ACDU02 Communicating Service Tool

Similar documents
ATC32U02 igate Communicating, Programmable Thermostat

ATC32U01 igate Communicating, Programmable Thermostat

ATC32U01A Communicating, Programmable Thermostat

Tranquility Digital Quick Start Guide

Tranquility Digital Quick Start Guide

ATC32U01 igate Communicating, Programmable Thermostat

ATC32U03 igate Communicating, Programmable Thermostat

DXM2 Digital Heat Pump Controller

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

ClimaDry II. Table of Contents. ClimaDry II Whole House Dehumidification Option. Tranquility 30 Tranquility 20

Auxiliary Electric Heater Interface kit ASKHTR

BasicTroubleshooting Information and Guidelines

THE TRANQUILITY 16 COMPACT (TC) SERIES

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

Tranquility Digital (DXM2) Troubleshooting Guide

AG Series Electric Heaters

AHWG Remote Mount Hot Water Generator Module for TTP Series Outdoor Split Unit

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

igate ClimaZone Zoning Panel

*IG1583EW* Aurora Touch UPC Kit Instruction Guide. Aurora Touch UPC Kit Instruction Guide

AG Series Electric Heaters

Tranquility Vertical Stack (TSL) Series

ATC32U01 Basic Operation Guide

AHWG Remote Mount Hot Water Generator Module

Tranquility Vertical Stack (TSM) Series

Tranquility Digital Air Handler (TAH)

Tranquility Vertical Stack (TSM) Series Submittal Data

Application, Operation and Maintenance Guide. DXM Electronic Heat Pump Control

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

Pioneer Gold Controller Technical Guide. Pioneer Gold Controller Code: Version 1.1 Used with AAON WSHP WV Series Vertical and WH Series Horizontal

TRANQUILITY WATER-TO-WATER SERIES

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

Technology Applied. IGSHPA Conference

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

RSMV Technical Guide

Installation and Maintenance Manual OM

Pioneer Gold Controller Technical Guide

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

SPECIFICATION CATALOG. Console 0.75 to 1.5 Tons. Geothermal/Water Source Heat Pump

Tranquility 22 Digital (TZ) Series IOM

Advanced Installation and Configuration Instructions

Split Products. Indoor (TES) Series. Tranquility Digital Split. Outdoor (TEP) Series. Indoor and Outdoor Split Geothermal Heat Pumps

ECM OPERATION MANUAL

Instruction Guide: Thermostat Operation

HPC. Heat Pump Controller. Installation, Operation, and Maintenance Manual (2019/02)

1.0 Digital Controller

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

GT-X. 50YBV Ultra High Efficiency Vertical Two-Stage Geothermal System. Installation, Operation & Maintenance Instructions TABLE OF CONTENTS


CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

Commercial Thermostat

1.0 Digital Controller

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

INSTALLER'S SYSTEM SETUP GUIDE NOTICE

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

RCS Residential Control Systems Inc.

RESIDENTIAL PRODUCT GUIDE CLIMATEMASTER GEOTHERMAL HEATING & COOLING DECLARE YOUR PERSONAL ENERGY INDEPENDENCE

ASTON CONSOLE SERIES

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Tranquility 30 Digital (TE) Series IOM

Water Source Heat Pump Module Technical Guide

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

Factory Packaged Controls. MHGRV-X Controller Field Technical Guide

DCU 305 R2/R3. Troubleshooting Manual

DOAS CM3500 Controller

*20D082-05NN* 20D082-05NN


1F98EZ-1421, Easy Install

WARNING IMPORTANT. iharmony Zoning System CONTROLS KITS AND ACCESSORIES. Installation Instructions for the iharmony Zoning System (10C16)

Ultra Classic (VT) Series Residential Vertical Two-Stage Geothermal Heat Pumps

TWLC - Tempered Water Logic Controller. The Intelligent Control

Tranquility (THW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES Hz [10 kw]

