InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Similar documents
Residential Heat & Energy Recovery

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

TECHNICAL SPECIFICATIONS

HEAT RECOVERY VENTILATOR

ENERGY RECOVERY VENTILATOR

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Indoor Air Quality Product Brochure.

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Limited Lifetime core warranty. 5-year warranty on balance of unit.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Indoor Air Quality Product Brochure.

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Ventilation Solutions IAQ Canada

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Product Data HRV A10299

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Product Catalog Commercial Solutions US Edition

Product Catalog Commercial Solutions US Edition

Outside Air Requirements... SOLVED!

Heat Recovery Ventilators (HRVs) Flexibility. in Perfect Form. Improving indoor air quality through better ventilation

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E80 H/E130

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

IAQ VENTILATION SOLUTIONS

Product Data. ERVCCSVB, ERVCCSHB Energy Recovery Ventilators HRVCCSVB, HRVCCSHB Heat Recovery Ventilators

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

Ventilation Solutions IAQ Canada

Product Data A05229 A05330 HRV

IAQ VENTILATION SOLUTIONS

HR150, 200; ER150, 200 Perfect Window Fresh Air Ventilation Systems

READ CAREFULLY AND SAVE R3

COMMERCIAL VENTILATION

OPERATIONS & MAINTENANCE MANUAL RESIDENTIAL HEAT & ENERGY RECOVERY VENTILATORS TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION

BEST PRACTICE RECOMMENDATIONS

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

MiniCore Ventilator (500, 1000) Series Engineering Guide

Heat or Energy Recovery Ventilation System

Energy Recovery Ventilators MCV CORE Series. Customer for Life: Power of Connections Johnson Controls, Inc Page 1

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

10-year industry best core warranty. 5-year warranty on balance of unit.

Overview and Specifications

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Put the V back in HVAC

Healthy, comfortable and energy-efficient ventilation

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Healthy, comfortable and energy-efficient ventilation

SAFETY AND INSTALLATION MANUAL MODEL 8100

Heat Recovery Ventilation

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

The best way to enhance indoor air quality

Tech to Tech May 07 HRV s & ERV s

Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

VERTICAL FAN COIL UNITS

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Heat Recovery Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

Ventilation unit Zehnder ComfoAir 200

62DA,DB,DC,DD,DE,DF07-38

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

Product Data HRVCCLHU HRVCCSVC HRVCCLVU. Heat Recovery Ventilators FEATURES

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

For performance and dimensional data, see back page.

BETTER AIR. BETTER LIFE.

PA 500/1100V Ultra Quiet Ventilation Fan

CATALOGUE Setting a new standard for energy efficient, clean air homes.

Ventilation Unit Zehnder ComfoAir 350

TR Series - The Ultimate ERV

LEED for Homes Points

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

INSTALLATION GUIDE VB0180 VB0148

Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

MODELS VA3B, VB5B VC5B

5 year fan housing and motor warranty

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

Product Data ERVC. Energy Recovery Ventilators. Features

Ventilation Solutions Radon Mitigation

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

State of MN Energy Code Ventilation Review for 2017 Energy Design Conference. By 1. Mike D. Wilson Dakota Supply Group

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

Energy Recovery with Cooling and Heating

ClalrlTech INNOVATIONS. ClairiTech. 120 Hybrid. Installation and Operations Manual Model: H-120 Rev: 1.4

The ultimate fresh air solution.

HRVBBLHU HRVBBSVC HRVBBLVU

HRV Enthalpy. Catalogue

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION, OPERATION & MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR

Transcription:

Inspir Compact Heat and Energy Recovery Multi-Family HRV/ERV

High-Profile Performance & Low-Profile Design Small spaces demand smart technology. Aldes Inspir Compact Heat and Energy Recovery Ventilators (HRV/ERV) fit neatly into condos, apartments, and other multi-family dwellings. These units improve indoor comfort and reduce the building s energy use. Inspir Compact Models NEW! Product Details Rated for 73 CFM (H-HF) and 74 CFM (E-HF and E-HRG) at 0.2 in. w.g. Durable polypropylene core (H-HF) or high-latent-transfer enthalpy core (E-HF and E-HRG) Horizontal configuration for flexible installation Up to 70% sensible recovery efficiency (H-HF) and 73% sensible recovery efficiency (E-HF and E-HRG), a great choice for LEEDcertified buildings Hassle-free balancing using the balancing chart, pressure taps in the door, and the independently adjustable supply and exhaust blowers Pressure-neutral cold climate frost protection using warm recirculated air (E-HRG) Unique compact door allows easy access to the washable MERV 6 filters All models are HVI Certified and ETL Safety Listed E-HRG is ENERGY STAR Qualified (Canada) E-HRG Key Features Exclusive free cooling economizer mode reduces the need for air conditioning in the spring and fall (E-HRG) Compact size (a mere 9 tall) permits installation in tight spaces EvacMAX for on-demand maximum boost ventilation FLEXControl electronically balances airflow circuits for simple, accurate installation No drain required with Aldes high-latent-transfer HLT crossflow ERV technology 2

