Columbia Boiler Company

Similar documents
Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

CWL-GS Series. Models CWL GS, CWL GS DV, NCWL GS, NCWL GS DV Gas Fired Packaged Boiler. Installation Operation Maintenance Manual

USER'S INFORMATION MANUAL

USER S INFORMATION MANUAL

QHT Manual for: SU-2A Gas Burner

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

USER'S INFORMATION MANUAL

User s Information Manual

USER'S INFORMATION MANUAL

LGB Gas fired boiler

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER'S INFORMATION MANUAL

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

USER S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Bosch 80% AFUE Gas Furnace BGS80 Model

User s Information Manual Models: 45, ,000 Btu/hr

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

CYLINDER NOT INCLUDED

OWNERS MANUAL INSTALLATION, OPERATION, & MAINTENANCE INSTRUCTIONS

USER'S INFORMATION MANUAL

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

Models #CSK-31 #CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

USER'S INFORMATION MANUAL

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

25M01A-100 to 25M01A-199 HSI Single Stage Combination Gas Valve

USER'S INFORMATION MANUAL

Pump or Manifold Pressure. Nozzle or Gas Orifice Size. Air Setting

GAS -FIRED VENTED ROOM HEATERS MODEL 61TV

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

WHAT TO DO IF YOU SMELL GAS

24 VAC SYSTEM CONTROL KIT

Models #CSK-335 #CSK-335-RF. CHASKA - XL Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

Suggested Specifications Prestige Excellence 110

G315/5 Cast Iron Boiler

Cast Iron Commercial Hot Water Or Steam Boiler

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

PROBLEM CAUSE SOLUTION

G315/6 Cast Iron Boiler

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

TO DO IF YOU SMELL GAS

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

Boiler & Water Heater

Service Manual Model 3163

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

SURE HEAT MANUFACTURING

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

ROYAL HEAT 240 / 360 GAS FURNACE INSTRUCTIONS

Gas-Fired Natural Draft Hot Water Boilers INSTALLATION INSTRUCTIONS These instructions must be affixed on or adjacent to the boiler

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

INSTALLATION INSTRUCTIONS # BURNER ASSEMBLY REPLACEMENT

USER S INFORMATION MANUAL

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC INSTANTANEOUS TYPE WATER HEATER FOR USE WITH NATURAL AND LIQUEFIED PETROLEUM GAS MODEL 125FX LP

USER S INFORMATION MANUAL

G515/7 Cast Iron Boiler

24 VAC SYSTEM CONTROL KIT

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

Peerless Boilers. Series MI. Residential Gas Boilers

OIL-FIRED CENTRAL FURNACE

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL VENTED ROOM HEATER MODELS RH-25-6 RH-35-6 EFFECTIVE DATE SEPTEMBER 2003

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

FOR FORCED HOT WATER MODEL NUMBERS: 15045, 15070, 15096, 15120, 15145, 15175, 15195, 15245, 15295

G615/11 Cast Iron Boiler

USER'S INFORMATION MANUAL

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

User s Information Manual Models:

User s Information Manual

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

15B SERIES Cast Iron Gas Fired Boilers For Forced Hot Water

USER S INFORMATION MANUAL

15B SERIES Cast Iron Gas Fired Boilers For Forced Hot Water

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

ECLIPSE INFORMATION GUIDE

Universal Fire Tube Boiler Wall Mount Models

Forced draught natural gas/propane burner

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Indirect gas-fired air heater

INSTALLATION AND OPERATING MANUAL

GWH-425-EF-N GWH-425-EF-L. Water heaters for use with Natural and L.P.G.

PrecisionTemp Shower-Mate

4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

EVO DUO/EVO MICRO HIGH EFFICIENCY WATER HEATERS AND HEATING BOILERS

(Flow Modulated with Electronic Ignition)

DIVISION FINNED WATER-TUBE WATER HEATERS

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

User s Information Manual

DIVISION FINNED WATER-TUBE BOILERS

User s Information Manual

Transcription:

EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net

Safety Instructions - Read Before Installing & Operating Equipment Waarrniing:: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life A) This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B) Before operating equipment smell around the appliance area for gas. Be sure to smell next to the floor because some gas (specifically L.P.) is heavier than air and will settle to the floor. C) If you smell gas: 1) Do not try to light any appliance 2) Do not touch any electric switch 3) Do not use any phone in the building 4) Contact your gas supplier immediately using a neighbor s phone 5) Follow the gas supplier s instructions D) Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don t try to repair it, call a qualified service technician. Force or attempted repair may result in afire or explosion. E) Do not use appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Operating Instructions Quick Reference 1) Read all instructions prior to operating equipment. 2) Set the thermostat to the lowest setting. 3) Turnoff all electric power to the appliance. 4) This device is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 5) If the gas control knob is not in the OFF position, turn knob clockwise to the OFF position. 6) Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, stop immediately. 7) Turn gas control knob counter-clockwise to ON. 8) Turn on all electric power to the appliance. 9) Set the thermostat to the desired setting. 10) If the appliance does not operate, follow the instructions. Turning Gas Off To Appliance Quick Reference 1) Set the thermostat to lowest setting. 2) Turn off electric power to the appliance if service is to be performed. 3) To turn off gas to the appliance, turn the gas control knob clockwise to OFF.

Contents Safety Instructions Product Features 1 Installation 3 Start Up 6 Maintenance 8 Trouble Shooting 9 Parts 12 Over fifty years of engineering and product development have gone into your new Columbia boiler. Its quality and design are unsurpassed. Properly installed and maintained, it will provide many years of efficient and dependable operation. Please read this instruction manual carefully. The information contained within is designed to help you maintain peak performance from your unit. Product Features ASME Coded Boiler Registered with National Board Factory Mounted / Wired Burner and Controls Fully Insulated Heat Exchanger with Powder-Coated Cabinet Packaged with Standard Five Gallon per Minute Tankless Coil (Domestic Hot Water) Equipped with Triple Aquastat, Circulator, Temperature / Altitude Gauge and Gas Regulator Outfitted with Additional Orifices to Achieve a Variety of Heat Inputs Provided with a Lifetime Limited Warranty i

EMG-31 120 EMG-31 140 EMG-31 160 Input (Btu/Hr)* 120,000 140,000 160,000 IBR Heat Capacity (Btu/Hr) 88,000 101,000 114,000 Valve Capacity (Lbs/Hr) 160 160 160 Max Water Pressure (Psi) 30 30 30 Burner Model Carlin EZ-Gas Carlin EZ-Gas Carlin EZ-Gas Fuel Type Nat. Gas L.P. Gas Nat. Gas L.P. Gas Nat. Gas L.P. Gas Orifice Size 0.242 11/64 0.250 13/64 0.290 7/32 Fuel Input Rate (Cfm) 1.95 0.79 2.28 0.95 2.60 1.06 Max. Inlet Pressure ( W.C.) 11 11 11 11 11 11 Min. Inlet Pressure ( W.C.) 5 5 5 5 5 5 Manifold Pressure ( W.C.) 3.5 3.5 3.5 3.5 3.5 3.5 Head Position Factory Set Factory Set Factory Set Factory Set Factory Set Factory Set Air Shutter 31% 30% 45% 42% 65% 78% Draft Over Fire ( W.C.) -0.02-0.02-0.010-0.02-0.005-0.005 Draft in Stack ( W.C.) -0.02-0.02-0.02-0.015-0.02-0.02 CO 2 Reading 9.0% 11.0% 9.0% 11.0% 9.0% 11.0% AFUE 83.8% 83.8% 83.0% 83.0% 82.2% 82.2%

Boiler Dimensions Water Content 21 Gallon Coil Capacity 5 GPM A) Jacket Height 45 B) Jacket Width 21 C) Hydronic Supply Height 43 D) Coil Supply Height 41 E) Burner Height 8-1/2 F) Hydronic Return Height 21-1/2 G) Flue Pipe Diameter 6 H) Washout 21-1/2 I) Jacket Depth (Including Flange) 21 Depth Front to Rear w/ Burner 29-3/4 Hydronic Supply Size 1-1/4 Hydronic Return Size 1-1/4 Washout Size 3/4