Installation and Start-Up Instructions

Commercial and Residential Water Source Heat Pumps Boiler/Tower and Geothermal Applications

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Commercial Thermostat Submittal Data

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

I/O ZONE 560/583 USERS GUIDE

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

RPM1600 Series Room Pressure Monitors

NEW CHILLER SCHEDULE

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

Field Application of Advanced Residential Air Conditioning Systems

Comfort Control 2 HD Thermostat

1F95EZ-0671 Non-Programmable 7 Day. Maximum Stages Heat/Cool 1/1 2/2 3/1 4/2

SPECIFICATION CATALOG. Commercial 0.75 to 6 Tons. Geothermal/Water Source Heat Pump

CONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

Trinity Tft/Lx Model #s: Tft60-399/Lx Version Date:

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

INSTALLATION, OPERATION & QUICK START GUIDE

SPECIFICATION CATALOG. Commercial 7 to 25 Tons. Geothermal/Water Source Heat Pump

Operation and Maintenance Manual OM MicroTech III Unit Controller with I/O Expansion Module for Two Compressor Water Source Heat Pumps

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

EL-TSTAT-8820 Safety & Installation Instructions

VT8300 Series Installation Guide 24 Vac Low Voltage

WSK300 Multifunction Wall Control

Transcription:

ACDU02 Communicating Service Tool Operation Manual 97B0106N01 Rev.: 4/17/14 Caution: These instructions are intended to be used by the installer or service personnel. End users are NOT advised to change or modify any of these settings. Doing so may cause the equipment to stop working properly and/or may void the warranty on both the thermostat and the equipment. Table of Contents Section Title Page 1.0 Connection 3 2.0 Menu Structure 4 3.0 System Confi guration 4 3.1 Airflow Selection 4 3.2 Option Selection 5 3.3 Unit Configuration 5 3.4 Pump Configuration 6 3.5 Valve Configuration 6 3.6 Multi-Unit Confi guration 7 4.0 Service Mode 8 4.1 Manual Operation 8 4.2 Control Diagnostics 8 4.3 Dipswitch Confi guration 9 4.4 Fault History 9 4.5 Clear Fault History 11 5.0 Revision History 12

This page was intentionally left blank.

1.0 Connection ClimateMaster s Communicating Service Tool (ACDU02) allows install and service technicians to confi gure and diagnose ClimateMaster Digital Communicating Units without installing a digital communicating thermostat. Using the Service Tool, a technician can ELECTRONICALLY: 1. Confi gure items like: airfl ow, heat pump options and confi guration, pump or modulating valve operation, unit family, unit size, etc. AND 2. Diagnose the unit by operating it manually, performing control diagnostics, viewing dip switch confi gurations, or by viewing fault history and operating conditions when a fault occurred. The Service Tool connects to the DXM2 board with a 4-Wire Connector as shown below: Note: For Vertical Stack models (TSM, TSL) must order 11B0100N26 Harness for connection to service port outside chassis. DXM2 to service port is factory wired. DXM2 Board P1 Y1 Y2 W O G R C AL1 P2 AL2 R NSB C Alarm R JW1 Gnd B- A+ 24V P5 DXM2 Board Service tool connection WARNING! WARNING! Connecting wire harness while unit is powered on or connecting backward may damage service tool. 3

