P ro d u c t C ata l o g u e J a n ua ry Energy Saving Security Convenience

Similar documents
PIR OCCUPANCY SWITCHES

Energy Saving Security Convenience. Product Catalogue

CONTROLS FOR DALI DIMMABLE BALLASTS

Leading edge rotary / rotary & push dimmers

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Programmable multi-functional energy saving lighting control. Easy to install and commission

LPCMPIRM65 & LPCMPIRDSI65

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

, ,

Sensors and Detectors

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

LPC3BSP65 & LPC3BDP65

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

FR-A180 FR-A360. Occupancy detector. Use

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Integrated PIR detectors

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

SENSA MRE DDM MR

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Data sheet. Function description. Benefits

False Ceiling HF Sensors

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

EBMHS (standard & slim-line PSU)

Direct Dim Microwave Presence/Absence Detector

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Tri-level Control Sensor

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

The Power To Supply... All Your Electrical Products

Analogue Dimming Microwave Presence/Absence Detector

The Power To Supply... All Your Electrical Products

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

PIR movement and presence detectors 10 A

IN2 Lighting Control Devices

Tri-level Control HF Sensor

EBDSPIR-PRM-LV Product Guide

MWS3A-PRM Product Guide

An-10 Wireless lighting control technology

An-10 Wireless lighting control technology

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Canolux LED. Petrol Station Forecourt Luminaires

Lighting Control Strategies. to meet code requirements save energy and improve building performance

CHALLENGER 66 INDUSTRIAL

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

Schneider Electric occupancy sensor range. Lighting the way to simple energy saving solutions

HIGH BAY APPLICATIONS

Save energy. ARGUS presence detectors

SWITCHLITE MRE SLDM ADJ

LightSpot. Stand-alone lighting control

Movement-based energy control

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

PRODUCT CATALOGUE LIGHT CONTROL Grässlin products for the intelligent control of light

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

µdim Microwave Sensors User Manual

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Built-in HF Sensor for High Bay

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

Daylight harvest function to regulate light output for maintaining required lux level

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Masterseal Plus. IP66 Ingress Protected. Thrives in the Toughest Conditions.

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

Dimming - Wired. What do I need? 1-10V Dimmer 4 wires to dimmer. 0/1-10V interface for dimming DimLine Key. Key

11,1 30. Ordering data

VERSION 2 VISION LIGHTING CONTROLS

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Ceiling Microwave presence/absence detector 12-24V AC/DC

Tri-level Control HF Sensor

MANUFACTURED IN THE UK

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Illuminating. Solutions. for Energy Saving. Featuring the latest PIR Lighting solutions from Timeguard.

SECTION LIGHTING CONTROLS

North America Version / Dimming Function. Introduction

SWITCHLITE MRE DDM ADJ

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Movement Detector GJD 300

MWS3 Ceiling Mount Microwave Occupancy Detector

Instructions PRODUCT RANGE NEWLEC DALI OCCUPANCY DETECTOR PART NUMBER NL5701DALI

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

ARGUS presence detectors. Move towards energy efficiency

Standalone Presence Detectors

Transcription:

P ro d u c t C ata l o g u e J a n ua ry 2 0 1 2 Energy Saving Security Convenience

Welcome Welcome Welcome to the DAERS catalogue. We hope you find it clear and informative. Feel free to call us if you require any further information. We will be pleased to help you. Queen s Award for Enterprise: Innovation Since the release of the last product catalogue DAERS imited have been awarded the prestigious Queen s Award for Enterprise: Innovation by the Queen s representative John Bush, OBE, H.M. ord-ieutenant of Wiltshire, who also officially opened the newly acquired DAERS Business Centre. This acquisition has enabled DAERS to expand their production and office facilities to cope with current and future growth. Flying the flag for UK manufacturing DAERS have recently been recognised for their contribution to UK manufacturing through the nomination by their local MP, Duncan Hames, to represent the Chippenham constituency in the government s Made by Britain initiative. Further details can be found on the government website www.policyconnect.org.uk/apmg/made-by-britain.org Additions to the DAERS range The 2012 catalogue sees a number of new products added to the DAERS range including the following: DAERS have launched a cost effective Batten Mount PIR occupancy with an IP65 rated enclosure making it ideal for indoor or outdoor use (see page 25). DAERS have also increased their range of grid modules for Time lag es, Trailing and eading edge dimmers and High frequency dimmers with the release of modules suitable for the popular DETA and GET Grid formats. With a number of further product developments planned for release early in 2012, please visit our website www.danlers.co.uk for the latest information. Tony Kay Executive Chairman 2

Introduction Electronic controls DAERS imited design and manufacture a range of high quality electronic es for the control of lighting, heating, ventilation and air conditioning. Energy saving, security and convenience are among the many benefits offered by DAERS controls. The products are straightforward to install and generally use the existing wiring, making them suitable for retrofitting or new installations. The energy saving products include relays with special high surge contact material. These products are designed to up to 6 amps (1500W at 230VAC) of resistive, transformer or fluorescent lighting s, or up to 1amp (250W) of fans. Bespoke and O.E.M products and services Special versions of our products can be made to suit customers needs. DAERS also design and manufacture bespoke versions for Original Equipment Manufacturers. DAERS also offer manufacturing services, including surface mount and through hole electronic assembly. Please enquire for further details or visit www.danlerscem.co.uk Customer service We pride ourselves on giving personal service and prompt response to customers needs. Please call us if you require further catalogues in this A4 format or in a smaller D (1/3 A4) format. Display boards for trade counters or show rooms are also available on request and free of charge in 3 sizes (500 x 575mm wall mounted, A3-420 x 297mm wall mounted, Counter top dispenser). Each has a D (1/3 A4) catalogue dispenser. Quality Assurance DAERS imited is an ISO9001 and ISO14001 accredited company. Every product is tested after manufacture as standard. All relevant DAERS products carry the CE mark. All DAERS electronic es comply with Directive 93/68/EEC (Electrical Equipment Safety Regulations 1994) and with Standard E 60669-2-1 (Electronic Switches). DAERS dimmer es also meet Standard BS E 55015: 1993. DAERS products enable compliance with the requirements of the Building Regulations Approved Documents 2A and 2B for the Conservation of Fuel and Power and with the recommendations of the 2nd tier document:- BRE Digest 498 - Selecting ighting Controls. Many of DAERS energy saving products qualify for the Enhanced Capital Allowance Scheme run by the Carbon Trust. All products are manufactured by DAERS in the U.K. except for the radio remote controls which are manufactured in Austria and the U.K. Our warranty extends to five years from the date of manufacture. ISO 9001: 2008 Registration o. 879 When installing any DAERS products, please ensure that the most recent edition of the appropriate local wiring regulations has been observed and that appropriate protective measures have been applied. DAERS imited has a policy of continuous development. The right is reserved to change specifications without prior notification or public announcement. ISO 14001: 2004 Registration o. 879 DAERS imited, DAERS Business Centre, Vincients Road, CHIPPEHAM, Wiltshire, S14 6Q United Kingdom. Tel:+44 (0)1249 443377. Fax:+44 (0)1249 443388. E-mail: sales@danlers.co.uk www.danlers.co.uk 3

COTETS 6-25 PIR occupancy es Ideal for energy saving. For automatic control of lighting (or other s). Comprising passive infra-red quad person detector, adjustable photocell override, adjustable time lag. Ceiling flush-mounted PIR occupancy es. Ceiling flush-mounted splashproof PIR occupancy. Ceiling surface-mounted PIR occupancy es. 12 and 24 volt low voltage PIR occupancy es. Ceiling plug-in PIR occupancy. Wall mounted PIR occupancy es (including a no neutral version). Directional plug-in PIR occupancy. Directional long range plug-in PIR occupancy. Batten mounted PIR occupancy. PIR occupancy modules suitable for Eurodata plates. Ceiling mounted, long range PIR occupancy. 17 Ancillary products Ceiling sockets for plug-in ceiling controls. Ceiling sockets with slave relays for controlling optional extra circuits. 26-27 PIR occupancy es with daylight linked dimming PIR occupancy es with automatic dimming to compensate for changes in ambient light level. For fluorescent s with dimmable high frequency ballasts. Version suitable for dimmable ballasts with 1-10VDC input. Version suitable for DSI dimmable ballasts. 28-29 Daylight linked dimmers For automatic dimming to compensate for changes in ambient light level. For fluorescent s with dimmable high frequency ballasts. Version suitable for dimmable ballasts with 1-10VDC input. Version suitable for DSI dimmable ballasts. 30-31 Ceiling photocell es Adjustable photocells for ing indoor lighting. Ideal for energy saving. oading up to 6 amps (1500W at 230VAC) of resistive, fluorescent or transformer lighting s. 32-41 Time lag es Ideal for energy saving. Adjustable time lags. Exterior time lag es: IP66 rated. Available as either 6 amp (1500W) or 16 amp (4000W) versions. Plated time lag es: oading up to 6 amps (1500W at 230VAC) of resistive, fluorescent or transformer lighting s, or up to 1 amp (250W) of fans. Grid time lag modules: oading up to 6 amps (1500W at 230VAC) of resistive, fluorescent or transformer lighting s, or up to 1 amp (250W) of fans. Multi-selectable time lag. 42-43 Outdoor security es Outdoor PIR with adjustable photocell override. Adjustable outdoor photocell es. 4

COTETS 44-45 Quiet dimmers (trailing edge) Push button action in grid versions. Suitable for dimming: Incandescent lamps, mains halogen lamps (must include integral safety fuse), most directly dimmable ED lamps, dimmable electronic transformers. Multi-way ing AD dimming using matching slaves. 46-47 Soft start dimmers (leading edge) Push button action in high quality plates or grid versions. Soft start dimming for tungsten, mains halogen and dimmable transformer s. Multi-way ing AD dimming using matching slaves. Versions up to 630W. 48-49 Push and rotary dimmers (leading edge) Versions for tungsten, mains halogen and dimmable transformer s. Versions up to 1000W. 1, 2, 3 and 4 gang plates. 1-way and 2-way ing. 50-51 Manual high frequency dimmers Manual push dimmers for fluorescent s with dimmable high frequency ballasts. Plated versions and Grid module versions. Versions suitable for dimmable ballasts with 1-10VDC input. Version suitable for DSI dimmable ballasts. 52-53 HVAC controls For Heating, Ventilation and Air Conditioning. PIR thermostat controls which combine PIR person detector with room thermostat. Versions for heating and cooling s. Heater boost with selectable time lag. Fan speed control. 54-64 Radio remote and Active infra-red controls Remote control ing and dimming. Hand held or wire-free wall mounted senders. Receiver es and dimmers for indoor or outdoor mounting. Active infra-red remote control ing and dimming for shorter range "line of sight" applications. 65 Additional products Pattress box for surface-mounted ceiling products. Ceiling box for ceiling socket. Test plug for ceiling socket or slave relays. oad resistor to augment small s. 66-71 Bespoke / O.E.M. products, manufacturing services and relay options Products for Original Equipment Manufacturers including PIR occupancy es, Time lag es, Controls with low voltage inputs and with low voltage, volt-free outputs. Dimmer modules and Time lag modules for O.E.M s. to assemble onto their own plates. Manufacturing services, including surface mount and through hole electronic assembly. 5

PIR OCCUPACY SWITCHES PIR occupancy es The DAERS range of passive infra-red occupancy es is designed for the automatic control of lighting, heating, ventilation or air conditioning s. The PIR will on the connected automatically when an area is occupied, and then it off automatically when the area has been vacant for a chosen duration. This has the benefits of reduced energy bills and automatic control. When being used to control lighting, the built-in photocell can be used to keep the lights off on bright days. PIR occupancy es are ideal for: Offices Factories Warehouses Schools eisure centres Hospitals Canteens Staff rooms Corridors and stairwells Rential homes Military accommodation Student accommodation Toilet blocks Changing rooms Plus many other uses PIR occupancy variants Special variants of products are available on request such as 24V (a.c. or d.c.) versions of our PIR occupancy es and photocell es, ideal for low voltage control systems. 12V variants can also be supplied. Some variants are available from stock for next day delivery. To special order we can also supply volt free outputs for mains, 24V or 12V supplies (including versions with gold relays). 6

PIR OCCUPACY SWITCHES PIR occupancy functions Each PIR occupancy in the DAERS range has a passive infra-red quad person detector (except COPD and BMPIR which have a passive infra-red dual person detector). This detects the movement of a warm body moving within its detection zone. When such a movement is detected the is ed on. There is a time lag function which is adjusted using a spindle on the of the product. The time lag is the time that must elapse with no movement detected before the PIR occupancy will off. Simple adjustment spindles There is a built-in, adjustable, photocell override which can be used to keep lights off when there is sufficient daylight available. The photocell can only be used in this way if the amount of natural daylight exceeds the level of the artificial lights. The photocell can be set to inactive when controlling heating, ventilation or air conditioning. The photocell is also adjusted by a spindle on the of the product. Each PIR occupancy contains a relay suitable for ing any type of, including fluorescent lights and fans. A few PIR occupancy es may be wired in parallel to control the same. However, there are minimum restrictions with the WAPIR model only (see page 21). The PIR occupancy es require a mains supply. Function demonstrated with the lighting in an office PIR occupancy brings lights on only when needed Enough daylight, Occupied ighting OFF Enough daylight, Unoccupied ighting OFF ight, Occupied ighting O ight, Unoccupied ighting OFF 7

PIR OCCUPACY SWITCHES PIR occupancy specifications PIR detector Passive infra-red quad person detector. Adjustable time lag Time lag adjustable in 9 steps (approximate values): 10 seconds 20 seconds 40 seconds 1.25 minutes 2.5 minutes 5 minutes 10 minutes 20 minutes 40 minutes Adjustable photocell "Inhibit on" photocell. The photocell will inhibit the lights from ing on when somebody enters an area with plenty of ambient light. However, if somebody is already occupying an area with the lights ed on, the lights will remain on while the area is occupied, regardless of any increase in the ambient light level. This is to avoid any nuisance ing off when somebody is in the middle of a task or meeting. Range 100-1000 lux (and photocell inactive), falling on the working plane. oading All models can up to 6 amps (1500W at 230VAC) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps. For the WAPIR model there are some minimum requirements (details on page 21). Wiring in parallel A few PIR es can be wired in parallel to control the same. Start-up Mode When the mains supply is initially connected to the PIR occupancy it goes through its Start-up Mode. This means it es on for about 1 minute, then es off and enters its Operating Mode. If a manual wall is feeding the PIR occupancy (see wiring diagrams on appropriate product pages) then it will go through the Start-up Mode each time the wall is ed on (not applicable to WAPIR, see page 21). By wiring the manual wall in the alternative position, the supply to the PIR occupancy is uninterrupted and it remains in Operating Mode. It does not go through its Start-up Mode each time the wall is ed on. 8

