Diamond Windows & MCP Detectors for Synchrotron Applications

Similar documents
Instrumental technique (MCP detectors) - Kamalesh ( )

Customized MCPs for Analytical Instruments. An MCP for every application

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

PRODUCT OVERVIEW. Precision and Vacuum Technology.

Vacuum Quality Assurance in Practice

Fiber Optics. VIS / NIR Multimode, Feedthroughs. Ultrahigh Vacuum CF Flange Feedthrough. 4 x 1 CF Flange Feedthrough

About PREVAC. PREVAC was founded in 1996 in Rogów, Upper Silesia, Poland.

Unique Solutions for Your Research. Introduction to Velocitas VMI. Contents.

Vacuum requirements and Beamline interface at the VUV-FEL User Facility

LECTURE 11. Dr. Teresa D. Golden University of North Texas Department of Chemistry

Doc. No. SP R0. CXI Reference Laser. Prepared by: Jean-Charles Castagna Signature Date Design Engineer

PRECISION AND VACUUM TECHNOLOGY

Physics Requirements for the CXI Detector Stage

2016 Ideal Vacuum (505) V 1.1

Surface Concept Product Catalog 2014

Kurt J. Lesker in the Cryogenic Community. Dr. Glynn Dyson Cryogenics Cluster Day 19 th September 2014

Experimental Particle Physics PHYS6011 Joel Goldstein, RAL

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Diamond Detectors Ltd. Fabrication and Packaging Capabilities. Kevin Oliver

Motion Control and Precision Positioning in Vacuum Environments

Doc. No. SP R0. CXI Detector stage. Prepared by: Signature Date Jean-Charles Castagna Design Engineer

An FT-NIR Primer. NR800-A-006

Variable Temperature Microprobe Systems

MOXTEK MULTI-LAYER OPTICS AND X-RAY TECHNOLOGY

Aging measurements on triple-gem detectors operated with CF 4 based gas mixtures

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

RAMAN SPECTROSCOPY See more, faster than ever before

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

HIGH POWER FIBER OPTIC PATCHCORDS

SYNCHROTRON RADIATION ABSORPTION AND VACUUM ISSUES IN THE IR*

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

Recent Advances in Large Area Micro-channel Plates and LAPPD TM

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

More Precision. Innovative Sensor Technologies. Displacement Distance Position. Dimension Temperature Colour

Exhibitor Listing S48 S11 S46 S22 S24 S32

First results and developments of the multi-cell SDD for Elettra and SESAME XAFS beam lines

Laser Safety Products. Edition 20

Ulster Bank Business Achievers Award Emerging Technology

ELD500 PRECISION LEAK DETECTOR

Compact Raman spectrometer system for low frequency spectroscopy

Spectrum Detector, Inc.

CCD and CID solid-state detectors

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

LHCb Rich Detectors Control and High Voltage Systems

Compact Laser MBE system

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Gaseous detectors. 1

Fast Cycle Water Vapor Cryopump

Saintech Ion Beam Systems - Ion Current Monitor

Source Test and Characterization Program

Heated tools. Semiconductor equipment

Fast Cycle Water Vapor Cryopump

Office of Nonproliferation and Verification Research and Development University and Industry Technical Interchange (UITI2011) Review Meeting

VACUUM PERFORMANCE IN THE MOST RECENT THIRD GENERATION SYNCHROTRON LIGHT SOURCES

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

LEARNING SPECIAL HAZARD DETECTION TYPES

WHAT IS LASER ULTRASONIC TESTING?

Table of Contents. Check the LCLS Project website to verify 2 of 12 that this is the correct version prior to use.

4.8 FARADAY CUP ASSEMBLY OPTION

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

California, Berkeley, CA ABSTRACT 1. INTRODUCTION

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

New Generation of UV, IR and γ - ray sensors with Carbon Nano-Tubes (CNT)

Custom Products Gallery

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

thermal management features such as temperature setpoint control, temperature ramp rate control, and process heating.

