CE818. User Manual. Made in Italy M1.5.1-H2.0-F1.41-S1.41-ENG

Similar documents
Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Ref.1067/032 Ref.1067/042

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

BURGLAR ALARM PANEL BS-468

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

3 User s settings. 3.3 Internal clock setting

JA-63 Profi User manual

Security System. User s Guide for the Text Command Center

Watchguard WGAP864 User Manual

Wireless Keypad GKP-S8M

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

AXI LED USER MANUAL (REV. 1.0)

Installation Manual Premier 412/816/832. Issue 10

Contents. Glossary

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Control/Communicator Installation Manual

Security System. User Guide for the LED Command Center

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

Security GSM Alarm System

Fire Command Keypad. XR5 User s Guide

Table of Contents. Appendix A Special Characters 31

Wireless Keypads LKP(E)S8M Series

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Summit 3208GLD USER MANUAL. Electronics Line

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Instructions manual. By-alarm. By-alarm Manager software

BURGLAR ALARM PANEL BS-468/A

User Manual (LS-GSM-006)

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Burglar-alarm unit. User manual. Part. U3499A - 11/08-01 PC

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

SCORPION Z16040C, Z8040C and Z5120C

MOBILE CALL GSM Alarm System User s Manual

D3D Wi-Fi GSM Smart Alarm System -User Manual

U ser's Guide PC6010

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

DESCRIPTION OF KEYPAD (Access module with segments)

EasyLoader. End User Manual

ELT-KLED EliteSuite LED Keypad Installation Manual

Destiny Destiny Owners Manual

Quick Reference Guide

1. Introduction. 2. Product overview

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

XRSuper6. User s Guide

"Pegaso" wireless alarm system D.I.Y. wireless kit

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

"Pegaso" wireless alarm system

Solution 880 Operators Manual. Issue 1.00

Solution Ultima Series Operators Manual ISSUE 1.00

ITI Caretaker Basic Commands

SA 2650 Kit User Manual

GSM LCD Touch Keypad Wireless Intelligent Alarm System. User s manual

Solution 844 Operators Manual ISSUE 1.10

IDS816 User Manual H Issued January 2009

Intelligent Wireless GSM Alarm System

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

CA60Plus. Installation manual

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

L900 series USER MANUAL

Contents. Contents

Touch Keypad GSM Smart Alarm System USER MANUAL

User s Information Guide R2A

Fusion Alarm System USER GUIDE

DS7400Xi (version 3+) Security System User s Guide

Master User Guide Premier Elite Series

PROGRAMMING PROCEDURES (Table 3)

Solution Ultima 862 Operators Manual ISSUE 1.10

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Training Manual with Bi-directional Wireless

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

Intruder alarm panel Terxon MX Operating instructions

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

NX-148 LCD CODE PAD TABLE OF CONTENTS

System Introduction. 1.1 Specifications

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

Series. NX-4-EUR Control Panel. Installation manual

System. For a better understanding of this product, please read this user manual thoroughly before using it.

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Using Your. Security System With LED Keypad S5030, S5031, S5032

VAP304 PRO INSTALLATION & OPERATION MANUAL

EC-P Zone Intruder Alarm System

RE6100 Series Helix Security and Automation Platform

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

Version 1.03 January-2002 USER S MANUAL

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

TABLE OF CONTENTS TABLE OF CONTENTS 1

ADVISOR CD User Manual. Software from version: V

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

HMS MODEL 800 Owner s Manual

Transcription:

CE818 User Manual 14.07-M1.5.1-H2.0-F1.41-S1.41-ENG Made in Italy 1

FEATURES OF YOUR SECURITY SYSTEM The core of your security system is the CE818 control panel, an intelligent microprocessor device that oversees the safety of persons and your home. The control panel manage up to 16 zones protect by sensors and contacts, and receives commands from LCD keyboards (Advanced mode) and electronic key readers. The system can be activated in different modes (depending on the working mode); for example, during night, you can activate the protection only on living room or on the perimeter of your house, having the possibility to freely move inside at system activated. It is possible to add a GSM or PSTN communicator (optional) to provide you an intelligent remote alarm signalling. In case of alarm, the phone communicator will inform you with a vocal message or SMS, allowing you even when you are away to monitor in real time what happens in your home. From landline or mobile phone you can verify the status of your panel and the whole system or send a command to the system. WORKING MODE The control panel can work in two modes: Base Mode Advanced Mode Depending on the selected mode, the control panel can be equipped with accessories and functions. Verify in which mode your control panel is working. It is possible to select the working mode to favour both installer and user: the base system is expandable at any time just restarting the control panel in advanced mode adding peripherals, zones, functions 2