2.0 Menu Structure Menu Structure System Confi guration Airflow Selection Option Selection Unit Confi guration Pump Confi guration Valve Confi guration Service Mode Manual Operation Control Diagnostics Dipswitch Confi guration Fault History Clear Fault History 3.0 System Configuration SYSTEM CONFIG SERVICE MODE SERVICE TOOL MENU Use the System Confi guration option on the start-up screen to adjust critical equipment settings. The System Confi guration information will be automatically obtained from each communicating control in the system. Note 1: The Airfl ow Selection menu (section 3.1) will not be present if the connected communicating control system has no blower. Note 2: The Pump Confi guration menu (section 3.4) will not be present if the connected communicating control is confi gured for No Loop Confi guration (OTHER). Note 3: The Valve Confi guration menu (section 3.5) will not be present if the connected communicating control is confi gured for No Loop Confi guration (OTHER). ACDU02 1.00 OPTION Start-up Screen SYSTEM CONFIGURATION AIRFLOW ION OPTION ION UNIT CONFIG PUMP CONFIGURATION TES026 3.1 AIRFLOW ION Adjust the airfl ow settings for each system operating mode using the up/down arrow buttons. Press the center button to select each item. Airfl ow Settings (defaults stored in control) - valid range: obtained from control (in 25 CFM increments) Blower Off Delay (default 60 seconds) valid range: 0 to 255 seconds (in 5 second increments) NOTE 1: The Airfl ow Settings will only be present if the connected communicating control is confi gured for ECM blower. NOTE 2: If multiple units are connected to one thermostat, refer to section 3.6 for unit selection. OPTION System Configuration Menu 4 Geothermal Heat Pump Systems

3.2 OPTION ION This option allows the confi guration of heat pump options to be modified. Adjust the Option settings using the up/down arrow buttons. Press the center button to select each item. Motorized Valve (defaults stored in control) valid range: Off, On On delays compressor start until the valve is fully open. Compressor ASCD (Anti-Short Cycle Delay (default stored in control) valid range: 5 to 8 (in 1 minute increments) NOTE 1: The Compressor Anti-Short Cycle Delay setting provides equipment protection by forcing the compressor to wait a few minutes before restarting. Option Selection Menu OPTION ION MOTORIZED VALVE COMPRESSOR ASCD 0 OPTION NOTE 2: If multiple units are connected to one thermostat, refer to section 3.6 for unit selection. NOTE: Motorized Valve used here refers to a two-position motorized water valve, not to be confused with the modulating motorized water valve found in the LOOP CONFIG. 3.3 UNIT CONFIGURATION Adjust the Unit Confi guration settings including Heat Pump Family, Heat Pump Size, Blower Type, and Loop Confi guration using the up/down arrow buttons. Press the center button to select each item. Heat Pump Family (default stored in control) valid range: TE, TY, TES, TEP, TRT, TSM, TSL Heat Pump Size (default stored in control) valid range: depends on Heat Pump Family setting Blower Type (default stored in control) valid range: NONE, PSC 2SPD, ECM, PSC 1SPD Loop Confi g (default stored in control) valid range: Other, VS PUMP, MOD VALVE Airfl ow, pump and valves can be confi gured from System Configuration screen. UNIT CONFIGURATION CURRENT CONFIG TE026 HEAT PUMP FAMILY TE HEAT PUMP SIZE 026 BLOWER TYPE ECM LOOP CONFIG VS PUMP OPTION Unit Configuration Menu SAVE Select VS PUMP PARALLEL when applying an internal variable speed fl ow controller with other fl ow controllers on a single loop in parallel. NOTE: Refer to section 3.6.3 for multi-unit confi guration instructions. 5

