Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

Installation & Operating Guide

Installation & Operating Guide

KIT NOTICE. These instructions are for replacing the two existing thermostats with a single new solid-state thermostat.

DRAIN WATER TEMPERING INSTALL

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

ELECTRIC FLAT PANEL FIREPLACE HEATER

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Operating Instructions

IMPORTANT SAFETY INSTRUCTIONS

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

Wall Mount Electric Fireplace

Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

Operator s Manual. Floor Vac Model No. VF408 FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Summer Breeze Heater Service Manual

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

K 3.97 M. Specifications or visit our website: In USA call: Part No

Viking Installation Guide

G-6c/GCG-6c. Instruction Manual. G-Series Cooler. Manual is for the following models: G-6-C23EB GCG-6-C23EB, G-6-CB23EB, GCG-6-CB23EB BEVERAGE COOLER

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal

IMPORTANT INSTRUCTIONS READ & SAVE

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

3.5-GALLON PARTS WASHER OWNER S MANUAL

Water Boilers ME10EN, ME15EN. Table of Contents

Floating Pond Pump System 1/2, 3/4 & 1 HP 230V Models FPS05021, FPS07021, FPS10021

IMPORTANT INSTRUCTIONS READ & SAVE

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

owner s manual & parts list

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

INFRARED ZONE HEATING SYSTEM

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

Wet/Dry Vacuum Kit

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

NO VENTING REQUIRED 120V AC;

8 lb Lightweight Vacuum Model CK LW 13/1

8TNR56XXXD-V1 Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 8TNR56XXXD-V1

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

INSTANT HOT WATER DISPENSER

M770 ph Controller Owner s Manual

INFRARED ZONE HEATING SYSTEM

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12

ELECTRIC FIREPLACE WITH MANTEL MODEL WS-Q-03 OWNERS MANUAL

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

ELECTRIC STOVE HEATER Models: FS2213B

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

Installation Instructions

Installation Manual CARBONATOR With Plain-Water Booster

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

Installation Instructions

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor 2kW RETHERMALIZER

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

GALAXY FLOOR MACHINE

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

PWC-500/1000/1010/1500

SOLO OWNERS MANUAL, OPERATING INSTRUCTIONS & INSTALLATION INSTRUCTIONS

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Model K 280 M Part No

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use.

Electrical Fireplace Stove with Heater

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

20-GALLON PARTS WASHER OWNER S MANUAL

STEAMPRO. Steam Generator Troubleshooting and Service Guide

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Food Waste Disposer Instruction Manual

Owner s Manual PS-50. Document Number: Revision: Draft

IMPORTANT SAFETY INFORMATION

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

ADD FLUID 300 NDNL 300 CT 300 OC 700 NDNL 725 NDNL 950 NDNL

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Transcription:

Introduction Before proceeding with the installation or operation of the Oil Alert System, read all instructions thoroughly, as well as complying with all Federal, State and Local codes, Regulations and Practices. The Oil Alert must be installed by qualified personnel familiar with all applicable local electrical and mechanical codes. Refer to the National Electrical Code (NFPA 70). Failure to properly install and test this product can result in personal injury or equipment malfunction. The Oil Alert control system is designed and approved for the safe operation of pumping, alarming and monitoring elevator sump pits, transformer vaults and leachate well applications. The Oil Alert will activate a pump to remove water from elevator pits in accordance with ASME A17.1. The Oil Alert stops the pump before oil or other harmful substances enter our water supply. Indicator lights will illuminate on the control panel for the following: power, pump running, high water, high oil and pump overload (optional). The panel has a set of auxiliary contacts that activate on power loss or high Oil/Water conditions. These contacts can be connected to the Oil Alert remote panel which contains audio/visual alarming along with auxiliary contacts for connection to building automation system or SCADA system. Safety Guidelines 1. DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KERO- SENE, ETC. DO NOT USE IN EXPLOSIVE AOSPHERES. PROBE/FLOAT SWITCH SHOULD ONLY BE USED WITH WATER. 2. DO NOT HANDLE THE OIL ALERT SYSTEM WITH WET HANDS OR WHEN STANDING ON A WET OR DAMP SURFACE OR IN WATER. 3. DISCONNECT ALL ELECTRICAL SERVICE BEFORE WORKING OR HANDLING THE OIL ALERT SYSTEM. 4. INCOMING VOLTAGE MUST MATCH OIL ALERT SYSTEM VOLTAGE. 5. TO PREVENT ELECTICAL SHOCK AND EQUIPMENT MALFUNCTION, USE ONLY WITH A PUMP SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUNDING-TYPE ATTACHMENT PLUG. BE CERTAIN TO PLUG THE OIL ALERT PANEL TO A PROPERLY GROUNDED, GROUNDING-TYPE RECEPTACLE. 6. CONTROL PANEL AND ALARM MUST BE MOUNTED INDOORS. FOR OUTDOOR APPLICATIONS CONSULT FACTORY. 7. USE CAUTION WITH MODELS USING AN OVERLOAD RELAY. PUMP MOTOR MAY START IMMEDIA- TELY WHEN OVERLOAD IS RESET. 8. SECURE LEVEL SENSOR ON DISCHARGE PIPE AT A LEVEL THAT GUARANTEES PARTIAL PUMP SUBMERGENCE WHEN WATER LEVEL IS JUST BELOW THE OFF PROBE (THE LONGEST PROBE / See Figures 4 and 5 on Page 3 of this manual). FAILURE TO PROPERLY MOUNT THE LEVEL SENSOR MAY CAUSE THE PUMP TO ACTIVATE EVEN WHEN OIL IS PRESENT IN THE SUMP. 9. CAUTION! REMOVE ANY FLOAT SWITCH THAT IS CURRENTLY USED OR SUPPLIED WITH THE PUMP. IF THE FLOAT CANNOT BE REMOVED, SECURE SWITCH SO THAT IT IS ALWAYS ON. Important REFER TO THE INCLUDED ELECTRICAL SCHEMATIC FOR ALL INCOMING POWER CONNECTIONS AND PUMP CONNECTIONS WHICH MAY INCLUDE OPTIONAL FIELD WIRING CONNECTIONS Alarm Systems Control Panels Float Switches Leak Detection Systems PN: 101445 Page 1 of 9

