Residential-Use Lossnay

Similar documents
LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system.

Whole Home Heat Recovery Ventilation

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

Lossnay RVX Fresh Series Air Ventilation

250mm dia straight pipe length SP4 SP3. Air volume

Ventilation. Product Information

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.

GUG-01SL-E GUG-02SL-E GUG-03SL-E

Installation Instructions

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product.

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Air Conditioner. User manual. Wired remote controller MWR-WE11N

GUG-01SL-E GUG-02SL-E GUG-03SL-E

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements.

Central Heating and Ventilation

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

Evolution Control. Zone Control Homeowner s Guide

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

Fresh Air Ventilation

Fresh Air Ventilation

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

Heat Recovery Ventilation

READ AND SAVE THESE INSTRUCTIONS

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay

MA Remote Controller PAR-31MAA

Lossnay. Total Heat Exchangers

Operating Instructions

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

PEH-8,10WYB. Air-Conditioners INDOOR UNIT. For use with R410A OPERATION MANUAL

5) Do not start or stop the unit by inserting or pulling out the power plug.

Owner s Manual CS

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

ENG. IDEO 325 Ecowatt. Installation Manual

Owner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Air Conditioner CONTENTS

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

CONTENTS. Lossnay Unit

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR

MECHANICAL VENTILATION

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y...

Limited Lifetime core warranty. 5-year warranty on balance of unit.

Ducted Air Conditioning

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

Air to Air Heat Exchanger

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

NEXXOS INVERTER USER MANUAL

VEX100 series Air handling units with cross-flow heat exchanger

Register your product and get support at. AC4006. User manual

CAUTION. Installation Manual

WIRED REMOTE CONTROLLER

GUG-01SL-E GUG-02SL-E GUG-03SL-E

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

with a Breath of Fresh Air

Air-Conditioners. Indoor unit PSA-RP KA OPERATION MANUAL. English


Ducted Air Conditioning

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

Homeowner s Guide / 1

Lossnay. Total Heat Exchangers

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

Bosch Split-Type Ductless Air Conditioner / Heat Pump

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Inverter Wall Mounted Series

Operating Instructions High-spec Wired Remote Controller

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

PEA-RP140,170,200 WJA

OPERATING MANUAL UTY-RNNYM P/N English

KOMFORT EC DB Suspended heat recovery air handling units

Transcription:

HEAT RECOVERY VENTILATORS Residential-Use Lossnay Heat Recovery Ventilators Decentralized/Centralized

Lossnay optimizes residential indoor-air quality through Lossnay is a total heat-exchange ventilation system that utilizes the characteristics of corrugated design for superior temperature (sensible heat) and humidity (latent heat) exchange.* Heat exchange concept applying the Lossnay core Outside Inside Outside exhaust-air outlet (EA) Inside return-air (RA) Outside-air intake (OA) Inside supply-air (SA) After introduction of the first-generation Lossnay in 970, Mitsubishi Electric ventilators have evolved by always being one-step ahead of the air-conditioning needs of the s, which continue to diversify even today. This original technology is now used in a wide range of applications, and our ventilation systems can be found in residences, office buildings, hospitals, schools, etc. *VL-220CZGV-E is a laten heat exchanger for centralized ventilation systems.

temperature and humidity exchange The need for ventilation The need for fresh air Poor air quality can be attributed to many problems arising in the workplace and in the home. It is believed to contribute to a significant loss in productivity, low morale and higher rates of sickness. Providing good ventilation in residential and commercial buildings is to provide conditions under which people can live and work comfortably and safely. The need for appropriate humidity management In general, viruses are found to be active and the survival rate high in low-humidity, dry environments. During the winter, keeping the appropriate humidity and heating tempe rature can help prevent viruses. 0 Effect occurs by oxygen concentration Oxygen concentration (%) 5 0 5 20 Normal air concentration 2% Activity range of microorganisms vs. humidity General appropriate humidity range Size of energy Bacteria Virus No danger of risking life in a normal pressure, however it may increase carbon monoxide with combustion appliance 9~20% Mold General oxygen concentration when exhalating Breathing/pulse increases headache, nausea, and dizziness 6% 2~6% Mite 0 20 0 40 50 60 70 80 90 Humidity (%) [ Image ] Combustion appliance stops burning 5% Danger of risking life in a short term 2% Causing death 7% What can be improved by introducing Lossnay? Comfort air supply Air similar to the conditions of heated indoor-air is supplied. Supply-air 8.2 C Exhaust-air Room air Outdoor-air Air conditioner 20.5 C 5.0 C Heat recovery calculation Indoor supply-air Indoor = _ Outdoor temperature (ºC) temperature (ºC) temperature (ºC) efficiency (%) Calculation example : 8.2ºC=(20.5ºC _ 5.0ºC) 85%+5.0ºC *The above applies to the case of VL-50(E)S2-E at low fan speed in 20V 50Hz. Temp recovery + Outdoor temperature (ºC) 2

