R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas

Similar documents
ELECTRIC BOILERS. RANGE 1kW to 980kW ABOUT ATLANTIC ELECTRIC DOMESTIC HOT WATER HEATERS. WATER HEATERS 445 to 7520ltrs/hr

MULTI ELEC. Electric Boilers TECHNICAL MANUAL

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0)

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

heat interface units A BOILER WITHOUT A FLAME

Sirius FS. Working towards a cleaner future

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Multi-Elec COMPACTE BOILER

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

The iqe Boiler Range. Combination and System T Boilers.

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

FCX FUEL OIL CONDENSING BOILER RANGE

EFG ENERGY OPTIMISING SYSTEMS

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Series 1000 & Storage Water Heaters

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Sirius WH. Working towards a cleaner future

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

WATER-TUBE POOL HEATERS

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

WHE 2.24 / WHE 2.24 FF

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Link-Up. Solid Fuel Association Guide to Central Heating.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

WATER-TUBE POOL HEATERS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Amptec. Electric flow boiler

Power X High Power Condensing Wall-Hung Boilers

Assessment Schedule - TS.6

Copper-Fin GAS-FIRED WATER HEATERS

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

thermocompact High performance system boiler range

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

MULTIPLEX SELF RECUPERATIVE gas burner

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

CP+ Gas & Oil Cabinet Heater Range

LBF RANGE BALANCED FLUED WATER HEATERS

Power X High Power Condensing Wall-Hung Boilers

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

CAST IRON ATMOSPHERIC BOILERS

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

S-AF Floor Standing Condensing Boiler kW

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

Solar heating systems

DIVISION FINNED WATER-TUBE BOILERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

The Ultimate Solution for Electric Central Heating. Fusion. Comet

INDEPENDENT COMBINATION & SYSTEM BOILERS.

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE:

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

GRANT. Euroflame Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

GFT-060/40/H2. Designed and built According AD-2000 regulation Homologation and branded CE According to the European Directive CE

Heating & cooling Australia since 1965

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

1 VICTRIX ZEUS Superior kw I features

Cast Iron Boilers. G Series ( kW)

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data

Hamworthy. Melbury HE. High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners. Outputs 530kW to 10000kW

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

GIALIX. An adjustable power to match your needs for more economies! Wall-mounted electric boiler 2 to 196 kw. F RENCH Manufacturer.

the electric heating company ELECTRIC BOILER HANDBOOK

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

The Greenstar CDi gas-fired condensing combi boiler series. Technical and specification information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

ecotec plus New high efficiency condensing combination and system boiler ranges

GRANT VORTEX Condensing Oil Boiler range

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

GB24 & GB30. User Manual

STREBEL S-CB + Cascade Kits

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW.

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Transcription:

DATA SHEET: TDS101.4F 10-625kW R-SERIES YEAR ROUND MAXIMUM CONDENSING BOILER burning diesel oil, kerosene, natural gas or liquid petroleum gas 92% to 99.5% GCV efficiencies throughout the year Modulating, High/Low and On/Off Burners Pre-mix burners on Natural Gas with NOx < 30mg/kWHr Balanced or conventional flues up to 50 metres or more Built-in shunt pump and header 3 BARS standard maximum working pressure 4, 5, 6 or 7 BARS (available to order) 95 C maximum working temperature 90% and above A A 86% - 90% B 82% - 86% C 78% - 82% D 74% - 78% E 70% - 74% F Below 70% G Demountable for access through most openings Easy maintenance of boiler, burner and controls

