TEVHR. Heat Recovery Ventilators

Similar documents
TEVHR. Heat Recovery Ventilators

TEVHR. Heat Recovery Ventilator

TEKNOPOOL. Swimming Pool Air Handling Units

AIR HANDLING UNIT TKS MODULAR AIR HANDLING UNIT

Teknogen. Contents. Air Handling Unit Casing of the Unit Fan / Motor Damper Filter Cells Heating / Cooling Coil...

Safety. Connect the product properly to the ground. (Malfunctioning or power leaks can cause electrical shock.)

TEVHR HEAT RECOVERY UNITS

Heat Recovery Units. Heat Recovery Units

TSEK VHR EC HEAT RECOVERY UNITS

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

FOUR-FHR Counter Flow Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

Heat and energy recovery ventilators

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

HEAT RECOVERY DEVICES

Industrial Evaporative Cooling Units

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

AZURE COUNTER FLOW HEAT RECOVERY VENTILATION. aera.com.tr

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Auxiliary Equipment and Accessories

technical data Fan coil unit FWB small duct unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

ERP PRO VESTA HR. Cross Flow Heat Recovery Unit. User s Manual ÇAPRAZ AKIŞLI IGK

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

250mm dia straight pipe length SP4 SP3. Air volume

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Ducted inverter reverse cycle air conditioning

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

Air Handling Unit. Air Handling Unit

CHAPTER 4. HVAC DELIVERY SYSTEMS

CONTACT US. For more information,

EHH SERIES DRAW THROUGH FAN COILS CFM

Package Hygienic Air Handling Units. PHK Series

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

INSTALLATION OPERATION MAINTENANCE INSTRUCTION HEAT PUMP HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION

RoofVent Design Handbook

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Submittal Data Performance Data Electrical Data

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Critical Process Rooftop Series CPRT

SECTION AIR COILS

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

Heat pump and energy recovery systems

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

SIMPLICITY FULL MODULARITY?

Sentinel Demand Energy Recovery Ventilation

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

havanızın konforu için... TÜRKÇE ENGLISH DEUTSCH РУССКИЙ ELEKTROSTATİK FİLTRE ÜRÜN KATALOĞU alperen.com.tr

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

AIR HANDLING UNITS MANDÍK

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

3 rd Generation of VRV. The professional solution for your professional project

VENTILATION & HEATING CATALOGUE.

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Product Brochure Smart Power. Low Profile Ducted

AIR HANDLING UNITS ver B

FAN COIL UNITS. The optimal solution for limited space

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Floor convectors. Technical Catalogue

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

KOMFORT EC DB Suspended heat recovery air handling units

Product Line Introduction. Karl Zhang Technical support engineer

Energy. The Energy ducted units have been designed. Heat Recovery Unit

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

PREEVA air handling unit

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

We simplify construction

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

SILVERTOP RANGE ENERGY RECOVERY

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

LOW STATIC HYDRONIC DUCTED UNIT

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)


Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E.

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

Transcription:

TEVHR Heat Recovery Ventilators

Content Teknogen TEVHR... 3 Unit Specifications... 4 Technical Specifications... 5 Dimensions... 5 Performance Datas... 6 Components... 8 Duck Connection Configurations... 9 Accessories... 10 As one of the leading manufacturers of Heating, Ventilation and Air Conditioning market, TEKNOGEN HVAC stands for innovation, top quality, leading technology and reliable service. That s why our motto is SIMPLY THE BEST SOLUTIONS. One of the core issues for production is quality and high-end components for reaching top quality units. All internal prosesses are being regulated by ISO9001 quality management system. We combine the demands from the market with the new trends for energy savings and environmental needs. This combination leads us to create new designs with innovated ideas. This approach makes us have loyal customers worldwide. TEKNOGEN has a large range for Air handling Units, Fancoils, Heat Recovery Ventilators, Swimming Pool Air Handling Units, Chillers, Rooftop Units, Floor Convectors, Unit Heaters. Our headquarters located in Istanbul and the factory is in Izmir. If you are looking for high quality production and a solution partner, we Teknogen ready.

