DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Similar documents
DM1131 / DM1133 / DM1134 Manual call points

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Output module (230 V)

Multi line separator module

Input module, input/output modules

Input module, input/output module

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Radio fire detection system

DT1101A / DT1102A / DO110xA Automatic fire detectors

Mimic display driver, LED ribbon cable

FDOOT221, FDO221, FDT221

DC1192 Input /Output module

Interbases. Sinteso FDSB221, FDSB228, FDSB229

OH720, OP720, HI720, HI722

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

FDCL221-M Multi line separator module

ASA linear smoke detector

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDCIO223 (ES 45) Transponder

FDOOT241-A9-Ex Multisensor fire detector

SWING radio fire detection system

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

DF1101-Ex Infrared flame detector

Fire control panels FC360

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Synova TM product catalog.

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDM273 Radio manual call point Mounting

Room thermostat with 24-hour time switch and large LCD

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FDBZ290 Air sampling smoke detection kit

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

FDBZ290 Air sampling smoke detection kit

FC2040. Fire control panel. Sinteso. FS20 series, MP6

DF1151-Ex Infrared flame detector

Frost Protection Thermostat

FT2080 Fire terminal (Touch) Mounting Installation

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

OOH740, OOHC740 Automatic fire detectors

Fire control panel for modernization

FT2080 Fire terminal (Touch) Mounting Installation

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Room Temperature Controllers

1592P01. for liquids in piping DN

Electronic timeswitch

FDCW241 Radio gateway Mounting

FDCL221-Ex Line adapter (Ex)

DOW1171 / DCW1151 Radio fire detection system

XC10 Extinguishing control panels

Duct Temperature Sensors

OOH740-A9-Ex Multisensor fire detector

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Test units and accessories

Test units and accessories

Room Temperature Controller

FC724 Fire control panel

FC724 Fire control panel

OOH740-A9-Ex Multi-sensor fire detector

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC722 Fire control panel

FC2020 Fire control panel

FDCI221, FDCIO221 Input module, input/output module Technical Manual

Call stations and extensions

Frost Units for air temperature monitoring

Flush-mounted room thermostat

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Fire control panels FC726 FC726-XA

Room thermostats with LCD RDD100..

FC723 Fire control panel

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Room thermostat with Auto Timer, independent DHW

Use. For 2-pipe fan coils

FP120-Z1 Power supply kit A (70 W) Technical Manual

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

FDL241-9 Linear smoke detector Mounting Commissioning

Semi flush-mount room thermostats

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

FC722 Fire control panel

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Room thermostat with independent DHW control

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Sinteso TM product catalog.

RVL479. Heating Controller. for use with a partner unit

Wireless room thermostat with LCD

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

OH110, OP110, HI110 Automatic fire detectors

Wall-mounted room thermostat with LCD

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Flush-mounted room thermostats

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Room Temperature Sensors

FDCL221 Line separator

FD20 Sinteso Detector system

Transcription:

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button collective/synoline600 AlgoRex Synova Manual call point to all fire detection system control units with collective/synoline600 detector evaluation Manual call point DM1101 with direct operation Manual call point DM1103 with indirect operation and DM1104 with direct operation Manual release button DM1103-L and emergency stop button DM1103-S for gas extinguishing system Two-wire installation Control Products and Systems

Characteristics Environmental Ecologically processing Recyclable materials Electronic and synthetic material simple separable Characteristics Protected electronic Alarm indicator (LED) built-in Manual call point DM1101 A protective cover FDMC291 (accessory) protects the manual call point from unintentional glass break. Protective cover Manual call point DM1103 / DM1104 Function Direct alarm actuation by pushing in the glass plate By replacing the glass plate the push button is set back and the device is ready for operation again. Application For the immediate manual actuation of an alarm For indoor and outdoor application For surface- and recess-mounted feed lines in easily accessible places A protective cover DMZ1197-AC (accessory) protects the manual call point from unintentional glass break. A seal DMZ1197-AD (accessory) protects the manual call point in wet applications. Seal Protective cover 2

