Visit for more technical information and downloads.

Similar documents
EasyStart T. Installation instructions. Comfort Timer with 7-day preset capability.

EasyStart Select. Visit for more technical information and downloads. Eberspächer parking heaters

Quick start guide. Operating instructions. Installation instructions. Eberspächer parking heaters A WORLD OF COMFORT

A WORLD OF COMFORT. Quick start guide. following control units and mounting parts: Control units EasyStart Remote, 12 /24 V

Repair instructions A WORLD OF COMFORT. Spare parts list. The repair instructions are valid for the following

CALLTRONIC. Operating instructions. Telephone remote control for Eberspächer parking heaters.

OPERATING INSTRUCTIONS EASYSTART CALL

Troubleshooting and Repair Instructions. Eberspächer. The Troubleshooting and Repair Instructions are applicable to the following unit versions

A WORLD OF COMFORT. The troubleshooting and repair instructions are only valid. Heaters for petrol B 5 S 12 V

The troubleshooting and repair instructions are only valid. Heaters for petrol B 4 S 12 V B 5 S 12 V

HYDRONIC L-II Troubleshooting and Repair Instructions

Troubleshooting and Repair Instructions

Coolant Heater Thermo Top (TTC) Heavy-duty Operating Instructions Installation Instructions

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

Installation Instructions

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Installation Instructions

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

SmarTemp Control fx 2.0

Installation Instructions

OPERATING MANUAL. for the modular heat presses. Secabo TC5 SMART and TC7 SMART

Air Top 3500 Air Top 5000

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

HYDRONIC II Technical description, installation, operating and maintenance instructions.

List of Contents. 1.1 Scope and Purpose

AIRTRONIC * AIRTRONIC D4. Operating Instructions and Service Book

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

Air heater 8 L Technical description, installation, operation and maintenance instructions.

AIRTRONIC L Technical description, installation, operation and maintenance instructions.

WARNING Important Safety Information

AIRTRONIC L Technical description, installation, operation and maintenance instructions.

1. Basic safety information 3 2. Proper use 3

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

Product waste disposal - Protection of the environment:

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

Operator: Save these instructions for future use!

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

WARNING Important Safety Information

Operating instructions

BOAT HEATERS MOTORBOATS, SAILBOATS AND YACHTS BOAT HEATERS A WORLD OF COMFORT

Smart Temp. Model

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Coolant Heater Thermo Top (TTC) Operating Instructions Installation Instructions

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

D-TECT 3 IP. GJD260 IP Motion Detector

DEFA HOME. User Manual Base Unit PRO

Instruction manual. Remote control electric IR HEATER

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

SERVICE MANUAL. for Thermador Professional Series Built-in Wall Ovens. Models: PO301, POD301, PO302, POD302, PODC302, POM301, POMW301

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Infrared Wall Mount Occupancy Sensor

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

Installation Instructions

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

AUS. Devireg TM 535 Installation and user manual

Operator: Save these instructions for future use!

Installation Instructions EFS Hand Washing Station

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

REMOTE CONTROL CAR ALARM SYSTEM

TECHNICAL DESCRIPTION, INSTALLATION, OPERATING, TROUBLESHOOTING, REPAIR AND MAINTENANCE INSTRUCTIONS - HYDRONIC II 5E, HYDRONIC II.

Airtronic D2 / D4 / D4+ Operating Instructions and Service Book

PM100/PM100E PLANTER MONITOR. Operator s Manual

Engineers manual. Under counter machines

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Installation and Operation Guide for the UPS-64C Power Supply with CometFlash

WHA 3000P Hot Air Station

Installation Instructions

TECH SHEET - DO NOT DISCARD PAGE

1. CONTENTS OF PACK 2. TECHNICAL SPECIFICATIONS ... User Manual v1.1. Compatible with: ESIM264 v and up. ESIM364 all versions

Customer Operation & Installation Manual Electric Panel Heaters

CommStat 4 Controller

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

GreenCon On/Off Room Thermostat

Installation Instructions

GreenCon On/Off Room Thermostat

INSTRUCTION FOR THE USER THC V E OIL BLU

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

TCH 2000 E OPERATING MANUAL DESIGNER GLASS CONVECTOR TRT-BA-TCH2000E-TC-001-EN

QUICK USER GUIDE. Alarm Control Panel

TDS 20 R / TDS 30 R / TDS 50 R

External Wireless Sounder

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

380 SERIES REMOTE SIREN ETSA380R

D-TECT 2 IP. GJD230 IP Motion Detector

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

AXS Strikemaster Engineering Manual

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

Service manual. Riva Plus HE. M296.28SR/C System boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler

Transcription:

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation Installation instructions EasyStart Timer EN Operating instructions Quick start guide Installation instructions Control unit for Eberspächer parking heaters A WORLD OF COMFORT

Visit for more technical information and downloads. 2 Vehicle Heaters Technical Documentation Contents Chapter Chapter title Chapter contents page 1 Introduction Please read first 4 Safety instructions 4 Intended use 4 General information 4 Automatic operating time calculation 4 Ventilation operating mode 4 Installation instructions for special functions 4 Technical data 5 Order No. 5 Scope of supply 5 Can be ordered as an optional extra 5 Sketch of EasyStart Timer scope of supply 6 Sketch of optional components 6 2 Installation Installing the EasyStart Timer 7 Installing the tab connector of the EasyStart Timer lead harness 7 Timer installation sketch 8 Chamber assignment of connector housing (Item 4) and bush housing (Item 5) 8 -XS10 / -XB10 connector pin assignment table 9 Connection of bush housing to the control unit lead harness 9 Install the (optional) temperature sensor 9

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation 3 Contents 3 Startup / Configuration Initial startup 10 Configuring the EasyStart Timer 10 Opening the vehicle workshop menu 11 Selecting the settings for the standard configuration 11 Selecting the temperature units Item 2: 11 Changing the preset operating time Item 4.1: 11 Resetting to as-delivered condition Item 5: 12 Setting the language Item 8: 12 Select departure time or start time Item 10: 12 Activating or deactivating automatic operating time calculation for water heaters Item 11.1: 13 For automatic operating time calculation, copy the vehicle's engine size (cubic capacity) Item 11.2: 13 For automatic operating time calculation, enter the operating time Item 11.3: 14 4 What to do if? Possible displays in the event of a fault: 15 5 Circuit diagram EasyStart Timer connection to Hydronic, Hydronic II, Hydronic II C, Hydronic II Comfort, Hydronic M II 17 EasyStart Timer connection to Airtronic, Airtronic M, Airtronic L 18 6 Service EC Declaration of Conformity 19 Hotline 19

Visit for more technical information and downloads. 4 Vehicle Heaters Technical Documentation 1 Introduction Please read first Before you start to install the EasyStart Timer, always read through these installation instructions carefully. These installation instructions contain important information, which you need to install the EasyStart Timer. Safety instructions Danger! Always note and follow all information and notes, especially the safety instructions in this document and in the heater's technical description! Intended use The EasyStart Timer is used to select the operating mode, to set the operating time, to preselect the switching on time and to switch On / Off the heater and / or add-on unit installed in the vehicle. Please note! Improper use and use outside the specified purpose cancels all liability and warranty. General information Automatic operating time calculation To use the Automatic Operating Time Calculation function of a water heater, the optionally available temperature sensor must be used. For temperature sensor Order No. see page 5. Ventilation operating mode In ventilation mode the fan of water heaters is actuated directly by bypassing heating mode. If the symbol is not displayed the Ventilation function is not available for the heater. If you have any further questions about Ventilation mode, please dial the service telephone number see page 19. Installation instructions for special functions These installation instructions describe the standard configuration. For enhanced configuration of the EasyStart Timer and for special functions, e.g. combinations with different EasyStart control units, installation in ADR vehicles, operating the heater and additional unit, etc. refer to the Installation Instructions Plus Special Functions and Diagnosis : these can be viewed and downloaded from the Eberspächer Service portal.

