Light Commercial Heat/Energy Recovery Ventilator

Similar documents
Light commercial models

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

SHR & VHR Models. SHR & VHR Series. Installation Manual. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

KHP Models. KHP Series. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

KHP 6000 KHP MODEL FOR LIGHT COMMERCIAL

HEPA Filtration. HEPA Series. Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

SER150. Installation Manual. Energy Recovery Ventilators

PW 150 / PW 100. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1

VHR SERIES VHR 704. Installation Manual. Heat Recovery Ventilator INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION AND OPERATION INSTRUCTIONS

Energy Recovery Ventilators

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

NU800, NU1200 & NU1600

SAFETY AND INSTALLATION MANUAL MODEL 8100

IAQ VENTILATION SOLUTIONS

Product Catalog Commercial Solutions US Edition

Heat or Energy Recovery Ventilation System

IAQ VENTILATION SOLUTIONS

COMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD

Product Catalog Commercial Solutions US Edition

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

HEAT RECOVERY VENTILATORS INSTALLATION AND OWNERS OPERATING MANUAL MODEL SHRV2500DD

MODELS LT15 & LT20 INSTALLATION INSTRUCTION FOR HEAT RECOVERY VENTILATOR (HRV)

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

TR Series - The Ultimate ERV

Ventilation Solutions IAQ Canada

Limited Lifetime core warranty. 5-year warranty on balance of unit.

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

INSTALLATION INSTRUCTION & OWNER S GUIDE

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Operation and Installation Manual. Models 330ERV 530ERV 730ERV 1230ERV. Commercial Energy Recovery Ventilators (ERV) 69-ComERV

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

DBF 4XL Dryer Booster Fans

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Summeraire Manufacturing Peterborough, Ontario, Canada, K9J 6X6

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

OPERATIONS & MAINTENANCE MANUAL RESIDENTIAL HEAT & ENERGY RECOVERY VENTILATORS TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION

Installation Instructions

HR150, 200; ER150, 200 Perfect Window Fresh Air Ventilation Systems

Put the V back in HVAC

Summeraire Mfg. Peterborough, Ontario, Canada, K9J 6X6

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

Ventilation Solutions IAQ Canada

Installation Guide. MAX Series. 69-MAX-Install Setting a new standard for energy efficient, clean air homes

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

NUWAVE SERIES. Residential Central Heat Recovery Ventilator Product Specifications and Installation and User Manual NuWave Series Models

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E80 H/E130

Heat Recovery Ventilation Systems OWNER S GUIDE

Modular Supply Make-Up Air Unit

Indirect Gas-Fired Make-Up Air

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Desiccant Dehumidifier

LEAVE FOR HOMEOWNER: Installation Instruction of Heat Recovery Ventilator (HRV) PDF 文件使用 "pdffactory Pro" 试用版本创建 General.

Residential Heat & Energy Recovery

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions

10-year industry best core warranty. 5-year warranty on balance of unit.

Model 1750A/ 1770A Dehumidifier Installation Instructions

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Model 8120 and 8126 Safety & Installation Instructions

INSTALLATION AND OPERATION MANUAL MODEL TR70\TR130\TR200\TR300 TOTAL RECOVERY FOR ALL CLIMATES (TR)

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

NW85T - NW125T APPLICATION WARNING

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

VERTICAL FAN COIL UNITS

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Phone: Fax:

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

SECTION AIR HANDLING UNIT

CVS Model Inline Multi-Port Ventilators

INSTALLATION GUIDE VB0180 VB0148

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS

Energy Recovery with Cooling and Heating Model ERCH

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Max Series 5 Speed Electronics Lifestyle MAX Digital Control included

TECHNICAL SPECIFICATIONS

HRV / ERV INSTALLATION AND OPERATING INSTRUCTIONS

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Transcription:

