HEAT RECOVERY VENTILATOR

Similar documents
ENERGY RECOVERY VENTILATOR

Indoor Air Quality Product Brochure.

TECHNICAL SPECIFICATIONS

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Indoor Air Quality Product Brochure.

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Residential Heat & Energy Recovery

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

Limited Lifetime core warranty. 5-year warranty on balance of unit.

WALL CONTROLS MAIN CONTROLS

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

Heat Recovery Ventilators (HRVs) Flexibility. in Perfect Form. Improving indoor air quality through better ventilation

Product Data HRV A10299

FOR MODELS: VENMAR 1.3, 1.8 & 2.6 HE VENMAR 3055 & 5585 COMPACT vänee 1000, 2000 & 3000 HE

Heat Recovery Ventilators models:

WALL CONTROLS MAIN CONTROLS

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

Novofit 2.0 (Part no )

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

INSTALLATION GUIDE VB0180 VB0148

READ AND SAVE THESE INSTRUCTIONS

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

The best way to enhance indoor air quality

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

HEAT RECOVERY VENTILATORS MODELS AVS E15 ECM HRV, AVS E15 HRV, AVS E10 HRV AND ENERGY RECOVERY VENTILATOR MODEL AVS E15 ECM ERV

Product Data. ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators

Product Data A05229 A05330 HRV

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

10-year industry best core warranty. 5-year warranty on balance of unit.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Ventilation Solutions IAQ Canada

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for

IAQ VENTILATION SOLUTIONS

TR Series - The Ultimate ERV

Ventilation Solutions IAQ Canada

VENTILATION SYSTEMS. Model Numbers HRV-150 HRV-210 ERV-150 ERV-210

CATALOGUE Setting a new standard for energy efficient, clean air homes.

INSTALLATION GUIDE FOR VENMAR AVS UNIT CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV

Product Catalog Commercial Solutions US Edition

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

Product Data VA3B VB5B VC5B. Heat Recovery Ventilators

Heat or Energy Recovery Ventilation System

Product Catalog Commercial Solutions US Edition

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

Energy Recovery Ventilators

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

INSTALLER AND USER MANUAL VENTILATION SYSTEM

INSTALLATION GUIDE FOR AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, HRV 90H-V ECM AND 90H-V UNITS

INSTALLATION GUIDE FOR VENMAR AVS CONSTRUCTO 1.5* AND CONSTRUCTO 2.0

BETTER AIR. BETTER LIFE.

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

Put the V back in HVAC

Outside Air Requirements... SOLVED!

COMMERCIAL VENTILATION

MODELS LT15 & LT20 INSTALLATION INSTRUCTION FOR HEAT RECOVERY VENTILATOR (HRV)

Residential Balanced Ventilation Systems

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

VENMAR AVS INSTALLATION GUIDE AVS E15 ECM ERV* AVS E15 ECM HRV* AVS E15 HRV AVS E10 HRV 90H-V ECM ERV* 90H-V ECM HRV* 90H-V+ 60H-V+ VÄNEE

INSTALLATION GUIDE FOR VENMAR AVS UNITS CONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERV

Installation Instructions

NU800, NU1200 & NU1600

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

VERTICAL FAN COIL UNITS

SAFETY AND INSTALLATION MANUAL MODEL 8100

Operation and Installation Manual. Models 330ERV 530ERV 730ERV 1230ERV. Commercial Energy Recovery Ventilators (ERV) 69-ComERV

Glass Canopy Wall-Mount Hood

COMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

IAQ VENTILATION SOLUTIONS

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

ClalrlTech INNOVATIONS. ClairiTech. 120 Hybrid. Installation and Operations Manual Model: H-120 Rev: 1.4

MiniCore Ventilator (500, 1000) Series Engineering Guide

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

INSTALLER MANUAL RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS

Product Data HRVCCLHU HRVCCSVC HRVCCLVU. Heat Recovery Ventilators FEATURES

KHP Models. KHP Series. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

HRVBBLHU HRVBBSVC HRVBBLVU

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Heat Recovery Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

