Coating Steel Water- Storage Tanks

Similar documents
Swing-Check Valves for Waterworks Service, 2-In. Through 48-In. (50-mm Through 1,200-mm) NPS

Ductile-Iron Pipe, Centrifugally Cast

Cement Mortar Protective Lining and Coating for Steel Water Pipe 4 In. (100 mm) and Larger Shop Applied

Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings

Steel Pipe Flanges for Waterworks Service, Sizes 4 In. Through 144 In. (100 mm Through 3,600 mm)

Bolted Sleeve-Type Couplings for Plain-End Pipe

1 2 Stanley Security Solutions $ % 1,200 $8,700,000 $2, ,800 Indianapolis, Ind.

Fire Sprinkler Success Stories: How do Sprinklers Save Lives. Viking Group, Inc.

REPLACEMENT PARTS LIST

Sanitizing Sink Heater

Oklahoma and Texas Interdependency Along the I-35 Corridor

Medina. Laminate Casegoods

Table W-4...Total Improvement Expenditures by Homeowner Characteristics:

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2007

Ultra-Glo. Replacement Parts List. Ceramic Infrared Strip Heaters. UGA, UGAL, UGAH, and UGAHL Series CAUTION

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2013

H gh-p led Combust ble Storage. Application Guide 2009 Edition

- Residential Fire Sprinkler -

Glo-Ray Round Heated Stone Shelves

Refrigerated Drop-In Wells

T H I R D Q UA R T E R

F O U R T H Q UA R T E R

Green Infrastructure Requirements and Incentives

Literature Review Green Schoolyard Manual

ICC 902/ APSP 902/ SRCC Solar Pool and Spa Heating System Standard

Bold items are particular to the City of Euless

LANCASTER COUNTY PLANNING COMMISSION PUBLIC MEETING AGENDA. Monday, August 27, 2018

STORMWATER FACILITIES OPERATION AND MAINTENANCE PLAN. Example Commercial Project. February 21, 2018

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Bakery Case. Replacement Parts List. BC Series CAUTION

Insulated High Temperature Hook-Up Wire; Types ET (250 Volts), E (600 Volts), and EE (1000 Volts)

J. WILLIAM (BILL) BROWN Office Phone: (608) Cellular Phone: (817)

2016 Fall Revision Cycle Consent Document NFPA 1000

Annual Reporting for FY Regional Supplement for New Development and Redevelopment

Sýnishorn ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais

Joe Pool Lake Lake Master Plan Public Information Meeting Presentation of Final Draft Revision July 31, 2018

Food Scrap Composting Challenges and Solutions in Illinois

INTERNATIONAL STANDARD

STELLA Cert no. BV-COC

Correlating Committee on Automatic Sprinklers

ISO INTERNATIONAL STANDARD. Safety of machinery Laser processing machines Part 1: General safety requirements

National Fire Protection Association (NFPA) Fire Service Occupational Safety and Health Technical Committee Meeting. October 10 12, 2011 Baltimore, MD

STYLE. Desk-mounted hutches with elegant, radiused front doors preserve workspace and create privacy when used with optional tack panels.

J A N UA RY J U N E

Average Number of Deficiencies Cited Per Survey by Region V States and Nation on Standard and Complaint Surveys FY 2016

Certification Board Preapproved Courses for Continuing Education Units

M u s e u m. museum storage. & special collections guide book. Protect. Preserve. S t o r a g e S o l v e d

CRP 336: REGIONAL AND ENVIRONMENTAL PLANNING FOUNDATIONS

Licensed exclusively to SABS. Copying and network storage prohibited.

Obstructions and ESFR Sprinklers Phase 2 FINAL REPORT

CORPORATION OF THE TOWNSHIP OF ESQUIMALT DESIGN REVIEW COMMITTEE AGENDA. WEDNESDAY, May 13, :00 P.M. ESQUIMALT COUNCIL CHAMBERS

AGENCY: Federal Emergency Management Agency, DHS. SUMMARY: Flood hazard determinations, which may include additions or

Australian/New Zealand Standard

OHIO UNIVERSITY RADIATION SAFETY REVIEW

ECLIPSE EXECUTIVE OFFICE

Presentation Item C Annotated Model Outline for a Framework for a Green Infrastructure Plan

2007 ASME Boiler & Pressure Vessel Code 2007 Edition July 1, 2007

ISO INTERNATIONAL STANDARD

TYPE APPROVAL CERTIFICATE

This document is a preview generated by EVS

DOE FUNDAMENTALS HANDBOOK INSTRUMENTATION AND CONTROL Volume 1 of 2

HOUZZ & HOME. Overview of U.S. Renovation in 2017 and Houzz Inc.