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation 5 1 Introduction Technical data Operating voltage Dimensions 12 volt / 24 volt W: 82 mm, H: 37 mm, D: 12 mm allowable ambient temperature 40 C to +85 C LCD ambient temperature Order No. EasyStart Timer 12 / 24 volt 22 1000 34 15 00 The display becomes sluggish in temperatures below 10 C, i.e. the flashing sequence of the symbols is somewhat slower, the contrast becomes weaker above +70 C. Scope of supply Sketch see page 6. No. in sketch Quantity Designation 1 1 EasyStart Timer 12 / 24 volt 2 1 Bracket 3 1 Foam underlay 4 1 Connector housing, 10-pin (in the bag) 5 1 Bush housing, 10-pin (in the bag) 6 2 Contact locking devices (in the bag) 7 8 Contacts (in the bag) 8 1 Self-tapping screws (in the bag) 9 1 Template 10 1 Installation instructions 11 1 Quick start guide Can be ordered as an optional extra Sketch of optional components see page 6. No. in sketch Quantity Designation Order No. 12 1 Temperature sensor 22 1000 34 22 00 13 1 Cover 22 1000 51 41 00

Visit for more technical information and downloads. 6 Vehicle Heaters Technical Documentation 1 Introduction Sketch of EasyStart Timer scope of supply 1 2 3 10 4 5 8 7 6 11 9 Key see page 5 Sketch of optional components Please note! Key see page 5 Note on the temperature sensor: A temperature sensor is not required for air heaters. The temperature sensor that is installed in the heater and which controls the temperature inside the vehicle is also used for the EasyStart Timer temperature display. Detailed operating instructions are available to view and download from www.eberspaecher-standheizung.com/download.

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation 7 2 Installation Installing the EasyStart Timer Caution! When drilling the fixing and connection holes in the dashboard, concealed components behind it could be damaged. ÎÎ Check that the space behind the installation area is free from components. Install the EasyStart Timer in a suitable place on the dashboard, within the driver's view and connect as shown in the sketch on page 8 and the circuit diagram from page 17. Use the self-adhesive drilling template supplied to position and drill the two holes ø 6.5 mm and ø 9 mm. After drilling the holes, remove the drilling template. The foam underlay can be used if necessary to level out unevenness. To do this, pull off the protective film and stick the foam underlay onto the installation area. Then pull off the second protective film. Insert the holder with expansion plug into the drillhole ø 6.5 mm. Align the holder, if applicable, press the holder firmly onto the foam underlay. Screw the fixing screw into the expansion plug and therefore fasten the holder. Feed the lead harness from the EasyStart Timer through the drillhole ø 9 mm. Clip the EasyStart Timer into the holder. Installing the tab connector of the EasyStart Timer lead harness Plug the tab connector (1) of the EasyStart Timer lead harness into the 10-pin connector housing (For details of connector housing pin assignment see page 8 and page 9). Push the contact locking device (2) into the connector housing. Please note! When installing the connector, ensure that the locking tangs always face the middle of the connector. Only in this position to the tangs latch into the housing (see sketch).

Visit for more technical information and downloads. 8 Vehicle Heaters Technical Documentation 2 Installation Timer installation sketch Key see page 5 Chamber assignment of connector housing (Item 4) and bush housing (Item 5) (Assignment seen from the cable inlet side) -XS10 (Item 4) -XB10 (Item 5)

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation 9 2 Installation -XS10 / -XB10 connector pin assignment table Pin Signal Cable colour Cross-section 1 Terminal 30 red 0.35 mm² 2 Terminal 58 grey / black 0.22 mm 2 3 Terminal 31 brown 0.35 mm 2 4 Diagnosis blue / white 0.22 mm 2 5 DAT cable violet 0.22 mm 2 6 S+ yellow 0.35 mm 2 7 ADR brown / yellow 0.22 mm 2 8 ADR white / red 0.22 mm 2 9 Temp ( ) brown / white 0.22 mm 2 10 Temp (+) grey 0.22 mm 2 Connection of bush housing to the control unit lead harness Clip the control unit lead harness into the 10-pin bush housing; note and follow the circuit diagram. Push the contact locking device into the bush connector housing. Connect the bush housing of the control unit lead harness and the connector housing of the EasyStart Timer lead harness. Insulate and tie back any cable ends that are not needed. Install the (optional) temperature sensor Plug the connector of the (optional) room temperature sensor lead harness into the 10-pin bush housing of the control unit lead harness. For connection details, see-xs10 / -XB10 connector pin assignment table. Use the screw provided to fasten the temperature sensor inside the vehicle so that it measures the representative interior temperature. Recommendation: Install the temperature sensor in the centre console, at the level of the seats. Please note! Install the EasyStart Timer in the vehicle interior only. Do not position the temperature sensor in an area in which is exposed to direct sunlight, near the outlet vents of the vehicle or in the footwell. For circuit diagrams see from page 17. Do not insert the control unit 5 A fuse into the fuse holder until all work has been completed.

