EXAMPLE SPECIFICATION ONLY

Similar documents
1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

SECTION (09950) - WALL COVERINGS

c. Oko-Tex (European environmental health standard)

Write Walls Dry Erase Specification Data (Section 09720)

WALLCOVERINGS WALLCOVERINGS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

ARCHITECT S SPECIFICATIONS For Commercial Vinyl Wallcoverings

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

ARCHITECT S SPECIFICATIONS

chiang mai What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

ARBOR SERIES DIVISION FLEXIBLE WOOD VENEER WALLCOVERING

mason What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

Non Woven Wallcoverings with or without Crystals Installation and Maintenance Guidelines

SECTION PRESENTATION DRY ERASE WALLCOVERING

venetian plaster exclusivewallcovering Low VOC LEED IEQ 4.2 CAL 1350 & CHPS certified VINYL WALLCOVERING Fire classification

SECTION FIRE EXTINGUISHER CABINETS

SECTION PRESENTATION DRY ERASE WALLCOVERING

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Laurel Forest Punta Grasscloth

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture.

SECTION GYPSUM PLASTER

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

UNIFIED FACILITIES GUIDE SPECIFICATIONS

ARBOR SERIES WOOD WALLCOVERINGS

TYPE II WALLCOVERING. Gradient: Specify reverse hang, non-reverse hang or railroaded, 52" (132 cm) horizontal repeat, random match

Wallpaper Buying Guide

SPECIAL SPECIFICATION 2242 LATH, STUCCO AND PLASTER

Emery County Senior Center Green River 06/07

INSTALLATION INSTRUCTIONS FOR. ProTek RIGID VINYL WALLCOVERING

A. Curtains: Provide curtain fabrics with the following characteristics:

SECTION FIRE-RATED GLASS AND FRAME

Be inspired... hanging wallpaper. CONTACT US ON 0861 SHAVES OR VISIT OUR WEBSITE AT FOR A STORE NEAR YOU

SECTION PRESENTATION DRY ERASE WALLCOVERING

Madagascar Sky Blue Wallpaper

INSTALLATION INSTRUCTIONS FOR VINYL WALLCOVERING

SECTION ELECTRICAL IDENTIFICATION

Banda Cay Wallpaper. eskayel.com T South 6th Street Brooklyn, NY 11249

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Kalos Cameo Wallpaper

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

MICROVENTING AVAILABLE This product can be microvented with the Duravent process for breathability. You may specify this as an added feature.

DIVISION 10 SPECIALTIES

HP PVC-free Durable Wall Paper

Section Plaster Accessories

SECTION Overhead Coiling Doors

Porta Mural Wallpaper

SPECIAL SPECIFICATION 3687 Impermeable Liner

SECTION ENCLOSED CONTROLLERS

PRODUCT INFORMATION FOR CHARLES RUPERT DESIGNS WALLPAPERS October 2007

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

Springpoint Architects, pc SECTION Childcare Center Architect s Project No TABLE OF CONTENTS Monroe County Comm. Sch. Corp.

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

VELVET MARMORINO. Fine natural mineral lime finish

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

C08. S05. P02 P05 Decorative effects

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

TH01 Molding, Bodyside

CEILINGS BACKSPLASHES WALLS PROJECTS INSTALLATION GUIDE.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Compliance Guide 2015 NFPA 101 LIFE SAFETY CODE EXIT STAIR PATH MARKINGS. for Ecoglo Photoluminescent Markings to meet the requirements of

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE

Knauf Direct Bonding and Metal Furring

DIY Cabinet Painting Guide

Wallpaper Hanging Instructions

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

Wallcovering. Index Wide

Technical Data Sheet. Non-Woven Base: Product Information. Manufacturer. Product Name. Product Specifications

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

CertainTeed. Finishing Products. Eastern Canada

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

PART 1 GENERAL 1.01 SUMMARY

16028 September 23, 2016

Always check local building codes before doing any construction work.

MagScapes Product Guide

SECTION DRY-PIPE SPRINKLER SYSTEMS

STOP RESIN TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

SECTION (15767) - UNIT HEATERS

ADDENDUM #3. Chauncey Wilmore Senior Procurement Officer March 22, 2016 ALL PROSPECTIVE FIRMS

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

E. Luminaire: Complete lighting fixture, including ballast housing if provided.

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

A. This Section includes the following lighting control devices:

GUIDE SPECIFICATION Los Angeles World Airports SECTION TOILET COMPARTMENTS

INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)

Reference Guide for DC 333

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

MAINTENANCE SEAL MAINTENANCE PREVENTING WINDOW CONDENSATION. Kohltech.ca

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SOLI VINYL. Type II. Photo: Wallcovering Soli ACW Tequila Sunrise #14

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

RESIDENTIAL APPLIANCES DIVISION 11 - EQUIPMENT PN A

Transcription:

SECTION 097200 WALL COVERINGS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Prime Agreement, including General and Supplementary Conditions, when referenced by the Prime Agreement, and other Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Vinyl wall covering. B. Related Sections include the following: 1. Division 9 Section Interior Painting for priming wall surfaces. 1.3 SUBMITTALS A. Product Data: For each type of product indicated. Include data on physical characteristics, durability, fade resistance, and flameresistance characteristics. B. Shop Drawings: Show location and extent of each wallcovering type. Indicate pattern placement, seams and termination points. C. Samples for Verification: For each type of wall covering indicated unless the basisofdesign is provided. D. Schedule: For wall coverings. Use same designations indicated on Drawings. E. Maintenance Data: For wall coverings to include in maintenance manuals. 1.4 QUALITY ASSURANCE A. FireTestResponse Characteristics: Provide wall coverings and adhesives with the following firetestresponse characteristics as determined by testing identical products applied with identical adhesives to substrates per test method indicated below by UL or another testing and inspecting agency acceptable to authorities having jurisdiction. 1. SurfaceBurning Characteristics: As follows, per ASTM E 84: a. FlameSpread Index: 15 b. SmokeDeveloped Index: 25 WALL COVERINGS 097200 1