Decentralized Ventilation Solution Install wall-mouted Lossnays in each room. The heat recovery system provides fresh air at a comfortable air temperature. Total heat exchangers effectively reduce heat loss. 2F VL-50(E)S2-E bed room bed room bed room down bath room F porch dining room up living room toilet kitchen VL-00(E)U5-E 2F Model: VL-50(E)S2-E F Model: VL-00(E)U5-E Air Management CLEAN COMFO Ventilation and clean, fresh air contribute to a heated living environment. Heat recovery ventilation operation assure a comfor

Centralized Ventilation Solution One Lossnay unit provides 24-hour ventilation for the entire house, from living room and bedrooms to the bathroom. The heat recovery system provides fresh air at a comfortable air temperature. Sensible heat exchangers effectively reduce excess humidity in the winter. OA EA 2F bed room bed room RA SA bed room down bath room F porch dining room up living room toilet kitchen Model: VL-220CZGV-E Solutions RTABLE and low-noise table indoor environment. ENERGY-SAVING A highly efficient motor consumes less energy. Heat recovery ventilators also help to reduce the load on air-conditioning systems. 4

Decentralized ventilation: VL-50(E)S2-E and VL-00(E)U5-E Product Merit Air supplied and Exhausted Simultaneously Supply and exhaust air simultaneously while transferring the heat. SA RA OA EA Energy Efficient - Total heat exchanger minimizes heat loss - Achieve over 80%* temperature efficiency *VL-00(E)U5-E at low fan speed in 20V 50Hz *VL-50(E)S2-E at low fan speed in 20V 50Hz Low-Noise Operation The low operating noise is good for bedrooms and children s rooms. RA Phone ringing Sound Insulation A sound insulation effect reduces noise generated outside. Normal conversation Moderate Loud Whisper Faint Quiet On the train In the library 5dB* 25dB* VL-50(E)S2-E VL-00(E)U5-E *Condition: 50Hz, 20V, low fan speed Sound of leaves Product Features Stylish Design Match any interior décor to create a comfortable room. Sound source Average sound pressure db Indoors Average sound pressure db Difference Sound insulation effect 0.4 6.2 40.2 *Tested based on VL-08S2-AE *Measured by average sound pressure level of more than 0dB in 500Hz according to JIS A 46. VL-08S2-AE is Japanese dedicated model with equivalent features of VL-50(E)S2-E. VL-50(E)S2-E VL-00(E)U5-E Easy Maintenance The only maintenance required is cleaning the outside-air filter and exhaust-air filter. Filters are easily accessible, making quick and thorough cleaning possible. Outside air filter Lossnay Core (Heat exchanger) Core handle Exhaust air filter Exhaust air filter Lossnay Core (Heat exchanger) VL-50(E)S2-E Outside air filter VL-00(E)U5-E Flexible Installation (only VL-50(E)S2-E) Not only horizontal installation, but also vertical installation is possible, making it easy to adapt to most types of rooms. Horizontal Installation Vertical Installation Example 5

