mounted Fault Annunciator Series

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

Universal fault annunciator for panel mounting

System 9000TS Sequence of Events Recorder

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Beckhoff short profile

AIS750 Series Alarm Annunciator

Panel Mounted Fault Annunciator Series

Annunciator unit. Application

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Window facia fault annunciators

/8 DIN Level Indicator

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Return loss measurement of fiber optic components

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

KNX The worldwide STANDARD for home and building control. KNX Association International

AO Annunciator Module

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Accuracy counts! Sensors with analog output

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

DRAFT 20 October 2014

Model A1700 Series Annunciator

725B Configuration Software Manual

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Series 725 Programmable Alarm Annunciator

Installation / Monitoring Technique

Installation Instructions

M2500 Engine Controller Installation Manual

AN-3100D Annunciator

Analog Annunciator Unit SACO 16 A3. Product Guide

STT 3000 Series STT250 /150 Surge Protection Device Specifications

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Model A2100 Series Annunciator

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Remote alarm indicator and test combination MK2430

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

RTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment

XLH210: controller for gas leak detectors

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

KNX The worldwide STANDARD for home and building control. KNX Association International

CRA24-B3 controlled residential ventilation

Lift Station Level Controller

E-T-A Get Smart With Your Systems

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

Complex alarming made simple

Photoelectric laser sensors E3C-LDA SERIES. l o n g - d i s t a n c e, a d j u s t a b l e l a s e r b e a m. Advanced Industrial Automation

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Operation Manual Part-No

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

RS485 MODBUS Module 8AI

ID3000 intelligent. fire alarm panel

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

ID3000 intelligent. fire alarm panel

Carbon Monoxide Transmitter

I/A Series 716C 1/16 DIN Temperature Controller

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

On the job around the clock 24/7: Fire detection systems

Videomatrix SIMATRIX 648

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

International standards used locally worldwide ISO/TC 67

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

System 57. An advanced world of intelligent gas detection system management

Call stations and extensions

micropac. Personal Gas Detection Instruments

PTG, SWT Series. Heat Recovery Systems

Safety Light Curtain F3SG-R

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

System 9000TS Sequence of Events Recorder

SIL725 Safety Annunciator

MSM - Expansion modules

System 57. An advanced World of intelligent gas detection system management

The advantages of closed heating systems. White paper

SEL-2523 Advanced Annunciator Panel

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

Technical Manual. Level Alarm Unit CARLA & WIDS

M2000 Engine Controller

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

SIMATRIX NEO Modular Video Matrix

Transcription:

Electronic Alarm Indication Systems ME 3011 compact Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment

2

Table of Contents Contents Page System Characteristics Housing Versions Signaling Sequences Technical Data Terminal Assignment 10 Software Tools 11 3

System Characteristics The ME 3011 compact series of our ME 3011 alarm system family is characterized by its small installation size for the standard formats with mm grid dimension and the high packing density of the available messages. ME 3011 compact is available in three versions: ME 3011 compact with LED display - Intelligent message processing, indication and transmission - 12, 2, or 0 messages, expandable - Message indication on yellow LED display - Different signaling methods - Message texts on printed paper labels - Operation by means of front pushbuttons or external inputs - Communication capability ME 3011 compact with backlight display - Intelligent message processing, indication and transmission -, 10 or 1 messages, expandable - Message indication by means of innovative wide band backlight LED rear illumination - Signalizing colors: red, green, white, yellow and blue - Different signaling methods - Message texts on printable front foil - Operation by means of front pushbuttons or external inputs - Communication capability ME 3011 compact Signalizing with backlight display - Solely for message indication -, 12 or 1 messages - Expanding unit for ME 3011 compact or standalone unit - Signalizing by means of innovative wide band backlight LED rear illumination - Signalizing colors: red, green, white, yellow and blue - Connection via ribbon cable for expandable units or terminals - Message texts on printable front foil Communication options such as an IEC 00--10/101 interface can be easily integrated. ME 3011 compact combines modular design with compact size and a defined number of messages to provide a powerful yet cost-effective alarm indication solution.

