Greening streets, retrofit rain gardens, Nottingham

Similar documents
Alma Road Rain Gardens, London

Renfrew Close, London

Stebonheath Primary School, Llanelli

Cambrian North Basin, Llanelli

Priors Farm Estate SuDS Retrofitting Project, Cheltenham

Manor Ponds, Sheffield

Forest Way School Coalville, Leicestershire

Grey to Green Phase 1, Sheffield

Why we need the Counters Creek storm relief sewer

Springhill Cohousing Development, Springfield Road, Stroud, Gloucestershire

Queen Caroline Estate, London

Retrofitting SuDS. Virginia Stovin. Department of Civil and Structural Engineering Pennine Water Group University of Sheffield.

Project description Environmental issues Beneficiaries Administrative data Read more

Northumbrian Water is required to provide investment to reduce spills at Whitburn and St Peter s, Sunderland in

Sewer Flooding Alleviation in the Counters Creek Catchment

4. CONCEPT PLAN DEVELOPMENT

JCCC Campus Stormwater Project: Retrofitting Yesterday s Parking Lots With Today s Best Management Practices

Howard Street, Salford, Manchester

Green Roofs and Stormwater Management Virginia Stovin

Sewer Flooding Alleviation in the Counters Creek Catchment

St Andrews Park, Uxbridge

Page 19 L.L.C. (Previously the United Salad Co. Garage) 939 SE Alder St.

Bioretention cell schematic key

Springhill Cohousing Development, Springfield Road, Stroud, Gloucestershire

Rainwise. Sustainable Drainage Solutions. Working with communities to manage rainwater. Wuppertal Court, Jarrow

Green Infrastructure and Low-Impact Development Technologies

Heron Court Rain Garden, London

Ames City Hall Campus: Stormwater Improvements

Fellgate Estate, Jarrow Surface Water Management Plan 2015

J. Paul Guyer, P.E., R.A.

Olympic Park, London. SuDS used. 1. Location. 2. Description. Case study

RAIN GARDEN ILLINOIS URBAN MANUAL PRACTICE STANDARD. (feet) CODE 897 DEFINITION

An Introduction to Sustainable Drainage

Lead Local Flood Authority SuDS Policy Statement

Opportunistic approaches to incorporating multi-functioning SuDS into housing redevelopments

Development of LID Design Guide in Edmonton

Appendix D - Technical Design Criteria for BMPs

Glencoe Elementary School Parking Lot Retrofit 825 SE 51 st Street

Selecting Appropriate Stormwater Control Measures for Your Development Project

Sustainable Stormwater Retrofit Best Practices

Melton, School SuDS scheme, Mowbray

GREEN INFRASTRUCTURE DESIGNS RAIN GARDEN

Site design measures. Chapter. This Chapter explains how site design measures can reduce the size of your project s stormwater treatment measures.

Evaluating Low Impact Development Practices for Stormwater Management on an Industrial Site in Mississippi

Ruislip green roof retrofit on a tube depot, London

SUDS: Innovation or a Tried and Tested Practice?

4.5 City of Indianapolis Stormwater Green Infrastructure Guidance: Bioretention (rain gardens) Bioretention Fact Sheet Bioretention Technical Design

Two Sides of the Green Infrastructure Coin. Jaren Hiller, PE, LEED AP Nathan Guequierre

WQ-07 INFILTRATION TRENCH

GREATER CAMBRIDGE CITY DEAL. Urban Design Guidance for Transport Infrastructure Projects

n1. Design 5.4.6a Urban Bioretention 5.4.6a Urban Bioretention Variations: Planter box, Extended tree pits, Stormwater curb extensions.

Norwood greening streets, residential retrofit, Lambeth, London

Junction of Bispham Road and Bristol Avenue, north of Blackpool town centre, Lancashire, next to the former TVR car factory.

Permeable Pavement Systems

Stormwater Management Techniques WMPF LAND USE TRAINING INSTITUTE MARCH 14, 2018

FLEET AVENUE GREEN STREET USES VACANT LOT FOR CSO REDUCTION. Thomas M. Evans, AECOM Cleveland, Ohio

6.1 Bioretention Areas

Green Infrastructure Modeling in Cincinnati Ohio. Small Scale Green Infrastructure Design Using Computer Modeling

8.0 Design and Form of Development 43/

Green Streets and Water

Patrick E. Lindemann INGHAM COUNTY DRAIN COMMISSIONER. Towar Rain Garden Drains A Low-Impact Urban Retrofit

Horsley Witten Group Sustainable Environmental Solutions. Rich Claytor, P.E. Janet Bernardo, P.E. horsleywitten.com

The Development of Urban Planning and Landscaping for Sustainable Drainage Systems

Delivering SuDS in Leicestershire Early Experiences. Wednesday 23 rd July Introduction

City of South Portland Stormwater Manual

Case Study. New San Francisco 49ers Stadium Scores Big with BioMod System. Project Overview. The BioMod Method. Design & Construction Team

CALA HO ME S WELCOME

SUSTAINABLE DRAINAGE AND LANDSCAPE MANAGEMENT PLAN FOR ROBINSWOOD PRIMARY SCHOOL

10,000 Rain Gardens Project

Wessex Water Operations Centre, Claverton Down

Rain Gardens - A Local Government Perspective

BIORETENTION CELLS. Green Infrastructure For Stormwater Management WHAT ARE BIORETENTION CELLS? WHERE ARE BIOCELLS INSTALLED?

