Service Manual This Service Manual is written for the after sail service department, especially for the fix and maintenance workers.

Similar documents
Manual No.'13 SAF-T-182. updated December 02,2013 TECHNICAL MANUAL AIR TO AIR HEAT EXCHANGE UNIT SAF150E6 250E6 350E6 500E6 650E6 800E6 1000E6

DESIGN & TECHNICAL MANUAL

Installation/Instruction Manual

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

GDDEM10 DEHUMIDIFIER

Operation Manual RANGE HOOD

Installation Instructions

Inverter Split-type Room Air Conditioner

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)

Operating Instructions

OPERATION MANUAL. Air Conditioners FXAQ20PV1 FXAQ25PV1 FXAQ32PV1 FXAQ40PV1 FXAQ50PV1 FXAQ63PV1. MODELS Wall-mounted type. English. Deutsch.

DAIKIN ROOM AIR CONDITIONER. Operation Manual

Owner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger

SYSTEM Inverter Air Conditioners

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

OWNER S MANUAL AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-B10, 13, 16, 22N3KV2 Series RAS-M07, 24N3KV2 Series

General safety precautions English

General safety precautions English

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

250mm dia straight pipe length SP4 SP3. Air volume

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Safety. Connect the product properly to the ground. (Malfunctioning or power leaks can cause electrical shock.)

OPERATION MANUAL. Wireless Remote Controller Kit

General safety precautions English

GUG-01SL-E GUG-02SL-E GUG-03SL-E

Operating Instructions

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

Smokeless Roaster Operational Manual

40E ELECTRIC FAN HEATER

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXAQ15PAV1 FXAQ20PAV1 FXAQ25PAV1 FXAQ32PAV1 FXAQ40PAV1 FXAQ50PAV1 FXAQ63PAV1

Operating Instructions Air Conditioner

LG Convertible-Type Air Conditioner

INSTALLATION MANUAL AIR CONDITIONER

Original instructions. Operation Manual & Cautions

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

Electric Patio Heater Ceiling Type. Operating Instruction. WARNING: This heater is not equipped with a device to control

Operating Instructions. Model No. EH-NE22/EH-NE11. English 7. (Household) Hair Dryer

Operating Instructions Air Conditioner

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

40E ELECTRIC FAN HEATER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Operating Instructions

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

Operating Instructions

General safety precautions English

Electric Hand dryer. Installation and operating manual

AIR CONDITIONER (SPLIT TYPE)

R410A SPLIT SERIES FIXED SPEED

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

RAV-SP181BT-UL RAV-SP241BT-UL RAV-SP301BT-UL RAV-SP361BT-UL RAV-SP421BT-UL

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

Operating Instructions Air Conditioner

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

30-pint Dehumidifier User Guide

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

SPLIT - TYPE ROOM AIR CONDITIONER

MA Remote Controller PAR-31MAA

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

Owner s Manual. Indoor Unit MMK-AP0073H2UL MMK-AP0093H2UL MMK-AP0123H2UL MMK-AP0153H2UL MMK-AP0183H2UL MMK-AP0243H2UL AIR CONDITIONER (MULTI TYPE)

OWNER S MANUAL LG CORDLESS VACUUM CLEANER

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Room Air Conditioners

General safety precautions English

SYSTEM Inverter Air Conditioners

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

Indoor Unit (2 Series)

JT-SB116JH-G-NA JT-SB116JH-W-NA

PBX series OPERATION MANUAL

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

Ionizer (Static Remover) STABLO-EX Instruction Manual

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

Air conditioner. User manual AC777KN4DCH

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Ultrasonic Aroma Diffuser AD-SD1-CE

NEXXOS INVERTER USER MANUAL

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

Model : CHB Series CHUNGHO C.A. CO., LTD. Head office / Factory Seowoon-Dong, Gyeyang-Gu, Incheon, Korea. com

SYSTEM Inverter Air Conditioners

Operating Instructions Air Conditioner

Portable Air Conditioner HSC-11

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

DEHUMIDIFIER. User Manual 50BT, 70BT

General safety precautions English

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

Owner s Manual CS

Transcription:

Service Manual This Service Manual is written for the after sail service department, especially for the fix and maintenance workers. Energy Recovery Ventilator (sold in Europe market) Model No. Panasonic Ecology Systems Guangdong Co., Ltd.