Centralized ventilation: VL-220CZGV-E Product Merit Newly Developed Heat Exchanger During ventilation, Lossnay recovers warmth in the winter and keeps air cool in the summer. Reduces heating and cooling loads with a maximum exchange efficiency of 86%*. Normal Square Heat Exchanger Simple structure contributes to minimize pressure loss and reduce power consumption. New Diamond Heat Exchanger Due to the diamond design, air passages are longer and help realize higher exchange efficiency. Wider Length Energy Efficient The highest energy-saving performance in its class. (8.5W* minimum input power) Saves heating and cooling costs by minimizing energy loss that occurs during ventilation. Quiet At an ultraquiet 4dB*, it is the quietest product in its class. Blocks outside noise for a more comfortable indoor environment. * Product Features Fan Speed Precise Adjustment Function Each main fan speed value can be further adjusted slightly. Use the PZ-6DR-E remote controller to adjust the speed. ) Considering the total hours of Lossnay operation (filter clogging), the fan power can be adjusted automatically after a given period of. 2) After the unit is installed, when the air volume is slightly lower or higher than the desired airflow, it is possible to make a fine adjustment. ( 4 is available only down and 2 down) Multi-ventilation(power supply and exhaust) Mode This mode allows the air supply/exhaust balance to be varied dynamically. The supply/exhaust balance can be selected to suit the usage environment. Relax Adjust the indoor pressure balance if a separate exhaust is installed Static pressure P-Q curve image Increase indoor pressure to prevent unfiltered drafts from coming in 2 Air volume Nomal Mode Power Supply Mode Power Exhaust Mode Keep steam inside of the shower room +2 + Original - -2 4 Prevent odors from spreading Weekly Timer Operation patterns for each day of the week. ON/OFF and airflow can be set using the weekly r function (up to eight zones per day). This function contributes to enhanced energy-saving operation. Monday to Friday 0:00 5:00 8:00 7:00 9:00 2:00 2:59 4 Saturday sleeping breakfast go to working place dinner shower 2:00 sleeping 0:00 8:00 0:00 :00 :00 22:00 2:59 2 4 Sunday sleeping breakfast relax lunch shopping shower sleeping 0:00 8:00 0:00 :00 :00 7:00 9:00 2:00 2:59 2 4 sleeping breakfast relax lunch go out in the family dinner shower sleeping *Example for reference only. 6

Decentralized ventilation Model: VL-50S2-E(Pull-Switch Model), VL-50ES2-E(Wall-Switch Model) Dimensions Model VL-50(E)S2-E Electrical power supply 220V/50Hz 20V/50Hz 240V/50Hz 220V/60Hz High Low High Low High Low High Low Air volume (m /h) 5 5 52.5 6 54 7 54 7 Power consumption (W)9 9 4 20 4.5 2 5 2 5.5 Temperature exchange efficiency (%) 70 86 69 85 68 84 68 84 Noise (db) 6.5 4 7 5 7.5 5.5 7.5 5.5 Weight (kg) 6.2 Specific energy consumption class C *Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628) on shutter knob open position. Mounting plate temporary a Hachment hole position Edge of main unit Mounting holes 5 6 Air intake/exhaust hole 20 wall hole (Left : exhaust, Right : intake) 25 0min from nearest obstruction Air intake/exhaust hole Indoor-air exhaust (Left : exhaust, Right : intake) Fresh-air supply 40.5 Pitch 20x8=60 200 00 20.5 84 (522) 60min from nearest obstruction 245 26 Indoor-air exhaust Terminal block 26.5 9.5 2 Power and connection cable pullout area (6) 0.5 (82) 9min from nearest obstruction 82min from nearest obstruction 4 97.6 Outer dia 96 Outer dia Shutter knob position (40) Open position Exhaust only position Closed position Outside-air intake 80 : VL-50S2-E : VL-50ES2-E Outside-air intake 60 56 Exhaust to outside 40 Indoor-air 28 58.5 Indoor-air exhaust exhaust Wall thickness 522 68 50 to 650 09 About 400 08 4 x 8.5 mounting holes B (Knocking hole) 5 0 4 x 5 mounting holes A Unit (mm) Model: VL-00U5-E(Pull-Switch Model), VL-00EU5-E(Wall-Switch Model) Dimensions Model VL-00(E)U5-E Electrical power supply 220V/50Hz 20V/50Hz 240V/50Hz 220V/60Hz High Low High Low High Low High Low Air volume (m /h) 00 55 05 60 06 6 0 57 Power consumption (W) 0 5 4 7 4 7 Temperature exchange efficiency (%) 7 80 7 80 72 79 7 80 Noise (db) 6.5 24 7 25 8 27 8 25 Weight (kg) 7.5 Specific energy consumption class B *Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628) on shutter knob open position. Terminal block Require to be secured Edge of main unit 420 Mounting plate Mounting holes 6 6 97 87 95.5 (Adjust (Adjust 75 able) 200 (min) 75 able) Power cord hole 50 (max) Air exhaust hole 267.5 292 85 to 90 wall hole 50 22 554 620 60min from nearest obstruction 60min 25 Indoor-air exhaust 40 (Adjustable) 25 5 Front panel (Open position) Front panel (Closed position) 9 95 08 2 Pitch 20x0=200.5 28.5 265 Air intake hole 85 to 90 wall hole 8min from nearest obstruction 2min Outer dia 75 2 : VL-00U5-E : VL-00EU5-E Outer dia 79 2 Front panel louver (Vertical position) 5 50 Fresh-air supply 252 90 40 75 Shutter knob 620 (Open position) Shutter knob (Closed position) Front panel louver (Horizontal position) 22 7 54 Wall thickness 226 200 50 to 550 06 Unit (mm) 7

