PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS FOR SUGAR CANE HARVESTERS

Similar documents
FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT

Ceodeux-Fire Extinguishers Valves Technology S.A.

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

THE WORLD LEADER. in special hazard fire suppression solutions

ROTARY SPRAY HEADS CATALOGUE

Don t Compromise on Fire Safety Choose Certified Quality Products

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

Datasheet Automatic Protection System for Vehicle Engine Rooms Model: BPS

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

PRODUCT MANAGEMENT BULLETIN# 171b

TotalPac X Single interlock SUREFIRE system

Inert Gas Fire Extinguishing System

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

CHAPTER THREE SPRINKLER SYSTEM AND FM-200 AGENT SYSTEM

FIRE SUPPRESSION SYSTEM

automatic FiReFighTing SYSTeMS in PainT booths

Basic Vehicle Fire Protection Manual

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Water Mist Fire Suppression System protecting the electrically powered shredder and the ballistic separator at an MRF in Devon

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Sierra Europe Srlu Technical Specification AL5000 mobile baler

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Kiddie After Discharge Clean-Up

ATEX Cleaning System. The SpaceVac ATEX system brings our revolutionary high-level cleaning system to specialist explosive atmospheres worldwide.

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

The Amerex Advantage - Quality Experienced Innovation Made in the USA

MAC 102 : A SMALL BALER WITH BIG PERFORMANCE

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

SOLUTION CATALOG Kytola Oval Flow Oil Lubrication Monitoring System

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

TECHNICAL DATA. 319a. January 27, 2012

engineered for a higher return

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Operation and Installation Manual

How can you minimize consequential damages in case of a fire?

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

Frigoscandia Equipment GYRoCOMPACT

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

SECTION FM-200 FIRE SUPPRESSION SYSTEM

Model: 3308H 3308L 3308M. Part List US-English

CO 2 EXTINGUISHING SYSTEMS

Fire Suppression Systems. Heavy Duty Mobile Plant Protecting Your Business. Head Office: 14 Baynes Place, Chelmsford, Essex, CM1 2QX

Badger Universal Control Head

Safe installations are also cost effective installations

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

STAT X - SPECIAL HAZARD FIRE PROTECTION

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

SAFETY THE BEST FOR YOUR EQUIPMENT

WORMALD INTERNATIONAL ELECTRIC VALVE ACTUATOR

T500SL Shear / baler / logger

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Fire Protection for Manufacturing Facilities

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

APPLICATION REPORT Isomerisation This diagram is intended to be a representation and should not be viewed as an actual process flow diagram.

Agent Tanks PCL PCL PCL PCL - 600

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

swp Self-priming pump for solids handling applications

HARDEST WORKING BRAND IN THE BUSINESS

EFFICIENCY OF BALERS FOR PROCESSING SECONDARY RAW MATERIALS

CARTRIDGE EXTINGUISHER

Low Pressure INNOVATIVE FIRE PROTECTION SOLUTIONS in the. Woodworking Industry INNOVATIVE FIRE PROTECTION. VID Fire-Kill. Denmark.

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Water Mist Fire Suppression

Technical description

in-bench PITCHER rinser installation intructions

Model Series Series

What extinguishes fires without pressure peaks?

Machine needle shut-off nozzle Type SHP (high performance) spring operated

What is HI-FOG? The natural enemy of fire

QUALITY STEAM CLEANING PRODUCTS

User manual Contractor s machinery / vehicles, tooling machines and special machines

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles

CPVS PRODUCT DESCRIPTION

Ultimate Cleaning Equipment for Industrial-Strength Jobs

THE BIGGEST, SMALLEST FIREFIGHTER. CEASEFIRE MINI. Suppression System

SUPERIOR THINKING. DEEPER DIGGING. Underground Mining Fire Suppression Systems

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

Model: 3508H 3508L 3508M. Part List US-English

Ceasefire Watermist Hydrant Systems

Pressure Swing Desiccant Dryers

Climate Control System

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Twin-Agent Fire Fighting/Securing Systems Specifications

Models Series Series

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Super Class HD 4.5/32-4 S Ec

Instructions for CO 2 Cold Trap System. Part No

EXPLOSION PROTECTION MAES SAFETY PRODUCTS & SERVICES

Fire Protection for Cable Tunnels

Dräger Pac 8000 Single-Gas Detection Device

Transcription:

PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS FOR SUGAR CANE HARVESTERS

AN IDEAL ENVIRONMENT TO START A FIRE CANE HARVERTERS WORK HARD DURING HARVEST Little time for maintenance Constant use - from one field to another No tolerance for downtime ALL 3 ELEMENTS FOR A FIRE High air flow from blowers Conveyor friction Electrical short Engine heat Cane trash and organic dust PRODUCTIVITY COUNTS HARVESTER FIRES DESTROY PRODUCTIVITY Downtime during the critical harvest period Usually no backup equipment Expensive repair or replacement Repairs difficult in remote field locations Accidental crop fire - lower yields Worker injury... DON T LET THIS HAPPEN TO YOU!

