GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Similar documents
GLOBAL RX. Ventilation unit with rotary heat exchanger

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

KOMFORT EC DB Suspended heat recovery air handling units

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

TopMaster Air Handling unit. Technical data

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

UNITES TERMINALES ET MINI CTA FIDJI

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired

We simplify construction

VEX100 series Air handling units with cross-flow heat exchanger

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Air Handling Units. Geniox. Quick guide

GLOBAL PX/RX/LP. Operation and maintenance instructions GLOBAL RX GLOBAL PX GLOBAL LP FW GLOBAL PX FW GLOBAL RX TOP GLOBAL PX TOP FW

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

VERSO Air Handling Units

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

EC L2. and humidity sensors. All units are supplied tested and ready to install.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

TopVent Design Handbook

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

The new Xcell EC High Efficiency Range Fresh air pure and simple

DAIKIN Air Handling Unit Modular

TopMaster Air Handling Unit

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

VERSO Air Handling Units

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

Description of the air handling unit

The ultimate in air handling units: directly and indirectly fired

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

air handling units AT THE LEADING EDGE OF AIR FLOW

Compact. Efficient. TROX.

The ultimate in air handling units: directly and indirectly fired

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Description of the air handling unit

VENTILATION WITH HEAT RECOVERY

TSEK VHR EC HEAT RECOVERY UNITS

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

RoofVent Design Handbook

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

SILVERTOP RANGE ENERGY RECOVERY

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

DVU-HP. Integrated Reversible Heat Pump System

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

VORT NRG RANGE COMMERCIAL VENTILATION NEW

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

GOLD RX, GOLD RX 12 GOLD RX,

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

EHH SERIES DRAW THROUGH FAN COILS CFM

Operation and maintenance instructions

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

AIR HANDLING UNITS ver B

AHU Plus. DX Air Handling Units

We simplify construction

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

Series VENTS VUT R WH ЕС

CLIMACIAT AIR COMPACT

AIR HANDLING UNITS MANDÍK

BARKELL AIR HANDLING UNITS

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

CONTENT: VEX308 Decentralised ventilation VEX308

Flexit air handling units C2 and UNI 2, 3,4

Blow through unit coolers LEX. Standard coolers for cooling & freezing rooms

SIMPLICITY FULL MODULARITY?

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Transcription:

Ceiling-mounted ventilation unit with plate heat exchanger Ventilation unit with plate heat exchanger for commercial applications. Well-suited for both newly constructed buildings and renovation projects Maximum airflow 4.000m³/h or 1.100 l/s. Temperature efficiency: up to 85 % Energy-efficient and quiet fans with composite or aluminum blades For installation indoors against ceiling Premium control technique with touchscreen HMI 20180607_a_EN-LP

THE MOST IMPORTANT POINTS DOUBLE FLOW HIGH PERFORMANCE VENTILATION UNITS Since 1997, Lemmens has specialised in the design and manufacture of dual flow ventilation units with energy recovery. From the outset, it adopted the principle that energy recovery means the search for efficiency it is therefore absurd to seek to recover heat energy without seeking to minimize power consumption. It opted for the systematic integration of fans equipped with high performance DC motors (TAC technology). With this technology, the GLOBAL line anticipated the most demanding levels of energy requirements to come, such as those set by the new standards ErP2018. Over time, it has developed more extensive and effective control. The most recent (TAC5) is at the forefront of the technology, due both to its internal functionality and its opening via communication (Modbus, TCP/IP, BACnet, KNX). PLUG-AND-PLAY UNITS The ventilation units are supplied as plug and play devices. The basic functions are pre-programmed and most of the accessories are pre-installed, pre-wired and pre-configured in factory. Once the remote control module has been connected, all that needs to be done is to switch the unit on and to change the pre-configured parameters if needed. ACCESS FOR OPERATORS The units generously sized doors ensure good access for maintenance work. The doors are mounted on sliding rails for ease of access. PLATE HEAT EXCHANGER The exchanger is a high efficiency (>80%) air/air plate heat exchanger, made of seawater-resistant aluminium. The exchanger complies with standard EN 308 and is Eurovent certified. HIGH-PERFORMANCE FANS The powerful EC fans ensure that sufficient external pressure is available, even with high airflows. The composite fan blades will ensure a better SFP and a higher fan efficiency, compared to aluminum fan blades. The efficiency level fulfills the ErP2018 requirements. HEATER ELEMENTS The units can be factory-fitted with an integrated water post heating or electric pre- or post heater element. The capacity of coil is modulated in order to maintain the setpoint. The water heating coil is ready-to-connect and delivered with a 3-way valve controlled by the TAC controller. The built in control system allows for all GLOBAL units to control an additional external heating (electric or water) and/or cooling exchanger. DAMPERS The GLOBAL units can be equipped with supply air and exhaust air dampers. In this case, the TAC control activates a fan startup delay when the unit is started. As an option, a spring return actuator is available. AIR FILTERS FILTER CLASSES As standard, the ventilation units are fitted with particularly effective and large-scale particulate matter bag filters, with filter class F7(EN779) / epm2,5 70% (ISO16890) for the supply air and M5 (EN779) / epm10 65% (ISO16890) for the exhaust air. CONTROL MODULES The integrated TAC5 control system can be connected to: TACtouch HMI with 4,3 capacitive touchscreen. For configuring and controlling the operation of a heat recovery unit. SAT MODBUS for configuration, visual display and controlling the operation via MODBUS RTU. SAT KNX for configuration, visual display and controlling the operation via KNX. TCP/IP module for communication via the internet (MODBUS TCP/IP protocol) and the heat recovery devices. Embedded web pages are used for the configuration, visual display and controlling the operation. BACnet gateway for configuration, visual display and controlling the operation via BACnet IP. SUMMER AND NIGHT TIME COOLING A 100% bypass is a standard feature on the GLOBAL units equipped with plate heat exchangers. It allows us to ensure the freecooling function and is automatically controlled on the indoor and outdoor temperatures. 3