Light Commercial Heat/Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT R CC R US CAUTION - Before installation, careful consideration must be given to how this system will operate if connected to any other piece of mechanical equipment, i.e. a forced air furnace or air handler, operating at a higher static. After installation, the compatibility of the two pieces of equipment must be confirmed by measuring the airflow s of the Heat / Energy Recovery Ventilators. It is always important to assess how the operation of any HRV/ERV may interact with vented combustion equipment (i.e. Gas Furnaces, Oil Furnaces, Wood Stoves, etc.). NEVER - install a ventilator in a situation where its normal operation, lack of operation or partial failure may result in the backdrafting or improper functioning of vented combustion equipment!!! ERV-WI 500 HRV-XI 450 or ERV-XI 450 Your ventilation system should be installed in conformance with the appropriate provincial or state requirements or in the absence of such requirements with the current edition of the National Building Code, and / or ASHRAE s good Engineering Practice. INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Limited Warranty The HRV-XI 450 heat recovery polypropylene core has a limited lifetime warranty. The ERV-XI 450 energy recovery enthalpy core has a limited 5 year warranty. The ERV-WI 500 energy recovery enthalpy wheel has a limited year warranty. The HRV-XI 450 & ERV-XI 450 has a warranty that is limited to 5 years on parts and 7 years on the motor & the ERV-WI 500 has a warranty that is limited to year on parts and 7 years on the motors each from the date of purchase, including parts replaced during this time period. If there is no proof of purchase available, the date associated with the serial number will be used for the beginning of the warranty period. The motors found in all Fantech HRV/ERV s require no lubrication, and are factory balanced to prevent vibration and promote silent operation. The limited warranty covers normal use. It does not apply to any defects, malfunctions or failures as a result of improper installation, abuse, mishandling, misapplication, fortuitous occurrence or any other circumstances outside Fantech s control. Inappropriate installation or maintenance may result in the cancellation of the warranty. Any unauthorized work will result in the cancellation of the warranty. Fantech is not responsible for any incidental or consequential damages incurred in the use of the ventilation system. Fantech is not responsible for providing an authorized service centre near the purchaser or in the general area. Fantech reserves the right to supply refurbished parts as replacements. Transportation, removal and installation fees are the responsibility of the purchaser. The purchaser is responsible to adhering to all codes in effect in his area. * This warranty is the exclusive and only warranty in effect relative to the ventilation system and all other warranties either expressed or implied are invalid. TABLE OF CONTENTS TECHNICAL DATA HRV-XI 450... 3 ERV-XI 450... 5 ERV-WI 500... 7 OPERATION Modes Of Operation...9 Optional Remote Controls... 9 INSTALLATION... 0 Mounting the Unit... 0 Location & Ducting... Examples... 4 Air Flow Balancing... 6 MAINTENANCE...7 ELECTRICAL CONNECTIONS... 8 ASHRAE Standard 62-200 defines acceptable ventilation rates for various applications. Outdoor Air Requirements Examples Application CFM per Person L/s per Person Coin-operated laundry 5 8 Cafeteria, Fast Food 20 0 Bars 30 5 Conference Room 20 0 Reception Area 5 8 Beauty Shop 25 3 Classroom 5 8 Libraries 5 8 Medical 5 8 Photo Studios 5 8 Living Areas (residential).35 air changes per hour but not less than 5 cfm (7.5 L/s) per person Autopsy Rooms (0.5 cfm/ft 2 or 2.5 L/s m 2 ) Locker Rooms (0.5 cfm/ft 2 or 2.5 L/s m 2 ) * Swimming Pools (0.5 cfm/ft 2 or 2.5 L/s m 2 ) Public Restrooms (cfm/wc or cfm/urimac) 50 25 * Call factory for details.800.565.548 2

