DM1131 / DM1133 / DM1134 Manual call points

Similar documents
DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Input module, input/output module

Multi line separator module

Output module (230 V)

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Input module, input/output modules

FDOOT221, FDO221, FDT221

Radio fire detection system

Mimic display driver, LED ribbon cable

Interbases. Sinteso FDSB221, FDSB228, FDSB229

OH720, OP720, HI720, HI722

DC1192 Input /Output module

FDOOT241-9, FDOOT241-A, FDO241, FDT241

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

FDCL221-M Multi line separator module

FDOOT241-A9-Ex Multisensor fire detector

SWING radio fire detection system

DT1101A / DT1102A / DO110xA Automatic fire detectors

FDCIO223 (ES 45) Transponder

ASA linear smoke detector

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Fire control panels FC360

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

DF1101-Ex Infrared flame detector

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FDM273 Radio manual call point Mounting

Synova TM product catalog.

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

OOH740, OOHC740 Automatic fire detectors

Fire control panel for modernization

DF1151-Ex Infrared flame detector

Room thermostat with 24-hour time switch and large LCD

FDCL221-Ex Line adapter (Ex)

Frost Protection Thermostat

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Duct Temperature Sensors

DOW1171 / DCW1151 Radio fire detection system

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

FDCW241 Radio gateway Mounting

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Test units and accessories

OOH740-A9-Ex Multi-sensor fire detector

1592P01. for liquids in piping DN

FC724 Fire control panel

OOH740-A9-Ex Multisensor fire detector

FC722 Fire control panel

FC2020 Fire control panel

Room Temperature Controllers

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Fire control panels FC726 FC726-XA

FC724 Fire control panel

Electronic timeswitch

Test units and accessories

FC722 Fire control panel

Flush-mounted room thermostat

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Room Temperature Controller

XC10 Extinguishing control panels

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

FC723 Fire control panel

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Frost Units for air temperature monitoring

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

FP120-Z1 Power supply kit A (70 W) Technical Manual

Use. For 2-pipe fan coils

Room Temperature Sensors

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Call stations and extensions

FDL241-9 Linear smoke detector Mounting Commissioning

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

FS20 Fire detection system

FDCI221, FDCIO221 Input module, input/output module Technical Manual

Semi flush-mount room thermostats

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Room thermostats with LCD RDD100..

Flush-mounted room thermostats

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

RVL479. Heating Controller. for use with a partner unit

Room thermostat with Auto Timer, independent DHW

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Wall-mounted room thermostat with LCD

Room thermostat with independent DHW control

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Wireless room thermostat with LCD

Sinteso TM product catalog.

FD20 Sinteso Detector system

OH110, OP110, HI110 Automatic fire detectors

Transcription:

DM1131 / DM1133 / DM1134 Manual call points AnalogPLUS/SynoLOOP AlgoRex Synova Manual call points to the fire detection system AnalogPLUS/SynoLOOP Manual call point DM1131 with direct operation Manual call point DM1133 with indirect operation and DM1134 with direct operation Two-wire installation Control Products and Systems

Characteristics Environmental Ecologically processing Recyclable materials Electronic and synthetic material simple separable Characteristics Protected electronic Alarm indicator (LED) built-in Integrated line separator Address allocation when the call point is activated for the first time Manual call point DM1131 A protective cover FDMC291 (accessory) protects the manual call point from unintentional glass break. Protective cover Manual call point DM1133 / DM1134 Function Direct alarm actuation by pushing in the glass plate By replacing the glass plate the push button is set back and the device is ready for operation again. Application For the immediate manual actuation of an alarm For indoor and outdoor application For surface- and recess-mounted feed lines in easily accessible places A protective cover DMZ1197-AC (accessory) protects the manual call point from unintentional glass break. A seal DMZ1197-AD (accessory) protects the manual call point in wet applications. Seal Protective cover Function DM1133 Indirect alarm actuation by smashing in the glass plate and pressing the push button To replace the glass plate, open the housing door with the key. The push button must be set back before closing the door again. 2

Function DM1134 Direct alarm actuation by smashing in the glass plate To replace the glass plate, open the housing door with the key, upon closing the door the button is reset Application For the immediate manual actuation of an alarm For indoor and outdoor application, equally suited for wet, humid and dusty areas For surface- and recess-mounted feed lines in easily accessible places Installation For recess mounted feed lines, break out the break-out point in the housing bottom For surface-mounted feed lines to the DM1131, a hole must be drilled into the top or bottom of the detector housing (marking), use at max. cable gland M20 For surface-mounted feed lines to the DM1133 / DM1134 the housing is equipped with opening at the top and bottom, with sealing studs for M20 cable glands or locking plug M20 Dimensions 46.6 DM1131 87 43.2 DM1133 / DM1134 134.3 87 134.3 3