series CONTROL OPTIONS AVAILABLE OPTIONS Internal electrical post heating coil (out) Internal electrical pre heating coil (in) Touchscreen HMI Internal water post heating coil (IBA) Exteral post heating/cooling coil (EBA) Motorised dampers (CT) Flexible sleeve 20mm (MS20) BACnet gateway Flexible sleeve 30mm (MS30) Condensate pump MODBUS RTU / ETHERNET WIFI KNX SAT3

MAIN ADVANTAGES EN1886 classifiaction: T3/TB2/F9/L2/ D1 High efficiency plate heat exchanger with Eurovent certification. Integrated pre- and post heating coil; electrical or water based. Fully integrated modulating capacity control. Innovative touchscreen interface with intuitive commissioning menu and integrated contextual aid. EC plug fans with composite blades for optimised efficiency and low noise levels. Aluminum fan blades available as an option. All of the access panels are mounted on sliding rails. Standard maintenance can be done by only one single technician. RAL7016 galvanized steel sheet construction with 30mm mineral wool thermal insulation. Circular duct connections with rubber seal; standard slip clamp connections for rectangular connections. Plug-and-play prewired unit. The complete unit is pre-wired and preconfigured in factory. Optional accessories are delivered as separate components, to be installed and wired on site. For units sizes 02 and 04: M5 / epm10 65% compact filters for both supply and extract air. For units sizes 06 and up: bag filters for both supply and extract air. F7 / epm2,5 70% for fresh air intake and M5 / epm10 65% for extract air. Proven TAC5 controller with precon- figuration. Max airflow of 4.000m³/h (1.100l/s) for unit size 20 ERP2018 optimised design Selection software available for free download Standard VDI6022 compliant

Flexible for a wide variety of solutions THE CORRECT OPERATING MODE IS AN IMPORTANT FACTOR AIRFLOW OR PRESSURE Whether the ventilation system is operated on the basis of constant pressure or constant airflow or via a 0 10V control system depends on the area of application and the specific on-site requirements. The integrated master/slave control system ensures that operation is always well-balanced. THE ADVANTAGES IN DETAIL Sufficiently high external pressure Constant airflow Demand control: constant airflow controlled by a 0 10 V signal Constant pressure via an external pressure sensor Constant airflow mode A typical area of application is nonresidential buildings, e.g. offices and business premises as well as schools, nurseries and sports halls with stable volumes of air. Demand control mode Alternatively, the airflow can be automatically adapted in line with the ventilation requirements and on a user-specific basis via the 0 10 V input, e.g. by means of a CO2 sensor, or the control system can be used via the customer s building service management/ instrumentation and control system. Constant pressure mode A prime example is undoubtedly apartment buildings with the opportunity to control the ventilation in individual apartments separately. The pressure remains constant even when the ventilation is increased or decreased in one apartment as required, by means of an airflow control unit. The airflow stays the same in all the other apartments, i.e. the ventilation system always runs within the ideal range. An external pressure sensor is required for constant pressure mode. THE 3 MAIN OPERATING MODES: Pa ppm V Pa Pa 154 sensor Sonde 2000 1000 10 5 220 185 1350 m 3 /h 0 m 3 /h m 3 /h 90 0 1800 90 0 m 3 /h Constant Airflow mode The airflow is kept constant, irrespective of external changes in pressure. Demand control mode A linear voltage/airflow ratio. The airflow can be regulated, e.g. by a CO2 sensor, via a 0 10 Volt signal. Constant pressure mode The pressure is kept constant, irrespective of external changes in pressure. An external pressure sensor is required. 6

