CARBON MONOXIDE (CO)

Similar documents
2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

Travis County Emergency Services District #1 Standard Operating Guidelines

Manhattan Fire Protection District

Model Carbon Monoxide (CO) Alarm Response Policy

Carbon Monoxide Poisoning

CARBON MONOXIDE DETECTOR, i4h-co-m330

Carbon Monoxide Alarm

Seriously how do you know your CO monitor is Working!

Carbon Monoxide Detectors. What is carbon monoxide?

Carbon Monoxide Detection in Buildings Frequently Asked Questions

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

LOMBARD FIRE DEPARTMENT ILLINOIS CARBON MONOXIDE ALARM DETECTOR LAW. Carbon Monoxide Law. Takes effect January 1, 2007 One outside each sleeping area

Office of the Fire Commissioner

Frequently Asked Questions About Carbon Monoxide Detectors

What is carbon monoxide (CO) and why do I need a carbon monoxide detector?

Protecting Children from Carbon Monoxide Poisoning

Carbon Monoxide Safety Information

Natural Gas Pipeline Safety. EDM Services, Inc. April 2009

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

OWNER S MANUAL for Models:

Carbon monoxide Knowing more

Ontario is taking another step to keep families and homes in Ontario safe by making carbon monoxide alarms mandatory in all residential homes.

PSE&G Emergency Responder Program Review

Carbon Monoxide Alarm Owner s Manual

Carbon Monoxide Alarm Response Guide. High Country Training Center Training On Demand

Frequently Asked Carbon Monoxide Questions

Contents

Safety Awareness Bulletin: Upgrading from CMD-2M, CMD-3M and CMD-4M CO Detectors to NEW CMD5-MD 12/24 vdc CO Alarms

Carbon monoxide household alarm. DURAN ELECTRONICA. Tomás Bretón 50, Madrid, Spain

OWNER S MANUAL for Models:

Carbon Monoxide Alarm with Safety Shut-Off

RV Carbon Monoxide Alarm

Special Edition. Routt County Office of Emergency Management. Carbon Monoxide The Silent Killer. What is Carbon Monoxide (CO)?

This About Your House answers often-asked questions about carbon monoxide to help you make the right decision to make your home safe.

Macurco Gas Detection Products

can quickly rise to dangerous levels

Marine Carbon Monoxide Alarm

TEXAS A&M UNIVERSITY EMERGENCY MANAGEMENT. Home Safety. Smoke Alarms

carbon monoxide Preventing carbon monoxide poisoning in your home

about your house Carbon Monoxide

Home Heating MORE THAN JUST STAYING WARM

The Village of Franklin Gas Safety Pamphlet

C8600A CO Alarm OWNER S GUIDE RESIDENTIAL USE ONLY

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

PROTECT YOURSELF AND YOUR FAMILY FROM THE SILENT KILLER IS YOURS INSTALLED?

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

Carbon Monoxide Room Alarm Installation and User Guide Part No:

Low Level CO Monitor Owner s Manual

EL195DFE SERIES GAS FURNACE WARNING

Notes From the Commish

HOLLY HILL FIRE DEPARTMENT

WELCOME TO ROSEVILLE UNIVERSITY

From Your Building Inspector

EL195UH SERIES GAS FURNACE WARNING

United States CONSUMER PRODUCT SAFETY COMMISSION Washington, D.C

Battery Powered Commercial CO Monitor

TIMOTHY R. SZYMANSKI Instructor

Commercial Carbon Monoxide Detector Owner s Manual

U.S. Consumer Product Safety Commission Washington, DC 20207

Carbon Monoxide. The Silent Killer. Joe Fobert. Frank Wright, Ph.D. Steve Tagert. by:

LA GRANGE FIRE DEPARTMENT JANUARY 2018

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL Models RV & RV ABOUT THIS ALARM

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Models & ABOUT THIS ALARM

G61MPV SERIES GAS FURNACE WARNING

System-Connected Carbon Monoxide Detectors

OWNER'S MANUAL PLEASE READ AND SAVE!

Red Alarm Indicator Light

USER S INFORMATION MANUAL

EL296UHV SERIES GAS FURNACE WARNING WARNING

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

Suburban Propane Notice of Public Awareness. Additional Information for Customer s Buried Piping

SAFETY TIPS. From Your Building Inspector. The Sound of Safety.

Housing Division Notice

Carbon Monoxide Poisoning READ ONLINE

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

Natural Gas Safety In Your Home

Non-Fire Carbon Monoxide Deaths and Injuries Associated with the Use of Consumer Products Annual Estimates

COMPUTHERM. CO1400 Carbon Monoxide Alarm OPERATING INSTRUCTIONS

Arvada Fire Uses Advanced Gas Monitors To Keep Citizens and Responders Safe

Content Rev

EL195UHE SERIES GAS FURNACE WARNING WARNING

NATURAL GAS SAFETY. Your safety. Our priority Update

ML180UH SERIES GAS FURNACE WARNING WARNING

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL 65 Series Surface Mount Models: , R, MS, R-MS

WARNING FIRE OR EXPLOSION HAZARD.