Cautions on Safety Never Fail to Observe This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. ENGLISH Children should be supervised to ensure that they do not play with the appliance. Described below are the way we are gaining your attention to what you are supposed to observe to prevent dangers to the users or other people as well as loss to the property. The degrees of danger or damage that is likely to occur due to the wrong use ignoring the indications are categorized for explanation as marked below. DANGEROUS WARNING CAUTION The column with this mark shows Impending Danger of Death or Serious Injury. The column with this mark shows Conceivable Threat of Death or Serious Injury. The column with this mark shows Likelihood of Damage or Loss to Materials only. Kinds of the items to be observed are categorized for clarification with the following pictorial symbols. (The marks described below are samples.) This pictorial indication shows Prohibited. This pictorial indication shows Forced Execution. Cautions for Operation DANGEROUS WARNING Do not use as an air circulators for open-type burners (heaters). Prohibited When gas or oil stoves are used in the home, separate equipment for circulating the air should be used. When any abnormal condition (scorching smell or others) is found, stop the operation immediately and switch the exclusive circuit breaker OFF. If you continue the operation without removing the cause, it could cause an electric shock or a fire. When the system needs a repair, consult your dealer. Don't push a finger or a stick into the air inlet or the outlet. A fan with a high rpm will injure you. Prohibited Modification of the system is strictly prohibited. Improper practice of repair could cause a water leakage, an electric shock or a fire. Disassembly Prohibited When the system needs a repair, consult your dealer. If there is a combustible gas leakage from other appliances, ventilate the room by opening windows. If operation were to be attempted in such a situation, sparking at electrical contact points could cause an explosion. Netting or something similar should be provided at the external air intake opening to prevent birds etc. interfering with the unit. Nests or other foreign objects should be removed. That could lead to a lack of oxygen in the room. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. 1 2

Cautions on Safety Never Fail to Observe Cautions for Operation ENGLISH CAUTION It is strictly prohibited to place a container of combustible gas or liquid near Energy Recovery Ventilators or to spray it directly with the gas or liquid. It could cause a fire. Prohibited Do not use outside the rated voltage. It could cause a fire or an electric shock. Prohibited This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Combustion apparatus should not be placed allowing a direct exposure to wind of Energy Recovery Ventilators. Incomplete combustion could occur on the apparatus. Prohibited Don't blow directly towards animals or plants. Prohibited Likely to cause bad effect on animals and plants. Don't put a container of water on Energy Recovery Ventilators. When water spills, it is likely to enter inside the unit and degrade electric insulation, possibly Prohibited resulting in an electric shock. Do not wash Energy Recovery Ventilators with water. It could cause an electric shock. Keep from water Do not handle switches with a wet hand. It could cause an electric shock. Don t touch with wet hands If Energy Recovery Ventilators are not used for a long period of time, switch the exclusive circuit breaker "OFF" for safety reasons. If the power is left on, any build-up of dust could cause a heat generation or a fire. ESPAÑOL ITALIANO DEUTSCH FRANÇAIS Cautions for Installation The system should never be used for any other purposes than intended such as for preservation of foods, flora and fauna, precision devices or work of art. CAUTION Don't incline Energy Recovery Ventilators when removing the unit. Otherwise, water remaining inside is likely to drop and wet the furniture or other property. NEDERLANDS It could cause deterioration of foods or other problems. Prohibited Ask the sales office or the engineering shop to perform the work. PORTUGUÊS 3 2