Unit overview OPTIONAL CONTROL MODULES Touchscreen REMOTE CONTROL Remote control with touchscreen display and integrated timer with 4 actions per day and off day functionality. For configuring and controlling the operation of 1 heat recovery unit. All parameters are set and the unit can be operated via the touchscreen and all the 4 POSITION SWITCH With the four position switch, a unit can be switched to one its three configurable operating speeds and the off-position. operating parameters are displayed in a synoptic screen. Error display. For standalone solutions. Article HMI 372096 Article COM4 010007 SAT MODBUS Interface for configuration, visual display and controlling the operation via MODBUS RTU Article MODBUS 025006 SAT ETHERNET Interface for configuration, visual display and controlling the operation via MODBUS TCP/IP Article Ethernet 025072 BACnet gateway For communicating with the heat recovery devices via a BACnet TCP/IP protocol. Up to four units can ben integrated through the interface. The optional SAT Ethernet interface is required. Article BACnet 025095 SAT Wifi The Wifi interface with MODBUS TCP/IP, allows for a wireless connection to the air handling unit. Typically this accessory would be used in order to control the unit with the smart phone application. Article wifi 025071 SAT KNX Interface for configuration, visual display and controlling the operation via KNX Article KNX 025045 SAT3 The SAT3 combined with the TAC5 controller allows signalling the following with 2 free of potential contacts: Fan is actually running and alarm on a pre-set pressure variation. This status is expressed by closing the contact. Article SAT3 370005 7

EC PLUG FAN WITH COMPOSITE FAN BLADES (ALUMINUM BLADES OPTIONAL) 1 FRESH AIR FILTER 2 INTEGRATED CONTROLLER 3 4 EASY ACCESS SLIDING RAILS 4 4 INTEGRATED PREHEATING (ELECTRICAL) 5 2 HIGH EFFICIENCY PLATE HEAT EXCHANGER 6 INTEGRATED POST HEATING (WATER/ ELECTRICAL) 7 5 1 STAINLESS STEEL DRAIN PAN 8 EXTRACT AIR FILTER 9 4 4 100% BYPASS 10 5

SERIES 3 4 4 1 6 9 10 8 6 7 4 5

UNIT OVERVIEW GENERAL DESCRIPTION EC FANS WITH COMPOSITE FAN BLADE As standard, the EC fans are equipped with composite fan blades. Optionally, aluminum fan blades are available. The advantage of the composite fan blades are lower weight and aerodynamical shaping of the blades. All of this is finally resulting in a better SFP value. The CIRCULAR DUCT CONNEC- TIONS The duct connections for sizes 02, 04, 06 and 08 are circular and with rubber sealing. FILTERS All units size 06 and up, are equipped with bag filters. Sizes 02 and 04 are fitted with compact filters. The function of the filter is to keep both the air and the heat exchanger clean. The standard fresh air filter is of class F7(EN779) / epm2,5 70% (ISO16890), the standard extract air filter is of class M5 (EN779) / epm10 65% (ISO16890). An F7(EN779) / epm2,5 70% (ISO16890) filter on the extract fans are physically located on the cold air side of the plate heat exchanger, thus drastically reducing the emitted noise levels toward the occupied rooms in the building. RECTANGULAR DUCT CONNECTIONS The duct connections for sizes 10 and up, are rectangular standardised slip clamp duct connections. air side is not available since this would have a negative influence on the energy consumption. The filters are mounted in locking guide rails in order to facilitate removal and inspection. The filters guiderials are compliant to the requirements for filter bypass leakage to Class F9. The filter monitoring function is integrated in the standard configuration of the TAC5 controller. PLATE HEAT EXCHANGER The plate heat exchanger is a heat exchanger with a temperature efficiency of up to 85% and is installed under an angle to facilitate the evacuation of condensate. The plate heat exchanger is eurovent certified. TAC5 CONTROLLER The control equipment is completely integrated into the GLOBAL air handling unit. The controller controls and regulates the temperatures, airflows and other functions. The controller is pre-configured in factory with default settings. UNIT CASING The casing of the consits of metal panels. The outer skin is made of painted steel sheet, RAL7016. The inner skin is made of galvanized sheet steel. The panel thickness is 30mm with intervening insulation consisting of mineral wool. The doors are mounted in sliding rails to facilitate access to the internal components. The panels can be easily removed for even better access. EN1886 casing performance: Air leakage, class: L2 Thermal bridges: TB2 Thermal transmission: T3 Mechanical strength: D1 10

ANTI FROST STRATEGY Different antifreeze protection strategies are available for units with counterflow heat exchanger. - Supply airflow reduction - Bypass modulation - Internal electrical preheating coil DEFROST STRATEGY When the unit is used in cold climate conditions, a defrost option is available to avoid any risk linked to the icing of the plate heat exchanger. TAC controller will monitor the pressure drop of the heat exchanger to activate the defrost function in case of pressure drop increase in the extract flow. INTERNAL ELECTRICAL PRE HEATING COIL - IN The unit can be equipped with an internal electrical preheating coil. The coil is physically located between the fresh air filter and the supply air fan. The first function of the preheating coil is to protect the plate heat exchanger against freezing. TOUCHSCREEN HMI The hand-held user interface is a 4.3 touchscreen and is very user friendly. The HMI is rendering on-site commissioning intuitive and simple by means of the commissioning menu. The HMI is equipped with a 2 meter long connection cable and magnets. By means of the magnets, the HMI can be easily fixed on to any metallic surface. The defrost function consists in stopping the supply flow for a short period of time. INTERNAL WATER HEATING COIL - IBA The unit can be equipped with an internal water heating coil. The coil is physically located between the plate heat exchanger and the supply air duct connection. The water coil has internal water connections and is delivered with flexible connections in order to connect INTERNAL ELECTRICAL HEA- TING COIL - OUT it to the hydraulical system on the outside of the unit. The water coil is equipped with an anti-frost protection temperature sensor, which is mounted on the surface of the coil. The electrical post heating coil is physically located between the plate heat exchanger and the supply air duct connection. The electrical coil has two overheating protections, one with manual reset and one with automatical reset. When the electrical post heating coil is configured correctly, the coil is stopped immediately when the unit is stoppped, however, the fans are kept running for 90 seconds in order to cool down the electrical coil. 11