ISO INTERNATIONAL STANDARD

MEETING MINUTES NFPA Technical Correlating Committee on Safety to Life January 6, 2011 ROC Meeting The Wyndham Phoenix, Phoenix, AZ

5.07 Air Replenishment Systems

AS/NZS :2015

Professional Resume of RANDY J. BICKNESE, P. E. February 2017

Store Staff and Service Differentiate Retailer Experience and Influence Brand Selection

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

I. Welcome and call to order at 8:00am by Acting Chair Gorman. Introductions- members and guests

Hello. What can I do for you? QUALITY CUSTOMER SERVICE. Joseph Griffith Regional Sales Manager. Cooling Tower Depot is Global, I am Local

Beautification Advisory Committee Mission Statement and Goals & Objectives

12/4/20 Fine and Applied Arts City Planning and Landscape Architecture Karl B. Lohmann Papers, Box 1:

Centennial Energized Electrical Work Permit Instructions

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

25% 25% manufacturing. TOP 100 military friendly employer RANK: 77. Advanced Technology Services (ATS) Archer Daniels Midland Company

Major U.S. Cities Using National Standard Fire Hydrants, One Century After the Great Baltimore Fire

Rezoning Issues Setting a Foundation for Zoning Decisions

Ranking US Cities Oil Addiction: Sprawl and Car Commuting Emerge as Real Estate Risk Factors

Table of Contents. Executive Summary... vii

BACKGROUND PROJECT DESCRIPTION. Memo

ISO Safety of machinery Laser processing machines Part 1: General safety requirements

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

1. Welcome. Robert Smith, Chair. 2. Introductions and Update of Committee Roster. (attached)

U.S. Codes & Standards for Energy Storage Systems. Joe Cain, P.E. Chair, SEIA Codes & Standards Working Group

Safety Program. Eastern Electrical Testing Corporation 2 Skyline Drive Clarks Summit, PA (570)

Department of City & Metropolitan Planning, University of Utah.

AVERAGE RADON CONCENTRATION: Test has met minimum EPA sampling duration.

INTERNATIONAL STANDARD

Positive Experience Also Can Lead Shoppers to Consider Brand, Retailer for Other Purchases

Inventory of the Alfred R. Golzé Photographs, (bulk ) No online items

Property Inspected: 623 Pine St, Macon, GA 31201

True Auto-Purge System

NFPA Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems

ELEVATOR RESCUE PROCEDURE

Property Inspected: 1228 Radcliffe Ave, Kingsport, TN 37664

Australian Standard. Fire protection for mobile and transportable equipment AS AS

Facilities Planning & Construction Report nd Quarter Ending December 31, 2016

ISO INTERNATIONAL STANDARD. Personal protective equipment Occupational footwear. Équipement de protection individuelle Chaussures de travail

Landmarks Minutes October 12, I. Call to Order Ms. Carol Rogers, Chairperson, called the meeting to order.

Transcription:

SM ANSI/AWWA D102-17 (Revision of ANSI/AWWA D102-14) AWWA Standard Coating Steel Water- Storage Tanks Effective date: Dec. 1, 2017. First edition approved by AWWA Board of Directors Feb. 11, 1964. This edition approved June 11, 2017. Approved by American National Standards Institute Aug. 3, 2017.

Committee Personnel The Revision Task Force, which developed this edition of ANSI/AWWA D102, consisted of the following personnel: Joe W. Davis, Chair General Interest Members R. Boswell, Boswell s Consulting Testing Services, Round Rock, Texas E. Brackman, RFI Consultants LLC, Phoenix, Ariz. R.A. Kufaas, Norske Corrosion & Inspection Services Ltd., Surrey, B.C., Canada G.R. Stein, Tank Industry Consultants, Indianapolis, Ind. S.C. Vidika, Dixon Engineering Inc., Medina, Ohio D.J. Zienty, Short Elliott Hendrickson Inc., St. Paul, Minn. Producer Members C.S. Bull, Landmark Structures, Fort Worth, Texas J.W. Davis, Tesla NanoCoatings Inc., Massillon, Ohio T. Enoch, Induron Protective Coatings, Ottsville, Penn. R. Hasak, Tnemec Company Inc., North Kansas City, Mo. T.D. Ippoliti, Sherwin-Williams Company, Indianapolis, Ind. M.L. Jones, International Paint LLC, Greenwood, Ind. L.D. Scott, Paso Robles Tank Brown-Minneapolis Tank Inc., Paso Robles, Calif. C. Spoelstra, Caldwell Tanks Inc., Urbandale, Iowa User Members R.R. Wawrzyniakowski Jr., Pennsylvania American Water, Wampum, Penn. The AWWA Standards Committee on Steel and Composite Water Storage Tanks, which reviewed and approved this standard, had the following personnel at the time of approval: Stephen W. Meier, Chair Gregory R. Stein, Vice-Chair General Interest Members D.M. Algranti, Albert A. Webb Associates, Riverside, Calif. J.W. Birkhoff, Birkhoff, Hendricks & Carter LLP, Dallas, Texas iii