Specific Caution Items Checking Location of Installation This Energy Recovery Ventilators have been designed especially for use in offices, conference rooms, etc. Please check to ensure that neither the main unit nor the inlet-outlet grill are installed in any of the following locations. Locations exposed to high temperatures or direct flame. Avoid installing the Energy Recovery Ventilators or the inlet-outlet grill in locations which reach temperatures of 40 C or above. Usage under high temperature conditions may cause distortion of the filter or Heat Exchange Element or motor burn-out. 40 C Locations with high humidity. Do not install in high humidity locations such as bathrooms. Doing so may cause a breakdown of the unit or an electric shock. Locations with large amounts of oily smoke, such as food preparation areas. The unit will become inoperable if the filter or Heat Exchange Element become clogged with oil. ENGLISH Interior Intake Vent Oily smoke Make sure that Inspection Opening is provided so that filter and Heat Exchange Element maintenance and periodic spot checks of the unit can be easily carried out. (Refer to the Model Installation for its space) Do not install the unit in locations such as machinery or chemical plants where it will be exposed to noxious gases containing acids, alkali, organic solvents, paint fumes, etc., to gases containing corrosive ingredients, or where dust or oil mist will be produced. If there are any problems concerning the location or installation of the unit, please consult either store from which it was purchased or the agent who installed it. When Using Always be sure to use a filter. Failure to do so may cause dust and dirt to build up on the heat exchange element, lowering its efficiency and rendering it inoperable. Operate the switch with certainty. In particular, suddenly turning the switch on and off will not only cause improper operation of the unit, but will also affect the relay inside the switch, and may damage it. Never operate the on Normal ventilation during the winter when the room is being heated, as this will cause condensation to form inside the unit and in the inlet-outlet vent. Normal ventilation 5 3

16 4

Cautions on Safety 9 5

Specifications Item Ventilation Mode Notch Input (W) Model No. (Extra high) 112-128 108-123 87-96 (Extra high) 112-128 108-123 Air Volume (m³/h) 250 250 190 250 250 190 External Static Pressure (Pa) 105 95 45 105 95 45 Noise (db) 30.0-31.5 Heat Exchange Ventilation 29.5-30.5 23.5-26.5 FY-250ZDY8 220-240V 50Hz 30.0-31.5 Normal Ventilation 29.5-30.5 87-96 23.5-26.5 ENGLISH FRANÇAIS Temperature Exchange Efficiency(%) 75 75 77 Dimensions(mm) Weight (kg) Item Ventilation Mode Notch Input (W) Model No. (Extra high) 182-190 178-185 175-168 (Extra high) 182-190 178-185 Air Volume (m³/h) 350 350 240 350 350 240 External Static Pressure (Pa) 140 60 45 140 60 45 Noise (db) 32.5-33.0 Heat Exchange Ventilation 30.5-31.0 Width 882 Depth 599 Height 270 22.5-25.5 29 FY-350ZDY8 220-240V 50Hz 32.5-33.0 Normal Ventilation 30.5-31.0 175-168 22.5-25.5 DEUTSCH ITALIANO Temperature Exchange Efficiency(%) 75 75 78 Dimensions(mm) Weight (kg) Width 1050 Depth 804 Height 317 49 ESPAÑOL Item Ventilation Mode Notch Input (W) Model No. (Extra high) 263-289 204-225 165-185 (Extra high) 263-289 204-225 Air Volume (m³/h) 500 500 440 500 500 440 External Static Pressure (Pa) 120 60 35 120 60 35 Noise (db) 36.5-37.5 Heat Exchange Ventilation 34.5-35.5 31.0-32.5 FY-500ZDY8 220-240V 50Hz 37.5-38.5 Normal Ventilation 37.0-38.0 165-185 31.0-32.5 NEDERLANDS Temperature Exchange Efficiency(%) Dimensions(mm) Weight (kg) 75 75 76 Width 1090 Depth 904 Height 317 57 PORTUGUÊS 7 6

Specifications 7

Performance (P-Q curve) FY-250ZDY8 FY-350ZDY8 FY-500ZDY8 FY-650ZDY8 FY-800ZDY8 FY-01KZDY8A 8