02 02 GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 100-580 m³/h 30-160 l/s DIMENSIONS (L x W x H) 1300 x 740 x 350 WEIGHT POWER CONNECTION RECOMMENDED FUSES 105 kg 1 x 230 V - 50 Hz 4 A / D-10000A-AC3 FILTER CLASS (MINIPLEAT) M5 (epm10 65%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST Ø 200 DUCT CONNECTIONS EXTRACT/OUTDOOR Ø 200 OPERATING RANGE -20... +40 C EN1886 CLASSIFICATION T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W kw/m 3 /s % C db(a) 300 83 117 1,4 82,8 17,0 34,1 400 111 171 1,5 80,6 16,5 35,6 500 139 248 1,8 79,0 16,1 38,2 580 160 312 1,9 77,7 15,8 40,0 Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4. Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 12 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

02 Série : dimensions DIMENSIONS (mm) 02 890 790 350 200 200 340 200 740 1300 75 1150 75 350 1380 02 IN IN Extract air Extract air Outdoor air Outdoor air BA + OUT OUT BA + Supply air Supply air TOP VIEW Exhaust air Exhaust air Right hand version Left hand version 13

04 04 External pressure [Pa] 500 400 300 200 100 0 100 200 300 400 500 600 Airflow [m³/h] 95 90 85 80 75 70 65 60 55 50 Efficiency [%] SFP=2,5 kw/m³s SFP=2 kw/m³s SFP=1,5 kw/m³s th GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 100-650 m³/h 30-180 l/s DIMENSIONS (L x W x H) 1300 x 950 x 350 WEIGHT POWER CONNECTION RECOMMENDED FUSES 125 kg 1 x 230 V - 50 Hz 4 A / D-10000A-AC3 FILTER CLASS (MINIPLEAT) M5 (epm10 65%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST DUCT CONNECTIONS EXTRACT/OUTDOOR OPERATING RANGE EN1886 CLASSIFICATION Ø250 Ø250-20 C... +40 C T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W W/m 3 /h % C db(a) 300 83 103 1,2 85,0 19,0 33,0 400 111 144 1,3 82,7 18,6 34,8 500 139 200 1,4 81,0 18,2 37,3 650 180 377 2,0 78,5 17,8 40,7 Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4.Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 14 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

04 Série : dimensions DIMENSIONS (mm) 04 1100 1000 350 Ø250 305 445 200 950 1300 75 1150 75 350 1380 04 IN IN Extract air Extract air Outdoor air BA + OUT OUT BA + Outdoor air Supply air TOP VIEW Supply air Exhaust air Right hand version Left hand version Exhaust air 15

06 06 External pressure [Pa] 500 400 300 200 100 0 100 200 300 400 500 600 700 800 900 1000 Airflow [m³/h] 95 90 85 80 75 70 65 60 55 50 Efficiency [%] SFP=2,5 kw/m³s SFP=2 kw/m³s SFP=1,5 kw/m³s th GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 200-1050 m³/h 55-290 l/s DIMENSIONS (L x W x H) 2100 x 900 x 435 WEIGHT POWER CONNECTION RECOMMENDED FUSES 195 kg 1 x 230V - 50Hz 8 A / D-10000A-AC3 FILTER CLASS (BAG FILTER) F7 (epm2,5 70%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST DUCT CONNECTIONS EXTRACT/OUTDOOR OPERATING RANGE EN1886 CLASSIFICATION Ø315 Ø315-20 C... +40 C T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W W/m 3 /h % C db(a) 600 167 294 1,8 83,0 18,9 38,3 800 222 419 1,9 81,0 18,5 41,0 900 250 501 2,0 80,1 18,4 42,3 1050 290 649 2,2 79,5 18,1 41,3 Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4.Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 16 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

06 Série : dimensions DIMENSIONS (mm) 06 1050 950 Ø315 435 240 420 240 1150 2100 75 1950 75 435 2180 06 IN Extract air Extract air Outdoor air OUT BA + IN Outdoor air BA + OUT TOP VIEW Supply air Supply air Exhaust air Right hand version Left hand version Exhaust air 17