PIR OCCUPACY SWITCHES Selecting the appropriate PIR occupancy CEIIG MOUTED WA MOUTED 360 detection zone 120 directional detection angle ong range directional narrow beam 120 detection angle Flush-mounted (false or plasterboard ceilings) Surface mounted Surface mounted Surface mounted Plaster depth (16mm) wall box Hard wired Hard wired Hard wired Plug and socket Hard wired Plug and socket Plug and socket Plug and socket eeds neutral wire o neutral wire needed CEF PIR CEF PIR SEAED CEF PIR 10A CEFP PIR + CESO CESF PIR CEO + CESO SQ CEDR 6P + CESO CEDR 6PR + CESO WACE PIR WAPIR Page 12 Page 13 Page 13 Page 12 Page 15 Page 16 Page 18 Page 19 Page 20 Page 21 9

PIR OCCUPACY SWITCHES Two ceiling flushmounted CEF PIR controlling the lights in a meeting room. In this, and other offices, a manual wall is retained to override the lights to off, e.g. for a video presentation. Small offices are covered by a single ceiling flush-mounted CEF PIR. The wall has been replaced by a wall mounted WAPIR. MEETIG ROOM OFFICE OFFICE OFFICE CORRIDOR ong range directional CEDR 6PR to detect people in the 25 metre corridor. OPE PA OFFICES Scale 0 5m 10m Application diagram The diagram illustrates PIR occupancy siting within a typical office/ factory facility. The coloured zones emanating from the controls show strong detection zones (darker tints with solid coloured line) and secondary detection zones (lighter tint with broken coloured line). Ceiling flush-mounted CEF PIR spaced every 5 metres to cover the open plan office and control the lights. The CEF PIR can be wired in groups in parallel, to control the lighting in zones. 10

Two ceiling surfacemounted CESF PIR (one on each landing) wired in parallel to control the lighting in the stairwell. In the toilets a ceiling flushmounted CEF PIR has been wired in parallel with a wall mounted WACE PIR in the lobby, to control the lighting in both rooms together. In the shower room a CEF PIR SEAED is used, as it has protection against light splashes and condensation. Ceiling directional CEDR 6P covers the open staircase. TOIETS TOIET OBBY SHOWER ROOM OPE STAIRCASE STAIRWE FACTORY AREA RESTROOM HIGH BAY RACKIG HIGH BAY RACKIG ong range directional CEDR 6PR detects people in a racking storage aisle. RECEPTIO Ceiling flushmounted CEF PIR spaced every 5 metres to cover the open plan reception area and control the lights. Ceiling plug-in CEO mounted on BESA box on ceiling conduit. Spaced at 5 metre intervals to control the lights in the restroom. Ceiling surfacemounted CESF PIR spaced every 5 metres to give total coverage of the open plan factory area. 11

PIR OCCUPACY SWITCHES These neat and unobtrusive models are ideal for flush mounting through suspended or plasterboard ceilings. They have a 2m cable, for quick and easy installation. Ceiling flush-mounted PIR occupancy CEF PIR Detection zone: 360 Time lag range: Photocell range: oading: 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 12a and 12b below 72mm diameter x 68mm Ideal for false or plasterboard ceilings CEFP PIR Special versions Plug and socket version: CEFP PIR Model CEFP PIR is provided with a plug suitable for the CESO Ceiling socket shown on page 17. oading: Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps Control plugged into a CESO on a BESA box PIR occupancy variants Variants are available on request such as 24V or 12V (a.c. or d.c.), ideal for low voltage control systems. To special order we can also supply volt free outputs for mains, 24V or 12V supplies (including versions with gold contact relays). Detection diagrams Plan view of detection zone Fig. 201 Ceiling mounted PIR occupancy Perspective view of detection zone Several PIR occupancy es Up to 5m Up to 7m Strong detection zone i.e. person moving arm Secondary detection zone i.e. person walking (less sensitive when walking straight towards PIR ) For optimum coverage recommended mounting height between 2.4 and 5m. PIR Quad detector gives 124 detection areas within the zone. CEF PIR Up to 5m Up to 7m Strong detection zone Secondary detection zone In open plan areas For best coverage the CEF PIR should be spaced every 5m in either direction Up to 5m Up to 5m Wiring diagrams 66 2m cable 60 72 55 3 plan 38 72 Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling 12a. Single CEF PIR 12b. A few CEF PIR wired in parallel optional manual wall for overriding off CEF PIR S alternative position for optional wall (see p.8 Start-up Mode ) optional manual wall for overriding off S S S A few CEF PIR alternative position for optional wall (see p.8 Start-up Mode ) 12

PIR OCCUPACY SWITCHES These neat and unobtrusive models are ideal for flush mounting through suspended or plasterboard ceilings. They have a 2m cable, for quick and easy installation. Splashproof ceiling flush-mounted PIR occupancy CEF PIR SEAED Model CEF PIR SEAED is protected against light splashes and condensation when installed in the ceiling. Ideal for bathrooms, shower rooms, etc. Detection zone: 360 Time lag range: Photocell range: oading: 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 13a and 13b below 72mm diameter x 68mm An extra sealed version is also available on request (order code: CEF PIR SEAED XS). 10 amp rated ceiling flush-mounted PIR occupancy CEF PIR 10A Detection zone: 360 Time lag range: Photocell range: oading: 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive Up to 10 amps (2500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 13a and 13b below 72mm diameter x 68mm Detection diagrams Plan view of detection zone Fig. 201 Ceiling mounted PIR occupancy Perspective view of detection zone Several PIR occupancy es Up to 5m Up to 7m Strong detection zone i.e. person moving arm Secondary detection zone i.e. person walking (less sensitive when walking straight towards PIR ) For optimum coverage recommended mounting height between 2.4 and 5m. PIR Quad detector gives 124 detection areas within the zone. CEF PIR Up to 5m Up to 7m Strong detection zone Secondary detection zone In open plan areas For best coverage the CEF PIR should be spaced every 5m in either direction Up to 5m Up to 5m Wiring diagrams 66 2m cable 60 72 55 3 plan 38 72 Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling 13a. Single PIR occupancy 13b. A few PIR occupancy es wired in parallel PIR alternative position occupancy for optional wall optional manual wall (see p.8 for overriding off S Start-up Mode ) optional manual wall for overriding off S S S A few PIR occupancy es alternative position for optional wall (see p.8 Start-up Mode ) 13

PIR OCCUPACY SWITCHES DAERS manufacture a range of variants of the Ceiling flush-mounted PIR for integrating into building management systems, low voltage applications etc. Ceiling flush-mounted PIR occupancy variants 12 volt version: CEF PIR 12V Operating voltage of the is 12 volt a.c. or d.c. 12 volt version with volt free contacts: CEF PIR 12VVF Operating voltage of the is 12 volt a.c. or d.c. Comes with 4-core flex. 24 volt version: CEF PIR 24V Operating voltage of the is 24 volt a.c. or d.c. CEF PIR 12V CEF PIR 12VVF CEF PIR 24V CEF PIR 24VVF 24 volt version with volt free contacts: CEF PIR 24VVF Operating voltage of the is 24 volt a.c. or d.c. Comes with 4-core flex. Detection zone: 360 Time lag range: Photocell range: oading: 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive 12V to 240V: 10mA to 6 amps of resistive, transformer or fluorescent lighting s, 2 amps of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp of fans or most metal halide lamps See diagrams 14a and 14b below 72mm diameter x 68mm Other PIR occupancy variants DAERS also manufacture many other variants of their PIR occupancy es including the following variants: ormally closed contacts Gold contacts Double detection to reduce false triggering Reduced sensitivity to reduce false triggering Extra sealed for draughty environments Detection diagrams Plan view of detection zone Fig. 201 Ceiling mounted PIR occupancy Perspective view of detection zone Several PIR occupancy es Up to 5m Up to 7m Strong detection zone i.e. person moving arm Secondary detection zone i.e. person walking (less sensitive when walking straight towards PIR ) For optimum coverage recommended mounting height between 2.4 and 5m. PIR Quad detector gives 124 detection areas within the zone. CEF PIR Up to 5m Up to 7m Strong detection zone Secondary detection zone In open plan areas For best coverage the CEF PIR should be spaced every 5m in either direction Up to 5m Up to 5m Wiring diagrams plan 14a. Volt free, normally open 14b. Volt free, normally closed 2m cable 38 66 55 Supply Voltage O Supply Voltage C 3 60 72 72 Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling eutral or 0V oad eutral or 0V oad 14

PIR OCCUPACY SWITCHES These surface-mounted models are ideal for solid ceilings. Ceiling surface-mounted PIR occupancy The CESF PIR is a hard wired version and can be mounted on a square pattress box. CESF PIR Detection zone: 360 Time lag range: Photocell range: oading: 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 15a and 15b below 86 x 86 x 22mm. Requires back box depth 16mm Can be mounted on a square pattress box, order code: PABO. Ceiling surface-mounted PIR occupancy variants Variants are available on request such as 24V or 12V (a.c. or d.c.), ideal for low voltage control systems. To special order we can also supply volt free outputs for mains, 24V or 12V supplies (including versions with gold contact relays). Detection diagrams Plan view of detection zone Fig. 201 Ceiling mounted PIR occupancy Perspective view of detection zone Several PIR occupancy es Up to 5m Up to 7m Strong detection zone i.e. person moving arm Secondary detection zone i.e. person walking (less sensitive when walking straight towards PIR ) For optimum coverage recommended mounting height between 2.4 and 5m. PIR Quad detector gives 124 detection areas within the zone. CESF PIR Up to 5m Up to 7m Strong detection zone Secondary detection zone In open plan areas For best coverage the CESF PIR should be spaced every 5m in either direction Up to 5m Up to 5m Wiring diagrams Requires 16mm deep box 15a. Single CESF PIR 15b. A few CESF PIR wired in parallel plan 86 86 22 optional manual wall for overriding off CESF PIR S alternative position for optional wall (see p.8 Start-up Mode ) optional manual wall for overriding off S S S A few CESF PIR alternative position for optional wall (see p.8 Start-up Mode ) 15

PIR OCCUPACY SWITCHES These surface-mounted models are ideal for solid ceilings. Ceiling surface-mounted plug-in PIR occupancy CEO Requires socket, order code: CESO SQ or CESO (see page 17) The CEO has a built-in plug suitable for the CESO SQ Ceiling socket (or CESO Ceiling socket). CESO SQ can be mounted on a square pattress box (the CESO can be mounted on a BESA box). Detection zone: 360 Time lag range: 10 seconds to 40 minutes in 9 steps Photocell range: 100 to 1000 lux, and inactive oading: (Each circuit) up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps. See diagrams 16a, 16b, 16c below 88 x 88 x 47mm Detection diagrams Plan view of detection zone Perspective view of detection zone Several PIR occupancy es Up to 5m Up to 7m Strong detection zone i.e. person moving arm Secondary detection zone i.e. person walking (less sensitive when walking straight towards PIR ) For optimum coverage recommended mounting height between 2.4 and 5m. PIR Quad detector gives 124 detection areas within the zone. CEO Up to 5m Up to 7m Strong detection zone Secondary detection zone In open plan areas For best coverage the CEO should be spaced every 5m in either direction Up to 5m Up to 5m plan 88 (CESO SQ) 88 47 Wiring diagrams 16a. Single CEO 16b. A few CEO wired in parallel optional manual wall for overriding off CEO S alternative position for optional wall (see p.8 Start-up Mode ) optional manual wall for overriding off CEO CEO CEO S S S alternative position for optional wall (see p.8 Start-up Mode ) 16c. Ceiling mounted socket (CESO SQ or CESO) Pattress box or BESA box A CESO SQ or CESO luminaire S S CEO ot to scale 16

ACIARY PRODUCTS Sockets for plug-in ceiling controls Ceiling socket: CESO For use with DAERS plug-in ceiling controls. Can be mounted on a BESA box. See diagram 17a below 74mm diameter x 13mm Also available as a square socket. CESO Ceiling socket: CESO SQ Can be mounted on a square pattress box. See diagram 17a below 87 x 87 x 13mm Slave relays for plug-in ceiling controls CESO SQ CES or CE2S Ceiling socket with slave relay: CES Ceiling socket with slave relay with isolated changeover contacts. Enables the ing of an additional circuit with its own supply, e.g. the corridor lights out an office or a separate low voltage control circuit. A no socket version is available on request. oading: (Each circuit) up to 6 amps (1500W) incandescent or mains halogen lamps. Up to 4 amps (1000W) electronic or wire wound transformers, fluorescent lamps (high frequency or soft start). Up to 2 amps (500W) compact fluorescent or ED lamps. Up to 1 amp (250W) most fans and metal halide discharge lamps. See diagram 17b below 87 x 87 x 41mm Ceiling socket with double slave relay: CE2S Ceiling socket with a double slave relay with isolated changeover contacts. Enables the ing of two additional circuits, each with its own supply, e.g. the corridor lights out an office, plus the extractor fans in the office. Also ideal for controlling two separate low voltage control circuits. A no socket version is available on request. oading: As CES above See diagram 17c below 87 x 87 x 41mm Ceiling socket (CESO) Ceiling socket (CESO SQ) Ceiling slave relays (CES / CE2S) 13 plan plan 74 87 87 87 87 plan 87 13 87 41 Wiring diagrams 17a. Ceiling mounted socket (CESO or CESO SQ) for plug-in ceiling controls BESA box or pattress box A S CESO or CESO SQ plug-in ceiling control luminaire S ot to scale 17b. Plug-in control plus slave relay with volt free changeover contacts (CES) controlling one extra circuit 1 S2 /O separate circuit C2 S2 /C 1 optional manual CES S1 wall for plus overriding off plug-in 17c. Plug-in control plus double slave relay with volt free changeover contacts (CE2S) controlling two extra circuits 1 1 S2 /O separate circuit C2 optional manual wall for overriding off S2 /C S3 /O separate circuit CE2S plus plug-in C3 S1 S3 /C 17

