Guide to interpreting Markings for Single Axis Fire Doors Hinges

Similar documents
Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Controlled Door Closing Devices

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Mechanically operated locks and locking plates

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

Panic and Emergency Exit Devices

Code of Practice: Hardware for Fire and Escape Doors

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Code of Practice: Hardware for Fire and Escape Doors. Issue No.2 June 2006 THE GUILD OF ARCHITECTURAL IRONMONGERS

Electromagnetic Locking Devices

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

Best practice guide. Hardware for sliding doors and folding doors to BS EN in association with. Association of Building Hardware Manufacturers

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

GUIDELINIE ECB S R10. March European Certification Body GmbH

Best practice guide. Electrically powered hold-open devices to BS EN in association with. Association of Building Hardware Manufacturers

Hardware for Sliding Doors & Folding Doors

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

F O C U S D O O R C L O S E R S

Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

SELF PRESERVATION SOCIETY By Jim Creak

PANIC EXIT HARDWARE DX-500 Serie

Electromagnetic Locking Devices Performance Requirements

Loss Prevention Standard

Guide to Gate Safety Legislation & the Machinery Directive

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

Maintenance. Why Maintain Fire Doors? Regulations

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

Construction Products Directive

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

The Association for Specialist Fire Protection

European Technical Assessment. ETA-02/0020 of 11 December English translation prepared by DIBt - Original version in German language

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

TTOWNHOUSE SASH WINDOW SASH WINDOW

YOUR GUIDE TO UNDERSTANDING CPR

Temperature Sensor TRG Original Installation Instructions English

Technical Bulletin CE marking: from 1st July 2013

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval.

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

European Technical ETA-07/0332 Assessment of 30 January 2015 General Part

Managing Fire Safety in your building: Fire Doors Inspections. Part of the KCC Architectural Group

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

IDD 033C - Fire door sets

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

Guide to Fire and Escape Doors: Part 1 - What are they? Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK

Guide to gate safety legislation and standards

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Standard Coverage, Model: RC-QR, K-Factor: 5.6, SIN: SS9561

European Technical Assessment. ETA-10/0255 of 22 August General Part. Technical Assessment Body issuing the European Technical Assessment:

Product. Regulations. Agrément Certificate No 92/2841 Third issue* Designated by Government to issue European Technical Approvals

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS

Construction Products Directive

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

Fire protection documentation. CFPA-E Guideline No 13:2015 F

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Contents EN :2006+A2:2016 (E)

Schueco Fire and Smoke Protection Systems

2.2 Factors in design

Slips: framing the issue

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED

European Technical Assessment. ETA-14/0269 of 13 October General Part. Technical Assessment Body issuing the European Technical Assessment:

BS EN ISO : 2010

European Technical Assessment

Record of Amendments. Version Date Amendment Section/page affected

Harmonisation and equivalence of reaction-to-fire performance classification in Europe: a small-scale desk-based study

WIND TURBINE DAMAGE PREVENTION

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5.

Guidance Note No 19/1. CE Marking windows and doorsets

dhf General Information Automated Gates Guidance for enforcement bodies

A Step by Step Guide to Energy Labelling of Gaseous Fuel Local Space Heaters (Part 1)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Specifying Security Hardware for Doors

HD72 Euro Profile Mortice Lockcase. The high performance lock that goes beyond the standard. ASSA ABLOY, the global leader in door opening solutions

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

New Requirements for Placing of Medical Devices on the Market: Conformity Assessment to the Technical Regulations

Introduction. Declaration of performance (DoP) CE marking

FIGURE 1. Model RD107

Panic & emergency exit devices. CFPA-E Guideline No 2:2013 F

COMMISSION DELEGATED REGULATION (EU) /... of XXX

Europacable FAQ on CPR Status: 26/01/17

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Standards in Security Shutters & Fire Shutters (UK & USA)

SENJU SPRINKLER CO., LTD.

European Technical Assessment. ETA-14/0475 of 19 December English translation prepared by DIBt - Original version in German language

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

fire resistance testing

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR)

BS EN ISO : 2010

Commercial Flat Concealed Sprinkler, Pendent, Quick & Standard Response, Standard Coverage, Model: CN-QR, K-Factor: 5.

Regulatory Reform (Fire Safety) Order 2005

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

Fire Door Maintenance Guide.

BUSINESS PLAN CEN/TC 10 LIFTS, ESCALATORS AND MOVING WALKS EXECUTIVE SUMMARY

Transcription:

Guide to interpreting Markings for Single Axis Fire Doors Hinges An overview of BS EN 1935: 2002: Building Hardware. Single Axis hinges as relates to Fire doors.