08 08 External pressure [Pa] 500 400 300 200 100 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Airflow [m³/h] 95 90 85 80 75 70 65 60 55 50 Efficiency [%] SFP=2,5 kw/m³s SFP=2 kw/m³s SFP=1,5 kw/m³s th GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 200-1450 m³/h 55-400 l/s DIMENSIONS (L x W x H) 2100 x 1150 x 435 WEIGHT POWER CONNECTION RECOMMENDED FUSES 230 kg 1 x 230V - 50Hz 8 A / D-10000A-AC3 FILTER CLASS (BAG FILTER) F7 (epm2,5 70%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST DUCT CONNECTIONS EXTRACT/OUTDOOR OPERATING RANGE EN1886 CLASSIFICATION Ø315 Ø315-20 C... +40 C T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W kw/m 3 /s % C db(a) 800 220 336 1,5 83,4 18,2 37,2 1100 306 524 1,7 81,0 17,7 38,6 1300 361 697 1,9 79,9 17,5 39,4 1450 400 824 2,1 79,4 17,3 40,4 Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4.Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 18 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

08 Série : dimensions DIMENSIONS (mm) 08 1300 1200 Ø315 435 325 545 280 1150 2100 75 1950 75 435 2180 08 IN IN Extract air Outdoor air OUT BA + OUT BA + Supply air TOP VIEW Exhaust air Right hand version Left hand version 19

10 10 External pressure [Pa] 500 400 300 200 100 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 Airflow [m³/h] 95 90 85 80 75 70 65 60 55 50 Efficiency [%] SFP=2,5 kw/m³s SFP=2 kw/m³s SFP=1,5 kw/m³s th GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 250-1850 m³/h 70-510 l/s DIMENSIONS (L x W x H) 2100 x 1450 x 435 WEIGHT POWER CONNECTION RECOMMENDED FUSES 270 kg 1 x 230V - 50Hz 8 A / D-10000A-AC3 FILTER CLASS (BAG FILTER) F7 (epm2,5 70%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST 400 x 300 DUCT CONNECTIONS EXTRACT/OUTDOOR 800 x 300 OPERATING RANGE EN1886 CLASSIFICATION -20 C... +40 C T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W kw/m 3 /s % C db(a) 900 250 332 1,3 84,0 18,4 35,5 1300 361 560 1,6 81,2 17,8 38,3 1700 472 911 1,9 79,4 17,3 42,1 1850 510 956 2,0 78,8 17,3 42,4 Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4.Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 20 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

10 Série : dimensions DIMENSIONS (mm) 10 1600 1500 435 840 440 1450 2100 75 1950 75 10 IN IN + 435 340 340 2180 Extract air Extract air Outdoor air Outdoor air BA + OUT OUT BA TOP VIEW Supply air Supply air Exhaust air Exhaust air Right hand version Left hand version 21

12 12 External pressure [Pa] 500 95 90 400 85 300 200 100 60 55 0 50 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 Airflow [m³/h] SFP=2,5 kw/m³s SFP=2 kw/m³s SFP=1,5 kw/m³s th 80 75 70 65 Efficiency [%] GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 300-2200 m³/h 80-610 l/s DIMENSIONS (L x W x H) 2250 x 1550 x 510 WEIGHT POWER CONNECTION RECOMMENDED FUSES 325 kg 1 x 230 V - 50 Hz 10 A / D-10000A-AC3 FILTER CLASS (BAG FILTER) F7 (epm2,5 70%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST 500 x 400 DUCT CONNECTIONS EXTRACT/OUTDOOR 800 x 400 OPERATING RANGE -20 C...+40 C EN1886 CLASSIFICATION T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W kw/m 3 /s % C db(a) 1000 278 328 1,2 84,5 18,5 35,0 1400 389 492 1,3 82,2 18,0 35,6 1800 500 723 1,5 80,7 17,6 38,2 2200 610 1059 1,7 79,5 17,3 40,9 Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4.Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 22 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

12 Série : dimensions DIMENSIONS (mm) 12 1700 1600 510 840 540 1550 2250 75 750 1350 75 440 440 2350 12 IN IN + Extract air Extract air Outdoor air Outdoor air BA + OUT TOP VIEW OUT BA Supply air Supply air Exhaust air Exhaust air Right hand version Left hand version 23

13 13 External pressure [Pa] 500 95 90 400 85 300 200 100 60 55 0 50 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 Airflow [m³/h] SFP=2,5 kw/m³s SFP=2 kw/m³s SFP=1,5 kw/m³s th 80 75 70 65 Efficiency [%] GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 300-2600 m³/h 80-720 l/s DIMENSIONS (L x W x H) 2250 x 1550 x 510 WEIGHT POWER CONNECTION RECOMMENDED FUSES 325 kg 1 x 230 V - 50 Hz 10 A / D-10000A-AC3 FILTER CLASS (BAG FILTER) F7 (epm2,5 70%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST 500 x 400 DUCT CONNECTIONS EXTRACT/OUTDOOR 800 x 400 OPERATING RANGE -20 C... +40 C EN1886 CLASSIFICATION T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W kw/m 3 /s % C db(a) 1400 389 511 1,3 82,2 17,0 35,6 1800 500 740 1,5 80,7 16,6 38,2 2200 611 1054 1,7 79,5 16,4 40,9 2600 720 1467 2,0 78,6 16,1 43,1 Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4.Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 24 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