PIR OCCUPACY SWITCHES These directional PIR es plug into a ceiling mounted socket. The socket can be mounted on a BESA box. Ceiling directional PIR occupancy Standard range CEDR 6P Requires socket, order code: CESO (see page 17) Standard range version Designed to give a directional view of the activity to be monitored. Detection angle 120. Time lag range: Photocell range: oading: 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 18a, 18b, 18c below See below CEDR 6P can be rotated and lowered to a 45º angle Detection diagrams Perspective view Plan view Side elevation CEDR 6P 60 120 CEDR 6P 60 120 Strong Detection Zone Secondary Detection Zone Strong Detection Zone Secondary Detection Zone CEDR 6P Up to 5m Up to 10m Up to 5m Up to 10m (CESO) 74 64 60 102 Wiring diagrams 18a. Single CEDR 6P 18b. A few CEDR 6P wired in parallel 18c. Ceiling mounted socket (CESO) optional manual wall for overriding off CEDR 6P S alternative position for optional wall (see p.8 Start-up Mode ) optional manual wall for overriding off S S S A few CEDR 6P alternative position for optional wall (see p.8 Start-up Mode ) BESA box A CESO luminaire S S CEDR 6P ot to scale 18

PIR OCCUPACY SWITCHES These directional PIR es plug into a ceiling mounted socket. The socket can be mounted on a BESA box. Ceiling directional PIR occupancy ong range CEDR 6PR Requires socket, order code: CESO (see page 17) ong range version With a long range, narrow detection beam. Designed for corridors and storage aisles. Time lag range: Photocell range: oading: 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 19a, 19b, 19c below See below DAERS also manufacture a ong range ceiling flush mounted PIR occupancy, order code CEF PIR R see page 24 for details. CEDR 6PR can be rotated and lowered to a 45º angle Detection diagrams Perspective view Plan view CEDR 6PR 6 Up to 10m Strong Detection Zone i.e. person walking towards PIR 15m Up to 25m Secondary Detection Zone i.e. person walking across the zone Side elevation CEDR 6PR CEDR 6PR Ideal mounting height between 2.2 and 3m Up to 10m 15m Up to 25m (CESO) 74 64 60 115 Wiring diagrams 19a. Single CEDR 6PR 19b. A few CEDR 6PR wired in parallel 19c. Ceiling mounted socket (CESO) optional manual wall for overriding off CEDR 6PR S alternative position for optional wall (see p.8 Start-up Mode ) optional manual wall for overriding off S S S A few CEDR 6PR alternative position for optional wall (see p.8 Start-up Mode ) BESA box A CESO luminaire S S CEDR 6PR ot to scale 19

PIR OCCUPACY SWITCHES The WACE PIR is suitable for either wall or ceiling mounting. It fits either into a plaster depth (16mm) wall box or onto a ceiling mounted square pattress box. It requires a neutral wire. Wall or ceiling mounted PIR occupancy Applications Suitable for stairwells, corridors, toilet lobbies, etc. Version incorporating override off button, enabling lights to be held off during video presentations etc, available by request. WACE PIR Detection angle: 120 Time lag range: Photocell range: oading: 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 20a and 20b below 86 x 86 x 22mm. Wall box depth 16mm Detection diagrams Perspective view Plan view Side elevation WACE PIR 120 60 Strong Detection Zone Secondary Detection Zone WACE PIR 45 90 Strong Detection Zone Secondary Detection Zone Wall mounted PIR occupancy Up to 5m Up to 10m Ideal mounting height between 1 and 1.8m Up to 5m Up to 10m Wiring diagrams Requires 16mm deep box 20a. Single WACE PIR 20b. A few WACE PIR wired in parallel, eg. in a stairwell plan 86 22 WACE PIR S A few WACE PIR 86 S S S 20

PIR OCCUPACY SWITCHES The WAPIR model replaces an existing wall no neutral wire is needed. It fits into a plaster depth (16mm) wall box. The WAPIR model also has a manual override off on the of the plate. Wall mounted PIR occupancy WAPIR Applications The WAPIR requires a permanent live supply and should only be used in applications where the lights would not be on for more than 12 hours per day. This is to allow its rechargeable battery enough time to recharge itself from the mains supply. The WAPIR is supplied with a capacitor to augment small s. The WAPIR is suitable for small offices, meeting rooms, tutoring rooms, etc. The override off button (out position) enables the lights to be held off during video presentations, etc. A version without the manual override button is also available on request (order code WAPIRX). For wall mounting only. Detection angle: 120 Time lag range: Photocell range: Maximum : Minimum : 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps 40W resistive or approximately 100W inductive per WAPIR in the circuit. A capacitor (CAPOAD) is supplied to augment small s. See diagram 21a and 21b below 86 x 86 x 22mm. Wall box depth 16mm Detection diagrams Perspective view Plan view Side elevation WAPIR 120 60 Strong Detection Zone Secondary Detection Zone WAPIR 45 90 Strong Detection Zone Secondary Detection Zone Wall mounted PIR occupancy Up to 5m Up to 10m Ideal mounting height between 1 and 1.8m Up to 5m Up to 10m Wiring diagrams Requires 16mm deep wall box 21a. Single WAPIR 21b. A few WAPIR wired in parallel plan 86 22 WAPIR S WAPIR WAPIR WAPIR 86 S S S 21

PIR OCCUPACY SWITCH MODUES These modules are suitable for mounting onto Eurodata plates and fit into a 35mm deep wall box. They are also suitable for building into luminaires (see page 68 for fixing bezel). They require a neutral wire. 5m detection - concealed adjustment spindles GREUW PIR5X Adjustment spindles hidden behind surface lid for a neat finish (module must be removed from wall plate or luminaire to adjust). Can be suited in with other Eurodata modules. Detection zone: 360 Detection angle: 100 Time lag range: 10 seconds to 40 minutes in 9 steps Photocell range: 15 to 1000 lux, and inactive oading: Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 22a and 22b below 50 x 25 x 38mm, minimum wall box depth of 35mm 5m detection - visible adjustment spindles GREUW PIR5E Adjustment spindles visible on surface for quick and convenient adjustment. Can be suited in with other Eurodata modules. Detection zone: 360 Detection angle: 100 Time lag range: 10 seconds to 40 minutes in 9 steps Photocell range: 15 to 1000 lux, and inactive oading: Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 22a and 22b below 50 x 25 x 38mm, minimum wall box depth of 35mm Detection diagrams Perspective view (ceiling mounted) Plan view (wall mounted) Side elevation (wall mounted) For optimum coverage recommended mounting height between 2.4 and 5m GREUW PIR5X or GREUW PIR5E Detection zone GREUW PIR5X or GREUW PIR5E 50 100 Detection Zone GREUW PIR5X or GREUW PIR5E 40 80 Detection Zone Up to 7m Up to 5m Up to 5m Up to 5m GREUW PIR5X, GREUW PIR5E. Requires wall box depth of 35mm 25 50 38 Wiring diagrams 22a. Single PIR occupancy module 22b. A few PIR occupancy modules wired in parallel, eg. in a stairwell PIR occupancy module S S S S A few PIR occupancy modules 22

PIR OCCUPACY SWITCH MODUES These modules are suitable for mounting onto Eurodata plates. They are also suitable for building into luminaires (see page 68 for fixing bezel). They require a neutral wire. These versions are best suited for use in areas such as warehouses, sports halls and circulation areas, where there is likely to be a significant level of movement. 10m detection - concealed adjustment spindles GREUW PIR10X Adjustment spindles hidden behind surface lid for a neat finish (module must be removed from plate or luminaire to adjust). Can be suited in with other Eurodata modules. Detection zone: 360 Time lag range: 10 seconds to 40 minutes in 9 steps Photocell range: 15 to 1000 lux, and inactive oading: Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 23a and 23b below 50 x 25 x 38mm, minimum back box depth of 35mm A photocell override version is available on request. 10m detection - visible adjustment spindles GREUW PIR10E Adjustment spindles visible on surface for quick and convenient adjustment. Suitable for mounting onto a Eurodata plate. Can be suited in with other Eurodata modules. Detection zone: 360 Time lag range: 10 seconds to 40 minutes in 9 steps Photocell range: 15 to 1000 lux, and inactive oading: Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 23a and 23b below 50 x 25 x 38mm, minimum back box depth of 35mm A photocell override version is available on request. Detection diagrams Perspective view (ceiling mounted) For optimum coverage recommended mounting height between 5 and 10m GREUW PIR10X or GREUW PIR10E Detection zone Up to 15m Up to 12m GREUW PIR10X, GREUW PIR10E. Requires back box depth of 35mm 25 50 38 Wiring diagrams 23a. Single PIR occupancy module 23b. A few PIR occupancy modules wired in parallel, eg. in a stairwell optional manual wall for overriding off PIR occupancy module S S S S A few PIR occupancy modules 23

PIR OCCUPACY SWITCHES This long range PIR occupancy is ideal for storage aisles and high bay applications where a height of up to 20m is required. Ceiling mounted long range PIR occupancy With a long range, narrow detection beam. Designed for warehouses and storage aisles with a narrow point of access. CEF PIR R is also suitable for building into luminaires. CEF PIR R Time lag range: Photocell range: oading: 10 seconds to 40 minutes in 9 steps 100 to 1000 lux, and inactive Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps See diagrams 24a and 24b below See below A photocell override version of the above is available on request. DAERS also manufacture a PIR occupancy module suitable for mounting onto Eurodata plates with a 12 metre range for storage aisles and warehouses (order code GREUW PIR12E). Please call for further details. Detection diagram CEF PIR R Strong Detection Zone i.e. person moving arm Up to 10m 15m Up to 20m 6 Secondary Detection Zone i.e. person walking across the zone Wiring diagrams 66 17 2m cable 60 72 55 3 plan 38 72 Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling 24a. Single CEF PIR R 24b. A few CEF PIR R wired in parallel optional manual wall for overriding off CEF PIR R S alternative position for optional wall (see p.8 Start-up Mode ) optional manual wall for overriding off S S S A few CEF PIR R alternative position for optional wall (see p.8 Start-up Mode ) 24

PIR OCCUPACY SWITCHES Cost effective, quick and easy to fit PIR occupancy designed to fit onto the end of lighting battens. Batten mounted PIR occupancy DAERS Batten mount PIR occupancy can be mounted onto the end of lighting battens via the 20mm knock out. The includes the connection 20mm thread and 1 metre of wire tails to connect to the lighting ballast. BMPIR BMPIR fitted on the end of a lighting batten. Ideal for use in factories, warehouses, offices, schools etc but also wetrooms, damp areas and outdoor environments such as car parks due to its tough IP66 rated enclosure. Switches lights on when somebody is detected. Switches lights off when nobody has been detected for a chosen period. The photocell can be set so that lights do not on during the day. Tough, compact IP66 rated polycarbonate moulding. Weatherproof: Detection range: Detection angle: 120 Time lag: Photocell range: oading: IP66 rating Up to 10m 2 to 20 minutes (adjustable) 10 lux to infinite lux (adjustable) Up to 6 amps (1500W) incandescent or mains halogen lamps. Up to 4 amps (1000W) electronic or wire wound transformers, fluorescent lamps (high frequency or soft start). Up to 2 amps (500W) compact fluorescent or ED lamps. Up to 1 amp (250W) most fans and metal halide discharge lamps. See diagram 25 below 75 x 60 x 37mm plus 1 metre wire tails Detection diagram Side elevation Plan view BMPIR BMPIR 45 90 60 120 Up to 5m Strong Detection Zone Secondary Detection Zone Strong Detection Zone Secondary Detection Zone Up to 10m Wiring diagram 60 37 25. Single PIR occupancy 65 optional manual for overriding off BMPIR S 20mm threaded entry spout 10 24 24 25

PIR OCCUPACY SWITCHES WITH DIMMIG Brings lights on only when area is occupied. Automatically dims lights according to ambient light level to maintain constant brightness of between 100 and 1000 lux (adjustable). Adjustable time lag before ing off. For suspended or plasterboard ceilings. Complete with 2m cables for quick and easy installation. PIR occupancy with daylight linked dimming CEF PIRDD 10VDC is suitable for dimmable ballasts with 1-10VDC input. CEF PIRDD 10VDC Detection zone: 360 Time lag range: 10 seconds to 40 minutes in 9 steps Photocell range: 100 to 1000 lux, falling on the working plane oading: Total of ballast, lamps plus other not more than 6 amps including fluorescent. Can control up to 20mA, eg. 20 ballasts at 1mA. (Varies according to make and model of ballasts) See diagram 26 below 72mm diameter x 68mm Enough daylight, Occupied ighting OFF Reduced daylight, Occupied ighting DIMMED ight, Occupied ighting O Enough daylight, Unoccupied ighting OFF Reduced daylight, Unoccupied ighting OFF ight, Unoccupied ighting OFF Detection diagrams Plan Plan view view of detection of detection zone zone Perspective view Perspective of detection viewzone of detection zone Covering large areas Strong detection zone i.e. person moving arm Secondary detection zone i.e. person walking (less sensitive when walking straight towards PIR ) For optimum coverage recommended mounting height between 2.4 and 5m. CEF PIRDD 10VDC Strong detection zone Secondary detection zone To cover large areas it is advisable to install one CEF PHDD 10VDC to dim and a few CEF PIR to. Up to 5m Up to 7m PIR Quad detector gives 124 detection areas within the zone. Up to 5m Up to 7m Wiring diagram plan 26. CEF PIRDD 10VDC controlling several 1-10VDC dimmable ballasts 66 2m cables 60 72 55 3 38 72 Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling optional manual wall for overriding off CEF PIRDD 10VDC S alternative position for optional wall (see p.8 Start-up Mode ) control lines optional other * 1 ballast 10 1 ballast 10 1 ballast 10 * Total of ballasts, lamps plus other not more than 6 amps 26