3.4 PUMP CONFIGURATION vflow vs internal fl ow control pump can be controlled either through temperature differential (Delta T) or can be set to specifi c speed (fi xed; % of full speed for each heat and cool stage). Can be confi gured for either single pumping or parallel pumping. Confi gure temperature differentials at the thermostat for vflow units with an internal fl ow control pump. Adjust the Pump Confi guration settings using the up/down arrow buttons. Press the center button to select each item. Heating Delta T (default stored in control) valid range: 4 to 12ºF (in 1ºF increments) Cooling Delta T (default stored in control) valid range: 9 to 20ºF (in 1ºF increments) Maximum Heat LWT (valid range based on specifi c model; refer to model IOM). Minimum Cool LWT (valid range based on specifi c model; refer to model IOM). NOTE: Refer to section 3.6.3 for multi-unit confi guration instructions. LOOP OPTION PUMP CONTROL HEATING DELTA T COOLING DELTA T LOOP OPTION PUMP CONTROL VARIABLE SPD INTERNAL PUMP CONFIGURATION SINGLE FIXED HEATING STAGE 1 60% COOLING STAGE 2 75% COOLING STAGE 1 50% COOLING STAGE 2 70% VARIABLE SPD INTERNAL PUMP CONFIGURATION MAXIMUM HEAT LWT MINIMUM COOL LWT PARALLEL DELTA T 7 F 10 F 80 F 40 F To control vs pump by fi xed speed, select Pump Control, press, use down arrow to select Fixed, and press to save. Default stored in control. Valid range: 15% - 90% (in 1% increments) Heating Stage 1 Cooling Stage 1 Heating Stage 2 Cooling Stage 2 If Pump Confi guration is set to VS PUMP PARALLEL, valid range changes to 50-90% (in 1% increments). 3.5 VALVE CONFIGURATION Confi gure temperature differentials at the thermostat for vflow units with a motorized modulating valve. Adjust the Valve Confi guration settings using the up/down arrow buttons. Press the center button to select each item. Heating Delta T (default stored in control) valid range: 4 to 12ºF (in 1ºF increments) Cooling Delta T (default stored in control) valid range: 9 to 20ºF (in 1ºF increments) NOTE 1: Minimum and Maximum degree values are shown only when the control is confi gured with the appropriate values. MODULATING VALVE CONFIGURATION POSITION 0.0 VALVE CONTROL DELTA T HEATING DELTA T COOLING DELTA T 7 F 10 F MAXIMUM HEAT LWT MINIMUM COOL LWT 80 F 40 F NOTE 2: Refer to section 3.6.3 for multi-unit confi guration instructions. 3.5.1 MODULATING VALVE POSITION For certain commercial multi-unit applications, the modulating valve can be kept slightly open by choosing values 3.3-4.0. 6 Geothermal Heat Pump Systems

3.6 MULTI-UNIT CONFIGURATION If multiple units are connected to one ATC thermostat upon unit start-up, the thermostat will automatically register the serial numbers of all units connected to it. NOTE: Multiple units may be connected directly to the ATC thermostat or connected to one another in series, as shown by the fi gure below. 3.6.1 MULTI-UNIT AIRFLOW ION In section 3.1, when an installer selects Airfl ow Selection from the System Confi guration menu, the installer may choose the unit to confi gure by the last 4 digits of its serial number from the following screen. Or 3.6.2 MULTI-UNIT OPTION ION In section 3.2, when an installer selects Option Selection from the System Confi guration menu, the installer may choose the unit to confi gure by the last 4 digits of its serial number from the following screen. 3.6.3 Multi-Unit, Unit, Pump, & Valve Configuration To confi gure Unit, Pump, and Valve options in sections 3.3-3.5, the thermostat must be connected to only one unit at a time. Two connections on DXM2 board to allow for multi-unit installation AIRFLOW ION TT026 S N - - - - - 1 2 3 4 TT026 S N - - - - - 5 6 7 8 TT038 S N - - - - - 9 0 1 2 OPTION ION TT026 S N - - - - - 1 2 3 4 TT026 S N - - - - - 5 6 7 8 TT038 S N - - - - - 9 0 1 2 7