SYSTEM DEVICES CE818 Electronic Control Panel DVT-LCD / DVT-OLED LCD/OLED wired keyboard LET-485 Wired electronic keys reader CHT Transponder electronic key ASIG / ASC / ABASC Wired magnetic contacts DIRF, DIRRPV, DDT-S Single and double technology indoor sensors E-Wall, DIRFE, barriers, MOSKITO-F Outdoor wired sensors and barriers PEPEROSSO Wired dissuader DVSIR, DVSIR-PROX, DVPZ Wired sirens 3

GLOSSARY Alert Power Fail Beep Boop Buzzer Electornic Key Remote Code User Code Coercion PSTN Dialler GSM Dialler Exclusion/bypass Function for generate a din-don tone from keyboards and key readers AT SYSTEM DISARMED when selected zones are violated If the 230 VAC power line fall down for a long time (programmable timing), the control panel will advice and activate a dedicated output (automatic restore when power line backs up). Useful for example to activate a phone call in case of black out Word to indicate a treble sound emitted by keyboard or key reader each time a button is pressed, you interact with the system or to signal an event As per Beep, this word indicates a bass sound emitted by keyboard or key reader in particular circumstances Sound generator inside keyboards and key readers Electronic key with digital security code enabled to activate/deactivate the control panel. Must be used with the key reader (only if connected the GSM dialler and/or the PSTN module) Four digit security code for use of GSM/PSTN commands and functions. This code must be inserted in each command sent to the dialler. Six digit code used to access to alarm system using the keyboard This function allow to obtain a silent alarm signalling in case you are forced to disarm the system under menace. It is possible to use this function in two modes: after the disarming of the system do NOT press any directional key on DVT-LCD/OLED keyboard within programmed time press a dedicated button connected by wire to one of the input of the control panel Device optional to send vocal messages via landline connection. In this control panel this device is an additional module installed onboard Additional external device (optional) to send vocal and SMS messages using the GSM network service. The connection with the control panel is realized on BUS 485 (mod. GSM BUS) Function that allow the user to exclude the wanted zones so to bypass them at system armed Arming / Disarming Action of the user to activate/deactivate the alarm system. At system armed the violation of a zone generates alarm. At system disarmed the violation of the zones does not generate alarm. LED Key Reader Lights, for different signallings, on keyboards and key readers These devices read the transponder electronic keys 4

User Menu Monitor (zone) (only in ADVANCED mode) Special menu with control panel options, only for Master users. In this menu it is possible, for example, to set date and time, manage other users, bypass zones, etc. A zone sets as MONITOR, when violated, cause only the buzzer sound on keyboards and key readers (not sirens) for 30 seconds. Function useful for example in case you want to protect an external area, and just be warned when you are at home. Panic (wired) Press a dedicated button to start the siren sound for a fixed time of 30 seconds, in order to draw attention. The panic vocal call and SMS are send (if enabled). Partialization BUS device PreAlarm Sensor Sounds LCD / OLED keyboard Entry Time Exit Time Output Special arming mode of control panel, it exclude a group of zones. In this way a part of the protected area will not be monitored by the system and it will be possible to move inside this area without alarm even if the system is armed Device connected to control panel by a 4 wires cable (BUS RS485) (usually keyboards, key readers and expansion boards) Only for PARTIAL armings. At the start of alarm, the siren sounds at low level for a programmed time and then continue at high level. During the pre-alarm no SMS or vocal call are sent. Device for violation detection with different technologies (glass breaking, intrusion, door opening, ecc.) On keyboards some sounds are disabled with variable time when the user or installer make some operation: simple operations sounds disabled for about 30 seconds programming or event queue sounds disabled for 10 minutes The disabled sounds are: entry and exit sounds pre-alarm monitor and technologic maintenance Keyboard provided with display LCD / OLED, buttons and LEDs and with which the user/installer interact with the alarm system. The keyboard allows the control panel programming. It is possible to program some zone when violated to cause siren sound only after a certain time. Useful for example if the control panel is far from entry door and it is necessary to go near to it to disarm the system. It is possible to set a time that allow to arm the system and exit from the building without generate alarm. There are four outputs on control panel, which are activated according to some combined event (ex.: to switch on a lamp in case of alarm or to activate a phone dialler) BASE mode: the outputs are pre-programmed 5