WARNING FIRE OR EXPLOSION HAZARD.

Fire Prevention Information

FIRE PREVENTION AND SAFETY IN THE HOME. Provided to You by Lawrence Laviolette CD Fire Safety Officer

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Carbon Monoxide Alarm User s Manual

Carbon Monoxide and Gasoline Powered Smoke Blowers STRATEGIC MANAGEMENT OF CHANGE

Installation and User Guide

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

3 Macurco Carbon Monoxide Detector CM-16A

DETECTION. confined space. Professional. New OSHA Rule: Product Spotlight: A Reminder of the Importance of Atmospheric Testing and Monitoring

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM

CARBON MONOXIDE ALARMS. Senate Bill 920. Session of Public Hearing June 22, Testimony of:

Transcription:

DCN: 3.02.16 FIRE TACTICS AND PROCEDURES HAZARDOUS MATERIALS 4 March 15, 1997 (CO) 1. INTRODUCTION 1.1 Due to increased public awareness and the availability of carbon monoxide (CO) detectors for the home, the Fire Department is being called to investigate activated CO detectors and other CO related emergencies. 2. PROPERTIES 2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas. 2.2 CO is a natural by-product of incomplete combustion from fuels such as (gasoline, wood, coal, propane, oil and methane). 2.3 In the home, heating and cooking equipment are possible sources of CO. Vehicles running in an attached garage can also produce dangerous levels of CO. When a faulty appliance or unusual condition exists, CO may be vented into areas where people are present. CO has been known to vent into nearby buildings from manhole fires. 2.3 Virtually undetectable without special instruments. 2.4 It is a flammable gas with an auto ignition temperature of 1128 Degrees F., and a Lower Explosive Level (LEL) of 12.5% and an Upper Explosive Level (UEL) of 74%. 2.5 CO has a vapor density which makes it slightly lighter than air (.968). Since warm air rises, CO rises with it. E.g. air from a furnace, hot water heater, or a fire. Once this emitted air cools to room temperature, CO will disperse evenly through the room. 2.6 All ladder companies have been issued CO meters. Units responding to suspected CO incidents shall be guided by the procedures in Sections 4. 1

3. Health Hazards 3.1 CO can kill before its presence is known. 3.2 Provides no early warning signs. 3.3 Displaces O 2 in bloodstream and asphyxiates victim. 3.4 Highly toxic. 3.5 CO is absorbed into the body through the lungs where it is transferred to your blood. 3.6 Once in the body it combines with hemoglobin and becomes a deadly compound called carboxyhemoglobin (COHb). Poisoning is measured by percentage of COHb in the blood. 3.7 COHb reduces blood s ability to transport O 2 to the body. 3.8 Reduced O 2 harms life support functions ( brain, cardiac and respiratory activity). 3.9 CO has a greater affinity for hemoglobin than O 2. CO is about 210 more attracted to hemoglobin than O 2. 3.10 Final levels of COHb depend on the following factors: a. Initial COHb concentration. b. Concentration of CO inhaled. c. Length of CO exposure. d. Activity while inhaling CO. e. Body size and other physiological factors. 3.11 To reverse the buildup of COHb in the body, over 200 parts of oxygen are required to replace one part of CO. 3.12 Symptoms of CO Poisoning: a. Low Level CO Poisoning- can mimic flu symptoms, headache (mild/severe), fatigue, nausea, dizziness, confusion, irritability. b. Medium Level CO Poisoning- vomiting, drowsiness, loss of consciousness. c. High Level CO Poisoning- seizure, coma, permanent brain damage, death. 2

3.13 Signs and Symptoms at Various Carboxyhemoglobin Concentrations COHb Level % / Signs and Symptoms: 0 Usually none 10 Frontal headache 20 Throbbing headache, shortness of breath on exertion. 30 Impaired judgment, nausea, dizziness, visual disturbance, fatigue 40 Confusion, loss of consciousness 50 Coma, seizures 60 Hypotension, respiratory failure 70 Death Reference: CO Poisoning by Reisdorff & Wiegenstein / Emergency Medicine: A Comprehensive Study Guide 3rd Ed. New York McGraw Hill; 1992:704 3.14 Carboxyhemoglobin level is calculated by the following equation: Concentration Over a Time Period = Dose (How Much) (For) (How Long) = (How Bad) E.G.: 100 PPM CO over 90 Min. = 10% 3.15 The Occupational Safety and Health Administration has established a maximum safe working level for CO at 35 parts per million (p.p.m.) over an eight (8) hour period in the general work place. The U.S. Environmental Protection Agency (EPA) has established that residential levels are not to exceed 9 p.p.m. over an 8 hour average. 4. OPERATIONAL GUIDELINES 4.1 Operational Guidelines for Response to CO Detector Activation and CO Emergencies. 4.1.1 Are any individuals exhibiting symptoms of CO poisoning? If so immediately evacuate the affected area, ventilate, and request E.M.S. to respond. 4.1.2 Request the response of a company equipped with a CO meter if one is not already on the scene. 3