Centralized ventilation Model: VL-220CZGV-E Model Characteristic Curve VL-220CZGV-E Electrical power supply 220-240V/50Hz 220V/60Hz Ventilation mode Heat recovery mode 4 2 Running current 0.60 0.29 0.8 0. Input power (W) 80 5 8.5 8.5 Air volume (m /h) 20 65 20 65 (L/s) 64 46 8 External static pressure (Pa) 64 84 44 Temperature exchange efficiency (%) 82.0 84.0 85.0 86.0 Noise (db).0 25.0 9.0 4.0 Weight (kg) Specific energy consumption class A *Figures in the chart is measured according to Japan Industrial Standard (JIS B 8628). Characteristic Curves are measured by chamber method. 400 25mm dia straight pipe length 90 5m 25m Static pressure (Pa) 00 200 00 Temperature exchange efficiency 4 2 5m 80 70 60 Exchange efficiency (%) Dimensions 4 9 Power-supply cable opening Ceiling suspension fixture 27 229 Duct connecting flange (SA) SA (Supply air) EA (Exhaust air) Duct connecting flange (EA) 0 50 0 00 200 00 400 (m /h) 0 20 40 60 80 00 Air volume 885 8 5 74 9 Drain outlet 720 775(Ceiling suspension fixture) 85 Exhaust-air filter case 8 848(Ceiling suspension fixture) 20 6 (L/s) 80 24 46 24 98 20 62 RA (Return air) 850 OA (Outdoor air) 99 86 295 Duct connecting flange (RA) Auxiliary fixture Duct connecting flange (OA) Drain pan Supply-air filter case Unit (mm) 8