Dimensions Bottom View Side View (Left) 5" Typ. (127 mm) ACCESS PANEL 9" (229 mm) OUTSIDE 31-1/2" (0 mm) 27" (686 mm) RETURN 22" (559 mm) SUPPLY Side View (Right) 22" (559 mm) Performance 0.8 (200) Ventilation Performance 90 Recovery Performance 0.7 (175) 0.6 (150) External Static Pressure in.w.g. (Pa) 0.5 (125) 0.4 (100) 0.3 (75) 0.2 (50) 0.1 (25) 0 (0) 70 60 50 40 30 20 (35) 30 (50) 40 (70) 60 (28) (38) 100 (47) Efficiency (%) 50 (90) 60 (100) 70 (120) (135) 90 (150) 50 (24) 70 (33) 90 (43) Airflow CFM (L/s) Airflow CFM (L/s) H-HF H-HF E-HF E-HRG E-HF Sensible Effectiveness (Heating) *E-HRG only E-HRG Sensible Efficiency (Heating) Total Efficiency (Cooling) HVI CERTIFIED RECOVERY PERFORMANCE MODEL H-HF E-HF E-HRG FREE COOLING ECONOMIZER MODE SPECIFICATIONS E-HRG Outside Air Temp. CFM (L/s) 56 Heating Heating Cooling Heating Cooling 65 (30) (38) 55 67 (32) (38) 95 F (35 C) 49 (23) 56 65 (30) (38) -13 F 95 F (-25 C) (35 C) 56 50 (24) Bypass Damper Temperature Indoor Temperature Outdoor Net Airflow in Free Cooling Economizer Mode (CFM at 0.4 in. w.g) High Speed Low Speed Sensible Recovery Efficiency Apparent Sensible Effectiveness Latent Recovery/ Moisture Transfer Total Recovery Efficiency 70% 67% 64% 73% 70% 68% -- 73% 70% 68% 62% -- 76% 74% 72% % 78% 76% 74% 81% 79% 77% 78% 74% -- -- -- 61% 59% 55% 66% 63% 60% 56% 64% 66% -- -- -- -- -- -- 64% -- -- -- -- 65% Open - Starts Free Cooling Close - Starts Heat Recovery F C F C CFM L/s CFM L/s > 55 > 13 > 72 > 22 OR OR 74 35 50 24 < 66 < 19 < 55 < 13 < 72 < 22 OR OR -- -- -- -- > 66 > 19 3

Inspir Compact 130 Models Product Details Rated for 120 CFM (H130-HRG) and 133 CFM (E130-HR) at 0.2 in. w.g. Durable polypropylene core (H130-HRG) or high-latent-transfer enthalpy core (E130-HR) 120 VAC electrical requirements Extremely efficient backward-inclined impellers Bottom-hinged access panel Appliance-grade steel cabinet with baked-enamel finish Lightweight construction only 35 lbs (16 kg) Both models are HVI Certified and ETL Safety Listed H130-HRG is ENERGY STAR Qualified (Canada) Key Features Compact size (a mere 9-1/4 tall) permits installation in tight spaces EvacMAX for on-demand maximum boost ventilation FLEXControl electronically balances airflow circuits for simple, accurate installation Automatic timed recirculation defrost for use in extremely cold climates No condensate drain required (E130-HR) E130-HR E130-HR 4