PIR OCCUPACY SWITCHES WITH DIMMIG Brings lights on only when area is occupied. Automatically dims lights according to ambient light level to maintain constant brightness of between 100 and 1000 lux (adjustable). Adjustable time lag before ing off. For suspended or plasterboard ceilings. Complete with 2m cables for quick and easy installation. PIR occupancy with daylight linked dimming CEF PIRDD DSI is suitable for DSI dimmable ballasts. CEF PIRDD DSI Detection zone: 360 Time lag range: 10 seconds to 40 minutes in 9 steps Photocell range: 100 to 1000 lux, falling on the working plane oading: Total of ballast, lamps plus other not more than 6 amps including fluorescent. Can control up to 20 DSI ballasts See diagram 27 below 72mm diameter x 68mm Enough daylight, Occupied ighting OFF Reduced daylight, Occupied ighting DIMMED ight, Occupied ighting O Enough daylight, Unoccupied ighting OFF Reduced daylight, Unoccupied ighting OFF ight, Unoccupied ighting OFF Detection diagrams Plan view of detection zone Fig. 201 Ceiling mounted PIR occupancy Perspective view of detection zone Covering large areas Strong detection zone i.e. person moving arm Secondary detection zone i.e. person walking (less sensitive when walking straight towards PIR ) For optimum coverage recommended mounting height between 2.4 and 5m. CEF PIRDD DSI Strong detection zone Secondary detection zone To cover large areas it is advisable to install one CEF PHDD DSI to dim and a few CEF PIR to. Up to 5m Up to 7m PIR Quad detector gives 124 detection areas within the zone. Up to 5m Up to 7m 2m cables plan 38 Wiring diagram 27. CEF PIRDD DSI controlling several DSI digital dimmable ballasts control lines 65 61 72 57 3 72 Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling CEF PIRDD DSI (50Hz) S optional manual wall for overriding off optional other * D1 ballast D2 D1 ballast D2 D1 ballast D2 * Total of ballasts, lamps plus other not more than 6 amps 27

DAYIGHT IKED DIMMERS These automatically dim lights according to ambient light level to maintain a constant brightness of between 100 and 1000 lux (adjustable). For suspended or plasterboard ceilings. Complete with 2m cables for quick and easy installation. Daylight linked dimmers Order codes: CEF PHDD 10VDC CEF DD 10VDC CEF PHDD 10VDC Has dimming and on/off ing and is suitable for dimmable ballasts with 1-10VDC input. Photocell range: 100 to 1000 lux, falling on the working plane oading: Total of ballast, lamps plus other not more than 6 amps including fluorescent. Can control up to 20mA, eg. 20 ballasts at 1mA. (Varies according to make and model of ballasts). See diagram 28a below 72mm diameter x 68mm CEF DD 10VDC Has dimming only and is suitable for dimmable ballasts with 1-10VDC input. Photocell range: 100 to 1000 lux falling on the working plane oading: Total of ballast, lamps plus other not more than 6 amps including fluorescent. Can control up to 20mA, eg. 20 ballasts at 1mA. (Varies according to make and model of ballasts). See diagram 28b below 72mm diameter x 68mm Ceiling surface mounted versions: CESF PHDD 10VDC and CESF DD 10VDC are also available on request. For Manual high frequency dimmers please see pages 50 and 51. Manual wall retained for overriding OFF Enough daylight ighting OFF Reduced daylight ighting DIMMED ight ighting O CEF PHDD 10VDC and CEF DD 10VDC 66 2m cables 60 72 55 3 plan 24 72 Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling Wiring diagrams 28a. CEF PHDD 10VDC controlling several 1-10VDC dimmable ballasts wall (optional) CEF PHDD 10VDC S optional other * control lines 1 ballast 10 1 ballast 10 1 ballast 10 * Total of ballasts, lamps plus other not more than 6 amps 28b. CEF DD 10VDC controlling several 1-10VDC dimmable ballasts wall (compulsary) CEF DD 10VDC control lines S 1 ballast 10 1 ballast 10 1 ballast 10 28

DAYIGHT IKED DIMMERS Automatically dims lights according to ambient light level to maintain a constant brightness of between 100 and 1000 lux (adjustable). For suspended or plasterboard ceilings. Complete with 2m cables for quick and easy installation. Daylight linked dimmers CEF PHDD DSI has dimming and on/off ing and is suitable for DSI dimmable ballasts. CEF PHDD DSI Photocell range: 100 to 1000 lux falling on the working plane oading: Total of ballast, lamps plus other not more than 6 amps including fluorescent. Can control up to 20 DSI ballasts See diagram 29 below 72mm diameter x 68mm For Manual high frequency dimmers please see pages 50 and 51. Manual wall retained for overriding OFF Enough daylight ighting OFF Reduced daylight ighting DIMMED ight ighting O Wiring diagram plan 29. CEF PHDD DSI controlling several DSI dimmable ballasts 65 2m cables 61 72 57 3 24 72 Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling CEF PHDD DSI (50Hz) S wall optional other * control lines D1 ballast D2 D1 ballast D2 D1 ballast D2 * Total of ballasts, lamps plus other not more than 6 amps 29

CEIIG PHOTOCE SWITCHES For saving lighting energy in offices, factories, sports halls and so on. For flush mounting through suspended or plasterboard ceilings. Complete with 2m cable for quick and easy installation. Ceiling flush-mounted photocell es CEF PH Switches the lights on when there is not sufficient ambient light available and off when there is sufficient ambient light available. Order codes: CEF PH CEF PHRE CEF PHRE This Re-set version es the lights off when there is sufficient ambient light but requires the wall to be operated in order to on. In this way the lights only on when demanded. Built-in differential ensures the artificial lights do not affect the photocell. Built-in time delay of 1 minute avoids unnecessary ing. Photocell range: oading: Switches on at between 100 and 1000 lux falling on the working plane Up to 6 amps (1500W) of resistive, fluorescent or transformer lighting s See diagram 30 below CEF PH and CEF PHRE: 72mm diameter x 68mm Enough daylight ighting OFF ight ighting O Manual wall retained for overriding OFF (and for re-setting CEF PHRE) Wiring diagram CEF PH, CEF PHRE 2m cable 66 55 24 30. Ceiling photocell manual wall for overriding off photocell S 60 3 72 72 Requires 63 or 64mm (2.5") diameter hole in a false or plasterboard ceiling 30

CEIIG PHOTOCE SWITCHES For saving lighting energy in offices, factories, sports halls and so on. For surface mounting onto solid ceiling. Ceiling surface-mounted photocell es CEPH O Switches the lights on when there is not sufficient ambient light available and off when there is sufficient ambient light available. Order codes: CEPH O CEPH RE Requires socket, order code: CESO SQ or CESO (see page 17) CEPH RE This Re-set version es the lights off when there is sufficient ambient light but requires the wall to be operated in order to on. In this way the lights only on when they are demanded. Built-in differential ensures the artificial lights do not affect the photocell. Built-in time delay of 1 minute avoids unnecessary ing. CEPH O and CEPH RE: Photocell range: oading: Plug into CESO SQ Ceiling socket (or CESO Ceiling socket). CESO SQ can be mounted on a square pattress box (or CESO can be mounted on a BESA box). Switches on at between 100 and 1000 lux falling on the working plane Up to 6 amps (1500W) of resistive, fluorescent or transformer lighting s See diagrams 31a and 31b below CEPH O and CEPH RE: 88 x 88 x 47mm Ceiling surface mounted versions: CESF O and CESF PHRE are also available on request. Enough daylight ighting OFF ight ighting O Manual wall retained for overriding OFF (and for re-setting CEPH RE) Wiring diagrams CEPH O, CEPH RE plan 88 88 (CESO SQ) 47 31a. Ceiling photocell 31b. Ceiling mounted socket (CESO SQ or CESO) for CEPH O or CEPH RE manual wall for overriding off photocell S Pattress box or BESA box S CESO SQ or CESO CEPH O or CEPH RE luminaire S ot to scale 31

TIME AG SWITCHES Selecting the appropriate time lag 2 wire versions o neutral wire needed 3 wire versions ive, neutral and ed line Slave es (normally open push buttons) Adjustable time lags: 1-10 minutes 1-120 minutes 2-20 minutes 1-120 minutes 12-120 minutes* Exterior: versions EXTSW EXTSW 16A Single push button These electronic time lag es are designed to lights, or other s O, and then to them OFF automatically after the set time lag has elapsed. Their energy saving benefits make these es ideal for use in stairwells, store rooms and in many other applications. Functions Activated by pressing the push button or touch pad. The time lag settings can be adjusted by a spindle on the bottom edge of the product. The adjustment spindle is in the waterproof housings for the exterior time lag es. The interior time lag es can be used for multi-way ing using the slave push buttons. Single illuminated push button Double push button Module for MK Grid Plus Module for MK Grid Plus, illuminated push button Module for Crabtree grid Module for Crabtree grid, illuminated push button Module for Eurodata plates TSW 10 TSW A20 TSW A120 SS 1S TSW 10 IM TSW A20 IM TSW A120 IM SS 2S GRT MK GRTA MK SSGS MK GRT MK IM GRTA MK IM GRT CB GRTA CB SSGS CB GRT CB IM GRTA CB IM GRT EU GRTA EU SSGS EU Module for Eurodata plates, illuminated push button Module for DETA and GET grids GRT EU IM GRTA EU IM GRT DT GRTA DT SSGS DT *TSW MS is selectable in 4 steps, 1/4 hour, 1/2 hour, 1 hour, 2 hours. Multi selectable time lag * TSW MS 32

TIME AG SWITCHES Exterior time lag es EXTSW EXTSW Ideal for energy saving control of exterior heaters and exterior lighting. Also suitable for damp areas indoors. Pressing the button brings the connected on. The is then ed off automatically after the time lag has elapsed. Illuminated push button for easy location in the dark. Tough, hard wearing, IP66 rated polycarbonate moulding. The time lag is adjustable from 2 to 20 minutes. Supply voltage: Weatherproof: 230VAC IP66 rating Maximum : 6 amps (1500W) of resistive. 2 amp (500W) of low energy lamps. 1 amp (250W) of fans. See diagrams 33a and 33b below 90 x 90 x 60mm Cable gland 90 90 5 17 60 24 24 EXTSW 16A Ideal for energy saving control of exterior heaters and exterior lighting. Also suitable for damp areas indoors. Pressing the touch sensitive area brings the connected on. The is then ed off automatically after the time lag has elapsed. Illuminated touch area for easy location in the dark. Tough, hard wearing, IP66 rated polycarbonate moulding. 120 24 24 90 Cable 5 gland 17 60 24 EXTSW 16A The time lag is adjustable from 2 to 20 minutes. Supply voltage: Weatherproof: Maximum : 230VAC IP66 rating 16 amps (4000W) of quartz heaters. 12 amps (3000W) of fluorescent. 2 amps (500W) of most metal halide lamps See diagrams 33a and 33b below 120 x 90 x 60mm Wiring diagrams 33a. Exterior time lag optional manual wall for overriding off Exterior time lag S 33b. Several exterior time lag es wired in parallel exterior time lag exterior time lag exterior time lag S S S 33

TIME AG SWITCHES Plated time lag es - 2 wire versions TSW 10, TSW 10 IM o neutral wire needed Direct replacements for existing wall es. o neutral wire is needed. Hence they are very quick and inexpensive to install. The TSW 10 IM has an illuminated push button for easy location in the dark. TSW 10 The time lag is adjustable from 1 to 10 minutes. Maximum : Minimum : Wiring diagrams: 6 amps (1500W) of resistive, fluorescent or transformer lighting s, or up to 1 amp (250W) of fans 40W of resistive, or for wiring in parallel 40W per time lag in the circuit. oad capacitors are now supplied to augment small or non-resistive s See page 35, diagrams 35a - 35f 86 x 86 x 12mm Wall box depth 16mm TSW 10 IM Slave push buttons These are normally open (push to make) push buttons. They can be used as slave es to operate a DAERS time lag, as shown in the appropriate wiring diagrams. SS 1S is a 1 gang version on a square plate. SS 2S is a 2 gang version, with 2 push buttons on a square plate. These square plated versions both fit into plaster depth (16mm) wall boxes. Dimensions as below. Also available as grid modules (for dimensions see below): SSGS MK for MK Grid Plus. Minimum wall box depth 35mm. SSGS CB for Crabtree grid. Minimum wall box depth 40mm. SSGS EU for Eurodata plates. Minimum wall box depth 35mm. SSGS DT for DETA and GET grids. Minimum wall box depth 40mm. TSW 10, TSW 10 IM, SS 1S, SS 2S SSGS MK SSGS CB SSGS EU SSGS DT 86 12 24 34 24 38 25 38 25 37 86 59 30 51 34 50 57 32 34

TIME AG SWITCHES Wiring diagrams - Plated time lag es - 2 wire versions 35a. Single time lag with no neutral wire (e.g. TSW 10) 35b. Several TSW 10 wired in parallel e.g. in a stairwell 35c. TSW 10 with slave push buttons time lag S time lag time lag time lag time lag S S S S 230VAC slave es (normally open push buttons) Circuit diagrams - Plated time lag es - 2 wire versions into 2-way circuit The circuit diagrams opposite illustrate a 2-way wiring configuration typical of those found on location. They also demonstrate how DAERS Plated time lag es (2-wire versions) and DAERS Slave es can be incorporated. 35d. Existing 2-way circuit S These circuit diagrams use the BS 7671:2001 harmonised colour coding with the triple-and-earth colours of brown, black and grey for the lines. For clarity all earth wires are omitted. They show the physical connections with or as appropriate. They use brown and blue for the line and neutral feeds to the circuit. They use twin-brown and earth for the feed to the first 2-way. Any unused wires are terminated with the x symbol. OTE: These circuits are only recommendations and the contractor remains responsible for their own work. 35e. Time lag es with no neutral wire, wired in parallel (minimum restrictions apply). To achieve minimum restriction, supplement one capacitor (CAPOAD) per TSW 10 (IM) as shown below. S S Time lag oad capacitor(s) if required 35f. Time lag with no neutral wire, with slave push buttons (minimum restrictions apply). To achieve minimum restriction, supplement one capacitor (CAPOAD) as shown below. Time lag S S Time lag As an alternative wiring method to avoid minimum restrictions use 3 wire Time lag es (eg. TSW A20), by using the spare strapper as a neutral (see circuit diagram 37e, page 37). S PB PB PB S PB Time lag PB Slave PB Slave oad capacitor PB = Slave push button connections As an alternative wiring method to avoid minimum restrictions use a 3 wire Time lag (e.g. TSW A20), by linking a neutral to the Time lag (see circuit diagram 37f, page 37). 35

