Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Similar documents
Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Release Control Fire Alarm Systems

Specification/ Data Sheet

Z-20 Fire Control Panels

LifeAlarm Fire Alarm Controls

TrueAlert Multi-Candela Notification Appliances

TrueAlert Notification Appliances

Releasing System Peripherals

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances

TrueAlert Multi-Candela Notification Appliances

TrueAlert ES Addressable Notification Appliances

TrueAlert Addressable Notification Appliances

TrueAlarm ES Analog Sensing

TrueAlert Addressable Notification Appliances

LifeAlarm Fire Alarm Control Panels

TrueAlarm Analog Sensing

TrueAlert Addressable Notification

4007ES Fire Control Panels

IDNet and MAPNET II Addressable Devices

Multi-Point Peripherals

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Multi-Point Peripherals

System Accessories, LCD Annunciators

Doc. No Part No Rev. U * T*

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AND ARCHITECT SPECIFICATIONS

TrueAlarm Analog Sensing

TECHNICAL DATA OBSOLETE

Conventional Releasing Control Panel

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

TrueAlarm Fire Alarm Controls

4007ES Fire Control Panels

TrueAlarm Analog Sensing

4007ES Fire Control Panels

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

TrueAlarm Addressable Fire Alarm Control Panels

SLVMC - Oncology & Infusion Remodel & Add 17D /4/2017

30.45 Electric Release PDRP-2001

PSN-1000 & PSN 1000(E) Installation Manual

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Booster Power Supply Manual

4100U City and Relay Cards Installation Instructions

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

Multi-Application Peripherals and Accessories

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

Commercial and Light Industrial Fire Alarm Control Panel

FireFlex DUAL Double Interlock, Self-contained system

AL800ULADA. NAC Power Extender. Installation Guide

Multi-Application Peripherals

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

ADDENDUM to IFC-640 for Factory Mutual Applications

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Remote Booster Power Supplies

July 14, 1999 DF C-100.

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Fire Control Units. Addressable Fire Detection and Basic Control Unit Modules and Accessories. UL, ULC Listed, FM Approved* Features

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

TrueAlarm Smoke Detectors

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC Listed, FM Approved* Features

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

SIGA-CC1 Single Input Signal Module Installation Sheet

ALARMS Fire Alarm Priority 2 Alarm. Fire Alarm Priority 2. Ack Event Time Enable Disable Emergency Operating Instructions.

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Addressable Fire Alarm Control Panel

Signature Series Auto-Sync Output Module (CC1S)

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Panel Remote Annunciators Installation Instructions

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

as required for residential sprinklers intended for use in dry pipe systems.

AL600ULADA. NAC Power Extender. Installation Guide

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

/5121/5122 TrueAlert Power Supply Installation Instructions

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

4010 Fire Alarm Applications Manual

Agent Release Control Panel

June 10, 2002 DF C S2424

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Rev. B. TrueAlert Addressable Controller Application Manual

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

Fire Alarm System Accessories

Reverse Chronological Order by Date of Last Revision... page 2. Numerical Order... page 4. Discontinued/Inactive Data Sheets...

MR-2602 Two Zone Fire Alarm Control Panel

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi CONTROL PANEL

L-Series, Emergency Communication Devices

Print Specification. Publication. Instructions. Specific requirements. General requirements

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

INSPECTION AND TESTING FORM

Transcription:

MANUAL RELEASE - IDNET IN + +IDNET IN - RED NA C+ N A C - COIL SUPERVISION MODULE ( 2 AMP) 28-946 INSTALLATION INSTRUCTIONS 574-437 REV YEL MA IN T A IN /4 "S E P A R A T IO N BETW EEN POW ER LIMITED ( RED/BLK) AND NONPOW ER S L IMIT ED ( YE L /) W IRING DATE CODE: 5 9-9 5 8 NORMAL S IM P L E X T IM E R E C O R D E RC O.G A R D N E RM A.U S A CAUTION: This Control Unit has been arranged for releasing service. Disable all releasing device circuits prior to servicing. Fire Control Panels UL, ULC, CSFM Listed; FM Approved MEA (NYC) Acceptance* Features Releasing control using the Simplex 4ES (or 4U) Fire Alarm Control Panel to provide**: Coverage for multiple areas of Automatic Extinguishing Release and/or Deluge and Preaction Sprinkler System Release including audible escalation of events Control of compatible Listed/Approved 24 VDC automatic control actuators, one per circuit; or two 2 VDC actuators in series per circuit Releasing appliance circuits (RACs) by connecting Notification appliance circuits (NACs) to Suppression Release Peripherals for actuator supervision and control Audible Escalation of Events: Temporal or 2 bpm March Time pattern for first cross-zone alarm 2 bpm March Time pattern to indicate releasing timer active On steady to indicate releasing timer expired and actuator is activated NOTE: Requires NACs dedicated to conventional horn control (not SmartSync operation) with strobes controlled on separate NACs 49-95/-96 Suppression Release Peripheral (SRP) with Dual Command Control: Dual command control requires that both IDNet communications commands and an activated NAC are present to initiate the desired release NAC provides wiring supervision to the actuator including monitoring of coil continuity and short circuit supervision to the coil supervision module Suppression Release Peripheral control features: An on-board DC-DC regulator compensates for voltage drops to the peripheral and ensures proper control circuit voltage over a wide operating range Provides a single RAC for control of actuators for up to 2 A using a 3 A NAC input ( A using a 2 A NAC input) Related system components: 4ES Series control panel with Releasing Appliqué Dedicated NAC output from 4ES (or compatible NAC Extender) Coil supervision module, one per RAC Maintenance Switch, one per RAC Abort Switch connected via an addressable interface module UL listed to Standard 864 * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 344. of the California Health and Safety Code. See CSFM Listings 765-26:25 and 73-26:33 (SRP) for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control Actuator Control Circuit Agent source Maintenance Disconnect Switch (with indicator lamp) Suppression Release Peripheral Typical addressable initiating devices Actuator DISCONNECT / FIRE RELEASING DEVICE Agent discharge path Coil supervisory module SUPPRESSION RELEASE PANEL Release appliance circuit 4ES Control Panel with Suppression Release Appliqué Power for indicator lamp (if required) IDNet communications Dedicated NAC circuit 4ES Series Releasing Control Typical Block Diagram Introduction When combined with Suppression Release Peripherals, the 4ES series fire alarm control panel provides actuator supervision and control for use in automatic extinguishing, and deluge or preaction releasing systems. Hazard area initiating and notification devices are controlled using either conventional or addressable circuits per standard 4ES capabilities. The necessary releasing system logic is implemented within the 4ES control panel as required for the local application. ** Release Control operation described in this document is also available with 4U Control Panels with software revision.5 or higher. Refer to data sheet S4-3 for model 4ES control panel details including IDNet communications information. S4-4-7 /23

