SPLIT SYSTEMS SELECTION & OPTIMIZATION GUIDE

Similar documents
SR SERIES WATER SOURCE HEAT PUMP SYSTEM SELECTION AND OPTIMIZATION GUIDE

Technical Development Program

Munters Heat Exchangers

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

AHRI 920 & ASHRAE 90.1

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Air System Sizing Summary for Lobby System Project Name: Existing Lobby 04/04/2005 Prepared by: psuae

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

The ultimate fresh air solution.

THE ULTIMATE ROOFTOP SOLUTION

SHOE PALACE HUNTINGTON PARK M.200

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

HVAC Systems What the Rater Needs to Know in the Field CALCS-PLUS


SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010


D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

Technical Assignment 3 11/15/04. Executive Summary

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Summary Comparison of Simulation Program Features

3 rd Generation of VRV. The professional solution for your professional project

Designing Energy Efficient Outdoor Air Systems

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

C13-Series Engineering Guide

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

A New Dedicated Outdoor Air System with Exhaust Air heat recovery

Controls Lite. Controls Instruction, Operation, and Maintenance. IOM-C Part Number

Direct and indirect evaporative cooling

AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE

PR SERIES SELECTION AND OPTIMIZATION GUIDE

Reference Guide for Microprocessor Controller

Air System Sizing Summary for AHU/CU-1 Project Name: Wilton Manors Fire Station#16 06/26/2016 Prepared by: L.N.I.

VertiCool Aurora Engineering Guide

HCU Systems for Industrial Applications. Rob Smith National Accounts Manager March 7, 2011

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3

RT-OA TM Rooftop Outdoor-Air (DOAS)

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

Best Practices for DX Piping. Greg Drensky Jacco & Associates

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

Alarms Updated 03/26/2018

CONDENSERS AND CONDENSING UNITS

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

36,000-62,000 BTUH Nominal Capacity

Flexible & Innovative. Cooling Solutions

PHD Dolphin Installation

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

AIR CONDITIONER PERFORMANCE RATING

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Installing ProSeries 2004

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Oracle Communications Performance Intelligence Center

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

Installing ProSeries 2005

Help. Help Software Tutorial. Building a Load Sizing Project with an NH-EL Humidifier and CSD Distributor.

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Fresh Air Ventilation

Fresh Air Ventilation

Product Line Introduction. Karl Zhang Technical support engineer

Appendices. Included in this section are

RT-OA TM Rooftop Outdoor-Air (DOAS)

Energy Recovery with Cooling and Heating Model ERCH

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

THERMOSYS 4.3. Getting Started Guide

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

OPERATING INSTRUCTIONS

ELECTRICAL QUANTITY WEIGHT (LB)

TORO SENTINEL APPLICATION NOTE AN04: ACTIVITY / ALARM MONITOR

i-vu CCN 4.0 Owner s Guide

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

ENTOUCH ONE USER GUIDE

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

CoolSpot Engineering Guide

Optimisation of cooling coil performance during operation stage for improved humidity control

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

1 Air Handling Units In ICE

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

1. Packaged Variable Air Volume (VAV) Rooftop Units (RTU) with Hot Water Reheat. 2. Geothermal Heat Pump VAV Rooftop Units with Hot Water Reheat

1.0 Digital Controller

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Reference Guide for Microprocessor Controller

MECHANICAL INFRASTRUCTURE ASSESSMENT FOR VICTOR VALLEY COLLEGE

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

Liebert Mini-Mate2 1 To 8 Tons

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Advanced Installation and Configuration Instructions

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Transcription:

SPLIT SYSTEMS SELECTION & OPTIMIZATION GUIDE www.addison-hvac.com

Creating a New Project 1. Open the ACE Interface within the web browser. ACE performs best using the Google Chrome browser. Do not use Internet Explorer. 2. Click on the My Projects tab at the top of the screen. 3. Enter the Project Name in the dialog box, click New and then click Add New button to the right.

4. On the Project Information screen, confirm the Project Name and select the appropriate information for all required fields identified with a red asterisk. If the Building Size is unknown, enter 0. This will not affect the unit selection. 5. After completing the Project Information section, click the Save button at the bottom of the screen.

Adding a Unit to the Project Schedule Split System 1. Select the Product Family and Product Category from the drop-down menus. 1. Select the Product Family and Product Category from the drop-down menus. Split - Air to Air systems Split Air Source Heat Pumps 2. Select the model from the Select a Model menu. RCOA - 100% outside air model RCRA - mixed air model RCOH - 100% outside air heat pump model RCRH - mixed air heat pump model 3. Choose the quantity of this model required for the application. Quantity can be changed later in the selection process. 4. Click the Add button

Selecting the Unit Enter the unit tag referenced in the equipment schedule in the Tagging box within the Design Inputs section. 1. Leave the Unit Size set to Auto. This will allow the ACE tool to provide potential configurations that will meet the application criteria. 2. Select the Unit Voltage for both CU and AHU 3. Select the Air Volume Application. 6 Select the Cabinet options. 7. Select the Heating Type from the drop-down menu. Additional information is provided in the Heat Selections section. 8. Enter the design CFM in the Total Airflow box. On mixed air units, enter the Outside Airflow requirement in the associated box. 9. Enter the design external static pressure in the External SP box. 10. Enter the altitude of the equipment application in the Altitude box. 11. Enter the outdoor Ambient temperature and the EAT DB and EAT WB in the DX Air Cooled box 12. For heat pumps enter the Ambient (heating) design temperature and the EAT DB temperature during mechanical heat operation.