TIME AG SWITCHES Plated time lag es - 3 wire versions These 3 wire versions are economical es which need neutral wires. The TSW A20 IM and TSW A120 IM have illuminated push buttons for easy location in the dark. Order codes: TSW A20 TSW A120 The time lags are adjustable: TSW A20: TSW A20 IM: TSW A120: TSW A120 IM: oading: Wiring diagrams: 2 to 20 minutes 2 to 20 minutes 12 to 120 minutes 12 to 120 minutes Up to 6 amps (1500W) of resistive, fluorescent or transformer lighting s, or up to 1 amp (250W) of fans. o minimum See page 37, diagrams 37a - 37f 86 x 86 x 12mm. Wall box depth 16mm Order codes: TSW A20 IM TSW A120 IM Slave push buttons These are normally open (push to make) push buttons. They can be used as slave es to operate a DAERS time lag, as shown in the appropriate wiring diagrams. SS 1S is a 1 gang version on a square plate. SS 2S is a 2 gang version, with 2 push buttons on a square plate. These square plated versions both fit into plaster depth (16mm) wall boxes. Dimensions as below. Also available as grid modules (for dimensions see below): SSGS MK for MK Grid Plus. Minimum wall box depth 35mm. SSGS CB for Crabtree grid. Minimum wall box depth 40mm. SSGS EU for Eurodata plates. Minimum wall box depth 35mm. SSGS DT for DETA and GET grids. Minimum wall box depth 40mm. TSW A20, TSW A120, TSW A20 IM, TSW A120 IM, SS 1S, SS 2S SSGS MK 24 34 SSGS CB 24 38 SSGS EU 25 38 SSGS DT 25 37 86 12 86 59 30 51 34 50 57 32 36

TIME AG SWITCHES Wiring diagrams - Plated time lag es - 3 wire versions 37a. Single time lag with neutral wire (e.g. TSW A20) 37b. Several time lag es with neutral wires, wired in parallel 37c. Time lag with neutral wire, with slave push buttons time lag S time lag time lag time lag time lag S S S S slave es (normally open push buttons) Circuit diagrams - Plated time lag es - 3 wire versions into 2-way circuit The circuit diagrams opposite illustrate a 2-way wiring configuration typical of those found on location. They also demonstrate how DAERS Plated time lag es (3-wire versions) and DAERS Slave es can be incorporated. OTE: Circuit diagrams 37d and 37e are also applicable to Grid time lag es (3 wire versions), see pages 40 and 41. 37d. Existing 2-way circuit S These circuit diagrams use the BS 7671:2001 harmonised colour coding with the triple-and-earth colours of brown, black and grey for the lines. For clarity all earth wires are omitted. They show the physical connections with or as appropriate. They use brown and blue for the line and neutral feeds to the circuit. They use twin-brown and earth for the feed to the first 2-way. Any unused wires are terminated with the x symbol. OTE: These circuits are only recommendations and the contractor remains responsible for their own work. 37e. Time lag es with neutral wire, wired in parallel (no minimum ) S Time lag S 37f. Time lag with neutral wire, with slave push buttons (no minimum ) Time lag S S Time lag S PB PB PB S Time lag PB Slave PB PB Slave PB = Slave push button connections 37

TIME AG SWITCHES These time lag es are in grid module formats. Grid time lag es - 2 wire versions For MK Grid Plus Order codes: GRT MK, GRT MK IM For Crabtree grid Order codes: GRT CB, GRT CB IM DAERS manufacture four versions, to suit each of the following formats, MK Grid Plus, Crabtree grid, Eurodata plates, Deta and GET grids. They may be placed in any position on the appropriate grid or plate. These Grid time lag es can be operated by slave push buttons, as listed on page 36 (see wiring diagrams 39b and 39e opposite). The GRT MK IM, GRT CB IM and GRT EU IM have illuminated push buttons for easy location in the dark. Time lag: 1 to 120 minutes (adjustable) Maximum : 6 amps (1500W) of resistive, fluorescent or transformer lighting s, or up to 1 amp (250W) of fans Minimum : 2W of resistive. A capacitor (order code CAPOAD) can be supplied to augment small or non-resistive s Wiring diagrams: See page 39, diagrams 39a-39e Module for MK Grid Plus: 59 x 24 x 34mm. Minimum wall box depth 35mm Module for Crabtree grid: 51 x 24 x 38mm. Minimum wall box depth 40mm Module for Eurodata plates: 50 x 25 x 38mm. Minimum wall box depth 35mm Module for Deta and GET grids: 57 x 25 x 37mm. Minimum wall box depth 40mm For Eurodata plates Order codes: GRT EU, GRT EU IM MK Grid Plus Crabtree Grid Eurodata plate Deta grid For Deta and GET grids Order codes: GRT DT GRT MK, GRT MK IM, SSGS MK Requires wall box depth of 35mm 24 GRT CB, GRT CB IM, SSGS CB Requires wall box depth of 40mm GRT EU, GRT EU IM, SSGS EU Requires wall box depth of 35mm 34 24 38 25 38 GRT DT, SSGS DT Requires wall box depth of 40mm 25 37 59 30 51 34 50 57 32 38

TIME AG SWITCHES Wiring diagrams - Grid time lag es - 2 wire versions 39a. Single Grid time lag with no neutral wire (e.g. GRT MK) 39b. Single Grid time lag with no neutral wire, with slave push buttons grid time lag S grid time lag S S 230VAC slave slave (normally open push buttons) Circuit diagrams - Grid time lag es - 2 wire versions into 2-way circuit The circuit diagrams opposite illustrate a 2-way wiring configuration typical of those found on location. They also demonstrate how DAERS Grid time lag es (2-wire versions) and DAERS Slave es can be incorporated. 39c. Existing 2-way circuit S These circuit diagrams use the BS 7671:2001 harmonised colour coding with the triple-and-earth colours of brown, black and grey for the lines. For clarity all earth wires are omitted. They show the physical connections with or as appropriate. They use brown and blue for the line and neutral feeds to the circuit. They use twin-brown and earth for the feed to the first 2-way. Any unused wires are terminated with the x symbol. OTE: These circuits are only recommendations and the contractor remains responsible for their own work. 39d. Grid time lag es with no neutral wire, wired in parallel To achieve minimum restriction, supplement one capacitor (CAPOAD) as shown below. S S Time lag oad capacitor if required 39e. Grid time lag with no neutral wire, with slave push buttons To achieve minimum restriction, supplement one capacitor (CAPOAD) as shown below. Time lag S S Time lag S S S S S Time lag Slave Slave oad capacitor if required S = Slave push button connections 39

TIME AG SWITCHES These time lag es are in grid module formats. Grid time lag es - 3 wire versions For MK Grid Plus Order codes: GRTA MK, GRTA MK IM For Crabtree grid Order codes: GRTA CB, GRTA CB IM DAERS manufacture four versions, to suit each of the following formats, MK Grid Plus, Crabtree grid, Eurodata plates, Deta and GET grids. They may be placed in any position on the appropriate grid or plate. These Grid time lag es can be operated by slave push buttons, as listed on page 36 (see wiring diagrams 41b opposite and 37d and 37e on page 37). The GRTA MK IM, GRTA CB IM and GRTA EU IM have illuminated push buttons for easy location in the dark. Time lag: 1 to 120 minutes (adjustable) Maximum : 6 amps (1500W) of resistive, fluorescent or transformer lighting s, or up to 1 amp (250W) of fans. Minimum : 2W of resistive. A capacitor (CAPOAD) can be supplied to augment small s such as contactors, low energy lamps, EDs and emergency light fittings Wiring diagrams: See page 41, diagrams 41a and 41b, also see page 37, diagrams 37d and 37e Module for MK Grid Plus: 59 x 24 x 34mm. Minimum wall box depth 35mm Module for Crabtree grid: 51 x 24 x 38mm. Minimum wall box depth 40mm Module for Eurodata plates: 50 x 25 x 38mm. Minimum wall box depth 35mm Module for Deta and GET grids: 57 x 25 x 37mm. Minimum wall box depth 40mm For Eurodata plates Order codes: GRTA EU, GRTA EU IM MK Grid Plus Crabtree Grid Eurodata plate Deta grid For Deta and GET grids Order codes: GRTA DT GRTA MK, GRTA MK IM Requires wall box depth of 35mm 24 34 GRTA CB, GRTA CB IM Requires wall box depth of 40mm 24 38 GRTA EU, GRTA EU IM Requires wall box depth of 35mm 25 38 GRTA DT Requires wall box depth of 40mm 25 37 59 30 51 34 50 57 32 40

TIME AG SWITCHES Wiring diagrams - Grid time lag es - 3 wire versions 41a. Single grid time lag with neutral wire (e.g. GRTA MK) grid time lag S 41b. Several grid time lag es with neutral wires, wired in parallel grid time lag grid time lag grid time lag See page 37 for circuit diagrams 37d and 37e of Grid time lag es (3 wire versions) into a 2-way circuit. S S S Multi-selectable time lag For multi-selectable control of electric s (including heating s). Switches on for a limited time only. Pressing the button selects each time lag choice in turn. The then remains on for the chosen time lag before ing off automatically. The button can also be used at any time for selecting a different time lag or for ing off. Bespoke versions are available on request. TSW MS Selectable time lag: oading: 1/4 hour, 1/2 hour, 1 hour, 2 hours Up to 13 amps (3000W) of resistive, or 6 amps (1500W) of transformer See diagram 41c below 86 x 86 x 12mm. Wall box depth: 25mm A Heater boost (order code: TSW HB) is also available, see page 53 for details. TSW MS Wiring diagram 41c. Multi-selectable time lag 86 12 TSW MS 86 41

OUTDOOR SECURITY SWITCHES An outdoor PIR which turns on lights at night when somebody approaches. Welcomes friends and deters intruders. Ideal for security and convenience. A compact design for controlling new or existing outdoor lights. Compact person detector Functions and features Switches lights on when somebody is detected. Switches lights off when nobody has been detected for a chosen period. The photocell can be set so that lights do not on during the day. Compact polycarbonate moulding. COPD Weatherproof: Detection range: Detection angle: 120 Time lag: Photocell range: oading: IP54 rating Up to 10m 2 to 20 minutes (adjustable) 10 lux to infinite lux (adjustable) Up to 6 amps (1500W) incandescent or mains halogen lamps. Up to 4 amps (1000W) electronic or wire wound transformers, fluorescent lamps (high frequency or soft start). Up to 2 amps (500W) compact fluorescent or ED lamps. Up to 1 amp (250W) most fans and metal halide discharge lamps. See diagram 42 below 75 x 60 x 37mm A version without a photocell is also available on request (order code: COPD XPH). Wiring diagram Detection diagram 42. COPD outdoor PIR Exterior wall mounted PIR Recommended mounting height between 1 and 2.2m 60 37 20mm threaded entry spout 65 10 24 24 optional manual for overriding off COPD S Strong detection zone (5m) Secondary detection zone (10m) 42

OUTDOOR SECURITY SWITCHES Twilight and Dusk es Twilight : TWSW Switches outdoor lights on at dusk and off at dawn. Ideal for all night security. Features Adjustable photocell. Compact polycarbonate moulding. Vandal resistant. TWSW Weatherproof: Photocell range: oading: IP54 rating 10 lux to 300 lux (adjustable) Up to 6 amps (1500W) incandescent or mains halogen lamps. Up to 4 amps (1000W) electronic or wire wound transformers, fluorescent lamps (high frequency or soft start). Up to 2 amps (500W) compact fluorescent or ED lamps. Up to 1 amp (250W) most fans and metal halide discharge lamps. See diagram 43 below 75 x 60 x 37mm Dusk : DUSW Switches lights on at dusk and off after a chosen period. Ideal for outdoor lighting during the evening, for security and convenience. Features Adjustable photocell. Adjustable time lag before ing off. Compact polycarbonate moulding. Vandal resistant. DUSW Weatherproof: Photocell range: Time lag: oading: IP54 rating 10 lux to 300 lux (adjustable) 2 to 16 hours (adjustable) Up to 6 amps (1500W) incandescent or mains halogen lamps. Up to 4 amps (1000W) electronic or wire wound transformers, fluorescent lamps (high frequency or soft start). Up to 2 amps (500W) compact fluorescent or ED lamps. Up to 1 amp (250W) most fans and metal halide discharge lamps. See diagram 43 below 75 x 60 x 37mm Wiring diagram TWSW Twilight 60 65 37 DUSW Dusk 17 5 10 24 24 Cable gland 43. Outdoor photocell es TWSW or DUSW optional manual for overriding off DAERS control S 20mm threaded entry spout 10 24 24 65 60 37 43

TRAIIG EDGE DIMMERS Quiet grid dimmer modules These dimmers can be used to dim lights from several locations. They are suitable for dimming mains and/or dimmable transformer low voltage lamps. Functions and Special features Slim buttons give an easy press action. Pressing the button dims or brightens the light to any level. A quick press es off. Another press returns the lamp to its previous brightness. All versions are suitable for dimming most mains dimmable ED lamps and fittings and mains halogen (e.g. GU10) lamps. Quiet operation. The soft start feature prolongs the lamp life. Some ED lamps may require a small resistive (order code RESOAD) to enable smooth dimming. For an up to date list of ED lamps and fittings tested with DAERS dimmers, please visit the DAERS website www.danlers.co.uk Multi-way ing and dimming can be achieved from any position only by using the complementary DAERS slave es. These grid dimmer modules fit any position on the appropriate grid or plate system. D I M M MUTI E D D I M M I G POIT QUIET I G O P E R AT I O Dimmer module for MK Grid Plus. 24 34 Dimmer module for Crabtree grid. 24 38 Dimmer module for Eurodata plates. 25 38 Dimmer module for Deta and GET grids. 25 37 59 30 51 34 50 57 32 44

TRAIIG EDGE DIMMERS Quiet grid dimmer modules Order code Min. and Max. wattage Resistive, mains halogen or dimmable electronic transformer s Min. and Max. wattage Dimmable wire-wound or toroidal transformer inductive s Min. and Max. wattage ED lamps and fittings* Wall box depth (mm) DQDGD MK400W 10 400W ot suitable 10 200W* 35 DQDGD CB400W 10 400W ot suitable 10 200W* 40 DQDGD EU400W 10 400W ot suitable 10 200W* 35 DQDGD DT400W 10 400W ot suitable 10 200W* 40 For MK Grid Plus DQDGD MK400W * Can vary depending ED lamp characteristics. For ing of Grid dimmers on multi-gang plates the following limits also apply: 2 gang plates: Maximum for total plate 630W 3 or 4 gang plates: Maximum for total plate 1000W 6, 8, 9 or 12 gang plates: Maximum per row 1000W 18 or 24 gang plates: Maximum per row 1200W Dimensions Module for MK Grid Plus: Module for Crabtree grid: Module for Eurodata plates: Module for Deta and GET grids: 59 x 24 x 34mm, minimum wall box depth of 35mm 51 x 24 x 38mm, minimum wall box depth of 40mm 50 x 25 x 38mm, minimum wall box depth of 35mm 57 x 25 x 37mm, minimum wall box depth of 40mm For Crabtree grid DQDGD CB400W 2-wire and intermediate wiring can be used with DAERS Quiet grid dimmers (see page 47) however all 2-way and intermediate es must be changed to DAERS Slave es SSGS or SS_S. Wiring diagrams 45a. Example of an existing 2-way circuit 45b. Replace the 2-way es with a Dimmer and a Slave, as shown S V dimmer For Eurodata plates DQDGD EU400W DAERS slave 45c. Multi-way ing and dimming (lights can be ed and dimmed from any position) S V dimmer DAERS slave DAERS slave For Deta and GET grids DQDGD DT400W 45