Housing robust metal housing No. of points to 0 points Housing versions housing versions (in mm) x, 12 x, 2 x, 3 x Cut out table 1 x 1, 1 x 1, 23 x 1, 3 x 1 (in mm) Arrangement gap less stack mounting Mounting depth 11 mm for all housing versions Terminals plug-in spring terminals Supply voltage 2 V DC or 110/220 V DC and/or 110/230 V AC redundant Message input voltage 2 to 220 V DC Configuration RS 232 interface for configuration via PC BUS integrated slave Modbus interface up to 1.200 Baud Message memory event memory with 2, ms accuracy Signaling different ISA signaling methods Flashing synchronization integrated flashing synchronization input/output Optical alarm indication LED or new backlight LED indicator message indication easily replaceable labels or printable plastic front foil Message dissemination relays for all messages Group message outputs 3 relays for groups messages or external horns Potential separation all interfaces galvanically isolated signal 2 internal horns Operation push buttons at the front or separate function inputs EMV acc. to DIN EN 1000- Environmental temperature range 0 to C Configuration configuration software for free Optional visualization tool e-view Optional IEC 00--101- and IEC 00--10 interface

Housing Versions ME 3011 compact Dimensions W x H in mm x 12 x 2 x 3 x bezel 1 x 1 1 x 1 23 x 1 3 x 1 panel cutout ME 3011 compact with LED indicator ME 3011 compact with backlight indicator ME 3011 compact Signaling with backlight indicator Rear view

Signaling Sequences The ME 3011 can be configured in order to comply with 1 signaling sequences. Among them the most important are the following: ISA-RP 1.1/(ISA-S1.1) ISA-1/(A), ISA-1A/(A-), ISA-1B/(A-), ISA-2A/(R-), ISA-2C/(M), ISA-A/(F1A), ISA-AR/(F1M) etc. Other sequences can be implemented on request. Alarm sequences REF ISA ALARM NORMAL ABNORMAL Acknowledge Back to Back to Acknowledge RESET NORMAL NORMAL before Acknowledge ISA 1 ISA 1A ISA 1B ISA 2A F F S F F S ISA 2C (M) default PRIMARY SIGNAL SEQUENCES (1 st Event) Back to NORMAL REF ALARM NORMAL ABNORMAL Acknowledge Back to NORMAL before Acknowledge Acknowledge RESET ISA Initial Subseq. Initial Subseq. Initial Subseq Initial Subseq. Initial Subseq ISA A ISA R LEGEND F = Fast LED Off Siren = Off LED On S = Slow LED intermittent Siren = On

Technical Data Electronic Alarm Indication Systems ME 3011 compact 1 Supply Voltage 1.1 Power Supply Standard 2 V DC ± 20 % 1.2 Power Supply Input 110 to 220 V DC, ± 20 % and/or 110 to 230 V AC, ± 20 % redundant contingent Output 2 V DC/0,0 A 1.3 Power supply fault detection AC and/or DC 2 Alarm or message inputs 2.1 Input to 0 Potential separation optocoupler Input voltage Input current Input filter 2.2 External push button inputs Input voltage 2,, 0, 110/20 V DC, ±20 % 3 ma (typical) lower value = ms, configurable in steps of 2, ms 2 V DC 2.3 Flash synchronism output/input and/or flash 2 V DC Potential separation optocoupler 2. Minute pulse input 2 V DC Potential separation 3 Outputs optocoupler 3.1 Relays 3 freely programmable relays for various functions, e. g. external buzzer, voltage fault, alarm group 3.2 indication 0 db / 10 cm, khz 3.3 Repeat relays (option) 1 floating contact for each alarm point 3. Repeat relays for power 1 floating contact for each supply fault detector PSFD Note: Contact capacity for all relays is A / 2V DC for resistive load. Maximal switching voltage: 12V DC / 20 V AC Potential separation Functions: acknowledgement (HA) optocoupler like push button Interfaces.2 Communication for configuration RS 232 RS 232 bi-directional (option) Baud rate 00, n,, 1 acknowledgement (LA) Delete/Reset (RE) like push button like push button test/ Function test (LT) like push button T Push button inputs without function Keyboard OFF KB/O.3 Communication for- Modbus RS RS bi-directional, serial (option) communication (configurable) Baud rate 110 to 1 200 Parity even, odd or none Stop bit 1 or 2 Protocol Modbus RTU (Slave) Sleep Mode SLM