INSTALLATION MANUAL MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY

PA 500/1100V Ultra Quiet Ventilation Fan

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Total Recovery for ALL Climates Models TR & TRC

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Transcription:

HEAT RECOVERY VENTILATOR CONSTRUCTO 1.0 HRV Part no. 41502 (TOP PORTS) Part no. 41500 (SIDE PORTS) 39 to 98 CFM (0.4 in. w.g.) VB0069 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT! Configured with factory built vertical or horizontal ports, the AVS Constructo 1.0 HRV is the most versatile 98-cfm unit available on the market today. Among its exclusive features, this unit is equipped with integrated balancing and backdraft dampers in its exhaust to outside and fresh air supply ports. For a standard installation, there is no need to balance the unit*, thanks also to its twin high-pressure blowers. Its operation can be interlocked with an existing furnace without adding an extra relay. Also, for more convenience, its latches can be relocated on its front (as shown on unit picture). This compact, lightweight, and powerful unit is the ideal choice for small single-family homes, high rise residential building and other limited space applications. What s more, it is the only air exchanger of its size that can be upgraded from an HRV to an ERV, simply by changing its core. *To avoid balancing, the difference between stale air ducts total length and fresh air ducts total length must not exceed 50 ft. Versatile horizontal or vertical port configuration Removable terminal block to ease auxiliary wall control connections Integrated pressure taps, if balancing required by building code ENERGY STAR qualified REPAIRS AND MAINTENANCE All parts of the AVS Constructo 1.0 HRV that could need maintenance can be removed in less than 5 minutes, allowing direct access for easy repairs. The PSC motors are permanently lubricated. Finally, the removable electrical drawer with pull-out PCB assembly allows easy access for maintenance of major sub-components. WARRANTY The AVS Constructo 1.0 HRV is protected by a 2-year warranty on parts only. The heat recovery core is covered by a limited lifetime warranty, with the original proof of purchase. Available at: Controls This unit is very simple to operate. Once it is installed, press on its push button, located on on the bottom of the unit, to activate it. Press once for low speed, once again for high speed, and once more to stop it. The following main controls are available: - Altitude programmable digital control with SMART mode no. 40440 - Deco-Touch digital control no. 40395 - Constructo no. 40350 - Lite-Touch Constructo no. 40370 - Simple-Touch Constructo no. 40390 The following optional auxiliary controls can also be added: - 20-min. lighted push button no. 40440-60-min. mechanical timer no. 00910 For more details about controls, refer to their specification sheet on venmar.ca. Options Complete line of registers and diffusers Electric duct heater Dual exterior hood kit (including the Tandem transition), part no. 14690 Homeshield Defrosting System The AVS Constructo 1.0 HRV uses a unique defrosting method. No negative pressure is created by air exhausted to the outside, as the air is recirculated into the house, helping to prevent any backdraft. STALE AIR FROM FILTERED AIR TO VF0036 Heat Recovery Core Dimensions: 13 x 19 x 6 7/8 (33 cm x 48.3 cm x 17.3 cm) Exchange surface: 55 ft.2 (5.1 m2) Weight: 3.75 lb. (1.7 kg) Material: Polypropylene Type: Cross flow Warranty: Limited lifetime Requirements and standards OUTSIDE TEMPERATURE DEFROST CYCLE (IN MINUTES) Complies with the UL 1812 requirements regulating the installation of Heat Recovery Ventilators Complies with the CSA C22.2 no. 113 Standard applicable to ventilators Complies with CSA C444 requirements regulating the installation of Heat Recovery Ventilators Technical data was obtained from published results of tests relating to CSA C439 Standards HVI certified and ENERGY STAR qualified oc WARMER THAN -5 of WARMER THAN 23 DEFROST/ OPERATION NO DEFROST -5 TO -27 23 TO -17 8/25-27 & LESS -17 & LESS 10/22

