MULTI-PLEX FOR IBC SL 40-399 BOILER Engineered Easy to Install Turnkey System Better Boilers Lord Tweedsmuir School, BC
QUOTATIONS For a project quotation please contact your local IBC representative or email info@ibcboiler.com and we can put you in contact with a distributor in your area.
MULTI-PLEX R A C K I N G Engineered Easy to Install Turnkey System A Modular freestanding system for commercial and multi family installation the Multiplex racking system components fit through standard doorways reducing the need for heavy transport equipment. Our easy to set up boiler networks also provide for precise load matching through wide turndown ratios. Quick installation 4 x SL 40-399 s x 2 Men = 8 Hrs Compact design. Easy to get into small spaces & around existing equipment Flat pack design - reducing shipping costs Multiple options available Inline, back to back and rack only options available Header sizes include 3:, 4 or 6. Left or right header connections includes 1 set of blind flanges. Combinations from 2 to 12 boilers on a single racking system. Outdoor Sensor (to master boiler) Superior Quality Low head loss - better flow rates Flanged headers for easy expansion Seismic ratable System Includes SS Flex Connectors Isolation Ball Valves Check Valve UPS 43-44F Pump Boiler Drains Unions Welded Steel Supply & Return Headers Connection Points for Optional Accessories All necessary Nipples & Fittings Assembly Instructions Secondary Loop Sensor (to master boiler) 6 Boiler Network: Multi-boiler installation with 3 Indirect DHW tanks on priority opt-out with 2 space-heating loads. Load Combined for simultaneous operation and optimum combustion efficiency temperatures.
Multiplex Option In line Side View 3 Boiler in line Back to back Side view 90-168 = 4, 3 + 3 Back to Back System Rack Only Option This freestanding option is meant for the installation that requires custom boiler piping or on-site fabrication of the boiler piping. R-137 : 1 boiler rack only SPECIFICATIONS Multiplex Racking System Part No A "/ mm Height " / mm B "/ mm IN LINE RACK 3" Header 2 Boiler In-line 90-151 70" / 1778 mm 76.25" / 1937 mm 35.5" / 902 mm 3 Boiler In-line 90-149 102" / 2590 mm 76.25" / 1937 mm 35.5" / 902 mm 4" Header 2 Boiler In-line 90-159 70" / 1778 mm 76.25" / 1937 mm 35.75" / 908 mm 3 Boiler In-line 90-160 102" / 2590 mm 76.25" / 1937 mm 35.75" / 908 mm 4 Boiler In-Line 90-161 134" / 3404 mm 76.25" / 1937 mm 35.75" / 908 mm 5 Boiler In-Line 90-162 166" / 4217 mm 76.25" / 1937 mm 35.75" / 908 mm 6 Boiler In-Line 90-163 198" / 5030 mm 76.25" / 1937 mm 35.75" / 908 mm 6" Header 4 Boiler In-line 90-171 134" / 3404 mm 76.25" / 1937 mm 38" / 965 mm 5 Boiler In-line 90-178 166 / 4217 mm 76.25 / 1937 mm 38 / 965 mm 6 Boiler In-line 90-164 198" / 5030 mm 76.25" / 1937 mm 38" / 965 mm 8 Boiler In-line 90-165 262" / 6656 mm 76.25" / 1937 mm 38" / 965 mm 10 Boiler In-line 90-166 326" / 8280 mm 76.25" / 1937 mm 38" / 965 mm 12 Boiler In-line 90-176 390" / 9906 mm 76.25" / 1937 mm 38" / 965 mm 4" Header BACK TO BACK RACK 2 + 2 Boiler Back to Back 90-167 70" / 1778 mm 76.25" / 1937 mm 58.5" / 1486 mm 3 + 3 Boiler Back to Back 90-168 102" / 2590 mm 76.25" / 1937 mm 58.5" / 1486 mm 6" Header 3 + 3 Boiler Back to Back 90-169 102" / 2590 mm 76.25" / 1937 mm 60.5 / 1537 mm 4 + 4 Boiler Back to Back 90-170 134" / 3404 mm 76.25" / 1937 mm 60.5 / 1537 mm 5 + 5 Boiler Back to Back 90-172 166" / 4217 mm 76.25" / 1937 mm 60.5 / 1537 mm 6 + 6 Boiler Back to Back 90-177 198 / 5030 mm 76.25 / 1937 mm 60.5 / 1537 mm R-139: 4 boiler rack only RACK ONLY (No piping) Racking Only Part No. A " / mm Height " / mm Depth / mm 1 Boiler Rack R-137 38" / 965 mm 76.25" / 1937mm 26.5" / 673 mm 2 Boiler Rack R-138 70" / 1778 mm 76.25" / 1937mm 26.5" / 673 mm 3 Boiler Rack R-136 102" / 2590 mm 76.25" / 1937mm 26.5" / 673 mm 4 Boiler Rack R-139 134" / 3404mm 76.25" / 1937mm 26.5" / 673 mm 5 Boiler Rack R-140 166" / 4217 mm 76.25" / 1937mm 26.5" / 673 mm 6 Boiler Rack R-134 198" / 5030 mm 76.25" / 1937mm 26.5" / 673 mm 7 Boiler Rack R-141 230" / 5843 mm 76.25" / 1937mm 26.5" / 673 mm 8 Boiler Rack R-142 262" / 6656 mm 76.25" / 1937mm 26.5" / 673 mm Secondary Loop Sensor (to master boiler) DHW Sensor well - typical of 3, to respective opt-out boilers Fill station with isolation valve closed or. fill tank