Guest User Master User Patrol User Zone Technologic Zone ADVANCED mode: it is possible to customize the events that activate each outputs (for a complete list ask to your installer). Guest users can arm and disarm the system only if enabled by a Master user. Master users have high privileges on the system (except for installation and system configuration changes). Master users actions: arm (any mode) and disarm the system access to User menu add, delete and change other user settings make system tests Patrol users cannot arm or disarm the system but at system armed bypass for a certain time the zones set for this behavior. This function is useful for example to allow the access only in certain areas, without disarm the system (service staff). A zone manage all the sensors connected to it. The zone corresponds, usually, to a protected area of the building, a local or simply to a single sensor A zone set as TECHNOLOGIC is active 24 hours / 24, so it is NOT subject to arming or disarming of the system. In case of detection, the zone cause an alarm with low level siren sounding. Function useful for example in case of flood-sensors, smoke-sensors, gassensors, and so on Example: it is possible to have immediate signalling of a gas leakage and drive an electric valve (using one of the outputs) to block the gas flux and avoid the danger. 6

KEYBOARD THE KEYBOARD CAN BE USED ONLY WITH CONTROL PANEL IN ADVANCED MODE Follows the description of buttons and functions of the keyboard: Backlit display Arming buttons / Sysem status Directional buttons Alphanumeric buttons Button * / ALERT status Button # / DISARM OK button CANCEL button The keyboard allow to control your alarm system: visualize the system status, functions and other alerts arm and disarm user management visualize system events and alarms ALWAYS CHECK ON DISPLAY YOUR CORRECT OPERATING 7

KEYBOARD USERS (ONLY ADVANCED MODE) The control panel manage up to 16 users Each user can be set as: o MASTER Master user can arm and disarm the control panel without limitations. It has access to User menu to change other users, bypass zones, change date and time and perform a system test. o PATROL At system armed, the Patrol user can bypass some zone (all the ones set as Patrol) to access in wanted areas without cause alarm. The control panel stays armed, so if the user violates a zone not set as Patrol (R), the control panel will detect alarm. When leaving, the Patrol user can include again the bypassed zones, or it is possible to set an auto-rehabilitation time. Patrol user has no access to User menu. o GUEST Guest user has limited access and can only arm according to Master user and Installer permits. The Guest user can disarm the control panel only if enabled. Guest user has no access to User menu. Each user has a six digits code (changeable) to arm and disarm the system Each user can have a combined electronic key (see next paragraph) It is possible to enable an SMS/vocal message each time each user act on the system 8

ELECTRONIC KEYS AND KEY READER The electronic keys are read by key readers. With the keys it is only possible to arm and disarm the system. Key reader Electronic key Multicolour LED BASE mode Each key stored is an user. The control panel can store up to 12 electronic keys. All the keys have the same privileges, can arm in Total, Partial and Disarm the system ADVANCED mode At each user can be combined one electronic key (up to 16 users) If the user is set as MASTER, its key will arm and disarm without restrictions. If the user is set as GUEST, the key arm and disarm the system according to the privileges allowed by the Master user. If the user is set as PATROL, the key bypasses/rehabilitates the Patrol zones. 9

BASE MODE 10

BASE mode 8 wired zones Max 12 electronic keys to arm the system Small system (max 8 wired zones) but with all essential functions Max 4 key readers Two arming modes: Total and Partial Alarm system upgradeable without change the control panel Communication via GSM (optional) Zones 8 on-board zones (not expandeable) Zone 1: with entry time Zones 2 8: instantaneous Exit time 30 (+ 30 in case of opened doors) Fixed Entry time 30 Fixed Alarm time 120 Fixed Alarm cycles From same zone: 4 Fixed In same arming cycle: 10 Fixed Vocal calls 1 for each telephone number Only alarm call (if GSM-BUS installed) Arming modes Total Included zones: from 1 to 8 Partial Included zones: from 1 to 5 (not 6, 7, 8) Electronic keys (CHT) Max 12 * BUS 485 devices LET-485 Max 4 GSM-BUS Max 1 Outputs Output 1 Total armed Output 2 Partial armed Output 3 TC Output 4 Low battery buzzer (active until battery restore) Battery 12 V / 7,5 Ah * Only the installer can add/delete electronic keys 11