4.0 Service Mode 4.1 MANUAL OPERATION Manual Operation mode allows service personnel to manually command operation for any of the thermostat outputs, blower speed, as well as pump speed or valve position to help troubleshoot specific components. NOTE 1: The ECM Airflow adjustment will not be present if the connected communicating control (DXM2) is not configured for ECM (section 3.1). NOTE 2: The Pump Speed adjustment will not be present if the connected communicating control (DXM2) is not configured for Pump (section 3.4). NOTE 3: The Valve Position adjustment will not be present if the connected communicating control (DXM2) is configured for Valve (section 3.5). 4.2 CONTROL DIAGNOSTICS Control Diagnostics mode allows service personnel to view the status of all physical inputs, switches and temperature sensor readings, as well as the operational status of the heat pump at the thermostat. Navigate between diagnostic screens using the left/right arrow buttons. NOTE: The Pump Status will not be present if the connected communicating control (DXM2) is not configured for Pump (section 3.4). SERVICE MODE MANUAL OPERATION CONTROL DIAGNOSTICS DIPSWITCH CONFIG FAULT HISTORY CLEAR FAULT HISTORY OPTION MANUAL OPERATING MODE Y1 COMM OUTPUT Y2 COMM OUTPUT W COMM OUTPUT O COMM OUTPUT G COMM OUTPUT H COMM OUTPUT DH COMM OUTPUT ECM AIRFLOW 0 PUMP SPEED 0% TEST MODE OPTION CONTROL DIAGNOSTICS HP SWITCH CL LOC SWITCH CL Y1 PHYSICAL INPUT ON Y2 PHYSICAL INPUT W PHYSICAL INPUT O PHYSICAL INPUT ON G PHYSICAL INPUT ON H PHYSICAL INPUT EMERG SHUTDOWN NIGHT SETBACK OVR INPUT NEXT CONTROL STATUS TEMPERATURES LT1 TEMP 38.1 LT2 TEMP 79.9 COMP DISCHARGE 157.7 HOT WATER EWT 121.5 LEAVING AIR 75.1 LEAVING WATER 73.3 ENTERING WATER 78.5 CONTROL VOLTAGE 26.4 ECM BLOWER RPM 550 ECM TARGET CFM 800 ECM BLWR STATIC N/A CONTROL DIAGNOSTICS PUMP OPERATION NEXT PUMP SPEED 60% PUMP WATTS 140 FLOW RATE GPM 7.4 8 Geothermal Heat Pump Systems

4.3 DIPSWITCH CONFIGURATION Dipswitch Confi guration mode allows the service personnel to view the status of all dipswitch settings for the connected communicating control (DXM2/AXM) at the thermostat. Navigate between confi guration screens using the left/right arrow buttons. NOTE: The unit control dipswitch settings cannot be changed from the thermostat or configuration/diagnostics tool. CONTROL CONFIGURATION DIPSWITCH S1 1 ON UPS ENABLED 2 ON DUAL COMP STG 1 3 ON HEAT PUMP TSTAT 4 ON RV O THERMOSTAT 5 ON DEHUMID 6 ON EH2 AUX HEAT 7 ON BOILERLESS 8 ON SEE DXM2 AOM S1 Dipswitch Status CONTROL CONFIGURATION DIPSWITCH S2 1 ON \ ACCESSORY 1 2 ON ACCESSORY 2 3 ON/ NEXT 4 ON \ ACCESSORY 2 5 ON ACTIVE W/ COMP 6 ON / 7 ON H DEHUM INPUT 8 ON FACTORY SETTING S2 Dipswitch Status CONTROL CONFIGURATION DIPSWITCH S3 1 ON FACTORY SETTING 2 HWG TEST 3 HWG SP 125 4 HWG DISABLED JW3 LT1 SETTING WELL NEXT S3 Dipswitch Status 4.4 FAULT HISTORY Fault History mode displays the fi ve most recent stored fault codes for the connected communicating control (DXM2). Navigate between control fault codes using the up/down arrow buttons. Press the center button to view more information about the highlighted fault code. TT038 SN - - - - - 0 1 2 3 LAST 5 FAULTS LT1 LOW WATER TEMP NO FAULT NO FAULT NO FAULT NO FAULT NEXT Fault History 9