Cautions for Operation EA RA EA RA 600 A OA SA 600 A OA SA Model FY-350ZDY8 and FY-500ZDY8 have two Heat Exchange Element. 8 65 20 65 A 370 (kg/kg ) 9 10

FY-250ZDY8 FY-350ZDY8 FY-500ZDY8 A H H I 2 5 6 10 9 E F G G 1 7 11 4-13 30 Oval hole K L B M 4 C J 3 C N P FY-250ZDY8 FY-350ZDY8 FY-500ZDY8 Note1) Note2) Model No.FY-350ZDY8 and FY-500ZDY8 have two Heat Exchange Element. Model No.FY-350ZDY8 and FY-500ZDY8 have different fan and motor locations. 8 FY-250ZDY8 FY-350ZDY8 FY-500ZDY8 1050 70 978 112 580 470 182 317 1090 70 1018 132 640 470 182 317 414 2 5 6 E 8 10 9 G FY-650ZDY8 FY-800ZDY8 FY-01KZDY8A A H I G F H K 1 7 11 L M 4 B J 3 N P FY-650ZDY8 FY-800ZDY8 Note1) Model No.FY-01KZDY8A has four Heat Exchange Elements. Note2) Model No.FY-650ZDY8 has different fan and motor locations. C 8 C FY-01KZDY8A FY-650ZDY8 70 620 560 FY-800ZDY8 FY-01KZDY8A 10 12

Ask a specialized electrical construction operator for advice regarding wiring in accordance with "Technical Standards for Electrical Equipment"and"Interior Wiring Regulation". Connect wires/cables indicated by broken lines. 220-240V~single phase 50Hz Operation Switch 0 (OFF) 1 (ON) Air Flow Switch (3) (1) Function Select Switch (3) Energy Recovery Ventilation (1) Normal Ventilation To find out the function of each switch, refer to Page 7 of the Owner s manual. Switch PL SW1 Common SW2 (Line) (Neutral) Second main body Main unit L (Voltage) N (Ground) SW1 SW2 Common Terminal board Brown Capacitor Orange Orange () (Extra high) () Capacitor Orange Orange () (Extra high) () Micro switch For power supply,use a VVF cable with 1.6 or 2. Take the following steps on connect wires/cables: Remove two screws fixing the cover of the electrical components box,open the cover,and connect wires/cables correctly. Secure the cable drawn from the terminal board firmly with the cable holder. If a large volume of air is requierd or a long duct is used,switch the wire connection from to Extra high according to the following steps: Remove two screws securing the cover of the electrical components box, and open the cover. In the electrical components box,change the connection of fan motor leads from to Extra high. Relay 1 Brown Relay 2 Relay 3 250ZDY8 Supply Air Fan Exhaust Air Fan Motor 13 11

Electric works 220-240V~single phase 50Hz Operation Switch 0 (OFF) 1 (ON) Air Flow Switch (3) (1) Function Select Switch (3) Energy Recovery Ventilation (1) Normal Ventilation Switch PL SW1 Common SW2 (Line) (Neutral) Main unit L N SW1 SW2 Common Terminal board Brown Relay 1 Brown Relay 2 Relay 3 Capacitor Orange Orange () (Extra high) () () Capacitor Orange () (Extra high) 350ZDY8 500ZDY8 3.5 6.0 Orange Supply Air Fan Exhaust Air Fan Motor Micro switch Second main body 220-240V~single phase 50Hz Operation Switch 0 (OFF) 1 (ON) Air Flow Switch (3) (1) Function Select Switch (3) Energy Recovery Ventilation (1) Normal Ventilation Switch PL SW1 Common SW2 (Line) (Neutral) Main unit L N SW1 SW2 Common Terminal board Brown Brown Relay 4 Relay 1 Relay 2 Relay 3 Capacitor Orange Orange Supply Air Fan () (Extra high) () Capacitor Orange Orange () (Extra high) () 650ZDY8 6.0 Micro switch Exhaust Air Fan Motor Second main body 220-240V~single phase 50Hz Operation Switch 0 (OFF) 1 (ON) Air Flow Switch (3) (1) Function Select Switch (3) Energy Recovery Ventilation (1) Normal Ventilation Switch PL SW1 Common SW2 (Line) (Neutral) Main unit L N SW1 SW2 Common Terminal board Brown Brown Relay 4 Relay 1 Relay 2 Relay 3 Capacitor Orange Orange () (Extra high) () Capacitor Orange () (Extra high) Orange () 800ZDY8 10.0 01KZDY8A 10.0 Micro switch Supply Air Fan Exhaust Air Fan Motor Second main body 14 12