Function DM1103 Indirect alarm actuation by pushing in the glass plate and pressing the push button To replace the glass plate, open the housing door with the key. The push button must be set back before closing the door again. Function DM1104 Direct alarm actuation by pushing in the glass plate To replace the glass plate, open the housing door with the key, upon closing the door the button is reset Application For the immediate manual actuation of an alarm For indoor and outdoor application, equally suited for wet, humid and dusty areas For surface- and recess-mounted feed lines in easily accessible places Manual release button DM1103-L (yellow) and emergency stop button DM1103-S (blue) A protective cover DMZ1197-AC (accessory) protects the manual release and emergency stop button from unintentional glass break. A seal DMZ1197-AD (accessory) protects the manual release and emergency stop button in wet applications. Seal Protective cover Function DM1103-L Indirect extinguishing release by pushing in the glass plate and pressing the push button To replace the glass plate, open the housing door with the key. The push button must be set back before closing the door again Function DM1103-S Indirect stop function by pushing in the glass plate and pressing the push button, as soon as the button is not any longer pressed (self reset), the stopped extinguishing release will continue. To replace the glass plate, open the housing door with the key. Application For the immediate manual actuation and for the stop function of a gas extinguishing For indoor and outdoor application, equally suited for wet, humid and dusty areas For surface- and recess-mounted feed lines in easily accessible places 3

Installation For recess mounted feed lines, break out the break-out point in the housing bottom For surface-mounted feed lines to the DM1101, a hole must be drilled into the top or bottom of the detector housing (marking), use at max. cable gland M20 For surface-mounted feed lines to the DM1103, DM1103-x / DM1104 the housing is equipped with opening at the top and bottom, with sealing studs for M20 cable glands or locking plug Dimensions DM1101 46.6 87 87 DM1103 / DM1103-L/-S / DM1104 43.2 134.3 134.3 4

Technical data DM1101 / DM1103 / DM1104 DM1101 DM1103 / DM1104 Operating voltage DC 16 26 V DC 16 26 V Max. current, permanent 60 ma 60 ma Max. pulsed current 100 ma 100 ma Terminal block 0.28 1.5 mm 2 0.28 1.5 mm 2 Operating temperature -25 +70 C -25 +70 C Storage temperature -30 +75 C -30 +75 C Humidity (no condensation) 95 % rel. 95 % rel. Connection factor KMK 1 1 Color red, ~RAL 3000 / blue, ~RAL 5005 yellow, ~RAL 1023 / green, ~RAL 6024 Protection category IEC 60529 with seal DMZ1197-AD IP44 red, ~RAL 3000 / blue, ~RAL 5005 yellow, ~RAL 1023 / green, ~RAL 6024 IP41 IP65 Standards EN 54-11 EN 54-11 Approvals VdS LPCB System compatibility DM1101 DM1103 G295036 Compatible to all fire detection system control units with collective/synoline600 detector evaluation DM1104 G299068 531j/02 08 0786 DM1101 DM1101 - Manual callpoint for use in fire detection and fire alarm systems installed in buildings. Technical data: see doc. 007980 305/2011/EU (CPR): EN 54-11 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20498; DoC No.: CED-DM1101 08 0786 DM1103 DM1103 - Manual callpoint for use in fire detection and fire alarm systems installed in buildings. Technical data: see doc. 001720 305/2011/EU (CPR): EN 54-11 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20499; DoC No.: CED-DM1103 08 0786 DM1104 DM1104 - Manual callpoint for use in fire detection and fire alarm systems installed in buildings. Technical data: see doc. 001721 305/2011/EU (CPR): EN 54-11 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20500; DoC No.: CED-DM1104 5