Technical data DM1131 DM1133 / DM1134 Operating voltage DC 16 28 V modulated DC 16 28 V modulated Terminal block 0.28 1.5 mm 2 0.28 1.5 mm 2 Operating temperature -25 +70 C -25 +70 C Storage temperature -30 +75 C -30 +75 C Humidity (no condensation) 95 % rel. 95 % rel. Connection factor APMK 1 1 Color red, ~RAL 3000 / blue, ~RAL 5005 yellow, ~RAL 1023 / green, ~RAL 6024 Protection category IEC 60529 with seal DMZ1197-AD IP44 red, ~RAL 3000 / blue, ~RAL 5005 yellow, ~RAL 1023 / green, ~RAL 6024 IP54 IP65 Standards EN 54-11, EN 54-17 EN 54-11, EN 54-17 Approvals VdS System compatibility DM1131 DM1133 G295030 Compatible to the AnalogPLUS/SynoLOOP fire detection system DM1134 G299069 08 0786 DM1131 Siemens Schweiz AG; Theilerstrasse 1a Technical data: see doc. 007981 DM1131 - Manual callpoint incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-11 / EN 54-17 ; 2004/108/EC (EMC): EN 50130-4 / EN 61000-6-3 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20501; DoC No.: CED-DM1131 08 0786 DM1133 Siemens Schweiz AG; Theilerstrasse 1a Technical data: see doc. 001720 DM1133 - Manual callpoint incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-11 / EN 54-17 ; 2004/108/EC (EMC): EN 50130-4 / EN 61000-6-3 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20502; DoC No.: CED-DM1133 08 0786 DM1134 Siemens Schweiz AG; Theilerstrasse 1a Technical data: see doc. 001721 DM1134 - Manual callpoint incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-11 / EN 54-17 ; 2004/108/EC (EMC): EN 50130-4 / EN 61000-6-3 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20504; DoC No.: CED-DM1134 4

Details for ordering Type Part no Designation Weight DM1131 FDMH291-R A5Q00002217 Housing red, with key 0.089 kg FDMH291-Y A5Q00004979 Housing yellow, with key 0.089 kg FDMH291-B A5Q00004980 Housing blue, with key 0.089 kg FDMH291-G A5Q00004981 Housing green, with key 0.089 kg DMA1131 A5Q00005579 Switching unit 0.045 kg Accessories FDMC291 A5Q00001644 Protective cover 0.010 kg A5Q00004478 Metal screwed cable gland M20 x 1.5 0.039 kg A5Q00004479 Back nut M20 x 1.5 0.006 kg Spare parts FDMG291 A5Q00002122 Glass 0.006 kg FDMK291 A5Q00001643 Key with cover 0.030 kg DM1133 / DM1134 DMA1192-AA BPZ:5222870001 Housing red, with glass and key 0.256 kg DMA1192-AB BPZ:5464250001 Housing blue, with glass and key 0.256 kg DMA1192-AC BPZ:5464120001 Housing yellow, with glass and key 0.256 kg DMA1192-AD BPZ:5090190001 Housing green, with glass and key 0.256 kg DMA1133D A5Q00004471 Switching unit to DM1133 0.067 kg DMA1134D A5Q00005926 Switching unit to DM1134 0.070 kg Accessories DMZ1197-AC BPZ:5223550001 Protective cover 0.012 kg DMZ1197-AD BPZ:5470680001 Seal for wet areas 0.023 kg A5Q00004478 Metal screwed cable gland M20 x 1.5 0.039 kg A5Q00006735 Locking plug red, M20 x 1.5 (1 hole) 0.007 kg A5Q00010055 Locking plug red, M20 x 1.5 (2 holes) 0.007 kg BPZ:5358470001 Sticker 'avoid electrostatic charging' 0.003 kg Spare parts DMZ1196-AC BPZ:4942050001 Glass 0.016 kg DMZ1195 BPZ:4851910001 Key 0.003 kg Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 5

Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a Tel. +41 58 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document no. 007981_o_en_-- Manual S11 / FD-C Edition 2018-03-23 Section 2 / 4