12 Série : dimensions DIMENSIONS (mm) 13 1700 1600 510 840 540 1550 2250 75 750 1350 75 440 440 2350 13 IN IN + Extract air Extract air Outdoor air Outdoor air BA + OUT TOP VIEW OUT BA Supply air Supply air Exhaust air Exhaust air Right hand version Left hand version 25

14 14 External pressure [Pa] 600 500 400 300 200 100 0 100 300 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500 2700 2900 Airflow [m³/h] 95 90 85 80 75 70 65 60 55 50 Efficiency [%] SFP=2,5 kw/m³s SFP=2 kw/m³s SFP=1,5 kw/m³s th GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 300-2900 m³/h 80-800 l/s DIMENSIONS (L x W x H) 2250 x 1790 x 510 WEIGHT POWER CONNECTION RECOMMENDED FUSES 360 kg 1 x 230V - 50Hz 10 A / D-10000A-AC3 FILTER CLASS (BAG FILTER) F7 (epm2,5 70%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST 500 x 400 DUCT CONNECTIONS EXTRACT/OUTDOOR 1000 x 400 OPERATING RANGE EN1886 CLASSIFICATION -20 C... +40 C T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W kw/m 3 /s % C db(a) 1500 417 500 1,1 82,8 18,8 35,2 2100 583 847 1,4 80,7 18,3 39,1 2500 694 1150 1,7 79,7 18,2 41,9 2900 800 1533 2,0 79,2 18,0 44,0 Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4.Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 26 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

14 Série : dimensions DIMENSIONS (mm) 14 1940 1840 510 1040 540 1790 2250 75 750 1350 75 440 440 2350 14 IN Extract air Outdoor air OUT BA + OUT BA IN + Supply air TOP VIEW Exhaust air Right hand version Left hand version 27

16 16 Available external pressure (Pa) AVAILABLE SOON Airflow (m 3 /h) GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 300-3.000m³/h 80-0l/s DIMENSIONS (L x W x H) WEIGHT POWER CONNECTION RECOMMENDED FUSES 3 x 400V + N - 50Hz A FILTER CLASS (BAG FILTER) F7 (epm2,5 70%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST DUCT CONNECTIONS EXTRACT/OUTDOOR OPERATING RANGE EN1886 CLASSIFICATION -20 C... +50 C T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W kw/m 3 /s % C db(a) Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4.Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 28 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

16 Série : dimensions DIMENSIONS (mm) 16 16 Extract air Extract air Outdoor air Outdoor air Supply air Supply air TOP VIEW Exhaust air Exhaust air 29

20 20 Available external pressure (Pa) AVAILABLE SOON Airflow (m 3 /h) GENERAL TECHNICAL SPECIFICATIONS AIR VOLUME 400-4.000m³/h 110-00l/s DIMENSIONS (L x W x H) WEIGHT POWER CONNECTION RECOMMENDED FUSES 3 x 400V + N - 50Hz A FILTER CLASS (BAG FILTER) F7 (epm2,5 70%) / M5 (epm10 65%) DUCT CONNECTIONS SUPPLY/EXHAUST DUCT CONNECTIONS EXTRACT/OUTDOOR OPERATING RANGE EN1886 CLASSIFICATION -20 C... +50 C T3/TB2/F9/L2/D1 AIRFLOW ABSORBED POWER SFP THERMAL EFFICIENCY T AFTER HEAT EXCHANGER SOUND PRESSURE m 3 /h l/s W kw/m 3 /s % C db(a) Conditions : 1. All values at 200Pa external pressure. 2. T after heat exchanger at -10 C, 90%RH and +22 C, 50% HR. 3. Thermal efficiency at -10 C, 90%RH and +22 C, 50% HR. 4.Sound pressure for ducted unit in free field conditions at 3m. 5. All data for composite fans variant 30 This document is an overview of technical specifications. Please do refer to our selection software for detailed and updated information.

14 Série : dimensions DIMENSIONS (mm) 20 20 20 Extract air Extract air Outdoor air Outdoor air Supply air Supply air Exhaust air Exhaust air TOP VIEW 31