Details for ordering DM1101 / DM1103 / DM1104 Type Part no Designation Weight DM1101 FDMH291-R A5Q00002217 Housing red, with key 0.089 kg FDMH291-Y A5Q00004979 Housing yellow, with key 0.089 kg FDMH291-B A5Q00004980 Housing blue, with key 0.089 kg FDMH291-G A5Q00004981 Housing green, with key 0.089 kg DMA1101 A5Q00005578 Switching unit 0.045 kg Accessories FDMC291 A5Q00001644 Protective cover 0.010 kg A5Q00004478 Metal screwed cable gland M20 x 1.5 0.039 kg A5Q00004479 Back nut M20 x 1.5 0.006 kg Spare parts FDMG291 A5Q00002122 Glass 0.006 kg FDMK291 A5Q00001643 Key with cover 0.030 kg DM1103 / DM1104 DMA1192-AA BPZ:5222870001 Housing red, with glass and key 0.256 kg DMA1192-AB BPZ:5464250001 Housing blue, with glass and key 0.256 kg DMA1192-AC BPZ:5464120001 Housing yellow, with glass and key 0.256 kg DMA1192-AD BPZ:5090190001 Housing green, with glass and key 0.256 kg DMA1103D A5Q00004470 Switching unit to DM1103 0.067 kg DMA1104D A5Q00005925 Switching unit to DM1104 0.070 kg Accessories DMZ1197-AC BPZ:5223550001 Protective cover 0.012 kg DMZ1197-AD BPZ:5470680001 Seal for wet areas 0.023 kg A5Q00004478 Metal screwed cable gland M20 x 1.5 0.039 kg A5Q00006735 Locking plug red, M20 x 1.5 (1 hole) 0.007 kg A5Q00010055 Locking plug red, M20 x 1.5 (2 holes) 0.007 kg Spare parts DMZ1196-AC BPZ:4942050001 Glass 0.016 kg DMZ1195 BPZ:4851910001 Key 0.003 kg 6

Technical data DM1103-L / DM1103-S DM1103-L DM1103-S Application with AlgoRex/SIGMASYS DM1103-S Application with XC10 Operating voltage DC 16 26 V DC 16 26 V DC 5 V Max. current, permanent 60 ma 60 ma 5 ma Max. pulsed current 100 ma 100 ma Terminal block 0.28 1.5 mm 2 0.28 1.5 mm 2 Operating temperature -25 +70 C -25 +70 C Storage temperature -30 +75 C -30 +75 C Humidity (no condensation) 95 % rel. 95 % rel. Connection factor KMK 1 1 Color yellow, ~RAL 1023 blue, ~RAL 5005 Protection category IEC 60529 with seal DMZ1197-AD IP41 IP65 IP41 IP65 Standards EN12094-3 EN12094-3 Approvals VdS G206029 G206030 System compatibility Compatible to all fire detection systems with gas extinguishing 06 0786 DM1103-L DM1103-L - Electrical triggering device for use in fire detection and fire alarm systems installed in buildings. Technical data: see doc. 009370 305/2011/EU (CPR): EN 12094-3 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20217; DoC No.: CED-DM1103-L 06 0786 DM1103-S DM1103-S - Electrical stop device for use in fire detection and fire alarm systems installed in buildings Technical data: see doc. 009370 305/2011/EU (CPR): EN 12094-3 ; 2004/108/EC (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 Declared performance and conformity can be seen in the Declaration of Performance and the EC Declaration of Conformity, which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-20218; DoC No.: CED-DM1103-S 7

Details for ordering DM1103-L / DM1103-S MANUAL RELEASE complete for gas extinguishing system EMERGENCY STOP complete for gas extinguishing system Type Part no Designation Weight DM1103-L A5Q00017630 Housing yellow DMA1192-AC, switching 0.344 kg unit DMA1103D (lock in), inscription plate MANUAL RELEASE gas extinguishing system, 2 locking plugs M20 x 1.5 (2 holes) DM1103-S A5Q00014486 Housing blue DMA1192-AB, switching 0.350 kg unit spec. (self reset), inscription plate EMERGENCY STOP gas extinguishing system, 2 locking plugs M20 x 1.5 (2 holes) Accessories DMZ1197-AC BPZ:5223550001 Protective cover 0.012 kg DMZ1197-AD BPZ:5470680001 Seal for wet areas 0.023 kg A5Q00004478 Metal screwed cable gland M20 x 1.5 0.039 kg A5Q00010055 Locking plug red, M20 x 1.5 (2 holes) 0.007 kg Spare parts DMZ1196-AC BPZ:4942050001 Glass 0.016 kg DMZ1195 BPZ:4851910001 Key 0.003 kg Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a Tel. +41 58 724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2015 Technical specifcations and availability subject to change without notice. Document no. 007980_s_en_-- Manual S11 / FD-C Edition 2018-05-09 Section 2 / 3