Installation Procedure Waarrniing:: Unit installation must be performed only by a qualified serviceman that is familiar with state and local codes. 1) Inspect the boiler package to ensure that no damage occurred during shipment. Please contact the distributor immediately if there is any sign of damage. 2) Maintain the boiler package in its protective crate as long as possible to prevent any damage when positioning the boiler. When the boiler package is located adjacent to its final position, the protective crate may be removed by first cutting the banding (Note: bands are under tension and will spring back when cut) and then by prying the individual crate panels. In addition, remove the lag bolts which hold the boiler onto the skid. 3) Place the boiler on a level floor as near to the chimney as possible. Adhere to the following minimum clearances to combustible material: a. Floor Non Combustible Floor Only b. Sides 6 c. Rear 6 d. Front 24 e. Top 38 f. Chimney Connector (Vent Pipe) 18 For clearances less than the listed values, please consult National Fire Protection Agency (NFPA) -54 National Fuel Gas Code Table 6.2.3(B). 4) Ensure that there is adequate combustion air for the burner. Lack of adequate combustion air may result in noisy combustion, erratic burner operation, and/or nuisance lock outs. In addition, the lack of combustion air will result in a shift of the burner s performance curve and may result in the generation of CO gases inside of the heat exchanger. Please refer to the Start Up Procedure & Annual Maintenance Requirement sections for instructions on setting up and servicing the burner. For installations in utility rooms or closets, it is necessary to provide two separate ventilation openings in the door (one located at 12 and the other 60 ). Each opening shall be 160 square inches in size. For installations in buildings with tight construction (little fresh air infiltration), it is necessary to place an opening in the exterior wall that is 160 square inches in size and is located adjacent to the boiler. 5) Install piping for the hydronic and domestic hot water systems. Utilize the 1-1/4 coupling located on top of the boiler for the hydronic system supply and the 1-1/4 nipple at the midpoint of the front face for the hydronic system return. Connect the hot water system to the 1/2 copper fittings located on the coil plate. The right side adapter is for incoming cold water and the left side for outgoing hot water. Pipe the hydronic and hot water systems as detailed in the following figure. Ensure that all fittings are tight before filling the system. 6

Note: Installer responsible for ensuring that piping conforms to all applicable codes 7

6) Wire 120 VAC to the aquastat control. Ensure that the hot wire (black) is connected to the L1 connector, the neutral wire (white) to the L2 connector and the grounding wire (bare) to the green screw in the control panel. The burner, circulator and control are installed at the factory and do not require any additional wiring. In addition, it is recommended that a service disconnect be installed in line with the boiler so that the system may be de-energized for maintenance and emergencies. All wiring performed at the installation must comply with local code and NFPA -70 National Electric Code. See burner manual and control manual for wiring instructions. 7) Follow burner manufacturers instructions for preparation, installation, mounting and operation of the burner. 8) Connect the flue from the boiler to a 6 listed venting system. For chimney vent systems the maximum horizontal length must not exceed 10. Listed draft boosters and regulators may be used to increase or decrease the draft respectively. The chimney flue must extend 3 above the highest point of the roof line and 2 above the highest structure located in a 10 radius Start Up Procedure 9) Make sure service switch to boiler is off. 10) Make sure boiler has been filled with water until entire system has been purged of air (System pressure must not exceed 30 PSI). 11) Check burner and install desired orifice. See burner manual for instructions. All units are shipped from the factory with an orifice for each firing rate and natural gas or LP gas. Select the correct orifice for you application from the chart in this manual and install per burner instruction manual. 12) Make sure all manual shut off valves in the gas line are open. 13) Bleed off any air in the gas line by attaching a 1/8 NPT nipple and stop cock to the inlet side of the gas valve. Once a faint smell of gas is noticeable at the fitting, immediately shut off the stop cock. Allow the gas to dissipate for a period of five minutes prior to proceeding to the next step. 14) Set the low and high limit of the aquastat operating control to 160 o F and 180 o F, respectively. 15) Apply power to the system by turning the service switch on. 16) Review the burner manual for additional start-up and operating instructions. Burner Adjustment See burner manual for complete adjustment and operating instructions. Note: The combustion chamber takes approximately 2 hours to cure after starting burner operation. During that time elevated CO levels will occur until the chamber is cured. 17) For chimney vent applications drill out a small sampling port in the stack (locate approximately 6 away from the boiler). 8