Automatic Extinguishing Release Systems These systems automatically activate electrically controlled actuators for the release of a fire extinguishing agent (such as dry chemical, water spray, foam, CO 2, or clean agent) in response to fire detection device inputs as determined by programming of the host fire alarm control panel. Automatic Extinguishing Release System Panels are required to have a minimum of 24 hours of standby power. Initiating devices must be Listed/Approved for the application, and may be wired either Class A or B. Control actuators must be electrically compatible with the control panel circuits and power supplies, and are wired Class B to provide coil supervision. Deluge or Preaction Sprinkler Systems These systems automatically activate water control actuators in response to fire detection device inputs. Deluge Sprinkler Systems employ open sprinkler heads and provide water flow when the fire detection system activates a common automatic water control actuator. They are used to deliver water simultaneously through all of the system sprinkler heads. This type of system is applicable where the immediate application of large quantities of water over large areas is the proper fire response. Preaction Sprinkler Systems are similar to deluge systems except that normally closed sprinkler heads are used and supervisory air pressure is maintained in the pipe. Operation requires both an activated sprinkler head and an activated fire alarm initiating device with specific programming determined at the host fire alarm control panel. Releasing System Requirements. Releasing actuators are controlled from a Suppression Release Peripheral (49-95 or 49-96). Connections are 2-wire, Class B releasing circuits with only one 24 VDC actuator per circuit. Where applicable, two, 2 VDC actuators in series, or one 2 VDC actuator with manufacturer supplied resistor may be used. 2. Coil Supervision Module 28-946 must be wired electrically before the actuator and located in the actuator wiring junction box. (Refer to diagram on page 5.) The connected RAC provides continuity supervision of the actuator coil and wiring and provides short circuit supervision to the coil supervision module. 3. Cross-zoning or other alarm initiation logic per system requirements, is to be implemented by programming at the fire alarm control panel. 4. UL Listed Automatic Extinguishing Releasing operation requires that: battery standby must be a minimum of 24 hours with 5 minutes of alarm and that listed actuators are used, refer to list on page 6. Releasing System Requirements (Continued) 5. FM Approved Automatic Extinguishing Release requires secondary standby to be a minimum of 24 hours with 5 minutes of alarm. Actuators must be electrically compatible. 6. FM Approved Deluge and Preaction Sprinkler operation requires that: initiating device circuits be Class A and wired to Listed/Approved devices; standby power capacity must be a minimum of 9 hours with minutes of alarm; and that compatible Automatic Water Control Valves must be used. (Refer to actuator list on page 7.) 7. Maintenance Switches, one per RAC, are required per NFPA 72, the National Fire Alarm and Signaling Code to allow the system to be tested or serviced without actuating the fire suppression systems. Their use may not be allowed in some jurisdictions, always confirm local requirements. When used, Simplex Maintenance Switches are required to ensure that operation initiates a supervisory condition. 8. Abort Switches are available when abort operation is required. When used, connect to an addressable Supervised IAM model 49-9 or similar addressable adapter module. The Simplex abort switch and the IAM mount in a single gang box, 2-/2 minimum depth. 9. Addressable Manual Releasing Stations are used to initiate activation of the releasing actuators with the appropriate time delay implemented by the fire alarm control panel.. Notification Requirements. Each hazard area typically requires general audible and visible fire alarm notification and additional dedicated NACs for area releasing status notification. Suppression releasing is compatible with conventional panel mounted NAC modules as well as for use with the 49 IDNet NAC Extender.. Additional Suppression Release Peripheral Reference. Refer to Installation Instructions 579-385. Additional Releasing Systems Reference For additional information, refer to Factory Mutual Research Corporation (FMRC) FMRC Approval Guide, FM Approval standard Deluge Systems and Preaction Systems. Please note that proper operation of releasing control systems requires that the system design, installation, and maintenance be performed correctly and in accordance with all applicable local and national codes, and equipment manufacturer s instructions. No liability for total system operation is assumed or implied. 2 S4-4-7 /23

Product Selection 4ES Releasing Control System Modules Model Description Reference 28-946 Coil Supervision Module Required, one per RAC, mounts in the releasing actuator wiring junction box; see specifications section for details 28-Series* Maintenance Switches One per RAC; flush or surface mount; indicator lamp models require separate 24 VDC wiring 28-956* Flush mount 28-957* Surface mount Abort Switch As required, connects via an IDNet addressable interface module; mounted on a single gang stainless steel plate; installation requires a single gang box, 2-/2 (64 mm) minimum depth * Refer to data sheet S28- for Abort and Maintenance switch details. Releasing Appliqués, Required for 4ES Suppression Releasing Applications Model Description 4-983 English Suppression Releasing Appliqué; field applied (same appliqué as is used on the 4-983CAF French Simplex model 4 Suppression Release Panel) Suppression Release Peripheral and Accessories Model Description Reference 49-95 49-96 2975-9227 49-982 Basic Suppression Release Peripheral on mounting plate Suppression Release Peripheral mounted in NEMA red box; required for ULC listing NEMA red mounting box; required for 49-95 Red LED IDNet communications indicator option kit; mounts on door of 2975-9227 box Requires mounting box 2975-9227, ordered separately Includes LED indicator on front of door These items are included with model 49-96 Additional Product Data Sheet Reference Subject Data Sheet Subject Data Sheet Releasing System Abort and Maintenance Switches Addressable Manual Stations for Releasing Applications Addressable Manual Stations for Standard Applications S28- S499-2 4 Series, Panel Mount 24 Point I/O and Annunciator Modules 4 Series, Remote Mount 24 Point I/O and Annunciator Modules S4-32 S4-5 S499- TrueAlarm Sensors and Bases S498-9 4ES Basic Control Panels S4-3 TrueAlert Electronic Horns S49- Supervised IAM S49- TrueAlert Non-Addressable Strobes (V/O) S496- Addressable Zone Adapter Modules S49-3 TrueAlert Non-Addressable 4-Wire Horn/Strobes (A/V) S493- Contact your local Simplex product supplier for additional information on compatible IDNet addressable devices and TrueAlert notification appliances. 3 S4-4-7 /23

