/ Marley Collection Basin Heater / User Manual

Similar documents
Marley Collection Basin Heater Circuit

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Fluid Cooler Fan and Pump control panel

ABH basin heater control

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

SAFETY INFORMATION AND WARNINGS

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Check that connection to main board is clean and sound at J8

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

vibration switch

MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Norcold Repair Guide for Ice Maker

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

Cedarbrook Sauna + Steam Family owned and operated since 1971

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

SpeedClave Steam Sterilizers

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Heat Pump Defrost Board Replacement Kit

Ice*Meister Model 9734-SYSTEM INDUSTRIAL ICE DETECTING SENSOR SYSTEM Technical Data Sheet

Installer Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Service Handbook. Servicing should only be performed by a Qualified Service Agent.

QuadraFlow Cooling Tower

Public Safety DAS Annunciator Panel

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

MICROPROCESSOR RAPPER CONTROL MODEL MRC-NT

ADD FLUID 300 NDNL 300 CT 300 OC 700 NDNL 725 NDNL 950 NDNL

21-light Remote Annunciator. Owner s Manual

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

DISCONTINUED VERSION The information in this manual is no longer current.

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

SAFETY INFORMATION AND WARNINGS

Warranty Info: ETI s warranty policy can be viewed at:

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TX / HX TANKLESS WATER HEATER

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

STEAMPRO. Steam Generator Troubleshooting and Service Guide

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Air Conditioning Operation and Troubleshooting Matt Dunham

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

System Control. Installation, Operation & Service Manual WARNING. Installer

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

R Series B & T2 Model

Service Manual Model 3163

Technical

Evaporative Cooling Equipment Installer / Contractor Pre Start-Up Checklist

Pump-Down Controller MODEL 4052

Product Manual SZ1145

5. CBS Alarms Responding to a CBS Alarm Understanding the Alarm Condition A-CBS-008 Circuit Breaker Sentinel Page 109 of 156

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

Model 3300 Technical Support and Installation Manual

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

Downtime Instructions

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

Troubleshooting Guide For FG3000 Dual Medium Intensity Lighting System

Emerson Blue Easy Set 1H/1C

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

HT-2 / 9600 Series Control Contents

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

OPERATING INSTRUCTIONS MANUAL FLE-150 INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Type 750HT Flux Rebaking Ovens

Product Manual SZ1144

Tower Ceramic Heater

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

Serial-No. / date. Electric: / May 2007

CH750, CH751 & CH951 CHILLERS

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

K00364 Electronic Bin Thermostat

Duct and Rough Service Carbon Monoxide Sensor

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

EATON DFDAP-M / FDAP-M Remote Alarm Panels

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Pioneer-R16 Gas Monitor Operator s Manual

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Installation Guide for models:

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Transcription:

/ Marley Collection Basin Heater / User Manual 98-1483

Introduction This manual covers operation and maintenance of Indeeco heater control systems for cold water basin heaters when included in Marley Basic Control Systems for fan motors. This system includes an Indeeco Series 550 circuit board relay, a duel function sensor, contactor and fuses sized for the basin heater elements required. Operation To operate the heater, check the water level and verify the sensor is submerged in water. See Figure 1. The system will not energize until both the water level and the temperature conditions are met. The water level must be above the sensor and the temperature must be below the set point. This set point is fixed at 45 F. Turn power on. If the green LED on the circuit board is on this indicates that the water temperature is below the set point and the heater is ON. If no LEDs are illuminated this indicates that the water temperature is above the set point and the system is operational. If the red LED is illuminated this indicates that the water level is below the probe. The fan motor starter is interlocked with the heater controls and the fan will not run when the heater is ON. There is no separate switch for the heater control. The heater is operational whenever the control panel disconnect is in the ON position. To service the basin heaters it is necessary to place the disconnect in the OFF position. To disable the operation of the basin heater, remove the basin heater fuses. The circuit board and contactor will remain operational. However, no heating will occur with the heater fuses removed. Figure 1 SOLID STATE RELAY CARD Red Green OFF OFF Ready, No Demand ON OFF Low Water Level N 120 24 240 CT COM NC NO GREEN SH T1 T2 G1 G2 SHIELD PROBE OFF ON Heater On LED INDICATORS BASIN 3