Event register.1 Events 1.000 with time stamp.2 Resolution 1 ms, samples 2, ms.3 Interface RS. Protocol Modbus RTU (Slave) General.1 Alarm sequence ISA 1, 1A, 1B, 2A, 2C, A; others on request.2 Environment Operation temperature 0 to + C Storage temperature - 20 to + 0 C Visualization.1 indicators LED indication Wide band backlight color: yellow available in red, green, white yellow and blue Relative Humidity.3 Protection class IP0 0 to %, without condensation. Isolation 2 kv, 0 Hz, IEC 02-. Emission DIN EN 011. ESD DIN EN 1000--2.2 Flashing frequency fast: approx. 1,2 Hz slow: approx. 0, Hz. EM HF field DIN EN 1000--3. HF inflow DIN EN 1000--. Burst DIN EN 1000--.10 Surge DIN EN 1000--.11 Terminals Teminal connectors (removable) for cables up to 1, mm 2 Phönix Combicon,0 grid.12 Tropicalized type special option on request

Terminal Assignment Power Supply 2 V DC + F1 L1+ 1 + F2 L2+ 2 M 3 Flash Sync. Min.Imp M (2V) Firmware Upload Modbus Termination Modbus Config PC ME3011c_12x0_Anschaltung_e.EPS 2V PE +2V Signal-Input Input 1 1 Input 2 2 Repeater-Output 1 Rep.1 2 Rep.2 Programmable Relay Output,, RLa RLb external Horn Input 3 3 3 Rep.3 RLa Remote Push-Buttons KB off 1 Input Input Input Input Rep. Rep. Rep. Rep. 10 11 RLb RLa RLb Signal-Input Input 13 1 Input 1 2 Input 1 3 Repeater-Output 1 Rep.13 2 Rep.1 3 Rep.1 Signal-Input Input 21 1 Input 22 2 Input 23 3 Repeater-Output 1 Rep.21 2 Rep.22 3 Rep.23 SLM 2 Input Rep. 12 L1+ Input 1 Rep.1 Input 2 Rep.2 HA 3 Input Rep. 13 L2+ Input 1 Rep.1 Input 2 Rep.2 LA Input 10 10 10 Rep.10 1 L+ Input 1 Rep.1 Input 2 Rep.2 RE Input 11 11 11 Rep.11 Input 1 Rep.1 Input 2 Rep.2 FT/LT Input 12 12 12 Rep.12 +2V Input 20 Rep.20 Input 2 Rep.2 M M 13 13 L+ 2V M L+ M L+ optional +2V extern + extern + extern + + Power Supply extern Output +2 V + extern + extern + extern + extern 10

Software e.tools This annunciator can total be represent for software. Software e.tool ME 3011 config presents ample functionality that facilitates its use, bringing to the user all the configuration possibilities of the product. ME 3011 brings powerful tools of dedicated supervision and control for applications in nets of indication systems. With intelligent user and not complicated an interface of, e.tool ME 3011 view brings to the screen annunciating virtual with information in real time, beyond register events with resolution 1 ms. RS232C interface (option) with, 10 or 1 m cables RS interface up to 10 annunciators in one NET advanced communication protocols enhanced maintenance oriented functions event recording with 1,0 ms resolution with samples each 2, ms 11

Head office Germany Helmut Mauell GmbH Am Rosenhügel 1-23 Velbert Germany Brazil Helmut Mauell do Brasil Ltda. Klaus Liesenberg Estr. Est. Salvador de Leone 2 ITAPECERICA DA SERRA 00-000 ITAPECERICA DA SERRA SAO PAULO Brazil Netherlands Helmut Mauell B.V. Jan Groot Fahrenheitstraat 3-0 3 AB HARDERWIJK Netherlands Switzerland Mauell AG Markus Huber Furtbachstraße 1 10 BUCHS Switzerland USA Mauell Corporation Gary M. Suchy 31 Old Cabin Hollow Road DILLSBURG PA 101 USA Africa Argentina Australia Austria Belgium Czech Republic Denmark Finland France Great Britain Hungary Indonesia Iran Korea Kuwait Malaysia Norway Poland Portugal Rumania Russia Sweden Singapore Spain Thailand Turkey U.A.E. 0.3011.0E01 www.mauell.com