Alarm Oil Alert Description of Operation On water rise, level reaches pump start probe to start the pump. Pump will remain on until level is below off probe. The off probe senses air or oil and turns the pump off so the oil layer will not be pumped out of the sump. If the liquid level reaches alarm probe and mechanical float, the system will differentiate between water and oil and activate the remote alarm. Installation of the Control Panel 1. Review figures 1, 2 and 3. 2. Determine mounting location for the control panel. 3. For models with overload relay or motor protective switch, set dial to full load amps (FLA) of the pump (Fig. 3). 4. Connect pump cable into control panel. Connect power cable into control panel only when ready for testing. See Testing System installation on Page 8. (Fig. 1) Remote Alarm has additional auxiliary contacts for building alarm system. Control Panel (Fig. 2) Three Phase Models: Set transformer to match incoming voltage. 460 230 208 0 H1 H2 H3 H4 120 V Receptacle X2 N/A XF X1 Elevator Sump 2 Sensor Conduit 2 Power Conduit (Fig. 3) Adjusting the Overload Relay and MPS Switch Single Phase: Overload (if applicable) A1 A2 Three Phase: Set Dial to Full Load Amps of the pump High Water Level Oil Film Detection Level Pump On Level 1 L1 3 L2 5 L3 13 NO Pump Off Level T2 6 2 T1 T3 4 14 NO Reset 13 10 16 7 4 3.2 Warning Do not mix high and low voltage circuits in the same conduit, failure to do so will cause system malfunction. KEEP THE SENSOR CONDUIT AND POWER CONDUIT 2 INCHES APART. The Preset Level Sensor and Auxiliary Contact wires are low voltage class 2 circuits - Do not install sensor cables in conduits with main power or pump cables. Reset 10 13 16 7 4 3.2 Alarm Systems Control Panels Float Switches Leak Detection Systems PN: 101445 Page 2 of 9

Installation of Preset Level Sensor Holder 1. Review figures 4, 5 and 6. 2. Attach sensor holder to discharge pipe or separate pipe (mounted to side wall) using the stainless steel pipe clamp. Make sure sensor is clear of inlet water and at least 2 inches away from any conductive material. Make sure the bottom probe (off level) is at the same height as the top of the pump or just slightly below ensuring submergence of the pump (Fig. 5). 3. Route the five conductor cable to the control panel through the liquid tight cord connector and tighten compression nut. 4. Connect the wires from the level sensor to the terminal strip inside the control panel (Fig. 6). 5. If splicing on sensor cable is required: A. For any splicing longer than 100 feet, consult factory. B. Use liquid tight junction boxes and appropriate liquid tight connectors and/or conduit. C. Do not mix high and low voltage circuits in same junction box. D. For level sensor splice, it is recommended to use 3 pair-twisted. High Level Float (Fig. 4) Preset Level Sensor Holder (Fig. 6) Circuit Board High Level Pump Start Off (Fig. 5) Discharge Pipe Mount Side Wall Mount Green Off Yellow Start Red Alarm White Float Black Sheild Common Oil Water Overload Trip (Optional) Float Auxiliary Contacts 24 VAC/VDC 100 ma Max Conect to Remote Alarm Or BAS/SCADA System 5 Conductor Cable from Preset Level Sensor Preset Level Sensor Alarm Systems Control Panels Float Switches Leak Detection Systems PN: 101445 Page 3 of 9