DIMENSIONS: AVS CONSTRUCTO 1.0 HRV (PORTS ON SIDES) ALL PORTS FITS 5 DIAMETER DUCTS 1 4 (102 mm) 27 1/16 (688 mm) 22 9/16 (574 mm) 19 13/16 (503 mm) 6 (152 mm) 13¾ (349 mm) 2 3 4 12 3/16 (310 mm) SPECIFICATIONS 1: FRESH AIR TO PORT 2: EXHAUST AIR FROM PORT VENTILATION PERFORMANCE EXTERNAL STATIC PRESSURE NET AIR FLOW GROSS AIR FLOW EXHAUST PA IN. W.G. L/S CFM M 3 /H L/S CFM M 3 /H L/S CFM M 3 /H 25 0.1 53 111 191 53 112 190 57 120 204 50 0.2 51 107 184 51 108 184 54 114 194 75 0.3 48 101 172 48 102 173 52 110 187 100 0.4 46 98 167 47 99 168 49 105 178 125 0.5 43 91 155 43 92 156 47 100 170 150 0.6 41 88 148 42 88 151 45 96 163 175 0.7 39 82 139 39 83 141 43 91 155 200 0.8 37 79 134 38 80 136 40 85 144 225 0.9 34 73 124 35 74 126 37 79 134 250 1.0 34 71 121 34 72 122 36 76 129 ENERGY PERFORMANCE TEMPERATURE NET AIR FLOW C F L/S CFM M 3 /H POWER CONSUMED WATTS SENSIBLE RECOVERY EFFICIENCY APPARENT LATENT RECOVERY/ SENSIBLE MOISTURE EFFECTIVENESS TRANSFER HEATING 0 32 23 50 85 43 65 74 0.01 0 32 30 64 109 58 62 70 0.01 0 32 39 83 141 70 59 66 0.01-25 -13 23 48 82 56 60 78 0.01-25 -13 30 64 109 64 55 72 0 COOLING VK0055A TOTAL RECOVERY EFFICIENCY 35 95 - - - - NOT TESTED 2 (51 mm) 3: FRESH AIR FROM OUTSIDE PORT 4: EXHAUST AIR TO OUTSIDE PORT AVS CONSTRUCTO 1.0 HRV (PORTS ON TOP) 1913 16 (503 mm) 16¼ (413 mm) NOTE: All specifications are subject to change without notice. Model: AVS Constructo 1.0 HRV Core filters: 30 ppi washable foam Speed control on unit: Low & high speeds. Part number top ports: 41502 10.5 x 6.75 x 0.5 (26.7 cm x 17.2 cm x 1.3 cm) Other modes available with main and Part number side ports: 41500 Housing: Pre-painted steel optional wall controls Total assembled weight (including Insulation: Expanded polystyrene Heat recovery core: polypropylene core): 42 lb. (19 kg) Mounting: Suspension by chains - Heat exchange surface area: 55 ft. 2 (5.1 m 2 ) and springs - Type/Material: Crossflow/Polypropylene Oval shaped ports; fit 5 diameter ducts Supply and exhaust blower motor: 2 motors Unit electrical characteristics: Drain: 1/2 (1.2 cm) fittings with - Protection type: Thermally protected Volts Frequency Ampere Watts 10 ft. (3 m) PVC drain hose - Insulation class: B 120 60 Hz 0.85 100 VK0056A ALL PORTS FITS 5 DIAMETER DUCTS 1 2 3 22 9 16 (574 mm) 23¾ (603 mm) 4 1: FRESH AIR TO PORT 2: EXHAUST AIR FROM PORT 3: FRESH AIR FROM OUTSIDE PORT 4: EXHAUST AIR TO OUTSIDE PORT 4 (102 mm) 6 (152 mm) 12 3 16 (310 mm) 2½ (64 mm) Project: Location: Part no.: Qty.: Submitted by: Date: REMARKS Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 www.venmar.ca 13/11 PRODUCT SHEET NO. 91047