EADIG EDGE DIMMERS Soft start dimmers Order codes: DSS1D 250W, DSS1D 400W These dimmers can be used to dim lights from several locations. They are suitable for dimming resistive lamps, dimmable transformer low voltage lamps. Functions Slim buttons give an easy press action. Pressing the button dims or brightens the light to any level. A quick press es off. Another press returns the lamp softly to its previous brightness. These dimmers can also be used to control the speed of fans and motors. Special Features All versions are suitable for mains halogen* (e.g. GU10) lamps without the need for derating. *Mains halogen lamps must have an integral thermal safety fuse. The soft start feature prolongs the lamp life. Multi-way ing and dimming can be achieved from any position only by using the complementary DAERS slave es (see page 47). The grid module versions fit any position on the appropriate grid or plate system. These dimmers automatically off in the event of transformer malfunction, helping to protect the dimmer and the transformer. Dimensions Square plates: Module for MK Grid Plus: Module for Crabtree grid: Module for Eurodata plates: Module for Deta and GET grids: MUTI D I M M POIT 86 x 86 x 12mm, see table below for wall box depths 59 x 24 x 34mm, minimum wall box depth of 35mm 51 x 24 x 38mm, minimum wall box depth of 40mm 50 x 25 x 38mm, minimum wall box depth of 35mm 57 x 25 x 37mm, minimum wall box depth of 40mm I G Order codes: DSS2D 250W Order code Min. and Max. wattage Resistive, mains halogen or dimmable electronic transformer s Min. and Max. wattage Dimmable wire-wound or toroidal transformer inductive s Max. o. of transformers Wall box depth (mm) DSS1D 250W 40 250W 40 160W 4 16 DSS1D 400W 60 400W 60 250W 6 16 DSS2D 250W 40 250W /gang 40 160W /gang 4/gang 16 DSSGD MK400W 40 400W 40 250W 6 35 DSSGD CB400W 40 400W 40 250W 6 40 DSSGD EU400W 40 400W 40 250W 6 35 For MK Grid Plus (above left) DSSGD MK400W For Crabtree grid (above right) DSSGD CB400W DSSGD DT400W 40 400W 40 250W 6 35 For ing of Grid dimmers on multi-gang plates the following limits also apply: 2 gang plates: Maximum for total plate 630W 3 or 4 gang plates: Maximum for total plate 1000W 6, 8, 9 or 12 gang plates: Maximum per row 1000W 18 or 24 gang plates: Maximum per row 1200W Wiring diagrams: See diagrams 47a - 47d on page 47 Square plated dimmer es (1 gang illustrated) ights can be ed AD dimmed from several locations. For Eurodata plates (above left) DSSGD EU400W, 86 12 For Deta and GET grids (above right) DSSGD DT400W 86 46

DIMMERS Wiring diagrams - Quiet dimmers and Soft start dimmers (plated and grid) 2-WAY CIRCUIT ITERMEDIATE CIRCUIT 47a. Existing 2-way circuit 47e. Existing intermediate circuit S S 47b. Dimming circuits with 2-way ing and dimming 47f. Dimming circuits with multi-way ing and dimming slave S S V dimmer slave S slave S V S dimmer ATERATIVE 2-WAY CIRCUIT 47c. Existing alternative 2-way circuit ATERATIVE ITERMEDIATE CIRCUIT 47g. Existing alternative intermediate circuit S S 47d. Alternative dimming circuits with 2-way ing and dimming 47h. Alternative dimming circuits with multi-way ing and dimming V S dimmer S DAERS slave dimmer S V S DAERS slave S DAERS slave Slave push buttons These are normally open (push to make) push buttons. They can be used as slave es to operate a DAERS Soft start dimmer, as shown in the appropriate wiring diagrams. SS 1S is a 1 gang version on a square plate. SS 2S is a 2 gang version, with 2 push buttons on a square plate. These square plated versions both fit into plaster depth (16mm) wall boxes. Dimensions as below. Also available as grid modules (for dimensions see below): SSGS MK for MK Grid Plus. Minimum wall box depth 35mm. SSGS CB for Crabtree grid. Minimum wall box depth 40mm. SSGS EU for Eurodata plates. Minimum wall box depth 35mm. SSGS DT for DETA and GET grids. Minimum wall box depth 40mm. 47

EADIG EDGE DIMMERS Rotary and push dimmers A range of dimmers with elegant styling. Dim lights to any brightness. Versions are available for tungsten s and dimmable low voltage transformer s. All versions are suitable for mains halogen* (e.g. GU10) lamps without the need for derating. *Mains halogen lamps must have an integral thermal safety fuse. Material: Rotary dimmers: Push dimmers: White polycarbonate Rotary on/off ing, rotary dimming control. 1 way only Push on, push off, with rotary dimming control. 1 or 2 way ing Square plates: 86 x 86 x 12mm, see below See tables on page 49 for wall box depths Rectangular plates: 146 x 86 x 12mm, see below See tables on page 49 for wall box depths Square plated dimmer es (1 gang illustrated) Rectangular plated dimmer es (4 gang illustrated) 86 12 146 12 86 86 48

EADIG EDGE DIMMERS Rotary and push dimmers Tungsten rotary dimmers, 1 way Suitable for resistive s. Suitable for mains halogen lamps* without the need for derating. *Mains halogen lamps must have an integral thermal safety fuse. umber of gangs Order code Min. and Max. wattage Max. o. of transformers 1 DR1D 250W 40 250W - 16 1 DR1D 400W 60 400W - 16 2 DR2D 250W 40 250W/gang - 16 Wall box depth (mm) Tungsten push dimmers, 2 way Suitable for resistive s. Suitable for mains halogen lamps* without the need for derating. *Mains halogen lamps must have an integral thermal safety fuse. 1 DP1D 250W 40 250W - 16 1 DP1D 400W 60 400W - 16 1 DP1D 630W 60 630W - 40 1 DP1D 1000W 100 1000W - 25 2 DP2D 250W 40 250W/gang - 16 3 DP3D 250W 40 250W/gang - 16 4 DP4D 250W 40 250W/gang - 16 ow voltage push dimmers, 2 way For dimmable wire-wound transformer inductive s. 1 DP1D 250WI 60 250W 6 16 1 DP1D 400WI 60 400W 8 40 1 DP1D 630WI 60 630W 12 25 2 DP2D 160WI 40 160W/gang 4/gang 16 ow voltage push dimmers, 2 way For dimmable electronic transformer s. 1 DP1D 250WIET 40 250W 4 16 1 DP1D 400WIET 60 400W 6 16 1 DP1D 630WIET 60 630W 8 40 1 DP1D 1000WIET 60 1000W 12 25 2 DP2D 250WIET 40 250W/gang 4/gang 16 3 DP3D 250WIET 40 250W/gang 4/gang 16 4 DP4D 250WIET 40 250W/gang 4/gang 16 Push, 2 way On/off to match Rotary and push dimmer range. 1 or 2 way ing. 1 DP1S 1500W 0-1500W /A 16 49

MAUA HIGH FREQUECY DIMMERS High frequency controllers (plated) Push on, push-off, with rotary dimming control. DP1D 10VDC SB: For one or two dimmable ballasts with 1-10VDC input oading: See diagram 50a below Total of ballast, lamps plus other not more than 6 amps including fluorescent. 86 x 86 x 12mm. Wall box depth 16mm Order codes: DP1D 10VDC SB DP1D 10VDC MB DP1D DSI DP1D 10VDC MB: For multiple dimmable ballasts with 1-10VDC input oading: See diagram 50b below Total of ballast, lamps plus other not more than 6 amps including fluorescent. Can control up to 20mA, eg. 20 ballasts at 1mA. (Control current of ballast is usually specified at 1-10V terminals.) 86 x 86 x 12mm. Wall box depth 16mm DP1D DSI: oading: For multiple DSI dimmable ballasts See diagram 50c below Total of ballast, lamps plus other not more than 6 amps including fluorescent. Can control up to 20 DSI ballasts 86 x 86 x 12mm. Wall box depth 35mm. Dimensions (in mm) and wiring diagrams DP1D 10VDC SB, DP1D 10VDC MB, DP1D DSI 86 12 50a. DP1D 10VDC SB dimming a single 1-10VDC ballast (optional multi-way ing illustrated) Optional 2-way Optional intermediate (es) 1 2 S DP1D 10VDC SB control lines 1 ballast 10 86 optional other * * Total of ballast(s), lamps plus other not more than 6 amps 50b. DP1D 10VDC MB dimming several 1-10VDC ballasts (optional multi-way ing illustrated) Optional 2-way Optional intermediate (es) 1 2 DP1D 10VDC MB optional other * S control lines 1 ballast 10 1 ballast 10 1 ballast 10 * Total of ballasts, lamps plus other not more than 6 amps 50c. DP1D DSI dimming several DSI ballasts (optional multi-way ing illustrated) Optional 2-way 1 2 Optional DP1D DSI intermediate (es) S optional other * control lines D1 ballast D2 D1 ballast D2 D1 ballast D2 * Total of ballasts, lamps plus other not more than 6 amps 50

MAUA HIGH FREQUECY DIMMERS High frequency controllers (grid modules) Suitable for dimmable ballasts with 1-10VDC input. Push on, push off, hold to dim. Versions to suit the MK Grid Plus, Crabtree grid, Eurodata plates, Deta and GET grids. They may be placed in any position on the appropriate grid or plate. They can also be operated by additional mains rated, normally open retractive es. Please call for details. For MK Grid Plus DSSGD MK 10VDC oading: See diagram 51 below Total of ballast, lamps plus other not more than 6 amps including fluorescent. Can control up to 20mA, eg. 20 ballasts at 1mA. When controlling ED drivers a capacitor (order code CAPOAD) may be required to augment the Module for MK Grid Plus: 59 x 24 x 34mm. Minimum wall box depth 35mm Module for Crabtree grid: 51 x 24 x 38mm. Minimum wall box depth 40mm Module for Eurodata plates: 50 x 25 x 38mm. Minimum wall box depth 35mm Module for Deta and GET grids: 57 x 25 x 37mm. Minimum wall box depth 40mm For Crabtree grid DSSGD CB 10VDC Dimensions (in mm) and wiring diagram DSSGD MK 10VDC Requires wall box depth of 35mm 24 34 DSSGD CB 10VDC Requires wall box depth of 40mm 24 38 59 30 51 34 For Eurodata plates DSSGD EU 10VDC DSSGD EU 10VDC Requires wall box depth of 35mm 25 50 38 DSSGD DT 10VDC Requires wall box depth of 40mm 25 57 32 37 For Deta and GET grids DSSGD DT 10VDC 51. DSSGD MK 10VDC, DSSGD CB 10VDC, DSSGD EU 10VDC, DSSGD DT 10VDC dimming several 1-10VDC ballasts Optional mains rated, normally open push button(s) High frequency grid dimmer module R S optional other * control lines 1 ballast 10 1 ballast 10 1 ballast 10 * Total of ballasts, lamps plus other not more than 6 amps 51

HVAC COTROS (for Heating, Ventilation and Air Conditioning) PIR thermostat controls WAPIR TH PIR thermostat control for heating: WAPIR TH (user adjustable) PIR thermostat control for heating: WAPIR THX (hidden adjustment) For the automatic control of electric heating s. The passive infra-red person detector detects whether somebody is present in the vicinity. If somebody is present the heating is controlled by the thermostat. If nobody is present the room temperature is allowed to drop to a lower base level. This base level or set-back temperature is also adjustable. WAPIR TH has an adjustable thermostat dial. WAPIR THX does not have an adjustable dial. The thermostat setting is adjusted to the preferred setting by use of a spindle on the back of the product. For wall mounting only. Detection angle: 120, see page 21 (as WAPIR) Thermostat range: 15 to 25ºC Set-back temperature: 5 to 14ºC oading: Up to 13 amps (3000W) of any type of resistive heating See diagram 52 below 86 x 86 x 22mm. Wall box depth: 25mm WAPIR THX WAPIR TC PIR thermostat control for cooling: WAPIR TC (user adjustable) PIR thermostat control for cooling: WAPIR TCX (hidden adjustment) For the automatic control of electric cooling s. The passive infra-red person detector detects whether somebody is present in the vicinity. If somebody is present the cooling is controlled by the thermostat. There is a deadzone adjustment and a run-on time adjustment to avoid excessive ing of the cooling. If nobody is present the cooling thermostat remains off until the room temperature reaches its upper threshold. This upper threshold is set using the offset temperature adjustment. WAPIR TC has an adjustable thermostat dial. WAPIR TCX does not have an adjustable dial. The thermostat setting is adjusted to the preferred setting by use of a spindle on the back of the product. For wall mounting only. Detection angle: Thermostat range: 15 to 25ºC Offset temperature: 120, see page 21 (as WAPIR) Deadzone adjustment: 1, 2, 3, 4 or 5ºC Run-on time: oading: Differential of 2 to 10ºC above main thermostat setting or disabled 0 minutes or 5 minutes Up to 13 amps (3000W) of any type of resistive cooling See diagram 52 below 86 x 86 x 22mm. Wall box depth: 25mm WAPIR TCX WAPIR TH, WAPIR THX, WAPIR TC, WAPIR TCX 86 22 Wiring diagram 52. PIR Thermostat controlling a heating or cooling DAERS control S 86 52

HVAC COTROS (for Heating, Ventilation and Air Conditioning) Heater boost TSW HB For control of electric heating s (or other electric s). Switches heating on for a limited time only. Pressing the button selects each time lag choice in turn. The heating then remains on for the chosen time lag before ing off automatically. The button can also be used at any time for selecting a different time lag or for ing off. Bespoke versions are available on request. Selectable time lag: oading: 1/4 hour, 1/2 hour, 1 hour, 2 hours Up to 13 amps (3000W) of resistive, or 6 amps (1500W) of transformer See diagram 53a below 86 x 86 x 12mm. Wall box depth: 25mm A Multi-selectable time lag (TSW MS) is also available, see page 41 for details. Fan speed control Controls the speed of fans and small motors. Push-on, push-off with rotary speed control. Can be used in one or two way ing circuits. ot suitable for control of fans or motors which are synchronous (designed to be constant speed). FASP Minimum : Maximum : 40W 250W See diagrams 53b and 53c below 86 x 86 x 12mm. Wall box depth: 16mm TSW HB FASP 86 12 86 12 86 86 Wiring diagrams 53a. Heater boost controlling a heating 53b. Fan speed control in 1-way ing circuit 53c. Fan speed control in 2-way ing circuit TSW HB S FASP V FASP V 53