TEVHR The studies show that people spend most of their lives in indoor conditions in civilised cultures. Because of that,air quality becomes one of the core point for health.on the other hand, increasing demand for energy efficiency and the fact that energy sources are limited, consumption of the energy should be more efficient. TEKNOGEN heat recovery ventilators are designed for longlife usage to supply both energy efficiency and air quality. TEKNOGEN Heat Recovery Ventilator range has 9 models between 800m3/h and 6.000m3/h. The design made for recovering and transferring the thermal load on the exhaust air to fresh air. The state of the art technology components are used in TEKNOGEN Heat Recovery Ventilators to offer electrical and thermal efficiency. Eurovent certified heat exchangers and direct driven plug fans are used in Heat Recovery Ventilators. Fan wings are in aerodynamic design which increases the performance and efficiency. The units come with a digital control panel letting user to adjust air volume and selecting on/off position easily. Functions TEVHR units; Supplying fresh air to indoor Exhausting Filtering of supply air Transfering energy of the exhaust air to fresh air Advantages; Double drain pan Mounting from both sides thanks to functional design Removable plate exchanger Electrical heater or water coil application(optional) Easy replacing of air inlet-outlet connections High efficienct Eurovent certified plate heat exchangers Low noise level and high efficiency by using back curved plug fans Flexible mounting solution with alternative duct connection covers Easy maintenance for all components without demounting of unit Thermal and sound isolation(non flammable) Functional control panel Why To Choose TEKNOGEN Heat Recovery Ventilators Delivery from the stock even for the models with electrical heaters Low Energy Consuption with high efficiency plug fans Eurovent-certified aluminum recuperator of Klingenburg brand for high thermal efficiency Low noise levels G4 class filter Smart automation solutions(optional) Proportional speed control 9 different models between 800m3/h and 6.000m3/h Easy mounting for electrical heaters Water coil (optional) CE and TSEK certified 3

Unit Specifications High efficiency with Eurovent certified heat exchangers The exchangers that are used in TEVHR units are tested in laboratories and their performance are certified. Exchangers supply low pressure drops thanks to state of art technology wing structure which brings energy efficiency as well as lower capacity needs on heating and cooling. Low noise level and high efficiency by using back curved plug fans TEVHR Units use direct driven plug fans with AC motors. Thanks to aerodynamic structure of their wings, they reach high efficiency levels. They can work on high performances with low noise levels. Flexible mounting solution with Alternative duct connection covers TEVHR units offer two alternative duck connections on the unit. One or both of them could be used in case of necessity. Easy maintenance for all components without demounting of unit All the components are detachable in case of maintenance needs without demounting of the unit. Thermal and sound isolation (Flame retardant) Flame retardant, polyurethane foams are used in TEVHR units to assure thermal and sound isolation. The flame retardant feature of isolation prevents thermal transfer. Fans,filters and heat recovery exchangers of the TEVHR are reachable in false ceiling through service doors. 4

Technical Specifications TEVHR Birim 800 1000 1500 2000 2500 3000 4000 5000 6000 Electrical Connections 1~230 V 50 Hz 3~380 V 50 Hz Performance Datas Air Flow ( 1 ) m 3 /h 800 1000 1450 1900 2400 2970 3830 4700 5700 Sound Level ( 2 ) db (A) 44 45 46 48 49 50 52 53 59 Electrical Requirements Fan/motor Power ( 3 ) W 270 420 570 650 1050 1080 1300 1430 1900 Maximum Current (A) 1,2 1,9 2,5 3,0 4,8 4,8 4,8 6 6 1 Airflow data when the ESP is 0 Pa. 2 Sound levels are measured at 250Hz and at 1,5m distance. 3 Power consumption Dimensions D C G E F A B TEVHR Model Dimesions A B C D E F G Weight (kg) 800 660 1230 355 795 1312 200 200 51 1000 660 1230 355 795 1312 200 200 52 1500 910 1430 360 1045 1510 170 270 72 2000 910 1430 430 1045 1510 250 300 84 2500 1170 1790 425 1300 1870 300 300 103 3000 1170 1790 515 1300 1870 370 370 116 4000 1170 1890 515 1300 1970 370 370 125 5000 1380 1990 645 1455 2070 432 432 186 6000 1380 1990 645 1455 2070 432 432 199 5