4.1.3 Using a CO meter, take an initial reading at the front door of premises, then continue investigation to find source of CO in premises. 4.1.4 If no one exhibits any symptoms of CO poisoning, evacuation is not necessary, unless a level of over 9 PPM is recorded by the meter. 4.1.5 The Incident Commander (IC) shall request the utility company to respond if: a. A CO level over 9 PPM is recorded by a meter. b. Units on the scene shut off a gas appliance. c. An individual(s) is exhibiting symptoms of CO poisoning. d. The IC feels a response by the utility company is required. 4.1.6 If the source of the CO is not found in the building, the origin may be in an attached exposure or from outside the building. 4.2 CO investigation will determine if the response is an Incident or an Emergency. 4.2.1 CO Incidents: No occupants are symptomatic and meter readings of 9PPM or less. 4.2.2 CO Emergencies: Occupants are symptomatic or meter readings greater than 9PPM 4.2.3 CO meter needed to test for a suspected CO presence. 4.2.4 CO meters are to be used according to manufacturer s instructions. 4.2.5 SCBA shall be worn at all CO investigations, and used at all CO Emergencies. 4.2.6 Search of the premises is to be conducted by a radio equipped team of a least two firefighters. 4.3 CO Incidents: Meter readings of 9 PPM or less: 4.3.1 Inform occupant that our meter has not detected an elevated CO level. 4.3.2 Attempt to reset detector, if detector does not reset or it does not have a reset, recommend that the occupant refer to the manufacturer s instructions. 4

4.3.3 Inform occupants that if detector activates again that they should again call 911 to notify the Fire Department. Note: The condition may have been caused by reverse stacking or a downdraft. Leaving a window open could eliminate the problem. 4.4 CO Emergency: Meter readings of greater than 9 PPM but less than 100 PPM: 4.4.1 Readings of greater than 9 PPM shall not be considered normal. 4.4.2 Inform occupants that they have a potentially dangerous level of CO. 4.4.3 Recommend that all persons leave the affected area and begin ventilation. 4.4.4 If it is determined that an appliance is malfunctioning and thereby producing CO, it should be shut down. 4.4.5 Once the faulty appliance is shut down and ventilation has reduced the CO level to 9 PPM or less the premises may be reoccupied. 4.4.6 Attempt to reset the detector as in section 4.3.2 4.4.7 Inform the occupant of all actions taken and that the utility company has been requested to respond. 4.4.8 Inform the occupant that if the detector activates again they should again notify the Fire Department by calling 911. 4.5 CO Emergency: Meter Readings of 100 PPM and Greater: 4.5.1 Inform occupants that we have detected a potentially lethal level of CO. 4.5.2 Begin evacuation of the affected area and ventilate. 4.5.3 If a malfunction appliance is found producing CO it should be shut down. 4.5.4 Once the source of CO has been mitigated and the level of CO reduced to 9 PPM or less the area may be reoccupied. 4.5.5 Attempt to reset the detector as in section 4.3.2. 5 Rev. 8/1/97

4.5.6 Inform occupants of the actions taken, and that the utility company has been requested to respond. 4.5.7 Inform occupants that if the detector activates again they should again notify the Fire Department by calling 911. 5. REPORTING (FIRE REPORT CODES, AND RADIO SIGNAL CODES) 5.1 In order to track Carbon Monoxide investigations the following procedures will be in effect: 5.1.1 The Incident Commander shall transmit the following Radio Code Signal: 10-38 Carbon Monoxide Response Any type of Carbon Monoxide Response Code 1: Detector Activation: Carbon Monoxide Investigation (low battery, defective detector, unwarranted alarm, etc.) Code 2: Detector Activation: Carbon Monoxide Incident (CO Meter Reading of 1-9ppm). Code 3: Detector Activation: Carbon Monoxide Emergency ( CO Meter Reading of greater than 9ppm). Code 4: No Detector Activation: Carbon Monoxide Incident or Emergency (Specify) e.g.: No detector present in affected area, detector present in affected area, but did not activate. 5.1.2. A BF-25A, BF-25B or BF-25 shall be utilized in accordance with AUC 210. Use fire report code number 28 (Defective Alarm Device) when transmitting 10-38- Code 1 and fire report code 18 (Leaks, Illum., Gas. Flam Vapor) when transmitting 10-38 Codes 2, 3 or 4. BY ORDER OF THE FIRE COMMISSIONER AND THE CHIEF OF DEPARTMENT 6 Rev. 8/1/97