ABOUT THE ATLANTIC R-SERIES BOILER The ATLANTIC R-Series year-round maximum condensing boiler has two distinct heat exchangers, the first of developed quality steel design and the second of high grade plastic design. The flue gases leave the first heat exchanger at temperatures below 90 C, and are then extracted from the second condensing heat exchanger at temperatures always below 50 C. The introduction of combustion air through the condensing exchanger lowers the flue gas temperature below dew-point, hence there is no need for return water temperature to be low. BURNER MAIN HEAT EXCHANGER HEATING FLOW & RETURN FRESH AIR The boiler will condense to it's maximum efficiency even at 82 C flow & 71 C return. For combustion air, at inlet temperatures below 30 C, efficiencies always exceed 92%. These conditions apply throughout the year in the UK. CONDENSING EXCHANGER FLUE GASES TREATED CONDENSATE The lower part of the condensing exchanger has a condensate neutralising section built in, eliminating the need for separate equipment in the future. The ATLANTIC R Series boiler pipework requirements are as straight forward as a conventional boiler or a high efficiency boiler. No special circuits are required to create condensing. Cross section of main heat exchanger Front view of main heat exchanger (purple) and of condensing exchanger frame (yellow) IN-BUILT FEATURES Constant temperature requirements are achieved with boiler controller, shunt pump, 4-port valve and flow sensor. Minimum flow and minimum temperature requirements are achieved with boiler controller, pump, 4-port valve and sensor. Variable temperature requirements are achieved with boiler controller, shunt pump, 4-port valve, outside sensor and flow sensor. All the above systems can be provided by the boiler system. Alternatively, the ATLANTIC R Series boiler(s) can be enabled by a BMS system and also can provide alarm signals to a BMS system. The boiler(s) will continue their own in-house operational control ensuring correct combustion and hydraulic function. As a modulating burner option, the boiler controller system can be modified on a 0-5 volt and 0-10 volt band to give variable heat output.

PERFORMANCE, DIMENSIONS & CONNECTIONS PERFORMANCE DIMENSIONS CONNECTIONS Model 17 22 40 60 90 150 200 300 400 500 600 Maximum Output kw 17 22 40 60 90 150 210 315 370 485 625 Standard Minimum Output kw 10 15 12 20 33 40 42 80 80 80 150 Full load efficiency Ambient air 22ºC Oil % gcv 93.5 95.0 95.3 94.7 93.2 96.6 94.0 95.3 92.5 94.5 94.4 Gas % gcv 90.6 92.2 92.9 91.9 90.4 93.7 91.2 92.4 89.7 91.7 91.6 Fuel used Oil ltrs/hr 1.7 2.2 4.0 7.2 9.1 14.9 26.0 31.0 45.7 52.6 69.5 Gas m³/hr 1.7 2.0 4.0 6.0 9.6 15.0 19.8 30.0 46.3 53.1 63.5 Exit Flue gases@30ºc Oil m³/hr 23 30 55 82 124 206 274 411 547 684 893 Gas m³/hr 25 34 61 92 138 230 306 460 613 767 920 Dry weight kg 125 200 300 438 794 996 1014 1790 1975 2100 2225 Water contents ltrs 36 36 75 80 197 330 500 910 1010 1110 1475 Min water pressure BARS 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Standard water pressure BARS 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 Max (on order) BARS 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 Model 17 22 40 60 90 150 200 300 400 500 600 Height mm 1165 1365 1510 1645 1740 1945 1985 2070 2220 2220 2550 Width mm 350 445 545 550 740 885 1225 1225 1425 1425 1425 Depth mm 940 1000 1220 1330 1750 2030 3140 3770 3770 3770 3770 Height-demountable mm 600 750 895 985 965 1070 1281 1370 1400 1400 1510 Width-demountable mm 410 445 545 550 740 885 1225 1225 1225 1225 1225 Depth-demountable mm 645 680 760 784 1130 1255 1340 1970 1970 1970 1970 Access front mm 500 500 500 700 1000 1000 1000 1000 1000 1000 100 Access one side mm 100 100 100 100 100 100 100 100 100 100 100 Access other side mm 500 500 500 500 500 500 500 500 500 500 500 Access rear mm 300 300 300 300 300 300 300 300 300 300 300 Access top mm 300 300 300 300 300 300 500 500 500 500 500 Model 17 22 40 60 90 150 200 300 400 500 600 Fresh air inlet mm 75 75 75 75 110 110 125 125 150 150 200 Warm air burner inlet mm 50 50 50 70 100 100 125 125 150 150 200 Fresh gas outlet mm 75 75 75 75 110 125 200 200 200 200 200 Heating flow mm 25 25 25 25 40 50 65 65 80 80 100 Heating return mm 25 25 25 25 40 50 65 65 80 80 100 Hot water primaries mm 25 25 25 25 32 40 50 50 50 50 50 Condensate mm 50 50 50 50 50 50 50 50 50 50 50 SPECIFICATION The boiler body is made of 3mm thick quality steel with a water-cooled combustion chamber. The burner fires horizontally through the combustion chamber and makes a series of passes through a horizontal heat exchanger. The steel boiler is externally covered with an 80mm layer of rock wool thermal insulation. Access to the heat exchanger is through a panel at the front of the boiler secured by four bolts. The condensing exchanger is made of polypropylene and contains a series of smooth polypropylene heat exchanger tubes. The bottom of the condensing exchanger has a section containing limestone granules to neutralise the condensate. The boiler has a pre-wired control panel incorporating an isolator switch with indicator lamps, modulating, high/low or on/off burner control, water flow sensor with indicator lamps, a safety limit thermostat, hours run indicator, flue gas thermometer and a weather-controlled programme. The boiler assembly includes a 4 way valve, a shunt pump, both pre-wired and operated by the control panel, and a shunt pipe arrangement with connections for a restricted constant temperature circuit. The pressurised B100 or gas burner has; aluminium body, motorised fan air supply, oil or gas valve with controlled rate of opening, ignition transformer, air/b100 or air/gas mixing, combustion head, differential pressure switch, control box with ionisation flame protection, balanced flue pressure switch controls. Burners are available with pre-mix, modulating, high/low and on/off operation depending on fuel type and model size. The flue gas fan(s) in each boiler assembly contain - aerodynamic polypropylene housing, vibration free mountings, minimum pressure loss inlet & outlet, totally enclosed synchronous motor, maintenance free, dust & water proof bearings, infinitely adjustable fan motor speed regulator. The number of fans depends on the boiler model. From the model R22-15 to the model R22-90 the fan is mounted within the boiler casing. From model R22-150 upwards, the multi-fan assembly is mounted to the rear of the boiler.