INTRODUCTION. It is a criminal offence to supply products that do not comply with the UK Construction Products Regulations. For fittings intended for use on fire, smoke and escape doors marking will be the easiest method to demonstrate compliance. The Building Control Officer or other approved inspectors or a Trading Standards Officer will require proof of this compliance. Across the UK construction industry and in Europe, construction products are being tested to the new EN Standards to ensure that fire, safety and performance requirements are met in future building projects. Door hardware will eventually have 21 new EN Standards. For many ironmongery items you will need to ensure that only marked products are used on all fire resisting, smoke control and escape doors. This summary only relates to single axis hinges, which are the most common means for hanging fire doors. The appropriate British Standard is BS EN 1935: 2002: Building Hardware Single Axis Hinges. The purpose of this submission is to enable interested persons to interpret the markings. If a greater understanding is required then it will be necessary to study the standard in depth. EXAMPLE OF CE MARKING FOR SINGLE AXIS HINGES * The manufacturer will state the precise field of application for fire/smoke door use according to B.2 of annex B of BS EN 1935. ** All or some of the digits may be substituted by NPD in the designation of products intended to be placed in markets where there are no legal requirements for self-closing or for any of the related characteristics.

EXAMPLE OF HINGE DESIGNATION For hinges for fire doors the hinge designation is very important. 1 2 3 4 5 6 7 8 2 7 3 0 1 1 1 10 This denotes a hinge for use in medium duty situations tested to 200,000 cycles, for use on doors with a mass up to 60 kg, with no stated fire resistance, mild corrosion resistance, suitable for use on burglar resistant doors, and with a hinge grading of 10. CODING SYSTEM For the purposes of this European Standard, hinges shall be classified according to the eight digit coding system described below. DIGIT 1 - CATEGORY OF USE. Grade 1 - Low frequency of use by people with a high incentive to exercise care and with a small chance of accidents occurring or of misuse. Grade 2 - Medium frequency of use by people with some incentive to exercise care but where there is some chance of accidents occurring or of misuse. Grade 3 - High frequency of use by public and others with little incentive to exercise care and with a high chance of accidents occurring or of misuse. Grade 4 - For use on doors which are subject to frequent violent usage. Grade 1 hinges should not be used on fire-resistant and/or smoke-control door assemblies. DIGIT 2 - DURABILITY/NUMBER OF TEST CYCLES Grade 1 : 2,500 cycles Grade 2 : 5,000 cycles Grade 3 : 10,000 cycles Grade 4 : 25,000 cycles Grade 5 : 50,000 cycles Grade 6 : 100,000 cycles Grade 7 : 200,000 cycles Grade 8 : 500,000 cycles Grade 9 : 1,000,000 cycles DIGIT 3 - TEST DOOR MASS Grade 1 : up to 20 kg Grade 2 : up to 40 kg Grade 3 : up to 60 kg Grade 4 : up to 80 kg

Grade 5 : up to 100 kg Grade 6 : up to 120 kg Grade 7 : up to 160 kg Grade 8 : up to 200 kg Grade 9 : up to 250 kg DIGIT 4 - FIRE BEHAVIOUR Grade 0: Not approved for use on fire/smoke resisting door assemblies. Grade 1: Suitable for use on fire/smoke resisting door assemblies, subject to satisfactory assessment of the hardware item relative to the performance of the specified fire/smoke resisting door assembly. No components of the hinge, except decorative parts, or its fastening shall have a melting point less than 800 C. (Steel) It does not apply to identical hinges that have been certified by passing the appropriate fire test for fire door sets. The following alternative grading system has been developed for fire resistance based on the fire resistance tests incorporated in BS EN 1634-1and will be included in two revised standards due for publication in 2006: EN 1125 and EN 179. Seven grades will be used: Grade 0: Not approved for use on fire/smoke door assemblies. Grade A: Suitable for use on smoke door assemblies - based solely on the requirements of the relevant product standard. Grade B: Suitable for use on smoke and fire door assemblies with a minimum classification time of 15 min. Grade C: Suitable for use on smoke and fire door assemblies with a minimum classification time of 30mins. Grade D: Suitable for use on smoke and fire door assemblies with a minimum classification time of 60mins. Grade E: Suitable for use on smoke and fire door assemblies with a minimum classification time of 90mins. Grade F: Suitable for use on smoke and fire door assemblies with a classification time of more than 90mins. DIGIT 5 - SAFETY IN USE Grade 0: No defined safety performance Grade 1: Satisfies the safety in use requirements contained in the Construction Products Directive issued by the EU. DIGIT 6 - CORROSION RESISTANCE Five corrosion grades are identified in accordance with BS EN1670: Grade 0 - No defined corrosion resistance Grade 1 - Mild resistance Grade 2 - Moderate resistance