MANUAL RELEASE MANUAL RELEASE - IDNET IN + +IDNET IN - - IDNET IN + +IDNET IN - CAUTI O N : This Cont r ol Unit has been ar r anged f or r eleasing service. Disable al releasing device circuits prior to servicing. RE D NAC+ NAC- RE D NAC+ NAC- COIL SUPERVISION MODULE ( 2 AMP) 28-946 IN S T A L L A T IO N IN S T R U C T IO N S5 7 4-4 3 7R E VYEL MA IN T A IN /4 " S E P A R A T ION BETW EEN POW ER LIMITED (RED/BLK) AND NONPOW ER S LIMITED ( YEL /) W IRING DATE CODE: 59-958 S IMP LEX TIME RECORDER CO. GARDNER MA. USA COIL SUPERVISION MODULE ( 2 AMP) 28-946 IN S T A L L A T IO N IN S T R U C T IO N S5 7 4-4 3 7R E V YEL MA IN T A IN /4 " S E P A R A T ION BETW EEN POW ER LIMITED (RED/BLK) AND NONPOW ER S LIMITED ( YEL /) W IRING DATE CODE: 59-958 S IMP LEX TIME RECORDER CO. GARDNER MA. USA 4ES Releasing System One-Line Connection Reference HAZARD AREA 2 49-95/-96 Suppression Release Peripheral FIRE RELEASING DEVICE Maintenance Disconnect Switch NORMAL DISCONNECT / Actuator Control Circuit Coil supervisory module Agent source Actuator Class B NAC wiring; dedicated to Suppression Release Actuator IDNet communications NAC for horn control NAC for strobe control Agent discharge path Use separate NACs for horn and strobe control to implement audible escalation of events HAZARD AREA 24 VDC for Maintenance Disconnect status indicator (if required) Actuator Control Circuit IDNet communications (shown as Class B wiring) FIRE RELEASING DEVICE NORMAL Coil supervisory module Agent source Actuator DISCONNECT / Supervised IAM with optional Abort Switch IDNet Addressable devices Class B NAC wiring; dedicated to Suppression Release Actuator Agent discharge path SUPPRESSION RELEASE PANEL NAC for horn control NAC for strobe control Use separate NACs for horn and strobe control to implement audible escalation of events Suppression Release Appliqué wording: 4ES Control Panel with Suppression Release Appliqué SUPPRESSION RELEASE PANEL CAUTION: This Control Unit has been arranged for releasing service. Disable all releasing device circuits prior to servicing. 4 S4-4-7 /23