TYPICAL VIEWS OF THE R-22-200.NG.M PRE-MIX NATURAL GAS MODULATING R22 SERIES BOILER ABOVE: Front view of boiler showing modulating pre-mix burner and pre-warmed combustion air tube serving the burner ABOVE: Rear view of boiler showing add-on flue gas fan assembly LEFT: Side view of boiler with engineer checking burner settings RIGHT: Rear view of boiler showing shunt pump and 4-way valve assembly together with safety control panels and safety relief valve APPLICATIONS Airport terminals Ambulance and Fire Stations Art Galleries and Museums Banks and Shops Boarding Schools Business Centres Children s/nursing Homes Churches and Cathedrals Colleges and Universities Country Houses Day Nurseries Department Stores Factories Greenhouses and Botanical Gardens Halls of Residence Hospitals Hotels and Motels Housing Developments Leisure Centres Libraries Listed Buildings Motorway Services Office Buildings Police Stations Postal Sorting Offices Prisons Residential Hostels Residential Nursing Homes Shopping Malls Sports Clubs Swimming Pools Theatres Warehouses

ISOMETRIC DRAWING 4 way valve, variable temperature circuit Main heat exchanger Temperature circuit, flow and return Boiler shunt pump Condensing exchanger Fan assembly Factory Quarter Development, Acton 2 - R22-500kW dual-fuel B100 biodiesel and natural gas condensing boilers leading 4 - NA-R 930kW natural gas high efficiency boilers Clarence House, St James Palace 2 - R22-150kW natural gas condensing boilers with facility to switch to B100 bio-diesel St Andrews Hospital, Northampton 3 - R22-500kW digital modulating natural gas condensing boilers High Peak Housing, Derbyshire 2 - R22-150kW natural gas condensing boilers Glencanisp Lodge, Scotland 1 - R22-90kW kerosene condensing boiler

PIPEWORK ARRANGEMENTS Each boiler has its own header with in-built 4-port valve and shunt pump. This guarantees minimum water flow and temperature control. Single and group boilers can use a balancing & sedimentation vessel or a low velocity header as a neutral heat outlet. Any number of circuits, in order of priority, can then be served adequately from the boiler(s) TYPICAL ONE BOILER ARRANGEMENT One R22 boiler serves domestic hot water (priority) and weather compensated radiators. The fast-response indirect cylinder always needs to receive primary hot water within 1 or 2 minutes of demand so it receives priority from the balancing vessel or header. The radiators have a response time of about 20 minutes so they take primary heat as a second function. Consequently the indirect cylinder is served first from the balancing vessel. BALANCING VESSEL Domestic Hot Water Priority Weather compensated space heating ACFE Auto top up unit and fast fill bypass kit DHW MULTIPLE BOILER ARRANGEMENT This might be a typical medical centre situation where duty and standby boiler plant serves sanitary hot water, air conditioning and underfloor space heating. The ultra-fast response plate heat exchangers need primary heating within a few seconds, the air conditioning (in mid-winter) needs primary heating within a few minutes, whereas the underfloor space heating has a much longer response time. The plate heat exchangers are served first from the balancing vessel, the air conditioning second and the under-floor heating last. PHE DHW PHE Duplex Domestic Hot Water Priority BALANCING VESSEL Constant Temperature Variable Temperature Weather Compensated Space Heating ACFE Auto top up unit and fast fill bypass kit