Visit for more technical information and downloads. 10 Vehicle Heaters Technical Documentation 3 startup / Configuration Initial startup For the initial startup, the following steps must be carried out one after the other. Applying the operating voltage The operating voltage is applied by inserting the 5 A fuse into the fuse holder. After applying the operating voltage INIT appears in the display. INIT Note: The timer checks which type of heater is connected and configures the Menu bar (automatic detection). Setting the time Use the or button to set the hours. Press the 06 : 00 button to confirm the setting. Use the or button to set the minutes. Press the 06 : 30 Setting the weekday button to confirm the setting. Use the or button to set the weekday. Mo. Press the button to confirm the setting. Then configure the EasyStart Timer. Configuring the EasyStart Timer The system must be configured according to its use. Please note! These installation instructions describe the standard configuration. For details of enhanced configuration of the EasyStart Timer and special functions, you can view and download the Special Functions and Diagnosis installation instructions from www. eberspaecher-standheizung.com/download.

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation 11 3 startup / Configuration Opening the vehicle workshop menu Display On, the Start display appears. Use the or button to select the symbol in the Menu bar. Mo. 10:30 Confirm the Settings menu item by pressing the button. Press the longpress button for longer than 5 sec.; the Workshop menu is displayed. Selecting the settings for the standard configuration Selecting the temperature units Item 2: Default: C Use the or button to select Item 2: and confirm by pressing the button. Use the or button to select the temperature units C or F. 2: 18 C 2: 64.4 F Press the button to confirm the selection. Changing the preset operating time Item 4.1: Default: Water heater = 30 min. / Air heater = continuous heating mode Use the or button to select Item 4.1: and confirm by pressing the button. The or button can be used to set the operating time. Operating time setting range: 10 120 min. in 1 min. increments, continuous heating mode is possible for air heaters. From the 120th min. the operating time can be extended in 5 min. increments up to 720 min. 4.1: 240 Press the button to confirm the setting.

Visit for more technical information and downloads. 12 Vehicle Heaters Technical Documentation 3 startup / Configuration Resetting to as-delivered condition Item 5: Use the or button to select Item 5. 5: Default Press the 5: Default Press the INIT button to confirm the selection. button to confirm the selection. Following the automatic detection the current time and the current weekday must be entered. Then the Start display appears. Setting the language Item 8: Default: DE Use the or button to select Item 8: and confirm by pressing the button. Use the or button to select the language DE or EN. 8: DE 8: EN Press the button to confirm the selection. Select departure time or start time Item 10: Default: Off for departure time Use the or button to select Item 10: and confirm by pressing the button. Use the or Off button for the departure time or On to select the start time. 10: Off 10: On Departure time Start time Press the button to confirm the selection. After confirming you must reset the system by removing the 5 A fuse.

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation 13 3 startup / Configuration Activating or deactivating automatic operating time calculation for water heaters Item 11.1: Default: Off Use the or button to select Item 11.1: and confirm by pressing the button. Use the or button to select Off or On. 11.1: Off 11.1: On Press the button to confirm the selection. After confirming you must reset the system by removing the 5 A fuse. Please note! Automatic operating time calculation is not possible for air heaters; if Item 11.1: is selected the following appears in the display: 11.1: -- For automatic operating time calculation, copy the vehicle's engine size (cubic capacity) Item 11.2: Default: 1800 cm 3 Use the or button to select Item 11.2: and confirm by pressing the button. Use the or button to enter the engine size in 100 cm 3 increments. Setting range: 1000 cm 3 to 4000 cm 3. 11.2: 1800 Press the button to confirm the setting. Please note! The engine size entered can be increased by 500 cm³ for a larger heat requirement. If the valve 25 2014 80 62 00 or 25 2014 80 72 00 is used in the water circuit, the engine size entered can be reduced by 500 cm³. The values for the increase or reduction in the engine size entered are only valid for cooling water circuit, whose vehicle fan heat exchanger is flowed through before the vehicle engine.