4.4.0 Fault Conditions Menu 4.4.1 Temperature Conditions Displays detailed temperature readings that were recorded at the time the fault occurred 4.4.2 Flow Conditions Displays detailed blower and pump speed / valve position readings that were recorded at the time the fault occurred. FAULT CONDITION MENU LT1 LOW WATER TEMP HEAT 1 11:11 AM 11/14 FAULT TEMP CONDITIONS FAULT FLOW CONDITIONS FAULT I/O CONDITIONS FAULT CONFIG COND FAULT POSSIBLE CAUSES FAULT TEMPERATURE CONDITIONS LT1 LOW WATER TEMP HEAT 1 11:11 AM 11/14 LT1 TEMP 28.1 LT2 TEMP 97.3 HOT WATER EWT 121.5 COMP DISCHARGE 157.7 LEAVING AIR 92.7 LEAVING WATER 34.9 ENTERING WATER 42.1 CONTROL VOLTAGE 26.4 FAULT FLOW CONDITIONS LT1 LOW WATER TEMP HEAT 1 11:11 AM 11/14 ECM TARGET CFM 800 ECM BLOWER RPM 550 FLOW RATE GPM 6.5 PUMP SPEED 60% PUMP WATTS 140 LOOP CONFIG VS PUMP SINGLE FAULT FLOW CONDITIONS LT1 LOW WATER TEMP HEAT 1 11:11 AM 11/14 ECM TARGET CFM 800 ECM BLOWER RPM 550 VALVE POSITION 10.0V LOOP CONFIG 4.4.3 Input/Output Conditions FAULT I / O CONDITIONS Displays the status of all physical and communicated LT1 LOW WATER TEMP inputs, switches, and control outputs that were recorded at the time the fault occurred. HEAT 1 11:11 AM 11/14 TSTAT SAFETY OUTPT CONV COMM HPS Y1 Y1 LOC CC Y2 Y2 CO RV W W ACC1 O O OUTPT ACC2 G G FAN AL1 H H HWG EH1 OVR DH PUMP EH2 10 Geothermal Heat Pump Systems MOD VALVE MIN POS

4.4.3 Configuration Conditions Displays the status of all dipswitch settings that were recorded at the time the fault occurred. 4.4.4 Possible Causes Displays possible causes as to why the fault occurred FAULT CONFG CONDITIONS LT1 LOW WATER TEMP HEAT 1 11:11 AM 11/14 S1 S2 S3 1 ON 1 ON 1 ON 2 ON 2 ON 2 3 ON 3 ON 3 4 ON 4 ON 4 5 ON 5 ON 6 ON 6 ON LT1 WELL 7 ON 7 ON LT2 WELL 8 ON 8 ON POSSIBLE FAULT CAUSES LOW WATER COIL TEMP LOW WATER TEMP - HTG LOW WATER FLOW - HTG LOW REFRIG CHARGE - HTG INCORRECT LT1 SETTING BAD LT1 THERMISTOR 4.5 CLEAR FAULT HISTORY Clear Fault History will clear all fault codes stored in the thermostat as well as the fault history in any connected communicating controls (DXM2/AXM). 11

MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ACDU02 Communicating Service Tool 5.0 Revision History Date Page # Description 17 Apr., 14 3,5 Text 11 Feb., 14 All ACDU01 Updated to ACDU02 23 Oct. 12 4-7 Unit Confi g, Pump Confi g and Valve Confi g Sections Updated 8 May, 12 All First Published ISO WATER TO AIR HEAT R PUMPS STANDARD BRINE TO AIR 13256-1 *97B0106N01* 97B0106N01 ISO 9001:2008 Certified Quality: First & Always 7300 S.W. 44th Street Oklahoma City, OK 73179 Phone: 405-745-6000 Fax: 405-745-6058 climatemaster.com ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster s opinion or commendation of its products. The management system governing the manufacture of ClimateMaster s products is ISO 9001:2008 certified. ClimateMaster, Inc. 2012 12 Geothermal Heat Pump Systems