RADIO REMOTE COTROS These products are used for the remote control ing or dimming of lighting or other s. The wire-free senders are available as hand held or wall mounted versions. A receiver or receiver dimmer is wired into the existing circuit to control the connected. The sender signals can pass through walls or ceilings so the receivers can be mounted out of sight. In a typical building the receivers can work at an approximate range of 30-50 metres. In free air the range is approximately 100-150 metres. The carrier frequency of the radio signals is 868MHz, which is CE Approved and icence Free. A EXAMPE BUIDIG Radio receivers Exterior receiver for out lights. Radio remote control senders and receivers Display cabinet lamps or standard desk lamps can be controlled via a plug-in dimmer receiver. Receiver es and receiver dimmers for the lighting circuits can be concealed behind a false ceiling. Wire-free radio senders 12 channel hand sender to control ceiling lights, spot lights and screen. For security reasons a caretaker can use another 12 channel hand sender to control all the lights in the building and the out security lights. All lights can also be controlled by wire-free wall mounted senders. 54

RADIO REMOTE COTROS Radio remote control functions Each button on each sender sends a unique coded signal (one of 4 billion codes). A simple set-up procedure enables any chosen receiver to respond to the signal from any chosen sender button. The sender button then controls the receiver (and its connected ). This simple procedure is repeated, creating links between various sender buttons and various receivers. As shown, almost any control set-up is possible; from a single room to an entire building. For the simplest set-up, one receiver can be controlled by one sender. Receiver Sender Any receiver can be programmed to respond to the unique coded signal from any sender button. Hence, a sender button can control any number of receivers simultaneously. Also a single receiver can be controlled by up to 15 sender buttons. These control combinations can be mixed and matched, making it possible to have almost any control set-up desired; from the simplest single room to an entire building. In the above control set-up, one button on the left hand sender controls the first receiver. A different button on the left hand sender controls the first and second receivers simultaneously, and so on. Typical penetration of radio signals The radio signals cannot pass through the entire length of walls. The radio signals achieve a range of approximately 30-50m in a building; 100-150m in free air. Brick walls: approx. 60-90% penetration Timber framework with sandwich plasterboards: approx. 80-95% penetration Reinforced concrete: approx. 20-60% penetration Metal walls: approx. 0-10% penetration Conventional glass: approx. 70-90% Insulating glass (with vaporised metal coat): approx. 30-60% penetration Plastics: approx. 80-95% penetration 55

RADIO REMOTE COTROS Radio remote control wire-free hand senders HASE 12RF 12 channel hand held sender Sends on 12 unique channels. Complete with two AAA batteries. Signal range: Carrier frequency: Up to 150m in free air 868MHz (CE Approved, icence Free) 120 x 57 x 24mm 57 120 24 1 channel hand held sender Sends on 1 unique channel. Complete with CR2430 battery. Signal range: Carrier frequency: Up to 100m in free air 868MHz (CE Approved, icence Free) 100 x 61 x 21mm 61 100 21 HASE 1RF 2 channel key fob sender Sends on 2 unique channels. Complete with CR2430 battery. With optional wall mounting fixing. Signal range: Carrier frequency: Up to 100m in free air 868MHz (CE Approved, icence Free) 86 x 46 x 16mm 46 86 16 HASE 2RF Radio remote control wire-free card operated wall sender WACC RFS Card operated wall sender Ideal for use in hotels, hospitals, restricted work areas etc. Sends on 1 unique channel. Complete with CR2477 battery. Signal range: Carrier frequency: Finishes: Up to 50m in free air 868MHz (CE Approved, icence Free) Please call for details 96 x 88 x 17mm, complete with dry line wall box, depth 35mm 96 88 17 Also available: Slave senders See page 63 for details. 56

RADIO REMOTE COTROS Radio remote control wire-free wall senders Wire-free. o wall box needed. Complete with CR2430 battery(ies). Wall senders can be mounted using the pre-fixed adhesive strips to any fixed surface. Signal range: Up to 100m in free air WASE 1RF WHI Carrier frequency: 868MHz (CE Approved, icence Free) 96 13 WASE 1RF WHI Sends on 1 unique channel. 96 x 88 x 13mm 88 WASE 2RF WHI Sends on 2 unique channels. 96 13 96 x 88 x 13mm 88 WASE 2RF WHI WASE 4RF WHI Sends on 4 unique channels. 169 x 88 x 13mm 169 13 88 WASE 4RF WHI Radio remote control wire-free external wall sender 1 channel external wall mounted sender Sends on 1 unique channel. o wall box needed. Complete with CR2430 battery. 90 60 90 Signal range: Up to 100m in free air Carrier frequency: 868MHz (CE Approved, icence Free) EXWASE 1RFDC Weatherproof: IP66 rating 90 x 90 x 60mm Hard wired, mains powered, external wall mounted sender available on request. EXWASE 1RFAC 57

RADIO REMOTE COTROS Radio receiver es WACE RFS CEF RFS CEVO RFS Wall or ceiling mounted : WACE RFS Hard wired. Can be mounted on a 16mm box. Can be mounted out of sight. oading: Up to 6 amps (1500W) of resistive or up to 1 amp (250W) of transformer or fluorescent See diagram 58 below 86 x 86 x 22mm Ceiling flush mounted : CEF RFS Complete with 2m cable for quick and easy installation. oading and wiring as for WACE RFS. Hard wired : CEVO RFS 72mm diameter x 68mm (requires 63mm diameter hole) Complete with 2m cable for quick and easy installation. Ideal for ceiling voids. Will fit through a 63mm diameter aperture. oading and wiring as for WACE RFS. 32 x 50 x 90mm plan 86 86 22 CERF S6A Requires socket, order code: CESO or CESO SQ (see page 62) Plug-in : CERF S6A Plugs into a Ceiling socket (shown on p.62). Can be mounted out of sight. oading: Up to 6 amps (1500W) of any type of, including fluorescent lights or up to 1 amp (250W) of fans See diagram 58 below 130 x 72 x 57mm Also available: Hard wired : CEVO RFS6A Complete with 2m cable for quick and easy installation. oading and wiring as CERF S6A. 130 x 72 x 57mm plan 72 130 57 DI RFS DI rail receiver : DI RFS For fixing on to either 35 x 7.5mm top-hat DI rail or 32 x 15mm G-type DI rail. oading: Up to 6 amps (1500W) of resistive or up to 1 amp (250W) of transformer or fluorescent See diagram 58 below 35 x 75 x 100mm DI rail receiver dimmer also available on request. plan 75 100 35 Wiring diagram 58. Remote control ing receiver S wire-free sender 58

RADIO REMOTE COTROS Radio receiver es Plug-in adaptor : PORF S8A Plugs into a UK 3-pin mains socket and has its own 3-pin socket for a mains powered plug-in device. Ideal for table lamps or displays. 60 48 PORF S8A oading: Wiring: Up to 8 amps (2000W) of resistive or up to 1 amp (250W) of transformer or fluorescent Plugs into 13 amp mains socket 138 x 60 x 48mm 138 Exterior : EXRFS Hard wired. Outdoor mounted. Weatherproof to IP65 rating. 98 35 oading: Up to 6 amps (1500W) of resistive or up to 1 amp (250W) of transformer or fluorescent 64 See diagram 59a below 98 x 64 x 35mm EXRFS WACE RF2S Dual momentary : WACE RF2S Hard wired. Wall or ceiling mounted. Twin actuator. Enables blinds to be opened, closed or adjusted to any position required. Can be mounted on a 16mm box. Can be mounted out of sight. WACE RF2S can also be used as a slave to control up to two DAERS grid time lag or soft start dimmer es. This can allow RF control of higher wattage s including toroidal transformers. oading: Up to 6 amps (1500W) of resistive or up to 1 amp (250W) of transformer or fluorescent See diagrams 59b and 59c below 86 x 86 x 22mm plan 86 86 22 Wiring diagrams 59a. Remote control ing receiver S 59b. Blind/motor control (high current) WACE RF2S S1 S2 Contactor 59c. Soft start dimmer with remote control WACE RF2S S S wire-free sender wire-free sender Contactor Down Motor Up Motor wire-free sender soft start dimmer V 59

RADIO REMOTE COTROS Radio receiver dimmers (trailing edge) WACE RFD250W Wall or ceiling mounted dimmer: WACE RFD250W Hard wired. Can be mounted on a 16mm box. Can be mounted out of sight. oading: Dimming technology: Trailing edge Up to 250W of resistive, mains halogen* or dimmable electronic transformer s See diagram 61a on page 61 86 x 86 x 22mm plan 86 86 22 CEF RFD250W Also available: Ceiling flush mounted dimmer: CEF RFD250W Complete with 2m cable for quick and easy installation. oading and wiring as for WACE RFD250W. 72mm diameter x 68mm (requires 63mm diameter hole) CEVO RFD250W Also available: Hard wired dimmer: CEVO RFD250W Complete with 2m cable for quick and easy installation. Ideal for ceiling voids. Will fit through a 63mm diameter aperture. oading and wiring as for WACE RFD250W. 32 x 50 x 90mm Plug-in adaptor dimmer: PORF D250W Plugs into a UK 3-pin mains socket and has its own 3-pin socket for a mains powered plug-in device. Ideal for table lamps or displays. oading: Dimming technology: Trailing edge Wiring: Up to 250W of resistive, mains halogen* or dimmable electronic transformer s Plugs into 13 amp mains socket 138 x 60 x 48mm 60 138 48 PORF D250W EXRF D250W Exterior dimmer: EXRF D250W Hard wired. Outdoor mounted. Weatherproof to IP65 rating. oading: Dimming technology: Trailing edge Up to 250W of resistive, mains halogen* or dimmable electronic transformer s See diagram 61a on page 61 98 x 64 x 35mm 98 64 35 *Mains halogen lamps must have an integral thermal safety fuse. 60

RADIO REMOTE COTROS Radio receiver dimmers (trailing edge) Plug-in dimmer: CERF D500W Plugs into a Ceiling socket (shown on p.62). Can be mounted out of sight. plan 72 57 CERF D500W oading: Dimming technology: Trailing edge Up to 500W of resistive, mains halogen* or dimmable electronic transformer s 130 See diagram 61a below 130 x 72 x 57mm Build-in dimmer: CERF D500W GT Ideal for building into a luminaire or gear tray. Hard wired build-in dimmer. oading: Dimming technology: Trailing edge Up to 500W resistive, mains halogen* or dimmable electronic transformer s See diagram 61a below 151 plan 151 34 28 CERF D500W GT 151 x 34 x 28mm Build-in dimmer: CERF D10VDC MB Ideal for building into a luminaire or gear tray. For controlling dimmable ballasts with a 1-10VDC analogue input. 151 plan 34 CERF D10VDC MB oading: Up to 6 amps (1500W) of resistive or up to 4 amps (1000W) of fluorescent. Total of ballasts, lamps plus other s not more than 2 amps. Can control up to 20mA, eg. 20 ballasts at 1mA. Dimming technology: 1 to 10V with relay off 151 28 See diagram 61b below 151 x 34 x 28mm Wiring diagrams 61a. Remote control dimming 61b. CERF D10VDC MB controlling several 1-10VDC dimmable ballasts *Mains halogen lamps must have an integral thermal safety fuse. wire-free sender receiver dimmer V CERF D10VDC MB wire-free sender S control lines 1 ballast 10 1 ballast 10 1 ballast 10 61

RADIO REMOTE COTROS Sockets and slave relays Ceiling socket: CESO For DAERS plug-in es or dimmers. Can be mounted on a BESA box. See diagram 62a below 74mm diameter x 13mm (CESO) plan 74 13 74 CESO CESO SQ Also available as a square socket. Ceiling socket: CESO SQ Can be mounted on a square pattress box. See diagram 62a below 87 x 87 x 13mm (CESO SQ) 87 87 plan 13 87 Ceiling slave relay: CES For DAERS plug-in es only. Provides an extra 1-pole isolated changeover contact. Enables the ing of an additional circuit with its own supply, e.g. the corridor lights out an office or a separate low voltage control circuit. plan 87 87 oading: (Each circuit) up to 6 amps (1500W) of resistive, fluorescent or transformer lighting s, or up to 1 amp (250W) of fans 87 41 CES See diagram 62b below 87 x 87 x 41mm Ceiling double slave relay: CE2S For DAERS plug-in es only. Provides extra 2-pole isolated changeover contacts. Enables the ing of two additional circuits, each with its own supply, e.g. the corridor lights out an office and the extractor fans in the office. Also ideal for ing two separate low voltage control circuits. plan 87 87 41 87 CE2S oading: (Each circuit) up to 6 amps (1500W) of resistive, fluorescent or transformer lighting s, or up to 1 amp (250W) of fans See diagram 62c below 87 x 87 x 41mm Wiring diagrams 62a. Ceiling mounted socket (CESO or CESO SQ) for plug-in ceiling controls BESA box or pattress box S CESO or CESO SQ plug-in ceiling control luminaire S ot to scale 62b. Plug-in control plus slave relay with volt free changeover contacts (CES) controlling one extra circuit 1 S2 /O separate circuit C2 S2 /C 1 optional manual CES S1 wall for plus overriding off plug-in 62c. Plug-in control plus double slave relay with volt free changeover contacts (CE2S) controlling two extra circuits 1 1 S2 /O separate circuit optional manual wall for overriding off C2 S2 /C S3 /O separate circuit CE2S plus plug-in C3 S1 S3 /C 62