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

SILICON SENSOR ACTIVITIES AT SINTEF MINALAB. Marco Povoli, Angela Kok, Ozhan Koybasi

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Status and perspectives of the Virgo detector

(HR) Heating Resistors

Understanding total measurement uncertainty in power meters and detectors

Sensor solutions for the graphics industry

Spot on Fraunhofer IAF

Technical specifications of FT-IR Spectrometer

Temperature dependent Components within the Pyroelectric Detector

IntegraTorr Sputtered Non-Evaporable Getter. We support your innovation

Indium Gallium Arsenide Detectors

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

Cryopumps, Cryogenics

An overview of the Science and Technology Facilities Council capabilities in healthcare

INNOVATIVE WATER VAPOR CRYOPUMP TECHNOLOGIES PRODUCT CATALOG

Applications and Accessories, Cryo Pumps

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Scientific vapor pumps

Variable Temperature Options for Optical Experiments

Delta Doped L3 CCD Imagers for Low Surface Brightness UV Astronomy: From GALEX to the IGM

LCLS Instruments. Jerry Hastings June 20, 2008 LCLS

Benefit from our experience and competence Application-focused solutions from UV to IR

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Optical Properties of Blocking Glass in the WFC3 IR Channel

to get there. together. Infrared Sources Swiss made

SORB-AC Cartridge Pumps MK5 Series

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Chemistry Instrumental Analysis Lecture 14. Chem 4631

Transcription:

Torr Scientific Ltd. Specialists in UHV, Optical and X-ray Components Diamond Windows & MCP Detectors for Synchrotron Applications www.torrscientific.co.uk

Torr Scientific Ltd. Specialists in UHV, Optical and X-ray Components Welcome to Torr Scientific s Synchrotron Products David Bates, Managing Director Torr Scientific Limited is an innovative, ISO9001:2008 BSI registered company, that brings together a unique range of expertise, skills and equipment from the worlds of thin film vacuum coating, vacuum instrumentation and electro-optics. The company was established in 1998 and operates under two main divisions: Vacuum Optics offering UHV viewports, AR coated optics and general vacuum products and X-Ray and Electron-Optical (XEO) offering anodes, surface analysis instruments and products for synchrotron applications. All products are manufactured in a state-of-the-art factory located in Bexhill-on-Sea UK, under contamination-free, clean room conditions and facilities include vacuum furnaces, TIG welding, helium leak testing, e-beam and sputter coating systems, a material characterisation laboratory and precision machining department. The company welcomes enquiries for both standard and non-standard products, so to discuss your requirements, please contact Torr Scientific direct or your local representative.

Diamond Windows for Synchrotron Applications CVD Diamond Tolerance of : Flatness: Thermal Conductivity: ±25 µm <4 µm/cm Up to 1800 W/mK (1000-1500 W/mK typical) Density: 3.5 g/cm 3 Young s Modulus: Growth Side Surface Finish: Nucleation Side Surface Finish: 1220 GPa <100 nm R a <30 nm R a Synchrotrons are capable of generating beams over a wide spectral range and therefore optical components should exhibit high transparency to accommodate such wavelengths. Diamond is unique among all known materials due to its wide spectral transparency but is not a cost-effective solution in its natural form. Synthetic diamond, however, produced in the laboratory by chemical vapour deposition (CVD) techniques at a fraction of the cost, has very similar properties to natural diamond. This includes extreme hardness, high thermal conductivity and the necessary transparency for optical wavelengths that range from 220 nanometres to beyond 100 microns, making CVD diamond an ideal choice for synchrotron applications. CVD diamond benefits include: Exceptional broadband infrared transparency Excellent thermal conductivity High fracture strength Transparency in the optical and ultraviolet spectrum Low scatter in infrared Low thermal expansion coefficient Transmission Curve - CVD Diamond Optical transmission for CVD diamond showing good transparency from UV through to IR (note the varying horizontal scale). The low optical absorption, high thermal conductivity and physical and chemical ruggedness of the diamond, mean that it can tolerate high radiation flux for extended periods compared with other window materials. Please note that the optical transmission curves are approximations and should be used for reference only Transmission % 100 90 80 70 60 50 40 30 20 10 0 0 5 10 15 20 25 30 Photon energy (kev) The transmission of X-rays through 250 µm thick CVD diamond as a function of photon energy, showing around 15% attenuation at 10 kev, and less than 5% attenuation above 15 kev.