Operation Testing above Freezing Temperatures Under normal operating conditions the heaters will be turned on at a water temperature between 40 and 45 F, and turned off when the water temperature exceeds 45 F. For testing the system at temperatures above 45 F use the following method 1. Disconnect power to the control panel using standard lockout procedure. 2. Remove the sensor wires connected to terminals T1 and T2 on the relay circuit board. 3. Connect a 1.5K ohm resistor across T1 and T2 terminals see Figure 2. 4. Close panel door and verify probe is submerged in tower basin water. Figure 2 SOLID STATE RELAY CARD N 120 24 240 CT COM NC NO GREEN G2 G1 T2 T1 SH SHIELD PROBE RESISTOR BASIN 5. With panel door closed turn on power supply to the system. An audible CLICK should be heard as the contactor engages. If this does not happen, refer to the Troubleshooting section of this manual. 6. If the system tests OK turn off power, open panel, and remove the resistor. Replace sensor wires T1 and T2 and close door. Turn power on. 4

Operation Deicing If the sensor becomes encased in solid ice the heaters will not operate. Ice provides inadequate conductivity for the sensor probe to detect operational water level. To operate heaters in this situation and melt the ice follow these procedures. 1. Disconnect power to the control panel using standard lockout procedures. 2. Install a jumper wire between relay terminals G1 and G2 see Figure 3. Figure 3 SOLID STATE RELAY CARD JUMPER N 120 24 240 CT COM NC NO GREEN SH T1 T2 G1 G2 SHIELD PROBE BASIN 3. Close panel door. 4. Energize the system and listen for contactor closing. 5. Operate the system until ice is melted around the sensor probe. 6. After ice is melted, de-energize the system, remove the jumper, check all connections and place the system back in operation. Caution Do not leave the heating system unattended during this procedure. There is no low water protection with this jumper in place. 5

Troubleshooting If the system fails to operate, check the following: 1. Check water temperature. Systems will turn on between 40 and 45 F and turn off above 45 F. 2. Check water level. Water must completely cover the sensor probe. 3. Make sure sensor is not encased in ice. See Deicing procedure. Caution The following checks should be made by a qualified electrician. 4. Open the panel and check incoming electrical power for proper voltage. Make sure all phases are present. Correct as required. 5. If water level is adequate, temperature is 40 F or lower and power is present, observe the LEDs on the relay circuit board. The red LED indicates low water level or ice around the probe and the green LED indicates the heaters are energized. a. If the red LED is on and the sensor probe is submerged in water no ice this indicates the sensor probe is defective. Confirm by disconnecting power and placing a jumper across terminals G1 and G2 see Figure 3. Reconnect power. If the red LED is now off and the green LED is on, the system is now operating. Replace sensor probe. b. If the green LED is on and the heaters are not operating the problem is either the contactor, the relay circuit board or the heater elements. To determine which, observe the panel while power is disconnected and reconnected. If the contactor operates with an audible CLICK and no heat results the heater element is defective. Check voltage at the heater side of the contactor to confirm voltage is present. Check each line with a clamp-on amp meter. If voltage is present and no current is flowing, this indicates the element is defective and must be replaced. As an additional check, disconnect power, remove wires from the contactor and check the element with an ohm meter for measurable resistance. c. If the green LED is off and the red LED is also off the problem is either the circuit board or the sensor probe. To determine which, disconnect power and remove wires T1 and T2 from the circuit board. Replace with a 1.5K ohm resistor see Figure 2. If the heater now works the sensor probe is defective and must be replaced. If the heater does not work the circuit board is defective. 6

Troubleshooting 6. The sensor assembly can be checked for accuracy in the following manner. a. Remove wires T1 and T2 from the circuit board and measure ohm readings across these wires. Measure temperature that the probe is being exposed to. Compare with the following values. Temp F ohms 0 4273 10 3126 20 2312 32 1633 40 1305 45 1138 60 765 75 525 85 412 Parts List Replacement Parts Control Card...C00640D 12-0 Probe Cord Assembly...A81137D For complete parts and service assistance, contact the Marley sales representative in your area. If you need help locating the office nearest you, please phone 913 664 7400 or check the internet at spxcooling.com. 7

7401 WEST 129 STREET OVERLAND PARK, KANSAS 66213 UNITED STATES 913 664 7400 spxcooling@spx.com spxcooling.com In the interest of technological progress, all products are subject to design and/or material change without notice. 2010 SPX Cooling Technologies, Inc. Printed in USA Manual 98-1483