INTRODUCING PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS FOR CANE HARVESTERS Automatically detects and suppress engine and mechanical fires Installs directly around the engine closer to where a fire can start Works quickly, before a fire can damage equipment Easy / Flexible installation Simple design - no electrical supply needed Highly economical

HOW IT WORKS CRITICAL ZONE TO PROTECT: ENGINE, HYDRAULICS, CONVEYOR MOTORS 2 1 1 2 3 3 FIREDETEC DUAL CHAMBER CYLINDER Mounts on the side of the harvester, in any position FIREDETEC PNEUMATIC DETECTION TUBING Weaves around and above critical risk areas - even in hard to reach places. FIREDETEC DISCHARGE TUBING AND NOZZLES Up to 10 nozzles placed above critical risk areas to instantly flood the zone with extinguishing agent and suppress the fire. PATENTED DUAL-CHAMBER CYLINDER MORE ROBUST TO WITHSTAND VIBRATIONS ALLOWS VERTICAL OR HORIZONTAL MOUNTING SUPERIOR SAFETY AND LEAK PREVENTION

Discharge outlet Pressure Switch FAST AND EFFECTIVE Quick & Easy installation directly inside engine compartments: The flexible sensor tubing is easily installed directly above and around the engine - closer to where a fire could start. When in service, the tubing is pressurized with dry nitrogen to 16 bar. The dynamics of pressurization make the tubing more reactive to heat. Early fire detection: If a fire occurs, the heat of the fire causes the pressurized sensor tube to burst at the hottest spot (approx. 170 C) Instant suppression: The sudden tube depressurization actuates the special pressure differential valve and instantly floods the entire engine compartment with FireDETEC TS55 ea extinguishing agent. The fire is quickly suppressed just moments after it began... minimizing damage and downtime. Pressure Regulator Pressure Switch Core chamber filled with pressurized gas (200 bar / 2900 psi) Outer chamber filled with liquid Sensor tube Connection - For safety, extinguishing liquid and pressurized gas are in separate chambers - When activated, the pressurized gas is released into the outer chamber forcing against a piston. - The piston pushes the liquid out through the discharge tube - A built-in pressure regulator ensures a constant and sustained discharge A MANUAL ACTUATOR CAN BE MOUNTED IN THE CABIN

HIGH ECONOMICAL 24/7 protection for about R$ 2/day Keep your harvester running in the busy harvest season - minimizes downtime for repairs Prevents need to replace expensive equipment Prevents damage to crops and other equipment PROTECTS THE MOST RISK-PRONE AREAS: ENGINE, HYDRAULICS, CONVEYOR MOTORS A COMPLETE SYSTEM SOLUTION Everything you need in one box Easy to install Easy to Maintain Pos. Qty. Description 1 1 Special IHP cylinder/valve unit (unfilled) 2 1 Tube fitting 3 1 Rubber hoses 4 1 Pressure switch (160 bar) 5 1 Pressure switch (5 bar) 6 4 Tube fitting - straight 7 5 Stainless steel pipe (1 meter) 8 4 Tube fitting - tee 9 5 Nozzle fitting - threaded elbow 10 2 Nozzle fitting - threaded tee 11 7 Spray nozzle 12 1 FireDETEC tube (black, 10m) 13 30 Screw clip for tube attachment 14 1 End of line adapter 15 1 Protection spring for sensor tubing *Mount nozzles with PTFE band

WORLDWIDE INSTALLATIONS

www.rotarex.com WORLDWIDE HEADQUARTERS 24, rue de Diekirch, BP 19 L-7505 Lintgen Luxembourg Tel.: + 352 32 78 32-1 Fax: + 352 32 78 32-854 E-mail: info@firetec.rotarex.com SOUTH AMERICA HEADQUARTERS Estr. Municipal Gov. Mario Covas, S/N 13279-411 Macuco-Valinhos Sao Paolo, Brazil Tel.: + 55 19 3518/0800 Fax: + 55 19 3869 1503 IDEAL FOR ALL VEHICLES, MACHINERY & HEAVY EQUIPMENT