Heat Recovery Ventilator HRV-XI 450 Light Commercial HRV SPECIFICATIONS CASE 20 gauge galvanized steel. Baked powder coated paint, grey. Insulated with " (25 mm) foil-face fiberglass insulation to prevent condensation. Two (2) drain connections /2" NPT. BLOWERS Two ebm direct drive external rotor blowers with forward curved blades. Blowers come with permanently lubricated sleeves for smooth and quiet operation. Blowers come pre-wired with 4 speeds, three of which are available to the installer as standard. Blowers are electrically connected with a quick connect for quick and easy inspection of blowers. The HRV-XI 450 Heat Recovery Ventilation system (HRV) complements the energy efficiency of the modern building by filtering incoming fresh outdoor air before it enters the heatrecovery core where it is preheated by the outgoing, stale contaminated air. The HRV then distributes the preheated fresh filtered air throughout the building by direct ductwork installed specifically for the HRV or through the ductwork of a forced-air system. APPLICATIONS INCLUDE: Class Rooms Retail Shops Hair Salons Bars & Restaurants POWER & WEIGHT Volts Amperage Weight Shipping Weight Blowers Phase Offices Clinics Animal Shelters Large Homes OPTIONAL CONTROLS (WHITE ONLY) 5V Total 7.7 Amps Total 40 Lbs R 80 Lbs CC US 5V, 60 Hz, 3.85 Amps Single Phase MDEH Mechanical Low Voltage Dehumidistat FD 5M 5 Minutes Crank Timer AQS Air Quality Sensor * External dry contacts (provided) CORES Two (2) modular polyproplene heat recovery cores configured for an efficient cross-flow ventilation. Each core is 2" x 2" (305 x 305 mm) with a 5" (380 mm) depth. Cores are manufactured using silicone to withstand extreme temperature variations. (Aluminum cores are optional.) FILTERS Four (4) Washable Electrostatic Panel Type Air Filters,.75" (298mm) x 5" (380mm) x 0.25" (6mm) MOUNTING Unit can be installed using the four (4) mounting brackets included. Brackets fasten to HRV (bolts provided) and to floor joists using wood screws, not provided. Unit may also be suspended by using the supplied brackets and threaded rod, not supplied, or placed on a platform. CONTROLS Low voltage (24VAC) external dry contacts to activate high speed. External three (3) position switch for LOW/STAND BY/ MED continuous ventilation speeds. DEFROST A preset 5 minute defrost sequence is activated at an outdoor air temperature of 23 F (-5 C) and lower. During the defrost sequence, the supply blower shuts down & the exhaust blower switches into high speed to maximize the effectiveness of the defrost strategy. The unit then returns to normal operation for 25 minutes, and continues cycle. SERVICEABILITY Cores, filters and drain pans can be accessed easily from both sides of the HRV from hinged access panels. Cores conveniently slide out with only 5" (380mm) clearance. Blowers can be accessed from both sides of the HRV from fastened access panels. Blowers are easily removed by removing the access panel and sliding the motor plates out of the HRV. A quick connect allows for fast inspection of blowers. FOR MORE INFORMATION CONTACT: 3

HRV-XI 450 Light Commercial HRV Dimensions MOUNTING HOLES(/4-20UNC BOLT) ELECTRICAL BOX (can be relocated in the field to either the front or the back of the cabinet depending on port direction installer chooses) 2.3" (58mm) 8.0" (202mm) 22.0" (556mm) 8.0" (202mm) 4.0" (355mm) 32.0" (86mm).9" (47mm) DRAIN CONNECTION /2 NPT 32.4" (822mm) Airflow (L/s) 0 35 7 06 42 77 22 248 283 2 497.6 0.75 Static Pressure (in WC).8.6.4.2 0.8 0.6 0.4 Low High * Med-High Med 447.8 398. 348.3 298.6 248.8 99.0 49.3 99.5 Static Pressure (Pa) Efficiency (%) 0.7 0.65 0.6 0.55 0.5 0.2 49.8 0 0.0 0 50 00 50 200 250 300 350 400 450 500 Airflow (cfm) * Med-High - Contact Factory for wiring info 0.45 50 200 250 300 350 400 450 500 Airflow (cfm) Airflow Unit: Date: Contractor: 4 Project:

Energy Recovery Ventilator ERV-XI 450 Light Commercial ERV SPECIFICATIONS CASE 20 gauge galvanized steel. Baked powder coated paint, grey. Insulated with " (25 mm) foil-face fiberglass insulation to prevent condensation. BLOWERS Two ebm direct drive external rotor blowers with forward curved blades. Blowers come with permanently lubricated sleeves for smooth, quiet operation. Blowers come pre-wired with 4 speeds, three of which are available to the installer as standard. Blowers are electrically connected with a quick connect for fast and easy inspection of blowers. The ERV-XI 450 lowers demand on air conditioning systems. Air supplied from outdoors enters through the Energy Recovery Core where it transfers the heat and humidity to the exhaust air. The air supplied by the ERV-XI 450 is now cooler, dryer and more comfortable. The ERV-XI 450 distributes the pre-conditioned fresh filtered air throughout the building by direct ductwork installed specifically for the ERV or through the ductwork of a forced-air system. APPLICATIONS INCLUDE: Class Rooms Retail Shops Hair Salons Bars & Restaurants POWER & WEIGHT Volts Amperage Weight Shipping Weight Blowers Phase Offices Clinics Animal Shelters Larger Homes 5V Total 7.7 Amps Total 40 Lbs R 80 Lbs CC US 5V, 60 Hz, 3.85 Amps Single Phase CORES Two (2) modular enthalpic energy recovery cores configured for an efficient cross-flow ventilation. Each core is 2" x 2" (305 x 305 mm) with a 5" (380 mm) depth. FILTERS Four (4) Washable Electrostatic Panel Type Air Filters,.75" (298mm) x 5" (380mm) x 0.25" (6mm) MOUNTING Unit can be installed using the four (4) mounting brackets included. Brackets fasten to ERV (bolts provided) and to floor joists using wood screws, not provided. Unit may also be suspended by using the supplied brackets and threaded rod, not supplied, or placed on a platform. CONTROLS Low voltage (24VAC) external dry contacts to activate high speed. External three (3) position switch for LOW/STAND BY/ MED continuous ventilation speeds. SERVICEABILITY Cores and filters can be accessed easily from both sides of the ERV from hinged access panels. Cores conveniently slide out with only 5" (380mm) clearance. Blowers can be accessed from both sides of the ERV from fastened access panels. Blowers are easily removed by removing the access panel and sliding the motor plates out of the ERV. A quick connect allows for fast inspection of blowers. OPTIONAL CONTROLS (WHITE ONLY) FD 5M 5 Minute Crank Timer AQS Air Quality Sensor MDEH Dehumidistat (read full description of control found under "optional remote control" in this manual) FOR MORE INFORMATION CONTACT: 5

ERV-XI 450 Light Commercial ERV Dimensions Airflow (L/s) 24 59 94 30 65 20 236 27.6 398. 0.85 Static Pressure (in W.C.).4.2 0.8 0.6 0.4 0.2 Low Med High * Med-High 348.3 298.6 248.8 99.0 49.3 99.5 49.8 Static Pressure (Pa) Efficiency (%) 0.83 0.8 0.79 0.77 0.75 0.73 0.7 0.69 0 0.0 50 00 50 200 250 300 350 400 450 500 Airflow (cfm) * Med-High - Contact Factory for wiring info 0.67 50 200 250 300 350 400 450 Airflow (cfm) Airflow Unit: Date: Contractor: 6 Project:

Energy Recovery Ventilator ERV-WI 500 Light Commercial ERV SPECIFICATIONS CASE 20 gauge galvanized steel. Baked powder coated paint, grey. Insulated with " (25 mm) foil-face fiberglass insulation to prevent condensation. The ERV-WI 500 is an energy recovery ventilator (ERV) that transfers both latent and heat energy. Designed for most cliamates and especially for hot humid regions, the ERV -WI 500 is an effective balanced ventilator that reduces energy costs. Air drawn in from outside enters through the ERV wheel where it is conditioned by the seperated exhause air stream. APPLICATIONS INCLUDE: Class Rooms Retail Shops Hair Salons Bars & Restaurants POWER & WEIGHT Volts Amperage Weight Shipping Weight Blowers Phase OPTIONAL CONTROLS Offices Clinics Larger Homes 5V Total 8.2 Amps Total 300 Lbs 340 Lbs R 5V, 60 Hz, 3.85 Amps Single Phase FD 5M 5 Minute Crank Timer High-voltage 20 V Speed Controller for blowers Can be hard wired to remote location * ERV unit is shipped from factory set on high speed MDEH Dehumidistat (read full description of control found under "optional remote control" in this manual.) Other controls not available through Fantech may be used if compatible with this unit, see controls. BLOWERS Two ebm direct drive external rotor blowers with backward curved blades. Blowers come with permanently lubricated bearings for smooth, quiet operation. Blowers come pre-wired with speed, but can be individually slowed down with optional speed control. Blowers are electrically connected with a quick connect for quick and easy inspection of blowers. FILTERS Two (2) 2" medium efficiency pleated filters, one () per air stream. MOUNTING Unit may be suspended by using the supplied brackets and threaded rod, not supplied, or placed on a platform. CONTROLS Low voltage (24VAC) internal dry contacts to activate unit from off position to high speed, see wiring diagram. DEFROST A preset 5 minute defrost sequence is activated at an outdoor air temperature of 23 F (-5 C) and lower. During the defrost sequence, the supply blower shuts down. The unit then returns to normal operation for 25 minutes, and continues cycle, until temperature rises above set point. SERVICEABILITY Wheel and filters slide out without tools. Access door is secured with safety screw. ENTHALPY WHEEL Homogenous media; Not coated or bonded; Will not delaminate Synthetic wheel is completely corrosion resistant Unitary wheel media construction maximizes face flatness and fluted geometry to minimize cross-contamination 4-Å molecular sieve desiccant allows only water molecules to be transferred; Minimal cross-contamination Wheel is completely water washable Maintenance-free bearings Full contact brush seals Certified to 060 Rating Air to Air Energy Recovery Equipment FOR MORE INFORMATION CONTACT: 7