ARMING / DISARMING TOTAL ARMING To arm the system in TOTAL mode, pass once a CHT key over a key reader. A confirming beep is emitted and the RED LED lights solid on key reader. A beep series for about 30 seconds (exit time) are emitted, then the system is armed. TOTAL arming Active zones Sound alerts LED on LET-485 Control panel outputs GSM alerts * All (zone 1 zone 8) The zone 1 is Delayed (Entry time = 30 s) One beep to confirm arming A beep series during Exit time (30 s) RED, solid on Output 1 ( Total armed ) changes status Output 3 ( TC ) changes status SMS for Total armed to enabled numbers * If GSM module installed PARTIAL ARMING To arm the system in PARTIAL mode, pass twice a CHT key over a key reader. A confirming beep is emitted and the GREEN LED lights solid on key reader. To arm it is also possible to hold the key over the key reader until the GREEN LED lights on (corresponding to Partial arming) then remove it. A beep series for about 30 seconds (exit time) are emitted, then the system is armed. PARTIAL arming Active zones Sound alerts LED on LET-485 Control panel outputs GSM alerts * Only zones 1 5 Zones 6 8 are disabled The zone 1 is Delayed (Entry time = 30 s) One beep to confirm arming A beep series during Exit time (30 s) GREEN, solid on Output 2 ( Partial arming ) changes status Output 3 ( TC ) changes status SMS for Partial armed to enabled numbers * If GSM module installed 12

OPENED DOORS (ZONES) If the system is armed with one or more opened zones, a quick beep serie is emitted. After 30 seconds of this opened zones signalling in addiction to the 30 seconds of exit time, the control panel will arm normally but the opened zones will be temporary bypassed. If these bypassed zones are then closed at system armed, they will be activated: at this point they will generate alarm if violated. DISARMING (WITHOUT ALARM) To disarm the system, pass once a CHT key over a key reader. A confirming beep is emitted and the LED switch off on key reader. DISARMING Zones All the zones are disabled One beep to confirm disarming Sound alerts In case entering by zone 1 before disarm, a beep series signals the Entry time (30 s) LED on LET-485 OFF * Control panel Output 1 or 2 (arming type) changes status outputs Output 3 ( TC ) changes status GSM alerts ** SMS for Disarmed to enabled numbers * If no alarm event during arming ** If GSM module installed DISARMING (WITH ALARM) In case of alarm, disarm as descrived above. The siren stops sounding and all the alerts via GSM/PSTN are interrupted (SMS or calls if GSM/PSTN module installed). The LED on key readers will blink RED as many times as the last violated zone number. The blinking is repeated after a pause of 3 seconds, for the whole duration of alarm memory (about 1 minute). To read the Event log, download it from control panel on a USB memory (option for installer). 13

KEY READERS FEEDBACK When control panel is on and disarmed the LED on key reader is normally OFF. The LED lights on to signals events: LED OFF ON BLINKING Red Disarmed / Off TOTAL armed Alarm memory, number of last violated zone (at disarming, for 60 seconds) Green Disarmed / Off PARTIAL armed - Multicolour - - Not possible to communicate with control panel 14

