Date: Project #: Engineer: Prepared By: Bid Date:

Similar documents
Boiler & Water Heater

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Project Name: Location: Engineer: Contractor: I. GENERAL

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

TABLE OF CONTENTS BRADFORD WHITE BOILERS

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Raptor 320HB & 399HB Submittal Sheet

Utica Boilers MAC Submittal

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

AFUE 95% Heating Input 50,000 to 200,000 Btuh

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

MASCOT II. Gas-Fired Wall-Mounted Combination Boiler & Water Heater

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Suggested Specifications Prestige Excellence 110

Brute Elite Hydronic Boilers Indoor 285, ,000 BTU/Hr. 95+% Thermal Efficiency

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Brute Elite Volume Water Heaters Indoor 150, ,000 BTU/Hr. Up to 97% Thermal Efficiency

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

Addendum H to Brute LX 1295A Document 1372

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Advanced Heating and Hot Water Systems

Automatic Circulating Water Heaters

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Up to 98% Thermal Efficiency CONDENSING COMMERCIAL GAS WATER HEATERS CONTROL WITH CASCADING SEQUENCER UP TO 98% THERMAL EFFICIENCY

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Commercial Gas Water Heaters

Engineer: Project Name: Project Location: Contractor:

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

Residential/Commercial Gas Condensing Tankless Models

New Features RIELLO ARRAY. v2.0. High Efficiency Condensing Boiler MBH.

HIGH EFFICIENCY COMMERCIAL BOILERS

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

The EnduroTi HIGH MASS. Superior Construction: COMMERCIAL CONDENSING BOILER. Stainless Steel Titanium Blend. 10 : 1 Turndown Ratio

Commercial Gas Water Heaters

MECHANICAL VENTING VERSATILITY

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

Heating Systems Company LAARS INTRODUCES. The MASCOT LX. A Boiler. An All-in-One Answer to Your Home Heating and Hot Water Needs

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

Tankless Condensing High Efficiency Water Heaters

iq251, Gen II Submittal Data

C1050ES Tankless Water Heater

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

C1210ES Tankless Water Heater

Revitalize Building Mechanical Systems (4619)

Residential Gas Tankless Water Heater

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

HIGH EFFICIENCY RESIDENTIAL BOILERS FIRE TUBE A PERFECT BOILER FOR EVERY NEED

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Commercial Tankless Rack System

iq1001, Gen II Submittal Data

Engineer: Project Name: Project Location: Contractor:

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

Commercial Tankless Rack System

DIVISION FINNED WATER-TUBE BOILERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

CONDENSING HIGH EFFICIENCY BOILERS

FXLF-9. High Efficiency Water Heaters and Boilers

Commercial Gas Water Heaters

i200, Gen II i250, Gen II Submittal Data

Commercial. Phoenix. Advanced Heating & Hot Water Systems. 96% Efficient Commercial Water Heater

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

GB Condensing Gas Boiler

Commercial Tankless Rack System

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

GB Condensing Gas Boiler

DIVISION FINNED WATER-TUBE BOILERS

HIGH EFFICIENCY CONDENSING GAS COMBINATION BOILERS FIRE TUBE COMFORT DONE RIGHT. 95% AFUE Efficiency. f ive. nt y. pa rts w a

Tankless Water Heaters

Commercial. Phoenix. up to 96% Efficient Commercial Water Heater. Advanced Heating & Hot Water Systems

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Get The Edge Over The Competition with The Summit

Commercial Tankless Rack System

Boiler Product Line Brochure

Transcription:

Brute NEOTHERM Date: Project #: Hydronic Boiler Hydronic Boiler Indoor Sizes 285-850 Submittal Data Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment Electronic PID modulating control with large color touchscreen display Password-protected parameters for installer use Test feature allows forced min or max firing Complete diagnostics for analog and digital inputs Displays holds, alerts and errors in clear text form Dray alarm contacts for ignition failure High condensing efficiency Modulation down to 20% of full fire (5:1 turndown) Sealed combustion chamber Pre-mix stainless steel burner Low NOx system exceeds the most stringent regulations for air quality - 10 ppm NOx Horizontal or vertical direct vent Horizontal vent and air terminals Vent and air pipe lengths of up to 100 equivalent feet (each) Built-in condensate trap Vent temperature cutoff feature Direct spark ignition system Indirect water heater priority Cascades with other NeoTherms Brutes. Sensor for indirect domestic water tank 160 psi maximum working pressure Stainless steel heat exchanger with welded construction (no gaskets) ASME "H" stamp 75 psi (517 kpa) ASME rated pressure relief valve Water flow switch (399-850 only) Temperature & pressure gauge Drain valve Multiple pump control for boiler pump, system pump and indirect domestic water pump, each with delay Optional pump (sized to model) available for field installation (285-500 only) Integrated PID temperature and ignition controls Large user-interface and display Alarm output Accepts external 4-20mA (0-10V with optional convertor) modulation signal Outdoor reset with customizable reset curves, domestic hot water override and warm weather shutdown Outdoor air temperature sensor On/off toggle switch Manual reset high limit Burner site glass Zero clearance to combustible surfaces 10-year limited warranty Boiler Data Number of Units: Fuel Natural Propane Pump Options Pump included (285-500 only) No pump Factory Mounted Options CSD-1 (covers FM & GAP) (500-850) Low water cutoff (500-850) High & Low gas pressure switches (500-850) Additional auto reset high limit 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve 75 psi pressure relief valve (std) 125 psi pressure relief valve 150 psi pressure relief valve Bell for ignition failure 2016 model 285

Accessories for Field Mounting Water flow switch (285 only) Low water cutoff 0-10V convertor for modulation control High & Low gas pressure switches Boiler pump (285-500) Concentric vent terminal, 3" Flush-mount terminal, 3" Flush-mount terminal, 4" Propane conversion kit Condensate neutralizer kit Vari-Prime Variable Speed variable Pump speed Control pump drive BACnet gateway LON gateway Sizing Data Input Output AFUE Thermal Comb. Gas Water Shipping Model Efficiency Efficiency Conn. Size Conn. Size Weight BTU/h kw BTU/h kw % % inches inches Lbs kg 285 285,000 83.5 264,000 77.4 95.0 N/A N/A ¾ NPT 1¼ NPT 299 136 399 399,900 117.2 386,000 113.1 N/A 96.5 96.5 ¾ NPT 1¼ NPT 364 165 500 500,000 146.4 475,000 139.2 N/A 95.0 95.0 1 NPT 1½ NPT 419 190 600 600,000 175.7 572,000 167.6 N/A 95.3 96.0 1 NPT 1½ NPT 426 193 750 750,000 219.8 724,000 212.1 N/A 96.6 96.6 1½ NPT 2 NPT 481 218 850 850,000 248.9 813,000 238.2 N/A 95.7 95.7 1½ NPT 2 NPT 503 228 NOTES: For other boiler ratings: Boiler Horsepower: HP = Output Radiation Surface: EDR sq. ft. = Output 33,475 150 Clearances Suggested Service Appliance Access Clearance Surface inches cm Left Side 1 2.5 Right Side 12 31 Top 24 61 Back 6 15 Closet, Front 6 15 Alcove, Front 24 61 Vent Certified by CSA for zero clearance to combustible materials on all sides. Electrical Data Sizes Boiler Pump Connections Ratings Volts Phase Amps (System Pump and DHW Pump Connections) 285 850 120 Single 2* 115V Maximum 1HP No Pump or 7.4A max 285 500 Less With Pump 120 Single than 115V Maximum 1HP 6* or 7.4A max * Minimum 15A circuit required