RADIO REMOTE COTROS Slave radio senders For use with DAERS plug-in es, such as PIR occupancy es or Photocell es. For controlling other remote circuits via Radio receiver es or dimmers (shown on pages 58 to 61). The SSE 1RFSO is hard wired. Requires mains power supply. Sends on 1 unique channel. For programming, requires Test plug (order code TEP). plan 87 41 Signal range: Up to 100m in free air 87 SSE 1RFSO See diagram 63 below 87 x 87 x 41mm Wiring diagram 63. Radio slave sender and radio receiver DAERS plug-in SSE 1RFSO 1 Radio receiver 1 Also available on request: Outdoor 2 channel slave radio sender ( EXSSE 2RF). Customised functions and scene-setting By special order DAERS can supply packages of Senders and Receivers which are factory pre-programmed to perform specified special ing and/or dimming functions. The table lists some of the special functions that are available, plus examples of how these functions may be used. Even packages which perform several different functions can be supplied. Please note there is an additional charge to customise for special requirements and a charge for programming on site. Please call to discuss your particular requirements. Special ing function Time delay O Time delay OFF Time delay OFF with warning Momentary O Flashing Motor control Example application For a special stage effect A courtesy light for leaving a building Demand for lighting for few minutes in a stock cupboard, with flashing prompt to re-press the sender before the lights go out To sound a doorbell To give an alert signal (e.g. testing in progress) To open and close blinds, screens or shutters Special dimming function Gradual dimming or brightening Select a pre-set lamp brightness Gradual dim to pre-set level Soft start on Example application Theatre house lights or presentation rooms To set a mood for restaurant lighting To give comfortable background lighting in a conference To give a subtle on effect for a hotel room 63

ACTIVE IFRA-RED REMOTE COTROS For simple remote control set-ups with on/off ing, using Active infra-red hand held senders and wall or ceiling mounted receiver es. The hand senders have a range of approximately 10 metres line of sight. Infra-red remote control ing CEF AIR WACE AIR A mains supply interrupt for a few seconds can be used to reset the es to off. The CEF AIR can be flush mounted through a false or plasterboard ceiling. It has a 2m cable for quick and easy installation. The WACE AIR can be wall mounted or ceiling surface mounted on a 16mm (plaster depth) box. Multi-channel ing It is possible to have a multi-channel arrangement to control several different circuits of lights or other s. Each receiver would its own circuit. Each receiver can be set to receive on one of four channels (A, B, C or D). The hand senders work on different combinations of channels (as indicated in the order codes). oading: Up to 6 amps (1500W) of resistive, fluorescent or transformer lighting s, or up to 1 amp (250W) of fans. See diagram 64 below CEF AIR: 72mm diameter x 68mm WACE AIR: 86 x 86 x 22mm (CEF AIR) 65 2m cable 61 72 (WACE AIR) / plan 86 57 3 plan 72 Requires 63mm or 64mm (2.5") diameter hole in a false or plasterboard ceiling 86 24 22 Hand senders Range of approximately 10 metres line of sight. Hand senders send coded signals to the remote control es on and off. Available as 1, 2 and 4 channel versions with combinations of channels (A, B, C, D), as in order codes. Each hand sender requires two AA batteries. 61 100 21 100 x 61 x 21mm Order codes: HASE A HASE BC HASE ABCD Wiring diagram 64. Remote control ing receiver wire-free sender 64

ADDITIOA PRODUCTS Ceiling box Box suitable for ceiling socket. Ideal for ceiling mounting. Has a 20mm entry spout. plan 65mm diameter 24.5 29 24.5 65 65 CEBO Ceiling pattress box Box suitable for square ceiling products. Ideal for ceiling mounting. Has a 20mm knockout. plan 87 28 87mm x 87mm 87 internal depth 25mm PABO Test plug Tests a ceiling socket by linking the live and ed line terminals. plan 57 x 35.5 x 33mm 26 33 57 57 35.5 TEP oad resistor RESOAD can be used to try to eliminate lamp instability and flicker when dimming non-resistive s such as mains directly dimmable ED lamps or dimmable transformers. Plan view End view 15 58 35 RESOAD 80 x 58 x 50mm. Can be passed through a 63mm diameter cutout. 80 36 65

BESPOKE PRODUCTS Special versions of various DAERS products can be supplied to Original Equipment Manufacturers or other customers. Please call us to discuss your requirements. Here are some examples: ow voltage PIR occupancy es We manufacture various 24V (a.c. or d.c.) versions of our PIR occupancy es and photocell es, ideal for low voltage control systems. 12V versions can also be supplied, depending on the quantity required. Many of these items are often held in stock. Please see page 14 for some of the Ceiling flush mounted variants. To special order we can also supply PIR occupancy es with volt-free outputs (including versions with gold contact relays) available for use with mains, 24V or 12V supplies. The circuit diagrams on page 67 show how these products can be used. Pre-wired controls We can manufacture various bespoke pre-wired controls for use with marshalling box control systems as well as different cable lengths on standard products. ow voltage high frequency dimmers We can manufacture bespoke 1-10 volt PIR occupancy es with daylight linked dimming with 24V (a.c. or d.c.) supply. Bespoke time lag es Time lag es with bespoke specifications can be supplied, depending on the quantity required. The special features which can be supplied are: Different time lag ranges Fixed time lags Warning signal before is ed off (e.g. lighting flashing off and back on again 1 minute before off) Ability to manually off while part way through a time lag Different coloured illuminated push buttons Variants on the Heater boost (page 53) with different time lag options and/or different printing on the plate Designed to operate from different supply voltages With ed outputs or volt-free outputs. Adaptor box with plug We can also supply our square plated hard wired controls mounted on a special adaptor box with a plug, suitable for our Ceiling sockets (CESO and CESO SQ) and our Ceiling slave relays (CES and CE2S). DAERS control mounted on Adaptor box with plug Manufacturing services DAERS offer manufacturing services, including surface mount and through hole electronic assembly, for other manufacturers. Please contact us to discuss your requirements or visit DAERS Contract Electronics Manufacturing website: www.danlerscem.co.uk 66

BESPOKE PRODUCTS Switched output 67a. Standard products (230VAC supply) 67b. 24 Volt (AC or DC) supply 67c. 12 Volt (AC or DC) supply optional manual wall for overriding off DAERS control +24V optional manual wall for overriding off DAERS control +12V optional manual wall for overriding off DAERS control 24V (AC or DC) 12V (AC or DC) 0V 0V Volt-free output (including gold relay contacts for integrating into building management systems) 67d. 230VAC supply 67e. 24 Volt (AC or DC) supply 67f. 12 Volt (AC or DC) supply optional manual wall for overriding off DAERS control volt-free contacts +24V optional manual wall for overriding off DAERS control volt-free contacts +12V optional manual wall for overriding off DAERS control volt-free contacts 24V (AC or DC) 12V (AC or DC) 0V 0V Open collector Open collector output can be implemented with DAERS ogic Gold, Volt Free product variants. Relay contact material options STADARD: GOD: OGIC GOD: High voltage, high current High voltage, low current ow voltage, low current. 67

O.E.M. PRODUCTS Build-in PIR occupancy es DAERS manufacture bespoke passive infra-red occupancy es for manufacturers to build into luminaires. These are ideal for energy saving as they ensure that unnecessary lighting is ed off automatically. Please contact us to discuss your requirements. Each product contains a passive infra-red quad person detector, adjustable time lag (before off), adjustable photocell and a relay suitable for ing lighting s. The products require a neutral connection. Please also refer to pages 22-23 for PIR occupancy Eurodata grid modules. Please also refer to pages 19, 24-25 for some of DAERS solutions for warehouses and storage aisles. Typical specification Person detector: Time lag range: Photocell range: oading: Typical mounting heights: Passive infra-red quad detector Adjustable time lag settings Adjustable photocell settings Up to 6 amps (1500W) of resistive, transformer or fluorescent lighting s, 2 amps (500W) of low energy lighting s (ED lamps and compact fluorescent) or up to 1 amp (250W) of fans or most metal halide lamps 5m, 10m, 12m, 20m A mounting bezel (order code GREUW BEZE) is available for mounting Eurodata grid modules. Example detection patterns The examples below could be used in warehouses, storage facilities and other applications Mounting height up to 5m 120 Mounting height up to 12m Mounting height up to 20m Up to 7m 6 Mounting height up to 10m Up to 20m up to 3m Up to 12m 2m Up to 15m 2m 68

O.E.M. PRODUCTS Soft start dimmer modules Description Soft start dimmer module Same functions and features as the plated Soft start dimmers, shown on page 46. For wiring diagrams see page 45 (diagrams 45a-45c). Flush soft start dimmer module Same functions and features as the plated Soft start dimmers, shown on page 46. For wiring diagrams see page 45 (diagrams 45a-45c). Quiet dimmer module Same functions and features as the quiet grid dimmer modules, shown on page 45. For wiring diagrams see page 45 (diagrams 45a-45c). Order code Min. and Max. wattage: resistive, mains halogen or dimmable electronic transformer s Min. and Max. wattage: dimmable wire-wound or toroidal transformer inductive s Max. no. of transformers Dimensions (mm) DSS 250W 40-250W 40 160W 4 66x28x29 DSS 400W 60 400W 60 250W 6 66x28x29 DSS F 250W 40-250W 40 160W 4 65x26x25 DSS F 400W 60 400W 60 250W 6 45x24x38 DQD F 400W 40 400W ot suitable 6 45x24x38 Slave module SS S Suitable for use with DAERS Soft start dimmers 66x28x29 and Quiet dimmers and modules, and DAERS Flush slave module SS F S Time lag es. 45x24x38 High frequency dimmer modules Description Order code oad / umber of ballasts Dimensions (mm) Push on, push off, with rotary dimming control For dimmable high frequency ballasts taking a 1-10VDC input. Based on 1-10VDC High frequency plated dimmers shown on page 50. For wiring diagrams see page 50 (diagrams 50a-50b). DPD 10VDC SB DPD 10VDC MB 1 or 2 ballasts. Total of ballasts, lamps plus other not more than 6 amps. Total of ballasts, lamps plus other not more than 6 amps. Can control up to 20mA, eg. 20 ballasts at 1mA. Multiple ballasts (varies according to make and model of ballast). 64x25x21 + terminal block 64x26x28 Flush high frequency dimmer module For dimmable high frequency ballasts taking a 1-10VDC input. Based on 1-10VDC High frequency grid dimmers shown on page 51. For wiring diagrams see page 51 (diagram 51). DSS F 10VDC Total of ballasts, lamps plus other not more than 6 amps. Can control up to 20mA, eg. 20 ballasts at 1mA. (Varies according to make and model of ballast) 45x24x38 DSS 250W, DSS 400W, SS S DSS F 400W, DQD F 400W, SS F S, DSS F 10VDC DPD 10VDC SB DPD 10VDC MB 28 24 24 38 2 way terminal block on flying leads 25 21 26 24 66 45 64 64 Spindle Ø = 6mm 29 Spindle Ø = 6mm Spindle Ø = 6mm 28 DSS DPD F 10VDC 250WMB 26 25 65 69

O.E.M. PRODUCTS Dimmer modules and time lag modules are available for other Original Equipment Manufacturers to mount on their own wall plates. Rotary and push dimmer modules Our range includes dimmer modules with rotary or push mechanical es, and to suit resistive s. Also suitable for dimmable electronic transformer s or inductive transformer s. o need to derate for mains halogen lamps (follow the resistive wattages in the tables below). Rotary dimmer modules for resistive s Order code Min. and Max. wattage - resistive s Min. and Max. wattage - transformer s Dimensions (mm) DRD 250W 40 250W ot suitable 64x25x21 DRD 400W 60 400W ot suitable 64x25x21 Push dimmer modules for resistive s For wiring diagrams see page 47 (diagrams 47a -47h). Order code Min. and Max. wattage - resistive s Min. and Max. wattage - transformer s Dimensions (mm) DPD 250W 40 250W ot suitable 64x25x21 DPD 400W 60 400W ot suitable 64x25x21 DPD 630W 60 630W ot suitable 64x44x42 DPD 1000W 100 1000W ot suitable 104x50x24 Push dimmer modules for dimmable wire-wound transformer low voltage s For wiring diagrams see page 47 (diagrams 47a -47h). Order code Min. and Max. wattage - resistive s Min. and Max. wattage - transformer s Max. no. of transformers Dimensions (mm) DPD 250WI 60 400W 60 250W 6 64x25x21 DPD 400WI 60 630W 60 400W 8 64x44x42 DPD 630WI 60 1000W 60 630W 12 104x50x24 Push dimmer modules for dimmable electronic transformer low voltage s For wiring diagrams see page 47 (diagrams 47a -47h). Order code Min. and Max. wattage - resistive s Min. and Max. wattage - transformer s Max. no. of transformers Dimensions (mm) DPD 250WIET 40 250W 40 250W 4 64x25x21 DPD 400WIET 60 400W 60 400W 6 64x25x21 DPD 630WIET 60 630W 60 630W 8 64x44x42 DPD 1000WIET 60 1000W 60 1000W 12 104x50x24 70

O.E.M. PRODUCTS Rotary and push dimmer modules Push module, 1 or 2 way ing. Any type of. (o dimming.) For wiring diagrams see page 47 (diagrams 47a -47h). Order code Maximum resistive Maximum transformer Dimensions (mm) DPS 1500W 6 amps 6 amps 64x25x21 Rotary intermediate module. Any type of. (o dimming.) For wiring diagrams see pages 47 (diagrams 47e -47h). Order code Maximum resistive Maximum transformer Dimensions (mm) DRS 1000WIT 4 amps 4 amps 64x25x29 Time lag modules These modules have adjustable time lags. They require 3 wire connections: live, neutral and ed line. Based on 3-wire plated time lag es shown on page 36 (TSW A20 and TSW A120). For wiring diagrams see page 37 (diagrams 37a - 37b, 37d - 37e). (Can be wired in parallel, however cannot be operated by slave es.) oading: Up to 6 amps (1500W) of resistive, fluorescent or inductive lighting s, or up to 1 amp (250W) of fans. Order code Time lag range Dimensions (mm) T A20 2 20 minutes 64x25x31 T A120 12 120 minutes 64x25x31 Products opposite and above measuring 64x25x21mm (various push and rotary dimmer modules and push module) 25 21 Products opposite measuring 64x44x42mm (various push dimmer modules) 44 42 Products opposite measuring 104x50x24mm (various push dimmer modules) 50 24 64 64 104 Spindle Ø = 6mm Spindle Ø = 6mm Spindle Ø = 6mm DRS 1000WIT 64x25x29mm (rotary intermediate module) T A20, T A120 25 29 25 21 64 64 Spindle Ø = 6mm Spindle Ø = 6mm 31 71

DAERS imited DAERS Business Centre Vincients Road, CHIPPEHAM Wiltshire, S14 6Q United Kingdom Tel:+44 (0)1249 443377 Fax:+44 (0)1249 443388 E-mail: sales@danlers.co.uk www.danlers.co.uk ISO 9001: 2008 Registration o. 879 ISO 14001: 2004 Registration o. 879 Company Registered umber 2570169 VAT Registration umber 543 5491 38 January 2012