ADVANCED MODE 15

ADVANCED mode 8 onboard wired zones + 8 wired zones on expansion board + 1 zone on each DVT-LCD/OLED keyboard Max 16 electronic keys Max 16 keyboard users Max 4 LCD/OLED keyboards Max 4 key readers System with advanced functions Medium/large alarm system (max 16 wired zones) Three arming types (customizable): Total, Partial 1 and Partial 2 Auto-arming and Patrol GSM communication (optional) USB/software programming Zones: on-board 8 zones Zone 1 (IN1): with entry time * Zones 2 8 (IN2 IN8): instantaneous * Zones: on expansion board 8 zones Exit time 30 (+ 30 in case of opened doors) * Changeable Entry time 30 * Changeable Alarm time 120 * Changeable Alarm cycles From same zone: 4 Fixed In same arming cycle: 10 Fixed Vocal calls 1 for each telephone number * Only alarm call (if GSM-BUS/PSTN installed) Arming modes Total Included zones: from 1 to 8 * Partial 1 Included zones: from 1 to 5 (not 6, 7, 8) * Partial 2 No zones active * Opened Doors advice Blinking of GREEN LED on LET-485 Electronic keys (CHT) Max 16 BUS 485 devices LET-485 Max 4 DVT-LCD Max 4 GSM-BUS Max 1 ESP8-2 / ESP8-BUS Max 1 Outputs Output 1 (open collector) Armed: positive at system armed (+INS) * Output 2 (open collector) Armed: positive at system disarmed (TC) * Output 3 (open collector) Technologic (output switch for 60 ) * Output 4 (open collector) Silen Alarm (output switch for 5 ) * Battery 12 V / 7,5 Ah * Factory settings, changeable via Installer menu or software 16

ARM / DISARM By factory setting, the User 1 code is enabled as MASTER type and code 100000 TOTAL ARMING To arm the system in TOTAL: With User Code With Electronic Key 1. Press the F1 button 1. Pass once a CHT key over a key reader 1x 2. Digit the User Code (factory: 100000 ) 3. A beep confirms arming, the RED LED on key reader and F1 button on keyboard switch on 4. A beep series for about 30 seconds (exit time) are emitted, after that the system is active 2. A beep confirms arming, the RED LED on key reader and F1 button on keyboard switch on 3. A beep series for about 30 seconds (exit time) are emitted, after that the system is active TOTAL arming Active zones * Sound alerts Visual alerts Control p. outputs * GSM alerts ** All the zones enabled in Total mode but bypassed zones by the user (User menu only if Master) Factory: All the zones are enabled The zone 1 has Delay (Entry time = 30 seconds) One beep to confirm arming A beep series during Exit time (30 s) Key reader: RED LED, solid on Keyboard: F1 button solid on Output 1 ( +INS ) changes status Output 2 ( TC ) changes status SMS for Total arming to enabled numbers * It is possible to change the settings by Installer menu or software ** If GSM module installed 17

PARTIAL 1 ARMING By factory setting, the user 1 code is enabled as MASTER type and code 100000 To arm the system in PARTIAL 1: With User Code With Electronic Key 1. Press the F2 button 1. Pass twice a CHT key over a key reader 2x 2. Digit the User Code (factory: 100000 ) To arm, it is also possible to hold the key over the key reader until the GREEN LED lights on (corresponding to the Partial 1 arming) then remove it. 3. A beep confirms arming, the GREEN LED on key reader and F2 button on keyboard switch on 4. A beep series for about 30 seconds (exit time) are emitted, after that the system is active 2. A beep confirms arming, the GREEN LED on key reader and F2 button on keyboard switch on 3. A beep series for about 30 seconds (exit time) are emitted, after that the system is active PARTIAL 1 arming Active zones * Sound alerts Visual alerts Control p. outputs * GSM alerts ** All the zones enabled in Partial 1 mode but bypassed zones by the user (User menu only if Master) Factory: Enabled only zones 1 5, zones 6 8 are disabled The zone 1 has Delay (Entry time = 30 seconds) One beep to confirm arming A beep series during Exit time (30 s) Key reader: GREEN LED, solid on Keyboard: F2 button solid on Output 1 ( +INS ) changes status Output 2 ( TC ) changes status SMS for Partial 1 arming to enabled numbers * It is possible to change the settings by Installer menu or software ** If GSM module installed 18

PARTIAL 2 ARMING By factory setting, the user 1 code is enabled as MASTER type and code 100000 To arm the system in PARTIAL 2: With User Code With Electronic Key 1. Press the F3 button 1. Pass three times a CHT key over a key reader 3x 2. Digit the User Code (factory: 100000 ) To arm, it is also possible to hold the key over the key reader until the BLUE LED lights on (corresponding to the Partial 2 arming) then remove it. 3. A beep confirms arming, the BLUE LED on key reader and F3 button on keyboard switch on 4. A beep series for about 30 seconds (exit time) are emitted, after that the system is active 2. A beep confirms arming, the BLUE LED on key reader and F3 button on keyboard switch on 3. A beep series for about 30 seconds (exit time) are emitted, after that the system is active PARTIAL 2 arming Active zones * Sound alerts Visual alerts Control p. outputs * GSM alerts ** All the zones enabled in Partial 2 mode but bypassed zones by the user (User menu only if Master) Factory: No zones enabled One beep to confirm arming A beep series during Exit time (30 s) Key reader: BLUE LED, solid on Keyboard: F3 button solid on Output 1 ( +INS ) changes status Output 2 ( TC ) changes status SMS for Partial 2 arming to enabled numbers * It is possible to change the settings by Installer menu or software ** If GSM module installed 19