Performance Datas TEVHR 800 / Air Flow Performance TEVHR 1000 / Air Flow Performance External Pressure Drop (Pa) External Pressure Drop (Pa) External Pressure Drop (Pa) TEVHR 1500 / Air Flow Performance TEVHR 2000 / Air Flow Performance TEVHR 2500 / Air Flow Performance TEVHR 3000 / Air Flow Performance External Pressure Drop (Pa) External Pressure Drop (Pa) External Pressure Drop (Pa) 6

Performance Datas TEVHR 4000 / Air Flow Performance TEVHR 5000 / HAVA PERFORMANSI External Pressure Drop (Pa) External Pressure Drop (Pa) TEVHR 6000 / Air Flow Performance External Pressure Drop (Pa) 7

Components Heat Recovery Exchanger Longlife,plate type heat recovery exchanger High thermal efficiency Low pressure drop Eurovent certified Detachable, easy maintenance Washable EA Exhaust Air OA Outside Air SA Supply Air RA Return Air Plug Fan Direct driven Plug fans with, AC motor Mono-phase connection (TEVHR800-TEVHR5000) Three-phase connection (TEVHR6000) Low electrical consumption Low noise level Protection against overheating Easy maintenance with service cover and easy detachment with smart connection socket Filters G4 class according to EN 779 Cleanable Leakproof sledge design Easy service with side and down service covers Body of the Unit High Corrosion resistant sheet metal painted in RAL 9002 Easy maintenance with service doors Easy service Flame retardant thermal and sound isolation Easy mounting with hangers Tests TEVHR units are tested according to with EN-60204-1 standards at factory test laboratories. Grounding Continuity Test Isolation Resistance Test Puncture Voltage Tests are applied at the factory According to EN-779 below tests are applied; Internal leakage External leakage Pressure drop Heat and Humidity 8

Duct Connection Configuration RIGHT HAND SIDE INSTALLATION Alternative Alternative (Exhaust Air or Fresh Air) (Exhaust Air or Fresh Air) Air Inlet (Return Air or Outside Air) Air Inlet (Return Air or Outside Air) LEFT HAND SIDE INSTALLATION (Exhaust Air or Fresh Air) Air Inlet (Return Air or Outside Air) Air Inlet (Return Air or Outside Air) (Exhaust Air or Fresh Air) Alternate Alternate 9

Accessories Digital Room Controller TEVHR units are supplied with a digital room control panel. It can control air flow while changing the exhaust and fresh air flows individually(l/m/h).all the changes could be followed on LCD screen. The mode of the unit can be adjusted to winter or summer.in summer mode only the unit works. In winter mode, Unit and electrical heater works. According to the temperature adjusted on the control panel, electrical heater start up automatically. The off button on the control panel stops both electrical heater and unit. Electrical board comes with the unit, it adopts unit orders coming from room controller.components like relay,contactor,capacitor and connector are located in electrical board. Required electrical power should be supplied to heater and also to unit Tevhr Units can connect to Building Automation System via contactor or MODBUS(RS485).Thereby all the features of the unit can be controlled through a centralized system. Fresh air and return air flows can be adjusted with automation panel.thus,negative or positive pressure could be obtained. By using Air Quality or CO2 sensors (optional) Ventilation on demand feature could be started. To use it, either room control panel or building automation panel should be taken to VOD mode. Digital Controller Advanced Panel Specifications 1 Manages exhaust and fresh air fan volumes individually in 5 steps 2 Filter service alarm after 1200 hours of performance 3 Thermal protection for motors 4 Electrical heater connection 5 Water Coil connection 6 Protection of heaters for over-heating 7 Boost Function Standard Panel Specifications 1 Manages exhaust and fresh air fan volumes individually in 5 steps. 2 Filter service alarm after 1200 hours of performance. 3 Thermal protection for motors. Pro Panel Specifications 1 Manages exhaust and fresh air fan volumes individually in 5 steps 2 Filter service alarm after 1200 hours of performance 3 Thermal protection for motors 4 Electrical heater connection 5 Water Coil connection 6 Protection of heaters for over-heating 7 Boost Function 8 Carbondioxide sensor connection 9 Control of damper motor 10 BMS control 11 Control of heating and cooling coil valves 12 Fire alarm 13 Weekly programming 14 Thermal check with a sensor located on duck 10