HEAT RECOVERY VENTILATOR HRV CONSTRUCTO 1.5ES Part no. 46110 CANADA Part no. 1601702 U.S.A. 66 to 150 CFM (0.4 in. w.g.) VB0166 CONSTRUCTO SERIES: PERFECT FOR NEW RESIDENTIAL CONSTRUCTION Contractors and builders need cost-effective, reliable and code-compliant mechanical ventilation systems for new home construction. The Venmar AVS Constructo Series offers superior value at an entry-level price. The Constructo 1.5ES represents over 15 years of continuous improvement to deliver contractors the durability and reliability they have come to expect from Venmar. Key features: Maintenance free, totally enclosed, sealed bearings motor Pressure taps, balancing dampers and straps for insulated ducts for quick, effective installation Integrated snap-in drain system installs in seconds with no additional parts ENERGY STAR qualified Compatible with the Deco-Touch digital wall control REPAIRS AND MAINTENANCE All parts of the HRV Constructo 1.5ES that could need maintenance can be removed in less than 5 minutes, allowing direct access for easy repairs. The motor is permanently lubricated. WARRANTY The HRV Constructo 1.5ES is protected by a 5-year warranty on parts. The heat recovery core is covered by a limited lifetime warranty, with the original proof of purchase. Available at: Controls This unit is very simple to operate: press on its push button, located on the electrical compartment, to activate it. Press once for low speed, once again for high speed, and once more to stop it. The following main controls are available: - Deco-Touch digital control* no. 40395 - Lite-Touch Constructo no. 40370 - Constructo no. 40350 * Recirculation mode not available. Up to 5 of the following optional auxiliary controls can also be added: - Dehumidistat no. 11297-20-min. lighted push-button no. 12030 For more details about controls, refer to their specification sheet on venmar.ca. Option Complete line of registers and diffusers Defrosting System The HRV Constructo 1.5ES uses an efficient defrosting method. No negative pressure is created by air exhausted to the outside, as the air is recirculated into the house, helping to prevent any backdraft. OUTSIDE TEMPERATURE DEFROST CYCLE ºC ºF DEFROSTING MIN./OPERATING MIN. WARMER THAN -5 WARMER THAN 23 NO DEFROST -5 TO -15 23 TO 5 7/50-15 TO -27 5 TO -17 7/25-27 & LESS -17 & LESS 10/20 VF0053 STALE AIR FROM FILTERED AIR TO Heat Recovery Core Dimensions: 12 x 14 x 15.5 (30.5 cm x 35.5 cm x 39.4 cm) Exchange surface: 102 ft² (9.54 m²) Weight: 6.2 lb (2.8 kg) Material: Polypropylene Type: Crossflow core Warranty: Limited Lifetime Requirements and Standards Complies with the UL 1812 requirements regulating the Complies with the CSA C22.2 no. 113 Standard applicable to ventilators Complies with CSA F326 requirements regulating the Technical data was obtained from published results of tests relating to CSA C439 Standards HVI certified and ENERGY STAR qualified