Series Filter replacement set Series : accessoires Specification: GLOBAL_LP_XX_X_XXX Unit size: 02, 04, 06, 08, 10, 12, 13, 14, 16, 20 Supply air: Right (R) / Left (L) Fan type: none = Composite, ALU = Aluminum FILTER REPLACEMENT SET The function of the filter is to keep both the air and the heat exchanger clean. To keep the plate heat exchanger clean, an M5 (EN779) / epm10 65% (ISO16890) filter class will suffice. Filterclass of the supply air filter: F7 (EN779) / epm2,5 70% (ISO16890). Filterclass of the extract air filter: M5 (EN779) / epm10 65% (ISO16890). MODEL Air intake Extract air LABEL 02 510134 M5 / epm10 65% M5 / epm10 65% Filter kit M5/M5 Global LP 02 02 510127 F7 / epm2,5 70% M5 / epm10 65% Filter kit M5/F7 Global LP 02 04 510135 M5 / epm10 65% M5 / epm10 65% Filter kit M5/M5 Global LP 04 04 510128 F7 / epm2,5 70% M5 / epm10 65% Filter kit M5/F7 Global LP 04 06 510129 F7 / epm2,5 70% M5 / epm10 65% Filter kit M5/F7 Global LP 06 08 510130 F7 / epm2,5 70% M5 / epm10 65% Filter kit M5/F7 Global LP 08 10 510331 F7 / epm2,5 70% M5 / epm10 65% Filter kit M5/F7 Global LP 10 12/13 510132 F7 / epm2,5 70% M5 / epm10 65% Filter kit M5/F7 Global LP 12/13 14 510133 F7 / epm2,5 70% M5 / epm10 65% Filter kit M5/F7 Global LP 14 16/20 F7 / epm2,5 70% M5 / epm10 65% 32

Motorised dampers (CT) Series : accessoires MOTORISED DAMPER - CT Circular adapter (IRS) Series : accessoires The CT dampers are used as shut-off dampers. Shut-off dampers are used if the air handling unit is idle during some period or if a water coil is used. The dampers are made of galvanized steel, the blades of the rectangular dampers are made of extruded aluminum. The blades have rubber seals. According EN 1751, air tightness of circular dampers is of class 2, the air tightness of rectangular dampers is of classe 3. Specification: Connection frame [mm] Duct dimensions [mm] None = 0 On/off = 1 Spring return = 2 CTXX_XXX-XXX_1 MODEL OUTLET INLET Inner dimensions Outer dimensions 02 882861 882861 Ø200 n.a. CT_200 04 882862 882862 Ø250 n.a. CT_250 06/08 882863 882863 Ø315 n.a. CT_315 LABEL 10 883203 360 x 260 440 x 340 CT40_360-260 10 883206 760 x 260 840 x 340 CT40_760-260 12/13/14 883204 460 x 360 540 x 440 CT40_460-360 12/13 883207 760 x 360 840 x 440 CT40_760-360 14 883208 960 x 360 1040 x 440 CT40_960-360 16/20 883205 CT40_ 16/20 883209 CT40_ CIRCULAR ADAPTER - IRS For units (AHU s, external coils,...) with rectangular connections, non insulated rectangular/circular adapters are available. The adapter is fabricated in galvanized sheet metal. The circular duct connection is fitted with a rubber seal. Specification: IRS_XXX-XXX_XXX Frame outer dimensions Circular size MODEL OUTLET INLET DIMENSIONS DUCT LABEL 10 883183 400 x 300 Ø315 IRS_400-300_315 10 883179 800 x 300 Ø315 IRS_800-300_315 12/13/14 883184 500 x 440 Ø400 IRS_500-440_400 12/13 883180 800 x 400 Ø400 IRS_800-400_400 14 883181 1000 x 400 Ø400 IRS_1000-400_400 16/20 883185 IRS_ 16/20 883182 IRS_ 33

Flexible sleeve 20mm (MS20) Series : accessoires FLEXIBLE SLEEVE 20mm - MS20 Flexible sleeve 30mm (MS30) Series : accessoires The flexible sleeves type MS20 prevents the transmission of vibrations and noise along the ventilation ductwork. The sleeve is made of fibreglass and are classified M0 for fire resistance, Class B for air tightness (EN 15727 and EN 1751). The operating range is from -30 C up to +110 C and for pressures up to 2000Pa. The 20mm connection frame is made from 1mm thick galvanized steel. Specification: Connection frame width [mm] Duct dimensions [mm] MSXX_XXX-XXX MODEL OUTLET INLET Inner dimensions Outer dimensions 02 883189 883189 Ø200 n.a. MS_200 04 883187 883187 Ø250 n.a. MS_250 06/08 883188 883188 Ø315 n.a. MS_315 LABEL 10 883189 400 x 300 440 x 340 MS20_400-300 10 883192 800 x 300 840 x 340 MS20_800-300 12/13/14 883190 500 x 400 540 x 440 MS20_500-400 12/13 883193 800 x 400 840 x 440 MS20_800-400 14 883194 1000 x 400 1040 x 440 MS20_1000-400 16/20 883191 MS20_ 16/20 883195 MS20_ FLEXIBLE SLEEVE 30mm - MS30 The flexible sleeves type MS30 prevents the transmission of vibrations and noise along the ventilation ductwork. The sleeve is made of fibreglass and are classified M0 for fire resistance, Class B for air tightness (EN 15727 and EN 1751). The operating range is from -30 C up to +110 C and for pressures up to 2000Pa. The 30mm METU connection frame is made from 1mm thick galvanized steel. Specification: MSXX_XXX-XXX MODEL OUTLET Connection frame width [mm] Duct dimensions [mm] INLET Inner dimensions Outer dimensions LABEL 10 883196 380 x 280 440 x 340 MS30_380-280 10 883199 780 x 280 840 x 340 MS30_780-280 12/13 883197 480 x 380 540 x 440 MS30_480-380 12/13 883200 780 x 380 840 x 440 MS30_780-380 14 883197 480 x 380 540 x 440 MS30_480-380 14 883201 980 x 380 1040 x 440 MS30_980-380 16/20 883198 MS30_ 16/20 883202 MS30_ 34