HARDWICK GREEN, King s Lynn. Welcome to our Exhibition. What are your views? Introduction to the site and proposals. About us

Technical note. Option 3a (cyan route) Project: To: A428 Bus Enhancement Scheme. Rid Hollands, Colin Young

Low Impact Development Site Design

Green Street BMP Matrix

Appendices: Glossary. General Terms. Specific Terms. Low Impact Development Approaches Handbook

Urban Conservation Practice Physical Effects ESTABLISHMENT, GROWTH, AND HARVEST NUTRIENT MANAGEMENT

Lesson 2: Stormwater Best Management Practices (BMPs)

Small Town Sustainable Stormwater Solutions

Holnicote Multi-Objective Flood Demonstration Project Steve Rose (JBA)

SOUTH CAMBRIDGESHIRE DISTRICT COUNCIL. Planning and New Communities Director

DIVISION 32 EXTERIOR IMPROVEMENTS LANDSCAPING TREES

Title of Program: Residential Rain Garden Program Facilitator s Guide Number of Sessions: One Date of Publication: 12/2014

Green City, Clean Waters

HEALTH SCIENCES BUILDING REDEVELOPMENT PROJECT

Raingardens and Bioretention Tree Pits MAINTENANCE PLAN. EXAMPLE June 2008

Attachment 2: Permeable Pavement Design Guidelines

Inspection and Maintenance of Stormwater Best Management Practices

The "Smart City is coming: what does this mean, and can it be sustainable?

LOUISIANA STATE UNIVERSITY COMPREHENSIVE & STRATEGIC CAMPUS MASTER PLAN. APPENDIX G - Stormwater Study Findings & Stormwater Solutions

LEADING INNOVATIONS IN SUSTAINABLE URBAN DRAINAGE

Monitoring Performance and Effectiveness of Urban Stormwater Best Management Practices. Jim Duncker, USGS Kuldip Kumar, MWRDGC David Leopold, CDOT

Pollutant Removal Benefits

Notting Hill Housing & The Development Team

Low Impact Development (LID) and Bioretention Techniques

12/31/2014 County of Mendocino s Low Impact Design Standards Manual v1.0 A P P E N D I X 8. Site Design Measures. 32 P a g e

Water Sensitive Urban Design Site Development Guidelines and Practice Notes. Appendix

Grass Buffer T-1. Description. Site Selection. Designing for Maintenance

Meg Kelly Senior Manager, Space to Grow Healthy Schools Campaign

Transcription:

Greening streets, retrofit rain gardens, Nottingham SuDS used Rain gardens Benefits Proven surface water capture and infiltration leading to reduced pressure on downstream sewer and watercourse. Increased understanding and awareness of the benefits of retrofit SuDS at a community and partner level. 1. Location Ribblesdale Road, Sherwood, Nottingham, NG5 3HW. 2. Description The setting is a quiet residential road, consisting of 67 properties. A grass verge with occasional mature trees runs the entire length of the road. There is limited parking pressure with most homes having provision for off-street parking. 1

Figure 1 a and 1 b Existing road layout The road is adjacent to the Day Brook. This heavily modified watercourse has poor water quality due in part to numerous sources of urban diffuse pollution. In addition there are a total of 972 properties which fall within the Day Brook floodplain. Previous fluvial events have led to property flooding downstream. Figure 2 Ribblesdale Road and Day Brook 2

3. Scheme description This pilot retrofit SuDS project was a result of collaboration between the Environment Agency, Nottingham City Council, Groundwork Greater Nottingham and Severn Trent Water. The construction phase was completed in May 2013. The scheme was designed to achieve the following objectives: Document and evaluate the design and construction of a series of rain gardens within an existing highway setting; Maximise surface water interception, attenuation and infiltration; Test the effectiveness of rain gardens in managing surface water from the public highway; Encourage participation from local residents in the design and future management of the rain gardens; Evaluate the effectiveness of the scheme as an engagement tool around the sources of urban diffuse pollution and flood risk; Highlight the role that retrofit SuDS can play in improving the quality and reducing the volume of surface water flowing to urban watercourses. Partners contributions: Groundwork Developed the outline and detailed designs; Helped secure support for the scheme from City councilors; Worked with the Highway Design team to ensure the scheme would integrate and interact well with the existing highway layout; Managed contract negotiation and implementation of the scheme; Led community consultation and facilitated the residents liaison group. Nottingham City Council Assisted with the design and technical development of the scheme; Safety audit of rain garden design undertaken by Traffic Safety team; Oversaw rain garden construction as Highway Authority; Ongoing maintenance of the rain gardens. The Environment Agency Provided the capital funding through the Midland s MURCI Waters programme; Provided technical guidance on water quality and diffuse pollution; Lead for ongoing evaluation. 3