NORMAL MANUAL RELEASE - IDNET IN + +IDNET IN - SIMPLEX TIME RECORDER CO.GARDNER MA.USA Suppression Release Peripheral Wiring Reference Maximum Release Appliance Circuit (RAC) Wiring Distances from Suppression Release Peripheral to the Valve Solenoid (based on a total drop of.6 V) RAC Output Current (refer to solenoid rating) Distance 8 AWG 6 AWG 4 AWG 2 AWG Total Line Resistance.5 A 74 ft 23 m 8 ft 36 m 88 ft 57 m 3 ft 9 m.6.75 A 5 ft 5 m 79 ft 24 m 26 ft 38 m 2 ft 6 m.7. A 37 ft m 59 ft 8 m 94 ft 29 m 5 ft 46 m.53.25 A 3 ft 9 m 47 ft 4 m 75 ft 23 m 2 ft 36.6 m.6.5 A 25 ft 7.6 m 39 ft 2 m 63 ft 9 m ft 3.5 m.7.75 A 2 ft 6.4 m 34 ft m 54 ft 6 m 85 ft 26 m.53 2. A 9 ft 5.8 m 3 ft 9 m 47 ft 4 m 75 ft 23 m.53 Metric wire equivalents: 8 AWG =.82 mm 2 ; 6 AWG =.3 mm 2 ; 4 AWG = 2.8 mm 2 ; 2 AWG = 3.3 mm 2 NORMAL DISCONNECT / FIRE RELEASING DEVICE DISCONNECT / COIL SUPERVISION MODUL E ( 2 AMP) 2 8-9 4 6 RED INSTAL LATIONINSTRUCTIONS574-437REV NAC+ MAINTA IN /4 " SEPARAT ION BETW EENPOW ERLIMITED ( RED/BLK)ANDNONPOW ER LIMITED ( YEL/BLK) W IRING DATECODE: 59-958 NAC- BLK YEL S BLK Maximum Notification Appliance Circuit (NAC) Wiring Distances to a Suppression Release Peripheral (.5 A to.75 A drop is based on a total drop of 3.4V; 2 A drop is based upon a total drop of.2 V) RAC Output Current (refer to solenoid rating) Distance 8 AWG 6 AWG 4 AWG 2 AWG Total Line Resistance.5 A 25 ft 76 m 399 ft 22 m 635 ft 94 m ft 38 m 3.58.75 A 67 ft 5 m 266 ft 8 m 423 ft 29 m 673 ft 25 m 2.39. A 25 ft 38 m 99 ft 6 m 37 ft 97 m 55 ft 54 m.79.25 A ft 3 m 59 ft 48 m 254 ft 77 m 44 ft 23 m.43.5 A 84 ft 26 m 33 ft 4 m 22 ft 65 m 337 ft 3 m.9.75 A 72 ft 22 m 4 ft 35 m 8 ft 55 m 289 ft 88 m.2 2. A 25 ft 7.6 m 39 ft 2 m 63 ft 9 m ft 3 m.36 Metric wire equivalents: 8 AWG =.82 mm 2 ; 6 AWG =.3 mm 2 ; 4 AWG = 2.8 mm 2 ; 2 AWG = 3.3 mm 2 5 S4-4-7 /23

Specifications Suppression Release Peripheral 49-95 and 49-96 Communications IDNet, one address RAC Output Rating NAC Power Requirements NOTE: 4ES NACs are rated at 3 A; 49 IDNet NAC Extender NACs are rated at 2 A, Extender expansion NACs are rated.5 A Wire Connections IDNet Wiring Distance Reference with 4ES/4U 2 A maximum At nominal 24 VDC, regulated; refer to NAC Power with 49 IDNet NAC Extender A maximum Requirements for more detail Voltage Supervisory Current Alarm Current Reference (RAC current = actuator current) 6 to 32 VDC (nominal 24 VDC) No additional current required, circuit appears as standard end-of-line (EOL) NAC loading RAC Current NAC Current RAC Current NAC Current.5 A.845 A.25 A 2.4 A.75 A.28 A.5 A 2.56 A.87 A.5 A.75 A.7 A 2 A 3 A Screw terminals for input and output wiring, 8 to 2 AWG wire (.82 mm 2 to 3.3 mm 2 ) Up to 25 ft (762 m) from the IDNet source module Up to, ft (348 m) total Class B wiring distance including T-Taps Compatible with Simplex 28-944 Overvoltage Protectors Dimensions See installation reference on page 8 Operating Temperature 32 to 2 F ( to 49 C) indoor operation only Operating Humidity Range to 9% RH at 9 F (32 C) Coil Supervision Module 28-946 Construction Dimensions Wiring Current Rating Compatible UL Listed Valves and Actuators A N S U L Epoxy encapsulated -3/8 W x 2-7/6 L x -/6 H (34 mm x 62 mm x 27 mm) 8 AWG (.82 mm 2 ) wire leads, color coded 2 A Maximum; internally fused at 3 A, non-replaceable MFG. Model Number Coil Details MFG. Model Number *AUTOMAN II-C Assembly; solenoid 7728; coil 25924 2 VDC, 458 ma LPG S k i n n e r AUTOMAN II-C Explosion-Proof Releasing Device; solenoid 3492; coil 3438 82A7 (9767-5D coil) /2 NPS, 5/8 orifice, 24 VDC 24 VDC, 467 ma 82G27 (2383 coil) /2 NPS, /2 orifice *AUTOMAN II-C Assembly; solenoid 68739; 2 VDC, 458 ma coil 25924, ASCO 82A7 (9767-5D coil) 24VDC Solenoid Electric Actuator; solenoid 73; coil 7397 24 VDC, A HV262857 (238 coil) N.C. /2 NPS, /2 orifice *CV9 HF Electric Actuator 73327; may use 9 VDC max, HV264858 (238 coil) N.O. /2 NPS, /2 orifice 7366 in-line resistor for 2 VDC 45 ma R82A7 (9767-5D coil) /2 NPS, 5/8 orifice LP CO2 w/asco solenoid 422934, 24 VDC, 442 ma T82A7 (9767-5D coil) /2 NPS, 5/8 orifice LP CO2 double action solenoid 43948 24 VDC, 438 ma ECH Electrical Control Head (552) LP CO2 3-way selector valve solenoid Pyro- 24 VDC, 438 ma 43349 Chem Explosion-Proof Electric Actuator (5747) Electric Actuator 24 VDC solenoid 57537 24 VDC, 25 ma Removable Electric Actuator (5729).2 A Solenoid 2642 for Solenoid Coupling Assemblies: 264 & 2642; & LPG28/45/9/23-5/55 FM-2 valves; and LPG28-9UL iflow & FM-2 valves 24 VDC, 542 ma 7395SN2ENJNOHC2 (Skinner coil HC2) /4, NPS, /6 7322BN4TNNOCC2 (Skinner coil CC2) /2, 5-3 psi 7322BN4TNLVNOC322C2 (Skinner coil C322C2) /2, NPS,.92 A, 25 psi 7328BN4UNLVNOHC2 (Skinner coil HC2) 7328BN4UNLVNOCC2 (Skinner coil CC2) /2, NPS, 5/8 in. orifice * 2 VDC coils, either wire two in series for 24 VDC activation, or, if available from manufacturer, use series resistor 6 S4-4-7 /23