Disassembly Instruction Method of remove the Heat Exchange Element and the filter Picture 1 Picture 2 1: Stop operation and cut the power supply (breaker). 1: Turn the knob (2 pieces) and the screw (1 piece) The upper picture shows model FY-500ZDY8. and remove the Inspection Cover. Picture 3 Picture 4 model No.FY-250ZDY8/350ZDY8/500ZDY8 model No.FY-650ZDY8/800ZDY8/01KZDY8A 1: Remove the Heat Exchange Element and the filter. 1: Remove the filter and the Heat Exchange Element. Note) The quantity and form of Heat Exchange Note) The quantity and form of Heat Exchange Element differ depending on the model. Element differ depending on the model. The quantity of Heat Exchange Element by Model No ELEMENT FILTER 1 FY-250ZDY8 1 2 2 FY-350ZDY8 2 2 3 FY-500ZDY8 2 2 4 FY-650ZDY8 3 2 5 FY-800ZDY8 3 2 6 FY-01KZDY8A 4 2 Note: There are differences in the form of Heat Exchange Element between N.1.3 and N.4.6. Refer to the upper picture 3 and picture 4. 13

Disassembly Instruction Method of remove the Motor Assembly FY-250ZDY8/350ZDY8/500ZDY8 Picture 5 Picture 6 1: Remove the filter and the Heat Exchange Element. 1: Pull the partition board A out to the direction Refer to the attached Method of remove the of arrow. Heat Exchange Element and the filter. 2: First remove the screw (1 piece) and then remove the Grooved Rail. Picture 7 Picture 8 1: Trun two pieces of screw on the Motor ASSY 1: Unhook the Motor ASSY. and remove the wired connector. Picture 9 Picture 10 1: Rotate the Motor ASSY around the axis. 1: Pull it out to the direction of arrow and put (Note) Actually, The color of a wheel is black. outside of product. 14

Disassembly Instruction Method of remove the Motor Assembly FY-650ZDY8/800ZDY8/01KZDY8A Picture 11 Picture 12 1: Remove the filter and the Heat Exchange Element. 1: Pull the partition board A out to the direction Refer to the attached Method of remove the of arrow. Heat Exchange Element and the filter. 2: First remove the screw (1 piece) and then remove the Grooved Rail. Picture 13 Picture 14 1: Trun 8 pieces of screw on the Motor ASSY 1: Pull it out to the direction of arrow and put and remove the wired connector. outside of product. 15

Disassembly Instruction Method of remove the parts of Electrical Equipment Picture 15 Picture 16 1: First remove the screw (2 pieces) and then remove 1: Inside of the Electrical Equipment Box. the cover of Electrical Equipment Box. Disassembly Instruction Method of remove the parts of Unit Picture 17 Picture 18 1: Remove the screw (3 piece). 1: Put outside of product. 2: Pull the Unit out to the direction of arrow 2. 16

Exploded View FY-250ZDY8,FY-800ZDY8,FY-01KZDY8A Detail A FY-250ZDY8 Detail B B Detail A FY-800ZDY8 FY-01KZDY8 Detail B (When it is FY-800ZDY8 or FY-01KZDY8A,Element is like this) 17