Dimensions: HRV Constructo 1.5ES Hooks Location for Hanging Chains Motorized Damper 35 (891 mm) 30¼ (768 mm) 17¼ (438 mm) Terminal Block Location Heat Recovery Core 17 (432 mm) Door VK0077A Power Cord 36 (914 mm) Blower Assembly 6 (152 mm) Ventilation Performance EXT. STATIC PRESSURE NET AIR FLOW GROSS AIR FLOW EXHAUST PA IN. W.G. L/S CFM M³/H L/S CFM M³/H L/S CFM M³/H 25 0.1 85 180 306 86 182 309 92 194 330 50 0.2 82 174 296 82 175 297 86 182 309 75 0.3 77 163 277 77 164 279 81 171 291 100 0.4 71 150 255 71 151 257 71 151 257 125 0.5 67 141 240 67 142 241 57 120 204 150 0.6 60 128 217 61 130 221 40 85 144 175 0.7 51 108 183 52 110 187 27 57 97 EXTERNAL STATIC PRESSURE IN. W.G. (PA = N X248.8) 0.8 0.6 0.4 0.2 (L/S) EXHAUST (L/S) 0 VG0089A 0 25 50 75 100 125 150 175 200 CFM (L/S = CFM X 0.4719) (M³/H = L/S X3.6) Energy Performance NET AIR FLOW POWER SENSIBLE APPARENT LATENT RECOVERY TEMPERATURE CONSUMED RECOVERY SENSIBLE MOISTURE ºC ºF L/S CFM M³/H WATTS EFFICIENCY EFFECTIVENESS TRANSFER HEATING 0 32 31 66 112 67 67 79-0.01 0 32 40 86 146 74 65 75-0.01 0 32 54 115 195 90 61 70-0.01-25 -13 38 81 138 87 60 76 0.02 EFFICIENCY VG0090 100 90 80 70 60 50 APPARENT (%) NET (%) 40 0 25 50 75 100 AIR FLOW - L/S (0.47 L/S = 1 CFM) NOTE: All specifications are subject to change without notice. Specifications and Ratings Model: HRV Constructo 1.5ES Part Number Canada: 46110 Part Number U.S.A.: 1601702 Total Assembled Weight (including polypropylene core): 65 lb (29.5 kg) Drains:1/2 (1.2 cm) fittings with 10 ft (3 m) PVC drain Filters: 15 ppi washable reticulated foam 15.375 x 7.125 x 0.75 (39 cm x 18 cm x 1.9 cm) 6 Round Ports Housing: Pre-painted steel Insulation: Expanded polystyrene Mounting: Suspension by chains and springs Supply & Exhaust Blower Motor: 1 PSC motor - Protection type: Thermally protected - Insulation class: B Speed Control on unit: Low & High speed. Other modes available with optional mainl wall controls. Heat Recovery Core: - Heat Exchange Surface Area: 102 ft² (9.54 m²) - Type/Material: Crossflow/Polypropylene Unit Electrical Characteristics: Volts Frequency Amps Watts 120 60 Hz 1.5 160 PROJECT: LOCATION: MODEL NO.: QTY.: SUBMITTED BY: DATE: REMARKS Residential Product Group, 550 Lemire Blvd., Drummondville, QC, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 www.venmar.ca HRVConstructo1.5ESd120518

HEAT RECOVERY VENTILATOR HRV CONSTRUCTO 2.0ES Part no. 47110 82 to 192 CFM (0.4 in. w.g.) VB0167 CONSTRUCTO SERIES: PERFECT FOR NEW RESIDENTIAL CONSTRUCTIONS Contractors and builders need cost-effective, reliable and code-compliant mechanical ventilation systems for new home constructions. The Venmar AVS Constructo Series offers superior value at an entry-level price. The Constructo 2.0ES represents over 15 years of continuous improvement to deliver contractors the durability and reliability they have come to expect from Venmar. Key features: Maintenance free, totally enclosed, sealed bearings motor Pressure taps, balancing dampers and straps for insulated ducts for quick, effective installation Integrated snap-in drain system installs in seconds with no additional parts ENERGY STAR qualified Compatible with the Deco-Touch digital wall control REPAIRS AND MAINTENANCE All parts of the HRV Constructo 2.0ES that could need maintenance can be removed in less than 5 minutes, allowing direct access for easy repairs. The motor is permanently lubricated. WARRANTY The HRV Constructo 2.0ES is protected by a 5-year warranty on parts. The heat recovery core is covered by a limited lifetime warranty, with the original proof of purchase. Available at: Controls This unit is very simple to operate: press on its push button, located on the electrical compartment, to activate it. Press once for low speed, once again for high speed, and once more to stop it. The following main controls are available: - Deco-Touch digital control* no. 40395 - Lite-Touch Constructo no. 40370 - Constructo no. 40350 * Recirculation mode not available. Up to 5 of the following optional auxiliary controls can also be added: - Dehumidistat no. 11297-20-min. lighted push-button no. 12030 For more details about controls, refer to their specification sheet on venmar.ca. Option Complete line of registers and diffusers Defrosting System The HRV Constructo 2.0ES uses an efficient defrosting method. No negative pressure is created by air exhausted to the outside, as the air is recirculated into the house, helping to prevent any backdraft. OUTSIDE TEMPERATURE DEFROST CYCLE ºC ºF DEFROSTING MIN./OPERATING MIN. WARMER THAN -5 WARMER THAN 23 NO DEFROST -5 TO -15 23 TO 5 6/50-15 TO -27 5 TO -17 6/25-27 & LESS -17 & LESS 10/20 VF0053 STALE AIR FROM FILTERED AIR TO Heat Recovery Core Dimensions: 12 x 14 x 15.5 (30.5 cm x 35.5 cm x 39.4 cm) Exchange surface: 102 ft² (9.54 m²) Weight: 6.2 lb (2.8 kg) Material: Polypropylene Type: Crossflow core Warranty: Limited Lifetime Requirements and Standards Complies with the UL 1812 requirements regulating the Complies with the CSA C22.2 no. 113 Standard applicable to ventilators Complies with CSA F326 requirements regulating the Technical data was obtained from published results of tests relating to CSA C439 Standards HVI certified and ENERGY STAR qualified