18) Attach a 1/8 NPT nipple and stop cock to the outlet side of the gas valve. Regulator Adjustment Screw 19) Attach a manometer to the nipple / stop cock assembly and take a reading of the gas pressure. 20) Make sure the manifold pressure is set at 3.5 W.C. Adjustments can be made to the manifold pressure by turning the set screw located on the gas valve. Gas pressure is increased by turning the set screw clockwise and decreased by turning the screw counterclockwise. 21) Allow the boiler to fire for a period of 10 15 minutes in order to reach the desired operating temperature. 22) Take a flue measurement at the sampling port. Draft should be slightly negative for chimney vent applications (-0.01 to -0.04 ). Adjustments to the draft can be made by installing a listed draft inducer or draft regulator. 23) Take a CO 2 measurement using a combustion analyzer. Adjust the air shutter so that the CO 2 reading measures 9.0%. Increase the air shutter opening to decrease the CO 2 value and decrease the air shutter opening to increase the value. 24) Use the combustion analyzer to verify that the CO level is below 100 ppm and that the flue temperature is above 375 o F. 25) Cover the drilled out sample port either by applying a silicon sealant or high temperature tape. It is important to cover the sample port to prevent flue gases from infiltrating through the opening. Annual Maintenance Requirements 1) Inspect gas line for leaks. 2) Inspect exhaust venting for leaks. 3) Clean blower wheel. 4) Inspect electrode tips for unnecessary wear. 5) Take an ohmmeter reading of the flame sensor. 6) Clean air intake. 7) Inspect coil gasket (retighten bolts if necessary). 9

Trouble Shooting the System See burner manual for trouble shooting burner related problems. Draft Take a draft reading; draft should be -0.02 for chimney vent Down drafts Insufficient draft Install a listed vent cap Install a listed draft inducer Excessive draft Install a listed draft regulator Trouble: Boiling Noise in Top of Boiler Source Procedure Causes Remedy Air Trapped in Boiler / System Check if boiler / system is properly vented (purged) Defective float vent Waterlogged expansion tank Replace vent Drain tank Manual air vent requires venting Improper piping (air trapped at highest point of piping) Open air vent Install air vent at highest point of piping Trouble: Too Much Heat Source Procedure Causes Remedy Circulator Check to see if Aquastat is operating properly Circulator does not stop running Repair Thermostat Check thermostat settings and calibration Thermostat set too high Thermostat defective Reset thermostat Replace thermostat Thermostat out of calibration Recalibrate thermostat Flow Valve Check to see if flow valve is operating properly Flow valve dirty & stuck Flow valve defective Clean flow valve Replace flow valve Trouble: Insufficient Domestic Hot Water Source Procedure Causes Remedy Operating Control Check operating control Setting too low Set operating control to 180 o F Coil Heat Exchanger Inspect coils for fouled surfaces and / or flow restrictions Flow restriction Fouled surfaces on heat exchanger Remove restriction Clean heat exchanger surface 10

Trouble: Insufficient Heat Source Procedure Causes Remedy Circulator Check if circulator is operational Coupling worn or broken Pump binding Replace coupling Replace pump Circulator motor burned out Wiring from operating control defective Replace circulator motor Repair wiring Thermostat Check thermostat settings Settings too low Increase setting Check thermostat location Bad location due to heat buildup Move thermostat to an alternate location Flow Valve Check flow valve for sticking in partially closed position Out of calibration Flow valve not opening fully Recalibrate or replace thermostat Clean or replace flow valve Radiation Check radiators for air Radiators air bound Bleed radiators Check to ensure radiators Radiators inadequate Install alternate radiators are properly sized Boiler Tankless Coil Piping Burner Determine required heat load Check usage of domestic hot water Check to ensure piping is properly sized Increase gas manifold pressure by opening up the gas valve Boiler too small for application Demand too large Piping inadequate Decrease in gas line pressure Additional heating capacity required Install flow regulator Additional boiler capacity required Repipe system Check with gas company for changes in service Check for leaks upstream of burner 11

Available Replacement Parts Item Description Boiler Part Numbers 307120 FT Baffle (8 Required) 305712 FT 6 Flue Box 337070 Gasket Material for Flue Box (25 spool) 790330 Columbia Blank Coil Plate with 1/8 and 3/4 Tapping 481011 Columbia Coil Gasket 530675 Columbia 5 Gallon Coil Assembly with Gasket (Boxed) 337350 FT Fire Chamber 221750 FT Base Assembly Boiler Accessory Part Numbers 535030 Taco 007 Circulator Pump 559560 Altitude Gauge 1/4 x 2-1/2 Round 575020 Relief Valve (3/4 Male) 12