Diamond Windows for Synchrotron Applications CVD Diamond Seal Type Maximum Temperature Minimum Temperature Maximum Rate of Temperature Change Window Roughness Leak Rate Pressure Range Braze 450 C 304L, 600 C 316LN -20 C 3 C per minute 30 nm R a <1x10-10 atm-cc/sec (He) 1 bar to 1x10-11 mbar Torr Scientific offers an unrivalled range of both standard and non-standard CVD diamond viewports for synchrotron applications. UHV Viewports are offered as standard in CF flanges using high grade 304L or 316LN stainless steel, but can also be supplied in ISO, KF or custom designed flanges on request. The viewports comprise a diamond window which is synthetically produced by a chemical vapour deposition (CVD) process, and are manufactured in contamination-free, cleanroom conditions. The rugged construction of the CVD diamond viewports allows repeated bake-out with UHV performance and the transmission properties extend from visible, through FIR, to beyond 100 microns. The window is polished to a surface roughness of 30nm R a, has high thermal conductivity and good biocompatibility. Various anti-reflective coatings to match customer reflectance requirements can also be catered for. Non-standard CVD diamond viewports are available on request, so contact TSL direct or your local representative with your requirements. Part Number Type OD View Diameter Optic Material Weld Ring Material Window Grade VPZ16CVDDX NW16CF 34 15 0.5 12.7 304L Kovar X-ray VPZ16CVDD NW16CF 34 15 0.5 12.7 304L Kovar Optical VPZ16CVDDX-LN NW16CF 34 15 0.5 12.7 316LN Kovar X-ray VPZ16CVDD-LN NW16CF 34 15 0.5 12.7 316LN Kovar Optical VPZ38/15CVDDX NW35CF 70 15 0.5 12.7 304L Kovar X-ray VPZ38/15CVDD NW35CF 70 15 0.5 12.7 304L Kovar Optical VPZ38/15CVDDX-LN NW35CF 70 15 0.5 12.7 316LN Kovar X-ray VPZ38/15CVDD-LN NW35CF 70 15 0.5 12.7 316LN Kovar Optical VPZ38/20CVDDX NW35CF 70 20 1.0 12.7 304L Kovar X-ray VPZ38/20CVDD NW35CF 70 20 0.5 12.7 304L Kovar Optical VPZ38/20CVDDX-LN NW35CF 70 20 1.0 12.7 316LN Kovar X-ray VPZ38/20CVDD-LN NW35CF 70 20 0.5 12.7 316LN Kovar Optical VPZ38/32CVDDX NW35CF 70 32 1.0 12.7 304L Kovar X-ray VPZ38/32CVDD NW35CF 70 32 0.7 12.7 304L Kovar Optical VPZ38/32CVDDX-LN NW35CF 70 32 1.0 12.7 316LN Kovar X-ray VPZ38/32CVDD-LN NW35CF 70 32 0.7 12.7 316LN Kovar Optical

Diamond Windows for Synchrotron Applications Water Cooled X-Ray UHV Windows Seal Type Braze Maximum Temperature 200 C Minimum Temperature Maximum Rate of Temperature Change Window Roughness Leak Rate Pressure Range -20 C 3 C per minute 30 nm R a <1x10-10 atm-cc/sec (He) 1 bar to 1x10-11 mbar High Thermal Conductivity CVD diamond windows used in synchrotron applications can be subjected to high thermal loads due to the absorption of low-energy X-rays. Since CVD diamond possesses excellent thermal conductivity, the absorbed energy is quickly dissipated to the edge of the diamond window where it can be removed by a simple and efficient cooling technique. Water-cooled CVD diamond windows are therefore ideal in applications which involve higher frequencies or higher power. Torr Scientific manufactures a standard range of water-cooled CVD diamond windows, supplied in either 304L or high-grade 316LN CF flanges. Bespoke windows are also available on request. Part Number Type OD View Diameter Optic Material Weld Ring Material Window Grade VPZ38/15CVDDX-WC NW35CF Double sided 70 15 0.5 12.7 304L OFHC Copper X-ray VPZ38/15CVDD-WC NW35CF Double sided 70 15 0.5 12.7 304L OFHC Copper Optical VPZ38/15CVDDX-LN-WC NW35CF Double sided 70 15 0.5 12.7 316LN OFHC Copper X-ray VPZ38/15CVDD-LN-WC NW35CF Double sided 70 15 0.5 12.7 316LN OFHC Copper Optical VPZ38/20CVDDX-WC NW35CF Double sided 70 20 0.5 12.7 304L OFHC Copper X-ray VPZ38/20CVDD-WC NW35CF Double sided 70 20 0.5 12.7 304L OFHC Copper Optical VPZ38/20CVDDX-LN-WC NW35CF Double sided 70 20 0.5 12.7 316LN OFHC Copper X-ray VPZ38/20CVDD-LN-WC NW35CF Double sided 70 20 0.5 12.7 316LN OFHC Copper Optical