Dimensions: HRV Constructo 2.0ES Hooks Location for Hanging Chains Motorized Damper 35 (891 mm) 30¼ (768 mm) 17¼ (438 mm) Terminal Block Location Heat Recovery Core 17 (432 mm) Door VK0077A Power Cord 36 (914 mm) Blower Assembly 6 (152 mm) Ventilation Performance EXT. STATIC PRESSURE NET AIR FLOW GROSS AIR FLOW EXHAUST PA IN. W.G. L/S CFM M³/H L/S CFM M³/H L/S CFM M³/H 25 0.1 106 225 382 107 227 386 118 249 423 50 0.2 102 215 365 102 216 367 115 243 413 75 0.3 96 204 347 97 205 348 111 235 399 100 0.4 90 192 326 91 193 328 107 226 384 125 0.5 83 177 301 84 179 304 100 211 358 150 0.6 76 161 274 76 162 275 89 189 321 175 0.7 67 142 241 67 143 243 75 159 270 EXTERNAL STATIC PRESSURE IN. W.G. (PA = N X248.8) 0.8 0.6 0.4 0.2 (L/S) EXHAUST (L/S) 0 0 25 50 75 100 125 150 175 200 225 250 275 VG0091A CFM (L/S = CFM X 0.4719) (M³/H = L/S X3.6) Energy Performance POWER SENSIBLE APPARENT LATENT/RECOVERY NET AIR FLOW TEMPERATURE CONSUMED RECOVERY SENSIBLE MOISTURE ºC ºF L/S CFM M³/H WATTS EFFICIENCY EFFECTIVENESS TRANSFER HEATING 0 32 39 82 139 71 65 75 0.01 0 32 61 130 221 129 60 69 0.01-25 -13 40 84 143 114 60 76 0.03 EFFICIENCY 100 90 80 70 60 50 40 0 25 50 75 100 VG0092 APPARENT (%) NET (%) AIR FLOW - L/S (0.47 L/S = 1 CFM) NOTE: All specifications are subject to change without notice. Specifications and Ratings Model: HRV Constructo 2.0ES Part Number: 47110 Total Assembled Weight (including polypropylene core): 65 lb (29.5 kg) 6 Round Ports Drains:1/2 (1.2 cm) fittings with 10 ft (3 m) PVC drain Filters: 15 ppi washable reticulated foam 15.375 x 7.125 x 0.75 (39 cm x 18 cm x 1.9 cm) Housing: Pre-painted steel Insulation: Expanded polystyrene Mounting: Suspension by chains and springs Supply & Exhaust Blower Motor: 1 PSC motor - Protection type: Thermally protected - Insulation class: B Speed Control on unit: Low & High speed. Other modes available with optional main wall controls. Heat Recovery Core: - Heat Exchange Surface Area: 102 ft² (9.54 m²) - Type/Material: Crossflow/Polypropylene Unit Electrical Characteristics: Volts Frequency Amps Watts 120 60 Hz 2.1 195 PROJECT: LOCATION: MODEL NO.: QTY.: SUBMITTED BY: DATE: REMARKS Residential Product Group, 550 Lemire Blvd., Drummondville, QC, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715 www.venmar.ca HRVConstructo2.0ESd120518