Visit for more technical information and downloads. 14 Vehicle Heaters Technical Documentation 3 startup / Configuration For automatic operating time CALCulation, enter the operating time Item 11.3: Default: 60 minutes Use the or button to select Item 11.3: and confirm by pressing the button. Use the or button to set the operating time. Setting range: 10 60 minutes. 11.3: 60 Press the button to confirm the setting. Please note! Press the button to exit the Workshop menu. If the vehicle is only used for short trips, consult the customer and reduce the maximum operating time. Carry out a function test after configuration.

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation 15 4 What to do if? Possible displays in the event of a fault: Displays Description Remedy / Workshop INIT Automatic detection is active. The timer has been disconnected from the voltage and reconnected. Wait until the automatic detection has ended, then set the time and weekday. 06 : 00 NO SIGNAL The timer has been disconnected from the voltage and reconnected. The automatic detection has ended. No communication. Set the time (hours and minutes) and the weekday. Then the Start display appears. Check and if necessary renew the heater fuse. Check the voltage supply. Check the wiring. Error 1st heater fault. Perform the heater diagnosis. Error 2nd heater fault. Perform the heater diagnosis.

Visit for more technical information and downloads. 16 Vehicle Heaters Technical Documentation 4 What to do if? Displays Description Remedy / Workshop Voltage too low. Charge the battery. Check the heater's power supply. 18:30 C Temperature sensor is defective. Check and if necessary renew the temperature sensor. Please note! If the error or fault could not be corrected, dial the service phone number on page 19.

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation 17 5 Circuit diagram Circuit diagram EasyStart Timer connection to Hydronic, Hydronic II, Hydronic II C, Hydronic II Comfort, Hydronic M II X:15 Ign (+) X:58 Light (+) -E3 c -B8 -XB10 0,5* RD 1 0,5 GYBK 2 0,5* BN 3 0,5* BUWH 4 5 6 7 8 0,22 BNWH 9 0,22 GY 10 -XS10 1 0,35 RD 2 0,22 GYBK 3 0,22 BN 4 0,22 BUWH 5 0,22 VT 6 0,35 YE 7 0,22 BNYE 8 0,22 WHRD 9 0,22 BNWH 10 0,22 GY Θ * Hydronic MII 0.75 -XB10 -XS10 22 1000 34 97 01 -E3 EasyStart Timer -B8 Temperature sensor (optional) c to the heater Cable colours RD red GY grey BK black BU blue YE yellow GN green WH white VT violet BN brown

Visit for more technical information and downloads. 18 Vehicle Heaters Technical Documentation 5 Circuit diagram Circuit diagram EasyStart Timer connection to Airtronic, Airtronic M, Airtronic L X:15 Ign (+) X:58 Light (+) 0,5 GYRD g 0,5 BNWH y -E3 c 0,5 RD 0,5 BN 0,5 BUWH -XB10 1 0,5 GYBK 2 3 4 5 6 7 8 9 10 -XS10 1 0,35 RD 2 0,22 GYBK 3 0,22 BN 4 0,22 BUWH 5 0,22 VT 6 0,35 YE 7 0,22 BNYE 8 0,22 WHRD 9 0,22 BNWH 10 0,22 GY -XB10 -XS10 22 1000 34 97 02 -E3 EasyStart Timer c to the heater g to the heater y Connect cables and insulate Cable colours RD red GY grey BK black BU blue YE yellow GN green WH white VT violet BN brown

Visit for more technical information and downloads. Vehicle Heaters Technical Documentation 19 6 Service EC Declaration of Conformity The manufacturer: BURY GmbH & Co. KG herewith declares that the EasyStart Timer unit complies with the fundamental requirements and the other relevant provisions of Directive 2004/108/EC and 2009/19/EC Annex VII, VIII. A copy of the Declaration of Conformity is available from Bury GmbH & Co. KG on request. Hotline If you have any technical questions, a problem with the EasyStart Timer or the heater, dial the following service phone number from within Germany: Hotline: 03976 2350235 Fax hotline: 01805 262624 Outside of Germany, please contact the respective Eberspächer national representative.

Visit for more technical information and downloads. Headquarters: Eberspächer Climate Control Systems GmbH & Co. KG Eberspächerstraße 24 73730 Esslingen Hotline: 03976 2350235 Fax hotline: 01805 262624 info@eberspaecher.com www.eberspaecher.com 22 1000 34 15 03 01.2014 Subject to change without notice Eberspächer Climate Control Systems GmbH & Co. KG Printed in Germany