Grade 3 - High resistance Grade 4 - Very high resistance. DIGIT 7 - SECURITY - BURGLAR-RÉSISTANCE Two grades of security are identified for hinges manufactured to this European Standard. Grade 0: not suitable for use on burglar-resistant door assemblies; Grade I: suitable for use on burglar-resistant door assemblies, subject to satisfactory assessment of the contribution of the hinges to the burglar resistance of specified burglar-resistant door assemblies. Such assessment is beyond the scope of this European Standard. DIGIT 8 - HINGE GRADE Fourteen grades of hinge are identified in this European Standard, as listed in Table 1 Table 1 Classification Summary First Second Third Fourth Fifth Sixth Seventh Eight Category of use Durability test Cycles Test door mass Fire/smoke suitability Safety Corrosion resistance Security Hinge grade Duty Grade For use Grade Number Grade Mass Grades Grades Grades Grades Grades on of test cycles Available Available Available Available Light 1 Window 3 10 000 0 10 0 or 1 1 0,1,2,3,4 0 or 1 1 Light 1 Window 3 10 000 1 20 0 or 1 1 0,1,2,3,4 0 or 1 2 Light 1 Door or 4 25 000 1 20 0 or 1 1 0,1,2,3,4 0 or 1 3 Window Medium 2 Door 7 200 000 1 20 0 or 1 1 0,1,2,3,4 0 or 1 4 Light 1 Window 3 10 000 2 40 0 or 1 1 0,1,2,3,4 0 or 1 5 Light 1 Door or 4 25 000 2 40 0 or 1 1 0,1,2,3,4 0 or 1 6 Window Medium 2 Door 7 200 000 2 40 0 or 1 1 0,1,2,3,4 0 or 1 7 Light 1 Window 3 10 000 3 60 0 or 1 1 0,1,2,3,4 0 or 1 8 Light 1 Door or 4 25 000 3 60 0 or 1 I 0,1,2,3,4 0 or 1 9 Window Medium 2 Door 7 200 000 3 60 0 or 1 1 0,1,2,3,4 0 or 1 10 Heavy 3 Door 7 200 000 4 80 0 or 1 1 0,1,2,3,4 0 or 1 11 Severe 4 Door 7 200 000 5 100 0 or 1 1 0,1,2,3,4 0 or 1 12 Severe 4 Door 7 200 000 6 120 0 or 1 1 0,1,2,3,4 0 or 1 13 Severe 4 Door 7 200 000 7 160 0 or 1 1 0,1,2,3,4 0 or 1 14 Additional requirements for hinges intended for use on fire doors. It shall not be possible to remove the hinge pin or separate the hinge element of the door assembly without the use of special tools Hinges interrupt the leaf edge and frame gap, and their fastenings penetrate the leaf. The influence that this may have on the smoke-control properties of an assembly can only be determined by subjecting a full-sized assembly fitted with the hinges to the appropriate fire test.

Hinges for doors fitted with door closers Door closers increase the loading on door hinges and their rate of wear. For closers without back-check it is normal to allow for this by assuming the effective door mass to be 20 % greater than the actual door mass. For back-check closers the effect is much greater, and the effective door mass is calculated to be 75 % greater. Timber doors fitted with door closers should normally use three or more hinges. Door manufacturers may recommend the use of only two hinges under special conditions, if experience allows demonstrating adequate performance of the door. Door closers which include hold-open devices or a back-check facility can impose substantially increased stresses on hinges and their fastenings. Hinges of grade 12, 13 or 14 should be used with such closers. If three hinges are used the third hinge should be fitted approximately 200 mm below the top hinge, in which position it supports some of the additional outward bending moment exerted on the top hinge. Substantial fastenings are recommended for both hinges and closers in such situations to prevent loosening of the fastenings and possible damage to the door or frame as a consequence of such loosening. The maximum closing torque that can be exerted by a door closer is limited and varies according the size and the mounting mode of the door closer. For this reason it is important that hinges used with doors fitted with door closers should not generate excessive frictional torque. It is recommended that the maximum in-service torque for a set of two, three or more hinges when installed on such doors should be 3 Nm for grades 1 to 7, 4 Nm for grades 8 to 11, and 5 Nm for grades 12 to 14. Hinges for such applications should be carefully selected.