OUTSIDE RETURN Dimensions 5" Typ. (127 mm) Side View (Left) 9-1/4" (235 mm) OUTSIDE OUTSIDE Bottom View 27-11/16" (703 mm) 24-1/8" (613 mm) 24-1/8" (613 mm) (Ø 127 mm) BOTTOM VIEW RETURN RETURN 23-3/4" (578 mm) SUPPLY Side View (Right) Ø 5" Typ. (Ø 127 mm) 9-1/4" (235 mm ACCESS ACCESS PANEL PANEL SIDE VIEW (LEFT) ACCESS PANEL BOTTOM VIEW SUPPLY SUPPLY 22-3/4" (578 mm) SIDE VIEW (RIGHT) Performance Ø 5" Typ. (Ø 127 mm) External Static Pressure in.w.g. (Pa) 1.20 (300) 1.00 (250) 0.8 (200) 0.6 (150) 0.4 (100) 0.2 (50) 0 (0) Ventilation Performance Ventilation Performance SIDE VIEW (LEFT) ACCESS PANEL Efficiency (%) 90 70 60 50 40 30 Recovery Performance 22-3/4" (578 mm) SIDE VIEW (RIGHT) 9-1/4" (235 mm) 40 (19) 60 (28) (38) 100 (47) 120 (57) Airflow CFM (L/s) 140 (66) 160 (76) 40 (19) 60 (28) (38) 100 (47) 120 (57) Airflow CFM (L/s) 140 (66) 160 (76) H130-HRG E130-HR H130-HRG Sensible Effectiveness (Heating) Sensible Efficiency (Heating) E130-HR *H130-HRG only Total Efficiency (Cooling) HVI CERTIFIED RECOVERY PERFORMANCE MODEL H130-HRG E130-HR Outside Air Temp. CFM (L/s) 55 66 (31) Heating Heating Cooling 101 (48) -13 F (-25 C) 68 (32) 50 (24) 76 (36) 102 (48) -13 F (-25 C) 48 (23) 95 F (35 C) 51 (24) Sensible Recovery Efficiency 69% 66% 61% 60% 69% 64% 62% 59% -- Apparent Sensible Effectiveness 78% 75% 69% 76% 85% 77% 73% 79% -- Latent Recovery/ Moisture Transfer Total Recovery Efficiency -- -- -- -- 62% 55% 51% 55% 54% -- -- -- -- -- -- -- -- 49% 5

Application In the diagrams below, the Inspir Compact HRV or ERV is mounted in the ceiling of the master bedroom closet. The blue lines indicate the flow of fresh air for supply and the red lines indicate the flow of stale air for exhaust. Each diagram depicts an acceptable duct configuration. RISER SUPPLY RISER RISER HRV/ ERV HRV/ ERV HRV/ ERV FRESH FRESH Fully Ducted with exhaust air directly ducted to the outside and fresh air supplied by an inlet. Fully Ducted with exhaust air ducted to a central exhaust riser and fresh air supplied by an inlet. Fully Ducted with exhaust air ducted to a central exhaust riser and fresh air supplied by a central riser. Installation Inspir Compact units are slim in height, ideal for horizontal installations above ceilings and in narrow plenum spaces. The model is also narrow enough to easily fit between joists and other structural supports. 6 Mounting hardware is also available to ensure a secure vibration proof installation.

Accessories Description 1 - Humidity Control (P/N 611224) Activates the HRV/ERV to remove excess humidity as desired 2-20/40/60 Timer (P/N 611228) Activates the HRV/ERV to operate on high-speed mode for 20, 40, or 60 minutes 1 - Humidity Control 2-20/40/60 Timer 3 - Speed Control (P/N 611229) Four HRV/ERV speeds: intermittent mode, low and high-speed exterior exchange mode, and unit stop mode 4 - Multifunction Control (P/N ) Gives complete control over the HRV/ERV and supports the free cooling economizer mode 5 - Aluminum Filter (P/N 612404) Traps impurities and grease 6 - Washable Foam Filter (P/N 612405) Traps impurities 3 - Speed Control 4 - Multifunction Control 7 - MERV 6 Filter (P/N 612415) Traps impurities 8 - Carbon Filter (P/N 612406) Traps impurities and eliminates odors 9 - High-Efficiency Filter (P/N 612407) Traps impurities and pollen; use on supply side only 10 - Zone Register Terminal (ZRT ) Regulates ventilation without the need for individual fans 5 - Aluminum Filter 6 - Washable Foam Filter Range ACCESSORY H130-HRG E130-HR H-HF E-HF E-HRG 1 - Humidity Control 611224 611224 611224 611224 611224 2-20/40/60 Timer 611228 611228 611228 611228 611228 3 - Speed Control 611229 611229 611229 611229 611229 7 - MERV 6 Filter 8 - Carbon Filter 4 - Multifunction Control 5 - Aluminum Filter 612404 612404 6 - Washable Foam Filter 612405 612405 7 - MERV 6 Filter 612415 612415 612415 8 - Carbon Filter 612406 612406 9 - High-Efficiency Filter 612407 612407 9 - High-Efficiency Filter 10 - Zone Register Terminal (ZRT ) 10 - Zone Register Terminal (ZRT ) ZRT ZRT 7

www.aldes.us To find out more about Inspir and other related products visit www.aldes.us/ventilatebetter or find us on Distributed By: American ALDES Ventilation Corporation 4521 19th Street Court East, Suite 104 - Bradenton, FL 34203 USA Tel: 941.351.3441 - Fax: 941.351.3442 - Toll-Free: 1.0.255.7749 2016 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice. 8 0816