Accessories Electrical Heater A C Control board Overheat sensor, thermistor non-flammable macaron for electrical cables Low energy consumption with step control Rectangular shape Galvanised steel body H G E F B D Resistor Model Electrical Power Step A B C D E F G x H Electrical Power Quantity TEVHR kw mm W 800 2 1 176 178 282 248 247 357 200 x 200 667 3 1000 3 1 176 178 282 248 247 357 200 x 200 1000 3 1500 3 1 326 328 252 218 317 427 170 x 270 500 6 2000 5 2 326 328 332 298 347 457 250 x 300 834 6 2500 7 2 326 328 382 348 347 457 300 x 300 1167 6 3000 8 3 476 478 452 418 417 527 370 x 370 889 9 4000 10 3 476 478 452 418 417 527 370 x 370 1112 9 5000 13 3 476 478 512 478 477 587 430 x 430 1444 9 6000 13 3 476 478 512 478 477 587 430 x 430 1444 9 Hot Water Coil TEKNOGEN hot water coils are used at the exit of fresh air duct or inside the duct. They are made up of copper pipe,aluminium wings and brass collectors. The electrical board starts up the coil on/off according to set temperature with room controller. They have low pressure drops and can connect to duck system without using additional connection systems. H W L Air flow Heating Performance (90/70 C) Capacity Blowing Temperature Waterside pressure drop Connection Diameter Airside pressure drop Consumed Power Dimensions Duct Connection W L H A B m 3 /h kcal/h C kpa inch mm kpa W mm mm 900 4190 34 3 1/2 21,3 12 100 240 440 500 396 411 1060 5784 36.5 5.34 1/2 21,3 19 100 240 440 500 396 411 1400 9129 40.5 21.5 1/2 21,3 46 100 240 440 500 396 411 1600 11070 41.5 31.8 1/2 21,3 63 130 240 440 500 376 376 1725 12760 45.5 37 1/2 21,3 78 130 240 440 500 376 376 1800 17620 49.5 32.4 1/2 21,3 51 130 350 550 635 481 513 1900 20551 55 66.8 1/2 21,3 61 130 350 550 635 481 513 2450 25778 54 30.6 1/2 21,3 84 170 350 550 635 481 564 11

APRIL 2016 BY HVAC SYSTEMS INC. RESERVES THE RIGHT TO MAKE ALTERATIONS DUE TO TECHNICAL DEVELOPMENTS WITHOUT PRIOR NOTICE. HEADQUARTERS BY ISITMA SOGUTMA KLIMA HAVALANDIRMA SAN TIC. A.S. ATATURK MAH. DUDULLU CAD. SEREF SOKAK. NO 46 34758 ATASEHIR - ISTANBUL / TURKEY TEL + 90 216 324 51 59 FAX + 90 216 324 99 32 info@teknogenhvac.com WWW.TEKNOGENHVAC.COM FACTORY KAZIM KARABEKIR MAHALLESI BEKIR SAYDAM CAD. NO:104 IS KAPI NO: 25 PANCAR, AYRANCILAR, TORBALI - IZMIR / TURKEY TEL + 90 232 864 11 11 FAX + 90 232 864 10 11