Compatible FM Approved Water Control Valves FM Group Manufacturer Model Number Details A Skinner LV2LBX25* 24 VDC, W, 458 ma, /2 inch NPS, /2 inch orifice T82A7 B ASCO R82A7 24 VDC, 6.8 W, 7 ma, /2 inch NPS, 5/8 inch orifice 82A7 D ASCO 82G27 24 VDC,.6 W, 44 ma, /2 inch NPS, /2 inch orifice ASCO 8262H85 24 VDC, 22.6 W, 942 ma, /4 inch NPS, /8 inch orifice, stainless steel 7328BN4UNLVNOCC2* 24 VDC, W, 42 ma, /2 inch NPS, 5/8 inch orifice E Skinner 7322BN4TNNCC2 24 VDC, W, 42 ma, /2 inch NPS, 5/8 inch orifice; 5-3 psi rated working pressure F Skinner 7322BN4TNLVNOC322C2 24 VDC, 22 W, /2 inch NPS, 92 ma, 25 psi (725 kpa), /2 inch orifice G Skinner 7395SN2ENJNOHC2 24 VDC, W, 42 ma, /4 inch NPS, /6 inch orifice, 25 psi (725 kpa) rated working pressure I Victaulic Series 753-E solenoid valve 24 VDC, 8.7 W, 2 inch NPS, 364 ma, 3 psi (269 kpa), 2 inch orifice J Viking 59 and 592 Normally closed (NC) 595 and 596 Normally open (NO) Explosion proof solenoid valves, 24 VDC, W, 2 inch NPS, 3 psi (269 kpa), 4. Cv K Viking 6 and 62 NC solenoid valve, 24 VDC, 9 W, 2 inch NPS, 25 psi (725 kpa), 6.2 Cv * For new applications, LV2LBX25 has been replaced by model number 7328BN4UNLVNOCC2. 7 S4-4-7 /23

ON 2 3 4 5 6 7 8 Suppression Release Peripheral Installation Reference Diagram 2975-9227 Box, red with white lettering (supplied with 49-96) Door hinges on left and lifts off for access 4 Knockouts, one each side Door height 8-/8" (26 mm) Door screw fastener 49-982 LED indicator option (supplied with 49-96) Door depth /2" (3 mm) Door width 6-/8" (56 mm) Box depth 4" (2 mm) Box depth with door 4-/6" (3 mm) 49-95 Suppression Release Peripheral assembly (supplied with 49-96) NAC + NAC - IDNet+ IDNet- RAC - RAC + Box height 8" (23 mm) IDNET SUPPRESSION RELEASE PERIPHERAL ASSY 566-4 Box width 6" (52 mm) TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Fire Protection Products Westminster, MA 44- USA S4-4-7 /23 www.simplex-fire.com 23 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.