Vent System Intake Exhaust Maximum (Air) (Vent) Allowable Size Pipe Pipe Equivalent Length* 285 3" 3" 20 ft 6 m 4" 4" 100 ft 30 m 399 4" 4" 100 ft 30 m 500 4" 4" 100 ft 30 m 600 750 850 4" 4" 40 ft 12 m **6"** **6"** 100 ft ** 30 m ** 4" 4" 40 ft 12 m 6" 6" 100 ft 30 m 4" 4" 40 ft 12 m 6" 6" 100 ft 30 m Installations in the U.S. require exhaust vent pipe that is a combination of PVC & CPVC complying with ANSI/ASTM D1785 F441, polypropylene pipe that complies with ULC S636, or stainless steel complying with UL1738. Installations in Canada require exhaust vent pipe that is certified to ULC S636. Intake (air) pipe may be ABS, PVC, CPVC or galvanized material. Installer must comply fully with manufacturer's installation instructions, including use of minimum exhaust length CPVC, to maintain ANSI Z21.13 safety certification. Closet and alcove installations do not allow the use of PVC under any circumstances * To calculate max equivalent length, measure the linear feet of the pipe, and add 5 feet (1.5m) for each elbow used. ** Allowed only if the vent pipe is no more than 20 equivalent feet longer than the air pipe. Water Flow Requirements Temperature Rise in F 20 F 25 F 30 F 35 F 40 F Flow H/L Flow H/L Flow H/L Flow H/L Flow H/L Size gpm feet gpm feet gpm feet gpm feet gpm feet 285 27 25.5 22 17.5 18 14 15 10.5 13 8 399 38 28 31 20 25 14.5 22 11 19 9 500 48 24 38 16 32 12 27 9 24 8 600 58 44 46 31 38 22 33 18 29 15 750 72 37 58 23 48 17 41 13 36 10 850 81 33 65 22 54 15 46 10 41 8 Temperature Rise in C 11 C 14 C 17 C 19 C 22 C Flow H/L Flow H/L Flow H/L Flow H/L Flow H/L Size lpm m lpm m lpm m lpm m lpm m 285 102 7.8 81 5.3 68 4.3 58 3.2 51 2.4 399 144 8.5 116 6.1 96 4.4 83 3.4 72 2.7 500 180 7.3 144 4.9 120 3.7 103 2.7 90 2.4 600 218 13.4 174 9.4 145 6.7 125 5.5 109 4.6 750 274 11.3 219 7.0 182 5.2 156 4.0 137 3.0 850 307 10.1 246 6.7 205 4.6 175 3.0 154 2.4

Dimensional Data, Sizes 285-500 Brute is shipped with adapters for the air and vent that accept standard pipe of the proper size and type. Dimensions shown in inches cm. Ø AIR A B D E F G J K L INLET* Ø VENT* Size in in in in in in in in in in in 285 26¾ 7¼ 6¼ 11 17 14 9¾ 13¼ 20¼ 4 4 399 31½ 5¼ 4¼ 14½ 21½ 19¼ 8¼ 18½ 25 4 4 500 37¾ 5¼ 4¼ 15 26 20½ 5¾ 20 27¼ 4 4 cm cm cm cm cm cm cm cm cm cm cm 285 68 18 15 28 43 36 25 34 51 11 11 399 80 13 11 37 55 49 21 47 64 11 11 500 96 13 11 38 66 52 15 51 69 11 11 Dimensions are nominal.

Dimensional Data, Sizes 600-850 Brute is shipped with adapters for the air and vent that accept standard pipe of the proper size and type. Dimensions shown in inches cm. RIGHT SIDE AIR A B D E F G J K L Ø INLET* Ø VENT* Size in in in in in in in in in in in 600 37¾ 5 4¼ 15 20 3 5¾ 26 29¾ 4 4 750 51 6 5¼ 19 40½ 3¼ 5¾ 30½ 35½ 4 6½ 850 55¼ 6 5¼ 19 44½ 3½ 5¾ 35 39¾ 4 6 cm cm cm cm cm cm cm cm cm cc cm 600 96 13 11 38 51 8 15 66 76 11 11 750 130 13 13 48 103 8 15 77 90 11 17 850 140 13 13 48 113 9 15 89 101 11 17 Dimensions are nominal.

200 Lafayette St. Middleville, MI 49333 Warranty: (800) 531-2111 www.bradfordwhite.com Litho in U.S.A. Bradford White 1608 Document 1217R-BW