Heat Selections The heat criteria box displayed is dependent on the Heating Type selection in the Design Inputs box. - Hot water heat - skip to step 13 - Electric heat - skip to step 18 Supplemental and Auxiliary Heat When selecting additional heat sources on air source heat pumps, an understanding of the difference between supplemental and auxiliary heat is necessary. Supplemental heat is used when the mechanical heat available from the heat pump system is not sufficient to reach the desired leaving unit air temperature. In these situations, additional heat is added after the primary DX coil through the use of electric heat strips, gas heat, hot water or steam coils. On supplemental heat applications, the capacity of the additional heat source adds to the heat capacity available from the heat pump system at design conditions. When selecting a DOAS unit with supplemental heat only, leave the Auxiliary button unchecked in the ACE selection tool Electric Heat or Hot Water heat box. The EAT DB for additional heat will auto calculate based on the heat pump output within the software. On auxiliary heat applications, the capacity of the additional heat source is capable of supporting the entire heating load without heat from the heat pump system. This can serve as a redundant heat system in case of heat pump system failure or emergency heat in situations where the outdoor ambient temperature is too low for efficient heat pump heating operation. Systems equipped for auxiliary heat operation are also capable of providing supplemental heat. This is accomplished by a control defined balance point or Compressor Disable temperature. When selecting a DOAS unit with auxiliary heat, select the Auxiliary button in the ACE selection tool Electric Heat, Gas Furnace, Steam or Hot Water heat box. The EAT DB box must be changed to the design condition for auxiliary heat operation. On auxiliary heat applications, the heating design OA temperature will be below the specified unit balance point or Compressor Disable temperature. This information is often located in the equipment specifications report.

Hot Water 13. If Auxiliary heat is selected and the Calculation Method is Leaving Air Temp enter the EAT DB and Min Unit LAT (dry bulb air temperatures) in the appropriate boxes based on the equipment schedule. If Auxiliary heat is not required, the EAT DB temperature will autofill from the heat pump heating output. 14. If Auxiliary heat is selected and the Calculation Method is Capacity enter the EAT DB and Total Capacity in the appropriate boxes based on the equipment schedule. If Auxiliary heat is not required, the EAT DB temperature will autofill from the heat pump heating output.

15. If choosing Filter Method and Calculation Method is Leaving Temp enter the Entering Fluid Temp and Leaving Temp (entering and leaving fluid temperatures through the hot water coil) based on the equipment schedule. 16. If the Filter Method is Fluid Flow, enter the Fluid Flow rate in gallons per minute from the equipment schedule. 17. Select the Fluid Type from the drop-down menu.

Electric Heat 18. If Auxiliary heat is selected, enter the EAT DB and LAT DB from the equipment schedule. If Auxiliary heat is not required, the EAT DB temperature will autofill from the heat pump heating output. The applied voltage is non-adjustable and auto-filled from the Unit Voltage box in the Design Inputs section. 19. Select the kw rating and the required number of heat stages in the Stages box for the required electric heat.

Selecting the Unit (continued) 20. Click on the Edit button in the Features and Options screen on the right side. 21. Two selections must be made in the Features and Options section under the AHU and CU options. These include: - Ventilation & Controls (under AHU) - Filters (Under AHU) - Refrigeration options (under CU) The Refrigeration Controls selection has a large impact on the overall unit. Reheat and sub cooling coil combinations directly affect the Unit LAT and can only be combined in specific configurations. When selecting the combination, keep in mind that only three coil slots are available. Slot 1 = DX coil - this is non-selectable Slot 2 = Reheat coil or sub cooling coil Slot 3 = Reheat coil or empty For example, a unit is configured with reheat + sub cooling. Slot 1 would be the standard DX coil Slot 2 would be the sub cooling coil Slot 3 would be the single circuit reheat coil (On/Off or Modulating)

22. After selecting the appropriate ventilation, filters and refrigeration options, click OK to exit the screen. 23. Select Calculate

Final Selection and Comparison After making preliminary selections, the ACE Interface will provide potential units that fit the basic criteria in a Packaged and Split Systems Possible Selections screen. The initial selection criteria, airflow, cooling capacity, efficiency and heat section will determine what unit options are provided. 1. Compare the following information to the specified values on the equipment schedule and select the best match. - LAT DB/WB Coil - LAT DB/WB Unit - Total Cooling Capacity - Sensible Capacity - MCA/MFS - Cabinet size - consider options to move to a smaller cabinet that will still meet performance requirements.

2. Select the unit by clicking on the model button at the top of the grid. 3. The ACE Interface will output a selection summary based on the model chosen.

4. Click Back to Schedule to add the unit to the project grid. 5. To change the selection, click Re-Select. 6. In the Project Schedule menu, select the Price icon. 7. Select the final features and options by clicking the Edit button. 8. After selecting the final features and options, click Update Price and Save buttons in the Pricing Summary box above. 9. Click Back to Schedule to add additional units to the project. 7050 Overland Road Orlando, FL 32810 Telephone: 407.292.4400 Fax: 407.292.6178