Internal Water post heating (IBA) Series : accessoires INTERNAL WATER POST HEATING - IBA The IBA coil uses hot water for post-heating the supply air. The coil is integrated inside the unit and is located between the plate heat exchanger and the supply air duct connections. The finned-tube heat exchangers consist of copper tubes and aluminum fins with 2,5mm spacing. The male threaded pipe is made of brass. The coils are classified PN16. Specification: Coil type & # of rows Coil size IBA_XX-XX MODEL RIGHT LEFT VARIANT Ø LABEL 02/04 883224 883225 2-row heating 1 / 2 IBA_2H_LP 02/04 06 883228 883229 2-row heating 1 / 2 IBA_2H_LP 06 08/10 883232 883233 2-row heating 1 / 2 IBA_2H_LP 08/10 12/13/14 883236 883237 2-row heating 1 / 2 IBA_2H_LP 12/13/14 16/20 883240 883241 2-row heating 1 / 2 IBA_2H_LP 16/20 02/04 883226 883227 4-row heating 1 / 2 IBA_4H_LP 02/04 06 883230 883231 4-row heating 1 / 2 IBA_4H_LP 06 08/10 883234 883235 4-row heating 1 / 2 IBA_4H_LP 08/10 12/13/14 883238 883839 4-row heating 1 / 2 IBA_4H_LP 12/13/14 16/20 883242 883243 4-row heating 1 / 2 IBA_4H_LP 16/20 35

External insulated casings (ECA) Series : accessoires Coils for external insulated casings (EBA) Series : accessoires EXTERNAL INSULATED CASING FOR COILS- ECA The external insulated casings are fabricated in galvanized steel sheet. the outer sheet is painted in RAL7016. The double-skin panels contain 30mm mineral wool. The casings can be used to integrate external cooling, heating or direct expansion coils (EBA). The standard connection frame is 15mm, other connection frame types are available as an option: 20mm slip clamps, 30mm METU frame. Specification: ECA_XXX-XXX_XX/XX Duct size [mm] Casing size[mm] MODEL DUCT SIZE Label 02/04 883174 Ø250 320 x 600 x 400 ECA_250_02/04 08 882740 Ø250 ECA_250_08 10/12/13 882338 655 x 250 ECA_655-250_13 14/16 882339 755 x 350 ECA_755-350_16 COILS FOR EXTERNAL INSULATED CASING - EBA The EBA coil uses hot water for post-heating the supply air. The coil is to be integrated in an insulated casing ECA. The finned-tube heat exchangers consist of copper tubes and aluminum fins with 2,5mm spacing. The male threaded pipe is made of brass. The coils are classified PN16. Specification: EBA_XX_XX/XX Function & # of rows Coil size MODEL 2H 4H 4C DX Label 02/04 883175 883176 883177 883178 EBA_xx_02/04 08 882340 882341 882342 882343 EBA_xx_08 10/12 882344 882345 882346 882347 EBA_xx_10/12 14/16 882348 882349 882350 882351 EBA_xx_14/16 36

Electrical coils (out/in) Series : accessoires Drain pump Series : accessoires INTERNAL ELECTRICAL PRE- & POST HEATING - in & out The electrical coil is used for post-heating the supply air. The electrical coil is located between the plate heat exchanger and the supply air duct connections. There are two overheating protections, one with manual reset and one with automatic reset. All electrical connections are protected against electrocution. Specification: Pre/Post heating [IN/OUT] Heating capacity [kw] Supply voltage: 1=3x400V / 0=1x230V Coil size _XXX_XX-X_XX/XX MODEL out in CAPACITY out CAPACITY in POWER SUPPLY LABEL 02 883210 883216 3kW 3kW 230V _IN/OUT_03_0 04 883211 883217 3kW 3kW 230V _IN/OUT_03_0 06 883212 883218 4,5kW 4,5kW 400V _IN/OUT_4,5_1 08 883213 883219 6kW 6kW 400V _IN/OUT_06_1 10 883213 883220 6kW 6kW 400V _IN/OUT_06_1 12/13 883214 883220 9kW 9kW 400V _IN/OUT_09_1 14 883214 883222 9kW 9kW 400V _IN/OUT_09_1 16/20 883215 883223 400V _IN/OUT_???_1 CONDENSATE PUMP The condensate generated by either the plate heat recovery unit or the cooling coil will use the gravitational force to flow out of the unit. If gravitational force cannot be used, an optional condensate pump is available. The condensate pump has its integrated float switch and water level alarm. MODEL IP Class Capacity 883244 IP68 12l/h 37

We make every breath count. Version: 07/06/2018 We reserve the right for changes.