MCP Detectors for Synchrotron Applications MCP Detectors MCP Type Open Area Ratio 60% Gain PHD Output Strip Current <20 µa Mounting MCP hard edge 10 6-10 7 typical FWHM/A<120% P22G (Green) High resolution Al backed Detector is mounted on standard ISO100 or CF100 Options Ø18 mm, Ø25 mm, Ø40 mm & Ø50 mm Single, double and triple MCP versions High resolution screens with P20, P22, P43, P46, P47. Others available on request Fiber optic or glass output window Anti-reflective coating for high efficiency light output Non-magnetic MCP detectors available Feedthrough Type SHV Taper coupling to CCD possible MCP detectors are used in a variety of applications including UV, VUV and EUV spectroscopy, atomic and molecular physics, TOF mass spectrometry of clusters and biomolecules, surface studies and space research. These vacuum imaging detectors can be supplied as a totally assembled unit that can be easily mounted on any support substrate or directly on a vacuum flange. They can also be supplied pre-mounted on standard CF or ISO vacuum flanges. As the MCP is operated with a high voltage of approximately 1kV per stage, a relatively high degree of vacuum is required. If the MCP is operated at a deficient vacuum, not only does the noise increase due to the ion generation in the channels, but also the lifetime may be shortened and, in the worst case, the MCP may be damaged by discharge. It is therefore recommended that the MCP be operated at the highest possible level of vacuum. When using a new MCP, it is recommended that before applying a voltage to it the system be evacuated at a pressure of 5 x 10-6 torr or below for more than 24 hours. If the evacuation time is short or the degree of vacuum is deficient a discharge may occur. Standard configurations include either a CF100 or ISO100 flange, a glass window and a P22G yellow/green phosphor screen. Alternative designs incorporating different MCPs, flanges and screens can be quoted on request. Versions with fibre optic outputs for coupling to CCD or CMOS cameras, can also be manufactured. Standard Configuration: CF / ISO 100 P22G yellow / green phosphor screen Alternative flanges and screens available upon request Optional Fibre Optic Coupled Camera: Offers a digital and / or monitor output image Coupling to CCD or CMOS cameras Custom fibre taper configurations available Flexible modular design

MCP Detectors for Synchrotron Applications MCP Manipulators for Beam Visualisation & Secondary Electron Detection Plate Outer Diameter 24.8 mm or 38.4 mm Effective Area 20 mm or 32 mm diameter 0.48 mm Channel Diameter 12 µm Channel Pitch 15 µm Bias Angle 8o Open Area Ratio 60% Gain per Plate (min) 10 4 Plate Configuration Single or matched pair chevron stack Output Options Phosphor screen or anode Manipulator Linear Travel 50 mm or 100 mm (longer travels available on request) Reliable Beamline Measurements MCP Manipulators are ideal instruments for beam visualisation and secondary electron detection at synchrotron facilities. The MCP detector can be customised according to the application in question, and are mounted on to a smooth and precise linear shift mechanism (typically offering up to 100 mm linear travel, with longer travels available on request) so it can be moved in and out of the detection zone. Electrical feedthroughs are positioned at the end of the MCP Manipulator, fitted with SHV connectors as standard, with in-vacuum UHV compatible Kapton wire being used throughout for electrical insulation. An optional 3U rack-mounted, high voltage power supply, complete with digital readout is also available. Smooth & Precise Linear Motion At the heart of the MCP Manipulator is a unique linear shift mechanism (LSM) that provides smooth, precise linear motion along the z-axis. Each LSM incorporates a unique kinematically designed external leadscrew mechanism, complete with anti-rotation and anti-deflection systems. Their true UHV performance, precise motion and robust design make them ideally suited for the positioning and manipulation of beam line diagnostics. 2x flange parallelism of conventional designs 2x load-carrying capability of conventional designs Smooth kinematic motion 10,000 cycle lifetime guarantee (3 million cycle option) Demountable bellows assembly MCP Manipulators installed at the Diamond Light Source Two MCP Manipulators are installed on the end station of the second branch of the IO5-ARPES beamline. The branch will measure the angular-resolved photoemission from the spot of VUV light (50-100eV), focused using a Fresnel zone plate into a spot with size <1 micron. The first MCP Manipulator is used as an auxiliary photoemission detector, adding measure of photoemission integrated in both electron energy and angle. This detector provides a high level count rate which is suitable for fast scanning mapping of sample topography. The second MCP Manipulator is placed behind the zone plate optics and sample, providing the beam visualisation behind the zone plate focus, and is used for alignment of the zone plate relative to the required aperture.

Represented by: Torr Scientific Ltd. Specialists in UHV, Optical and X-ray Components Unit 11 Pebsham Rural Business Centre, Pebsham Lane, Bexhill-on-Sea East Sussex, TN40 2RZ, UK Tel: Fax: E-mail: 44 (0) 1424 225228 44 (0) 1424 221899 sales@torrscientific.co.uk Front and back cover image courtesy of the Australian Synchrotron