Exploded View FY-350ZDY8,FY-500ZDY8,FY-650ZDY8 Detail A FY-350ZDY8 B Detail B FY-500ZDY8 FY-650ZDY8 Detail B (When it is FY-650ZDY8, Element is like this) 18

Parts List FY-250ZDY8 Parts List FY-800ZDY8 FY-01KZDY8A No. Part Name Part No. Q'ty per Set Part No. Q'ty per Set Part No. 1 Nut F05070006A 2 80ZDY20251A 2 80ZDY20251A 2 2 Fan 25ZD80702A 2 80ZD80702A 2 80ZD80702A 2 3 Motor 25ZDY3M200B 2 80ZDY3M200B 2 01KZDY3M200B 2 4 Rail 25ZD80218 2 80ZD80218 2 01KZD80218 2 5 Filter 25ZD80811 2 65ZD80811 2 01KZD80811 2 6 Element 25ZD80800A 1 80ZD80800B 3 80ZD80800B 4 7 Adapter 25ZDY20220 4 80ZDY20220 4 80ZDY20220 4 8 Element Cover 15ZD80212A 1 80ZD80213A 1 80ZD80213A 1 9 Chou Bolt M5 BT50ZD60299A 2 BT50ZD60299A 2 BT50ZD60299A 2 10 Capacitor 12ESN06C2 2 DS451106Q1AA 2 DS451106Q1AA 2 11 Unit 25ZD8S400A 1 80ZD8S400A 1 01KZD8T400A 1 12 Relay AP5528F 3 AP5528F 4 AP5528F 4 13 Terminal-8P JXO-B-8P-00 1 JXO-B-8P-00 1 JXO-B-8P-00 1 Q'ty per Set No. Part Name FY-350ZDY8 FY-500ZDY8 FY-650ZDY8 Part No. Q'ty per Set Part No. Q'ty per Set Part No. 1 Nut F05070006A 2 F05070006A 2 F05070006A 2 2 Fan 50ZD80702 2 50ZD80702 2 50ZD80702 2 3 4 Motor Rail XM-350ZDY8 35ZD80218 2 2 XM-50ZDY3M200 50ZD80218 2 2 XM-65ZDY3M200D 2 65ZDY30230B 1 65ZDY30231B 1 5 Filter 35ZD80811 2 50ZD80811 2 65ZD80811 2 6 Element 15ZD80800A 2 50ZD80800A 2 65ZD80800B 2 7 Adapter 35ZD80220 4 50ZD80220 4 50ZD80220 4 8 Element Cover 35ZD80212A 1 35ZD80212A 1 65ZD80213A 1 9 Chou Bolt M5 BT50ZD60299A 2 BT50ZD60299A 2 BT50ZD60299A 2 10 Capacitor 12ESN06C2 2 DS451605Q1AA 2 DS451605Q1AA 2 11 Unit 35ZD8S400A 1 50ZD8S400A 1 65ZDY80400 1 12 Relay AP5528F 3 AP5528F 3 AP5528F 4 13 Terminal-8P JXO-B-8P-00 1 JXO-B-8P-00 1 JXO-B-8P-00 1 Q'ty per Set 19

Package Packing dimension mm Gross Model No. weight W L H Detail kg 1 FY-250ZDY8 349 1132 795 35 2 FY-350ZDY8 396 1250 1000 57 3 FY-500ZDY8 396 1290 1100 66 4 FY-650ZDY8 467 1434 1170 1080+bottom support 90mm 77 5 FY-800ZDY8 467 1552 1170 1080+bottom support 90mm 82 6 FY-01KZDY8A 467 1552 1420 1330+bottom support 90mm 98 Model No. FY-250ZDY8, FY-350ZDY8, FY-500ZDY8 20

Package Model No. FY-650ZDY8, FY-800ZDY8, FY-01KZDY8A 21

No. 1 2 3 4 5 Modified Date 2013.07.23 Modification Process Making a new version Ver.1.0-15-