Severn Trent Water Built a surface water hydraulic model of the scheme; Assisting with ongoing evaluation. 4. Main SuDS used and how it works A total of 21 linear rain gardens (total of 148m 2 ) were constructed within the grass verge, allowing for the constraints of access, below ground services, street furniture and trees. The rain gardens utilise a combination of clean stone aggregate and proprietary units to create void space beneath a planted topsoil layer. They were designed to capture runoff from 5500 m 2 of highway from a total surface area of 7100 m 2. The remaining surface area could not be incorporated into the scheme due to a number of mature trees clustered in one section of Ribblesdale Road. The scheme was designed to manage surface water runoff from a 1:30 year event and to always intercept and treat the, often more polluted, first flush of highway runoff. Existing highway gullies have been retained to allow for overflow when the rain gardens reach capacity. Proprietary water attenuation cells were a key part of the initial design as they provide significantly higher void space capacity than clean stone. However, budget constrains meant that the use of proprietary cells was reduced and replaced by stone fill in a number of gardens. It is hoped that differences in the performance of the 2 different rain garden designs will be evaluated over the coming years. Figure 3 Section Drawing of the first rain garden design 4

Figure 4 Section Drawing of the second rain garden design Figure 5 Completed rain gardens (1) 5

5. Plant selection Figure 6 Completed rain gardens (2) The following plants were used in three combinations with Stipia being used throughout: Stipia arundinacea Carex evergold Miscanthus Yakushima Dwarf Festuca blue fox Plant selection for the rain gardens was influenced by the following: 1. Need for tolerance of wide fluctuations in soil moisture levels from inundation to long dry periods, exacerbated by a highly permeable growing media; 2. Provision of sufficient structure to assist pedestrian and driver differentiation between footpath, road and rain garden without blocking sight lines; 3. Use of evergreen species to reduce leaf debris in the rain gardens and the associated maintenance; 4. Aesthetics. Semi-mature plant stock was used to ensure there was sufficient plant structure from completion of the rain gardens. 6

6. Maintenance The existing and predicted maintenance regimes were reviewed prior to construction. It is expected that maintenance of the rain gardens will be limited to an annual trim of the vegetation, with occasional mulching and clearing of the inlet. As the rain gardens were constructed within existing grass verges, the reduction of grass cutting will off-set the cost of the new maintenance regime. 7. Costs Capital costs for the project were 68K. Staff time was also provided by Nottingham City Council and the Environment Agency. Groundwork s time for design and community engagement was paid for by the overall project budget. The project delivered 148m 2 of rain garden which equates to 460 per m 2. The cost for rain gardens filled with aggregate was around 300 per m 2 but was significantly more where attenuation cells were utilised. 8. Evaluation The scheme has been designed to facilitate on-going evaluation of the rain gardens. The installation of a data logger provides continuous water depth recording within the void space beneath one rain garden. The data obtained shows how the rain garden performs during and after rainfall. Variation in rain garden performance will be monitored over time. Figure 7 Water level within rain garden void following 5 rainfall events in June 2013 In addition, initial results from the InfoWorks CS 2D model of the scheme suggest a 33% reduction in the flow reaching the sewer during a 1 in 1 return period storm. Figure 8 Model output showing reduced peak in sewer flow (in red) 7

A survey of local residents was also undertakenb. The 17 residents who responded to the survey (25% response rate) have provided a mixed picture of opinions. Some residents remain incredibly supportive of the scheme and are absolutely delighted with the finished rain gardens. Others dislike the rain gardens and feel that, in particular, they have taken away parking space or created a hazard for pedestrians or cyclists. 9. Benefits Figure 9 Results of resident survey SuDS retrofit scheme delivered through partnership; Proven surface water capture and infiltration leading to reduced pressure on downstream sewer and watercourse; Increased understanding and awareness of the benefits of retrofit SuDS at a community and partner level. 10. Challenges & lessons learnt The following challenges were managed during the project; Limited time to design and construct the scheme; Varying support for the scheme amongst residents and general lack of understanding of how surface water contributes to flooding and poor water quality; Safety concerns residents and safety audit helped refine rain garden design. 8

11. The future Evaluation of the project will continue over the next twelve months. The partners will work to promote the multiple benefits of retrofit rain gardens and use the results of the pilot to influence future surface water and fluvial flood defence schemes. 12. Project details Status: Constructed, May 2013 Version: November 2013 13. Project team Project Lead and Designer: Paul Crawford, Landscape Architect, Groundwork Greater Nottingham Funding and Diffuse Pollution: John Brewington, Programme Manager, Environment Agency Highways Design and Drainage: Chris Capewell, Team Leader, Highway Design, Bridges & Drainage, Nottingham City Council Highways Design & Contract Engineer: Frank Knapp, Highways Design Engineer, Nottingham City Council Contractor: Direct Labour Organisation (DLO), Nottingham City Council 9