More Features Built-in Menu SL 40-399G3 Express Setup Load Status User Setup Installer Setup Diagnostics Back IBC 5:59 SL 40-399G3 40,000 to 399,000 BTU/H Commercial / Large Residential Condensing Boiler New Touch Screen V-10 Boiler Control Express set up, Remote monitoring & diagnostics, Easy USB programmability, Optional true native BACnet, Intuitive alert system. Multi-boiler communication up to 9.5 million Btu/h (24 boilers) without additional controls. PVC/CPVC/PPs approved - venting up to 400 feet. Built-in CSA/UL approved LWCO and manual reset high limit. With 24 boilers turndown ratio is 240:1 = min. firing rate range is 40,000 Btu/h all the way up to 9.5 million Btu/h in 1000 Btu/h increments. Built-in multiple zone pump control - up to 4 zones replacing the need for external pump controls. Built-in outdoor reset control of water temperature. Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler. New and innovative side bolt heat exchanger lid configuration. DDC Control 0-10 VDC or 4-20 ma without additional controls. Optional 316 Ti titanium heat exchanger. DHW opt out priority for multi boiler systems. Reverse flow detection. A secure method of remotely managing your SL Boiler from any location. H
Optional Accessories Available Description Part No Description Part No Secondary Loop Sensor 240-033 63M MM Float Style LWCO 180-059 Stainless Steel Well 180-058 TC4 MM Test and Check 180-053 Ext. Water Hi-Limit Manual Reset 180-054 LWCO Piping Kit - 399 P-196 2 1/2" Tridicator 180-019 BACnet - Activation 700-002 Condensate Neutralizer Tank 180-048 Air Vent Piping Kit P-195B Condensate Neutralizer Refill 180-049 30 PSI Relief Valve 180-005 4" Air Intake Filter P-172 45 PSI Relief Valve 180-076 FS-4 Flow Switch 180-079 60 PSI Relief Valve 180-077 FS-4D Flow Switch 180-079D 75 PSI Relief Valve 180-078 Low Loss Headers Size Part No. Max GPM NON ASME RATED 3" LL Header 180-066 124 GPM 4" LL Header 180-067 247 GPM ASME RATED 3" LL Header (ASME) 180-068 124 GPM 4" LL Header (ASME) 180-069 247 GPM 6" LL Header (ASME) 180-080 484 GPM 180-048 Condensate Neutralization Tank P-172 Air Intake Filter mounted directly onto an SL 40-399 boiler SL 40-399 Technical Information Specifications SL 40-399G3 CSA Input (Natural Gas or Propane *) - MBH 40-399 CSA Input (Natural Gas or Propane *) - KW 11.7-117 CSA Output - MBH 38.4-383 CSA Output - KW 11.2-112 Combustion Efficiency (BTS-2000 Thermal Efficiency) 96% Min gas pressure (NG or Propane) - inch w.c. 4 Max gas pressure (NG or Propane) - inch w.c. 14 Ambient temperature - Low ( F/ C) 32 F / 0 C Ambient temperature - High ( F/ C) 122 F / 50 C Max relative humidity (non-condensing) 90% Min water temperature 34 F / 1 C Max programmable water temperature limit 190 F / 88 C Max water temperature lockout limit 201 F / 94 C Max ΔT - supply / return (electronic fence) 40 F Power use (120Vac/60Hz) - Watts @ full fire - Watts 190 (less pumps) Weight (empty) - lbs/kg 240 / 110 Heating Surface Area - ft² / m² 36.56 / 3.40 Pressure vessel water content USG/Liters 6.66 / 25.20 Max boiler flow rate - USgpm 45 Min boiler flow rate - USgpm 20 Max operating pressure - psig 80 Min water pressure - psig 8 Approved installation altitude - ASL 0-12,000 Maximum equivalent vent length, each side 4 200' (Natural Gas or Propane) Air intake options: either direct vent or indoor supply Exhaust pipe size Sched.40; Rigid PPs 4 200 90 Vent elbow allow 8 equivalent 90 Long sweep elbow allow 5 equivalent 45 Elbow allow 3 equivalent PPs 87-90 Elbows Maximum equivalent length use 8 equivalent 3 SS Sidewall Terminal (SST) allow 65 equivalent 3 CPVC (to adapt to the SST) for each 1 allow 3.2 equivalent Flexible PPs 4 Flexible 160 max, using 1.2 x for equivalent length Surface Distance from combustible surfaces Front 2 24 Rear 0 0 Left side 1 0 (to non-combustibles) Recommended distance for installation and service Right side 1 4 (for electric and gas if required) Top 12 12 (for vent connection) Bottom 12 12 (for condensate trap and piping) Better Boilers IBC Technologies Inc. info@ibcboiler.com www.ibcboiler.com Toll Free: 1-844-HEAT IBC / 1-844-432-8422 British Columbia 8015 North Fraser Way Burnaby, BC V5J 5M8 Tel: 604-877-0277 Fax: 604-877-0295 Ontario Unit 5, 1455 16th Ave., Richmond Hill, ON L4B 4W5 Tel: 905-918-0113 Fax: 604-877-0295 Wisconsin 4507 South Taylor Drive, Sheboygan, WI 53081 Tel: 920-783-8340 Fax: 920-783-8339 New Jersey Unit 1, 1100 Taylors Lane, Cinnaminson, NJ 08077 Tel: 856-887-0544 Fax: 856-735-5584 As part of our continuous product improvement, regulation change or clerical error, IBC reserves the right to change specifications and design without notice. 900-053 R3 Sept 2017