DISARMING (WITHOUT ALARM) With User Code With Electronic Key 1. Press the # button 1. Pass once a CHT key over a key reader 1x 2. Digit the User Code (factory: 100000 ) 3. A beep confirms arming, the LED on key reader switch off and the # button on keyboard switch on 2. A beep confirms arming, the LED on key reader switch off and the # button on keyboard switch on Disarming Zones Sound alerts Visual alerts Control p. outputs * GSM alerts ** All the zones are disabled Technologic zones stay always One beep to confirm disarming In case entering by a delayed zone before disarm, a beep series signals the Entry time (30 seconds) Key reader: LED off Keyboard: # button solid on Output 1 ( +INS ) changes status Output 2 ( TC ) changes status SMS for Dsiarming to enabled numbers * If no alarm during the last arming ** If GSM module installed DISARMING (WITH ALARM) In case of alarm, disarm as descrived above. The siren stops sounding and all the alerts via GSM are interrupted (SMS or calls if GSM module installed). The LED on key readers will blink RED for about 1 minute to advice the alarm memory. To read the Event log, download it from control panel on a USB memory (option for installer). 20

ERROR DURING DIGIT (FALSE CODE) The control panel checks is there are three errors during code digiting on keyboard. After the 3 rd error: the keyboards are blocked for 2 minutes and on display appears Keyb. Block a False Code SMS is sent and starts a Theft vocal call (more details on dialler manual) In case of two errors, 15 minutes are required to reset the false code error count. OPENED DOORS If this (control panel) function is enabled, when a door or window remain opened, the keyboard alerts by blinking the button (red). If with an opened door you try to arm the system, the control panel will alert with a quick beep series. At this point, it is possible to: press the button: it is displayed a list of opened doors/windows (scroll the list with the button). Press again the button to abort the arming and then close the doors/windows. Press the button: the control panel will arm. The opened doors will give immediate alarm if the Alarm option is enabled, no alarm if the Bypass option is enabled ( Door Control section). 21

Alert To enable or disable the Alert signalling, follow next steps: 1. At control panel disarmed, press the button: the user code. is required: 12:32 01/06/10 Disarmed User Code ------ 2. Digit the user code followed by. 0 9 Digit the User Code User Code ****** Confirm the change between on/off of the Alert Cancel the operation 3. Alert is enabled/disabled. The Alert status (on/off) is shown by the blue button on keyboard. BUTTON (BLUE) = ON ALERT ENABLED BUTTON (BLUE) = OFF ALERT DISABLED 22

USER MENU Only the Master users can enter the User Menu. To enter in User Menu: 1. Make a disarm of the system (even if it is already disarmed) 2. Press 3. Digit the User code (factory: 100000) 4. Press Use the arrow keys () to move along the menu options, the button to enter and/or confirm a choice, the button to cancel and/or delete. PSTN Remote Code Date and Time Exclusions User Progr. System Test Outputs Test PSTN REMOTE CODE Change the Remote Code. For PSTN communication (for GSM Remote Code, see COMBY GSM BUS manual) Factory: 100000 Remote Code 1 0 0 0 0 0 DATE AND TIME Change the date and time of the control panel. After the change, confirm by pressing. 23