Installation of the Remote Alarm Panel Before proceeding with the installation or operation of the Oil Alert Remote Alarm, read all instructions thoroughly, as well as complying with all Federal, State and Local Codes, Regulations and Practices. The Oil Alert Remote Alarm must be installed by qualified personnel familiar with all applicable local electrical and mechanical codes. Refer to National Electrical Code (NFPA 70). Failure to properly install and test this product can result in personal injury or equipment malfunction. Safety Guidelines 1. DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC. DO NOT USE IN EXPLOSIVE AOSPHERES. 2. REMOTE ALARM MUST BE MOUNTED INDOORS. FOR OUTDOOR APPLICATIONS CONSULT FACTORY. Description of Operation The Oil Alert Remote Alarm is powered by 120 VAC coming from standard wall outlets and is transformed to 9-11 VDC. Installing a 9 Volt battery provides battery backup. The Oil Alert Remote Alarm activates on High Oil, High Water or (Optional) Pump Overload from the control panel. Separate dry contacts for High Oil, High Water and (Optional) Pump Overload can be connectd to an Auto Dialer, a BAS (building automation system) or SCADA system. Tools, Supplies and Requirements for Installation (Not Included) 1. Phillips screw driver 2. (Qty 2) #6 self tapping screws 3. Access to 120 VAC power receptacle 4. Optional - Plastic anchor if mounting to sheet rock 5. Optional - 9V battery (used for battery backup if power goes out) 6. Optional - Wire stripper (used if you need to strip wire to connect to a BAS or SCADA system) 7. Optional - Needle nose pliers if using auxiliary contacts Alarm Systems Control Panels Float Switches Leak Detection Systems PN: 101445 Page 4 of 9

Oil Alert Installation of the Remote Alarm Panel Continued 1. To install/replace the battery for the backup power feature, remove the access cover (Fig. 7) and install 9 VDC battery (Duracell model MX 1604B2) (Fig. 8). After installing battery, press the test button (Fig. 9) to activate the alarm to make sure the battery works properly. The power on, high oil, high water an pump overload lights should illuminate and the buzzer should annunciate. If using the auxiliary contacts, leave cover off until Step 3 is completed. If you are not using the auxiliary contacts, replace the access cover (Fig. 10). (Fig. 7) (Fig. 8) (Fig. 9) (Fig. 10) 2. Determine mounting location for the Oil Alert Remote Alarm. Make sure power outlet is within 5 feet of the alarm (Fig. 11). Make sure the outlet is on a separate circuit breaker from any other device and not on a switched receptacle to maintain power integrity. Mount the alarm using two #6 self tapping screws (not included) (Fig. 12). Use #8 plastic anchor (not included) if mounting to sheet rock (Fig. 13). 5 ft max (Fig. 11) (Fig. 12) (Fig. 13) Alarm Systems Control Panels Float Switches Leak Detection Systems PN: 101445 Page 5 of 9

Installation of the Remote Alarm Panel Continued 3. If connecting to existing alarm security system or (BAS) system leave terminals + and - open and use 18 AWG 4 conductor wire to connect the existing product to terminals. When connected, replace the access cover and pull the wire through the knockouts on the access cover (see Step 4). Caution! - When installing wires, route all wires away from sharp objects and internal components. Models without Pump Overload Models with Pump Overload + - 2A 2B 1A 1B + - RC 3A 2A 1A + - 2A 2B 1A 1B + - RC 3A 2A 1A Terminals + and - Do Not Use Terminals 2A & 2B High Oil Terminals 1A & 1B High Water Class 2, 24 VDC/VAC (50/60 HZ) 100 Milliamps MAXIMUM Terminals + and - Do Not Use Terminals RC & 1A High Oil Terminals RC & 2A High Water Terminals RC & 3A Pump Overload Class 2, 24 VDC/VAC (50/60 HZ) 100 Milliamps MAXIMUM NOTE: The Auxiliary Contacts on the Oil Alert Remote Alarm are Normally Open only. 4. Use a needle nose pliers (not included) to remove the desired break away tabs from the access cover, lightly pull and twist off tab(s) (Fig. 14). Run the wires through the knockouts when replacing the access cover (Fig. 15). (Fig. 14) (Fig. 115) 2 3 4 Alarm Systems Control Panels Float Switches Leak Detection Systems PN: 101445 Page 6 of 9