J.D. Brock, Consulting Services Logistics, Toledo, Ohio M.M. Coleman,* Standards Council Liaison, Wade Trim Associates Inc., Detroit, Mich. E. Darrimon, Bay Area Coating Consultants Inc., Denair, Calif. W.J. Dixon, Dixon Engineering Inc., Lake Odessa, Mich. R.E. Gell, O Brien & Gere Engineers, Syracuse, N.Y. M.L. Hickey, Murray, Smith & Associates Inc., Portland, Ore. F.S. Kurtz,* Standards Engineer Liaison, AWWA, Denver, Colo. S.W. Meier, Tank Industry Consultants, Indianapolis, Ind. R.L. Moore, St. Louis, Mo. G.R. Stein, Tank Industry Consultants, Indianapolis, Ind. J.I. Strand, CBS Squared Inc., Chippewa Falls, Wis. T.A. Tovey, CH2M, Bellevue, Wash. Producer Members G.A. Burke, Caldwell Tanks Inc., Louisville, Ky. W.J. Czaska, CB&I Inc., Plainfield, Ill. J.W. Davis, Tesla NanoCoatings Inc., Massillon, Ohio K.T. Fuller, Phoenix Fabricators & Erectors Inc., Avon, Ind. J. Grendzinski, Landmark Structures, Wheaton, Ill. B.E. Kromer, Tank Builders Inc., Euless, Texas K. McGuire, CST Storage, Parsons, Kan. R. Pawski, Landmark Structures, Wheaton, Ill. L.D. Scott, Paso Robles Tank Brown-Minneapolis Tank Inc., Paso Robles, Calif. User Members J. Camarena, East Bay Municipal Utility District, Oakland, Calif. T.M. Dawson, Emerald Coast Utilities Authority, Pensacola, Fla. M. Gaffey, Naval Facilities Expeditionary Warfare Center, Washington, D.C. R.E. McCuller, City of Grand Prairie, Grand Prairie, Texas N.J. Meder, Connecticut Water Co., Clinton, Conn. J.L. Ortiz, San Francisco Public Utilities Commission, San Francisco, Calif. R.B. Potts, Louisville Water Company, Louisville, Ky. G. Terrell, Birmingham Water Works Board, Birmingham, Ala. * Liaison, nonvoting Alternate iv

Contents All AWWA standards follow the general format indicated subsequently. Some variations from this format may be found in a particular standard. SEC. PAGE SEC. PAGE Foreword I Introduction... vii I.A Background... vii I.B History... vii I.C Acceptance... vii II Special Issues... viii III Use of This Standard... viii III.A Purchaser Options and Alternatives... ix III.B Modification to Standard... ix IV Major Revisions... ix V Comments... ix Standard 1 General 1.1 Scope... 1 1.2 Purpose... 1 1.3 Application... 1 2 References... 1 3 Definitions... 3 4 Requirements 4.1 Materials... 4 4.2 Data to Be Provided... 4 4.3 Outside Coating Systems... 5 4.4 Inside Coating Systems... 10 4.5 Coating Materials... 13 4.6 Surface Preparation... 14 4.7 Application... 17 4.8 Safety Precautions... 18 5 Verification 5.1 Inspection and Testing... 18 5.2 First-Anniversary Inspection... 18 6 Affidavit of Compliance 6.1 Affidavit Statement... 19 Appendixes A Selection and Use of Coating Systems. A.1 General... 21 A.2 Outside Coating Systems... 22 A.3 Inside Coating Systems... 25 A.4 Dissimilar Metals... 27 A.5 Inaccessible Areas... 28 A.6 Inside of Nonwater-Containing Elevated Tank Pedestals... 36 A.7 Surface Preparation... 36 A.8 Coating Application... 41 A.9 Tank Lettering and Logos (Signage). 43 A.10 Testing and Inspection... 44 A.11 First-Anniversary Inspection... 45 A.12 Placing in Service... 46 A.13 Cathodic Protection System Considerations... 46 v

SEC. PAGE SEC. PAGE A.14 Bibliography... 46 B Environmental Concerns... 49 C Default Checklist... 51 Tables 1 Portions of the Tank Surface Considered for Recoating... 20 A.1 Roof Construction Options for New Tanks... 33 vi