CONDENSING FLUE ARRANGEMENT The ATLANTIC R Series boilers can have either conventional or balanced flues for diesel oil, kerosene, natural gas or LPG. The boiler flue requirements are economic often cutting the costs of material and labour when compared to other boilers. As the flue gas exit temperature is always low, the volume of gases is always greatly reduced throughout the year. Flexible tube Jubilee tube Socket Viton Seal Drain FLEXIBLE CONNECTOR Boiler 135 connector 90 connector Boiler straight connector Drain connector Use of brick chimney stack to form vertical balanced flue Single boiler balanced flue for flat or pitched roof Flue gases Flue gas effluent Fresh air 360 inlet Fresh air FLAT OR PITCHED ROOF Warmed air inlet to boiler Chilham Castle, Kent Flue gases from boiler In addition, the ATLANTIC R Series boilers have variable speed flue gas extract fans which permit extensive vertical and horizontal flue ducts in carefully chosen TECHNAFLON condensing flues. The flues are graded to the boiler(s) to allow the condensate to drain to the tank in the base of each boiler. The condensate is then treated using limestone marbles before flowing out to a normal drain. TECHNAFLON condensing flues are precision-made from polyvinylidene fluoride (PVDF) which is extremely corrosion-resistant, hard wearing and not effected by ultra-violet radiation. The flues are installed without insulation. The flue gases cool rapidly, releasing the heat to the building and increasing the plant efficiency.

BALANCING AND SEDIMENTATION VESSEL The balancing vessel is located close to the boilers, with its feet placed on a base to allow the boiler flows and returns to normally vent to the vessel. One full size cold feed pipe should be taken to the connection P on the vessel and fitted with a normally open ball valve, allowing unrestricted heating system expansion and contraction to take place along the pipe. The different flow pipes of separate heating circuits should be connected progressively down the header from the top flow 'A'. The returns should be connected similarly upwards from the bottom return 'I'. DHW priority flow and return circuits should be taken from and to the high level W tappings. When connections are complete and the system is ready for filling. Firstly everything should be isolated from the vessel. This includes the boilers (with their shunt pumps) connected to L (flow) and M (return) and the heating circuits - 'A' and 'I'. - which should be isolated from the vessel. The vessel air vent V and drain/sludge valve D should be closed. The different heating circuits should then be filled separately. As the circuits are progressively filled, they should be regularly sludged through the bottom of the vessel by opening the circuit valves and the drain and sludge valve until the BSV AND SV STANDARD DIMENSIONS Capacity Diameter 116kW 100mm 348 kw 150mm 696 kw 200mm 1740 kw 300mm 2900 kw 500mm water clears. This should be repeated for all the circuits. After filling all the circuits, the circuit pumps should be set running to check for further sedimentation arriving in the vessel. When this is clear, the boiler valves may be slowly opened and then the shunt pumps set running. BSV116 L M Balancing and Sedimentation Vessel P V W W D A I ABOUT ATLANTIC ATLANTIC BOILERS was formed in 1980 to promote highly efficient boilerplant and within two years had supplied the first commercial gas condensing boilers in the United Kingdom. For 30 years, ATLANTIC BOILERS has supplied both gas and oil condensing boilers to many Universities, Hotels, Hospitals, Medical and Social Care Buildings, Leisure Centres, Schools, Offices and Housing Developments plus many other types of buildings. ATLANTIC BOILERS also supplies condensing and highly efficient domestic hot water generation, based on stainless steel manufacture. Coupled with the supply, ATLANTIC BOILERS provides back-up commissioning, spares and servicing by way of a network of merchants throughout the United Kingdom. ATLANTIC BOILERS HIGH EFFICIENCY CONDENSING BOILER-PLANT ADDRESS: ATLANTIC BOILERS, PO BOX 11, ASHTON UNDER LYNE, OL6 7TR WEB: WWW.ATLANTICBOILERS.COM EMAIL: INFO@ATLANTICBOILERS.COM TEL: 0161 621 5960 FAX: 0161 621 5966 ATLANTIC 2000 - boilerplant sales ACM ATLANTIC - commissioning and maintenance ATLANTIC 4422 - spares