Installation of the Remote Alarm Panel Continued 5. Connect the Oil Alert Remote Alarm to the auxiliary contacts marked COW (Models without Pump Overload) or COWT (Models with Pump Overload) in the control panel. Use 18 AWG cable. CAUTION: The auxiliary contacts are low voltage wires and can not be run in a conduit with high voltage wires. Models without Pump Overload Models with Pump Overload O W Connects To Auxiliary Contacts In Panel O W T Connects To Auxiliary Contacts In Panel 6. Plug in the power supply into a 120VAC, 50/60 HZ standard wall outlet. The green Power On light should come on. 5 ft max 7. Test the system by pressing the Alarm Test button. The buzzer, the red High Water, High Oil and (Optional) Pump Overload lights will be on. Release the Alarm Test button, the alarm buzzer and indicator lights will automatically reset. Test product weekly to ensure system integrity. Alarm Systems Control Panels Float Switches Leak Detection Systems PN: 101445 Page 7 of 9

Testing the complete system Upon complete installation of controls, pump and piping, test the complete system (place switches in Auto mode). 1. Test high oil circuit by lifting the float switch with the sump empty of water. Oil is non conductive like air and when the float is lifted only the HIGH OIL indicator will be illuminated. The auxiliary contacts in the control panel and the remote alarm will activate. 2. Test a pump cycle by slowly filling tank with water. Stop filling tank with water when the level touches middle probe. When the water touches the middle probe, the pump should start and pump down to the bottom probe at which time the pump will stop. Check discharge plumbing for leaks and make sure discharge is going to the correct area. If testing a Duplex system, pumps will alternate on each cycle. 3. Test high water circuit. Slowly fill the tank until the water level just touches the upper probe. When the water touches all probes, the HIGH WATER indicator will be illuminated. The auxiliary contacts in the control panel and the remote alarm will activate. For Duplex models, Lag pump will also start. 4. Test the remote alarm for power loss. Disconnect power to the control panel. The auxiliary contacts C and W will close and the remote alarm will activate. Testing Panel - Using 5 gallon pail If it is not possible to test the complete system outlined above, then test the panel operation using a 5 gallon pail filled with water. 1. Before lowering the sensor probe into the pail, lift the float switch, the HIGH OIL indicator (Fig. 20) will be illuminated. The auxiliary contacts in the control panel and the remote alarm will activate for oil alarm. 2. Press down and hold the tact switch on the circuit board (Fig. 16) while lowering the sensor into the bucket so the bottom and middle probes touch the water (Fig. 17), the pump should activate. While the pump is activated, slowly remove the sensor probe out of the water until the longest probe is no longer in the water (Fig. 18), then let go of the tact switch (Fig. 16) and the pump should turn off. Repeat a couple of times for quality assurance. 3. Press down and hold the tact switch on the circuit board (Fig. 16) while lowering the sensor probe into the bucket of water slowly so that the longest probe and the middle probe are immersed in water (Fig. 17) the pump will activate. Continue to lower sensor probe so that water touches the shortest probe (Fig. 19), the HIGH WATER indicator will be illuminated (Fig. 21). The auxiliary contacts in the control panel and the remote alarm will activate. (Fig. 20) (Fig. 21) (Fig. 16) (Fig. 17) (Fig. 18) (Fig. 19) Alarm Systems Control Panels Float Switches Leak Detection Systems PN: 101445 Page 8 of 9

Maintenance 1. The preset level control must be kept clean and free of rust, mud, soap or any conductive material. 2. Every year clean probes keeping them free of debris, calcium or iron deposits. 3. Fuses in control panel are 5mm x 20mm 1/2amp for F1 and 5mm x 20mm 1amp for F2. (Spare fuses are included for you convenience) 4. Every year replace 9 Volt battery in remote alarm. Trouble Shooting Symptom Possible Cause Action Pump does not run Panel power cord unplugged Plug in outlet, check power Pump not plugged into panel Plug pump to panel plug Defective contactor Replace contactor Loose level sensor wires Tighten connections Pump failure Replace pump Pump turns off before Poor pump ground or system ground Check grounding system bottom probe Pump runs continuously Make sure the preset level sensor cable and the power cord from the pump are separated by at least 2 in the tank and 2 apart above ground Alarm Systems Control Panels Float Switches Leak Detection Systems PN: 101445 Page 9 of 9