Remote controller for VL-220CZGV-E Model: PZ-6DR-E 20 20 9 Unit:mm Operation panel 6 5 Lossnay 4 2 Function buttons Display section 7 7 9 8 Fan 8 Auto Mode 4 0 4 * 9 0 2:00 Sun 5 6 2 Press to turn ON/OFF the Lossnay ventilator. 2 Press to save the setting. Press to return to the previous screen. 4 Press to bring up the Main menu. 5 Operation settings will appear. When the backlight is off, pressing any button turns the backlight on and it will stay lit for a certain period of depending on the screen. 6 This lamp lights up in green while the ventilator is in operation. It blinks while the remote controller is starting up or when there is an error. 7 Main menu : Press to move the cursor down. 8 Main display : Press to change the fan speed. Main menu : Press to move the cursor up. 9 Main display : Press to change the ventilation mode. Main menu : Press to go to the previous screen. 0 Main menu : Press to go to the next screen. Lossnay is always displayed. 2 Current appears here setting appears here. 4 Functions of the corresponding buttons appear here. * The mode appears only when the optional motorized damper (P-DUE-E) is used. 5 Indicates when filter needs maintenance. 6 Appears when the buttons are locked and/or a fan speed is skipped. 7 Appears when the On/Off r, or Auto-off r function is enabled. 8 Appears when the Weekly r is enabled. 9 Appears when performing operation to protect the equipment. 0 Indicates the ventilation mode setting. * The mode appears only when the optional motorized damper (P-DUE-E) is used. Model: PZ-4SMF-E Displayed the ventilation mode status. Heat exchange By-pass 70 20 Lower case 5 Unit:mm 2 4 8 9 5 6 7 0 2 Automatic (HEAT EX./BY-PASS) or * The mode appears only when the optional motorized damper (P-DUE-E) is used. 2 Displayed while the Lossnay remote controller is on. Displayed on-r or off-r duration. 4 When a button is pressed for a function which the Lossnay unit cannot perform, this display flashes concurrently while displaying the function. 5 Displayed the selected fan speed. 6 Displayed together with the malfunctioning unit ( digits) and an error code (4 digits). 7 Displayed when the accumulated operating reaches at the set for filter maintenance. 8 Used to select the ventilation mode among heat exchange, by-pass or automatic. * The mode can be switched only when the optional motorized damper (P-DUE-E) is used. 9 Increases 0:0 when pressed once. Keep pressing the button for fast-forwarding. 0 Switch for start and stop. On during operation. Flashes when a malfunction occurs. 2 Used to select the fan speed either Low or High. Low High Note: if this button is pressed when trying to switch the fan speed of a Lossnay unit which is not equipped with the fan speed adjustment, the fan speed display and NOT AVAILABLE display flash and the unit s fan speed does not change. Press twice to reset the filter sign display. 9 Function PZ-6DR-E PZ-4SMF-E (Communicating Mode) VL-220CZGV-E VL-220CZGV-E selection 4 fan speeds 2 of 4 fan speeds Ventilation mode selection Heat recovery / Bypass / Auto (available with optional parts P-DUE-E) Heat recovery / Bypass / Auto (available with optional parts P-DUE-E) Night-purge () No No Night-purge (fan speed) No No Function setting from RC Yes No Bypass temp. free setting Yes (available with optional parts P-DUE-E) No Heater-On temp. free setting No No Fan power change after installation Yes No On/Off r Yes Yes Auto-Off r Yes No Weekly r Yes No Operation restrictions Yes (On/Off, ventilation mode, fan speed) (ventilation mode is available with optional parts P-DUE-E) No Operation restrictions (fan speed skip setting) Yes No Screen contrast adjustment Yes No Language selection Yes (8 languages) No (English Only) Initializing remote controller Yes No Filter cleaning sign Yes Yes Lossnay core cleaning sign No No Error indication Yes Yes Error history Yes No

Optional Parts Optional Parts for VL-00(E)U5-E Filter and Extension Pipe Type High Efficiency filter Replacement filter Extension pipe Extension pipe coupling Design Model P-00HF5-E P-00F5-E P-00P-E P-00PJ-E Feature Upgrated high-performance filter. Standard grade replacement filter. Total length when connected to the pipe extension coupling is 00mm. Screw-in method Optional Parts for VL-220CZGV-E Bypass damper Model: P-DUE-E 8 9 60 44 7 9 57 200 40 24 08 52 25 2-.5 Mounting bracket mounting hole 2-.5 Mounting bracket mounting hole 4 4-.5 Duct connecting flange mounting hole 25 25 20 Unit (mm) Filter Type High Efficiency Supply Air filter Medium Efficiency Exhaust Air Filter Standard Replacement Filter Design Model P-220SHF-E P-220EMF-E P-220F-E Classification (EN779:202) M6 G4 G 0

Eco Changes is the Mitsubishi Electric Group s environmental statement, and expresses the Group s stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society. HEAD OFFICE : TOKYO BLDG., 2-7- MARUNOUCHI, CHIYODA-KU, TOKYO 00-80, JAPAN www.mitsubishielectric.com Y6-007 Dec.206(MEE)