1.5 PROJECT CONDITIONS A. Environmental Limitations: Do not install wall coverings until spaces are enclosed and weatherproof, wet work in spaces is complete and dry, work above ceilings is complete, and ambient temperature and humidity conditions are maintained at the levels indicated for Project when occupied for its intended use. B. Lighting: Do not install wall covering until a lighting level of not less than 15 fc (160 lux) or a permanent level of lighting is provided on the surfaces to receive wall covering. C. Ventilation: Provide continuous ventilation during installation and for not less than the time recommended by wallcovering manufacturer for full drying or curing. 1.6 EXTRA MATERIALS A. Furnish extra materials described below, before installation begins, that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. 1. WallCovering Material: Fullsize units equal to 5 percent of amount of each type installed. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, products listed in Part 2 "Wall Covering Products" Article. B. Products: Subject to compliance with requirements, provide one of the products listed in Part 2 "WallCovering Products" Article. 2.2 WALLCOVERING PRODUCTS A. General: Provide rolls of each type of wall covering from the same run number or dye lot. B. Vinyl Wall Covering: 1. Basic of Design Products: a. As indicated on the finish schedule 2. Vinyl WallCovering Standards: Provide antimicrobial products complying with the following: a. CCCW408 and for Type II, MediumDuty products. WALL COVERINGS 097200 2

b. ASTM F 793 for strippable wall coverings that qualify as Category II, Decorative with Medium Serviceability products. 3. Total Weight Excluding Coatings: 20 oz. 4. Width: 54 inches (1372 mm). 5. Backing Material: Osnaburg. 6. Repeat: Random. 7. StainResistant Coating: DuPont; Tedlar/Teflon. 8. Colors, Textures, and Patterns: As indicated in drawings. 2.3 ACCESSORIES A. Adhesive: Mildewresistant, nonstaining, strippable adhesive, for use with specific wall covering and substrate application, as recommended in writing by wallcovering manufacturer, and with a VOC content of 50 g/l or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24). B. Primer/Sealer: Mildewresistant primer/sealer complying with requirements in Division 9 Section Interior Painting and recommended in writing by wallcovering manufacturer for intended substrate. C. Wall Liner: Nonwoven, synthetic underlayment and adhesive as recommended by wall covering manufacturer. D. Seam Tape: As recommended in writing by wallcovering manufacturer. E. Metal Primer: Interior ferrous metal primer complying with Division 9 Section Interior Painting. PART 3 EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with Installer present, for compliance with requirements for levelness, wall plumbness, maximum moisture content, and other conditions affecting performance of work. B. Proceed with installation only after unsatisfactory conditions have been corrected. C. Under no circumstance shall wall covering be installed on the interior surface of an exterior wall. 3.2 PREPARATION A. Comply with manufacturer's written instructions for surface preparation. B. Clean substrates of substances that could impair wall covering's bond, including mold, mildew, oil, grease, incompatible primers, dirt, and dust. WALL COVERINGS 097200 3

C. Prepare substrates to achieve a smooth, dry, clean, structurally sound surface free of flaking, unsound coatings, cracks, and defects. 1. Moisture Content: Maximum of 5 percent on new plaster, concrete, and concrete masonry units when tested with an electronic moisture meter. 2. Plaster: Allow new plaster to cure. Neutralize areas of high alkalinity. 3. Metals: If not factory primed, clean and apply metal primer. 4. Gypsum Board: Prime with primer recommended by wallcovering manufacturer. 5. Painted Surfaces: Treat areas susceptible to pigment bleeding. D. Check painted surfaces for pigment bleeding. Sand gloss, semigloss, and eggshell finishes with fine sandpaper. E. Remove hardware and hardware accessories, electrical plates and covers, light fixture trims, and similar items. F. Acclimatize wallcovering materials by removing them from packaging in the installation areas not less than 24 hours before installation. G. Install wall liner, with no gaps or overlaps, where required by wallcovering manufacturer. Form smooth wrinklefree surface for finished installation. Do not begin wallcovering installation until wall liner has dried. 3.3 INSTALLATION A. General: Comply with wallcovering manufacturers' written installation instructions applicable to products and applications indicated, except where more stringent requirements apply. B. Cut wallcovering strips in roll number sequence. Change roll numbers at partition breaks and corners. C. Install strips in same order as cut from roll. D. Install reversing every other strip. E. Install wall covering with no gaps or overlaps, no lifted or curling edges, and no visible shrinkage. F. Match pattern 72 inches (1830 mm) above the finish floor. G. Install seams vertical and plumb at least 6 inches (150 mm) from outside corners and 3 inches (75 mm) from inside corners unless a change of pattern or color exists at corner. No horizontal seams are permitted. H. Fully bond wall covering to substrate. Remove air bubbles, wrinkles, blisters, and other defects. I. Trim edges and seams for color uniformity, pattern match, and tight closure. Butt seams without any overlay or spacing between strips. WALL COVERINGS 097200 4

3.4 CLEANING A. Remove excess adhesive at finished seams, perimeter edges, and adjacent surfaces. B. Use cleaning methods recommended in writing by wallcovering manufacturer. C. Replace strips that cannot be cleaned. D. Reinstall hardware and hardware accessories, electrical plates and covers, light fixture trims, and similar items. END OF SECTION 097200 WALL COVERINGS 097200 5