EXCLUSIONS Bypass the selected zones at next arming. After each selection press to confirm. Exclusions Zone xx Select the zone to bypass with the keys Press to bypass the zone: on display appears a X Press to include a bypassed zone USER PROGRAMMING Set the users on control panel. Max 16 users. User name User 01 16 Change the name using the alphanumeric buttons User 01 By factory, the User 01 is active and set as Master, with code 100000 User type Master Patrol Guest Master user can arm and disarm the system without limitations. It has access to User menu to change other user settings, zone bypass, date and time and system test. At system armed, the Patrol user can bypass zone set as Patrol, and thus access to selected areas without generate alarm. The panel is not disarmed, so if user violates zones different from Patrol type the panel starts alarm. At exit the Patrol user can re-activate the by passed zones, or can be set an auto-activation time. This user type has not access to User menu. Guest user has limited access and can arm only as programmed by Master or Installer. Guest user can disarm the system only if enabled. This user type has not access to User menu. Arming type (only for Guest) Total (T) Press F1 button to enable/disable the user to Total arming. A T on display indicates the user is enabled to arm in this mode. Partial 1 (P1) Partial 2 (P2) Patrol (R) Press F2 button to enable/disable the user to Partial 1 arming. A P1 on display indicates the user is enabled to arm in this mode. Press F3 button to enable/disable the user to Partial 2 arming. A P2 on display indicates the user is enabled to arm in this mode. Press F4 button to enable/disable the user to disarm. A D on display indicates the user is enabled to disarm. User Code * * * * * * Six digit code: the user must digit this code to act on system CHT key code NOT learnt Learnt CHT key combined to user is NOT stored. To learn the key for the user press the button then pass the key on reader. In the same way, it s possible to overwrite the key with a new one. CHT key combined to user is stored. To delete the key press the 0 (zero) button. 24

User block YES User cannot act on system (either with code or with key) NO User can act on system according to its settings Delete user YES Delete the user and restore its factory settings NO Save actual user settings SYSTEM TES Verify wired zones and CHT keys working System Test ON OFF To enter in test press the button. Open a zone, tamper line or pass a CHT key: the name of the user or key will appear on display To exit from test press the button OUTPUT TEST Verify outputs and wired siren working. Outputs Test Wired siren AUX 1 relay AUX 2 relay AUX 3 relay AUX 4 relay To test press the button button Alarm relay will be activated Control panel battery voltage level is displayed To test press the button. Output 1 switches To test press the button. Output 2 switches To test press the button. Output 3 switches To test press the button. Output 4 switches 25

KEY READER FEEDBACK When control panel is on and disarmed the LED on key reader is normally OFF. The LED lights on to signals events: LED OFF ON BLINKING Red Normal working TOTAL armed Alarm memory (at disarming, for 60 s) Green Normal working PARTIAL 1 armed One or more opened zones (at system disarmed) Blue Normal working PARTIAL 2 armed Multicoluor - - No communication with control panel 26

GSM-BUS EVENTS AND COMBINED MESSAGES Event on control panel Signalling Note Zone violation Alarm + eventual Opened Door Control panel Tamper Tamper Alarm No Power Line No Power Line Send 20 minutes after event (fixed time) Power Line Restored Power Back Send 5 minuti after event (fixed time) Low Battery Low Battery Low battery threshold: about 10,5 V Battery Level Restored Battery Restored Battery restore threshold: about 12 V Total Arming TOTAL arming Partial 1 Arming PARTIAL 1 arming Partial 2 Arming PARTIAL 2 arming Disarming DISARMING GSM In-live GSM active Send 1 each month (fixed time) SIM Expiring Expiring memo If programmed, 0 = no memo Dialler Tamper Dialler Tamper Vocal Messagges Alarm 1 call to each phone number, only alarm SMS COMMANDS XXXX = Remote Code Note: attention to spaces, insert them as indicated on table Action Command Total arming XXXX#instot Partial 1 arming XXXX#inspar1 Partial 2 arming XXXX#inspar2 Disarming XXXX#disins System Status XXXX#status GSM signal level XXXX#signal Credit request XXXX#riccre Change Remote Code XXXX#pin XXXX nnnn nnnn = new Remote Code Add/change telephone number XXXX#num n tttttttttt n = position number, from 1 to 8 tttttttttt = telephone number Delete telephone number XXXX#del n n = telephone number position Set SIM type XXXX#cre x number text X SIM type Values: C = contract T = rechargeable, credit req. by call, answer by SMS S = rechargeable, credit req. by SMS, answer by SMS F = rechargeable, credit req. by call, answer by flash message number Telephone number for credit request (only for T, S, F) text Text to add in SMS for credit request (only for S) SIM expiring memo XXXX#scad nnn nnn = number of days 27

28