ERV-WI 500 Light Commercial ERV Dimensions (25.70") 654mm (8") 203mm (50.23") 276mm (3.24") 82mm (8.32") 465.4mm (30.40") 772mm (32.6") 87mm (4") 355mm (7.67") 449mm (5.90") 49mm (54.30") 379mm (56.30") 429mm Airflow (L/s) Static Pressure (in W.C.) Low Speed High Speed Static Pressure (Pa) Airflow (cfm) Airflow Unit: Date: Contractor: 8 Project:

OPERATION MODES OF OPERATION. Continuous / Ventilation Mode In this mode of operation both fans are operating and exchanging air with the outside. The heat/energy recovery ventilator (HRV/ERV) constantly exchanges the air at the rate you select, either at low or medium speed, and switches to high speed when activated by an optional remote control. The "Low" and "Med" fan speed selection will cause the unit to operate in continuous exchange mode at a reduce exchange rate. Continuous mode is recommended, since pollutants are slowly but constantly being generated in a building. NOTE: Model ERV-WI 500 is a single speed unit only. Optional speed control is available. 2. Intermittent / Standby Mode The system is always on standby and operates at high speed when activated by an optional remote control (required): "Standby" should be selected if the user wishes to stop the unit from continuous exchange. 3. Defrost (Fan shutdown HRV-XI 450 & ERV-WI 500 only) The automatic defrost cycle of HRV s consists of a fan shutdown. When the supply air stream temperature goes below 23 F (-5 C), the supply motor shuts down and the exhaust motor goes in to high speed. Ambient air is passed through the unit for a period of 5 minutes. The supply motor will then re-start and run at the preset speed. The exhaust motor will also slow down to the preset speed, and the unit will operate in the run cycle for 25 minutes. This fan shutdown defrost cycle continues until the supply air stream rises above 23 F (-5 C). SETTING SPEED The HRV/ERV is shipped from the factory on low speed, intermittent operation can be obtain by toggle switch located on outside of cabinet (HRV-XI 450 & ERV-XI 450) or by manipulating jumpers in the electrical box. See wiring diagram. The ERV-WI 500 is factory set to high speed. Internal low voltage contacts allow interuption of power to unit when optional remote control is used. See spec sheet for control options. OPTIONAL REMOTE CONTROLS HRV-XI 450 ERV-XI 450 Example Dry Contacts * * HRV-XI 450 Shown Dehumidistat MDEH The wall mount dehumidistat monitors the humidity level in the area it is installed. When the humidity level rises above the desired set-point, the HRV will activate to high speed/override mode. Once the humidity level returns to desired condition, the unit will return to the normal mode. Two (2) low voltage wires required for operation. Note the dehumidistat helps dehumidify by increasing the speed of the HRV/ERV. Dehumidification will only take place when the air outside is dryer than the air inside. Air Quality Sensor AQS (Not compatible with ERV-WI 500) The wall mount Air Quality Sensor (AQS) monitors indoor air quality and activates the override mode when cigarette smoke, formaldehyde, benzene, volatile organic compounds and other pollutants are detected. The unit will then return to normal mode once the air pollutants are reduced to a pre-determined lower level. Three low voltage wires are required for operation * This control is not a warning device. 9

INSTALLATION PRACTICAL TIPS Install the unit close to the outside wall on which the supply and exhaust hoods will be mounted. Have a nearby power supply 20 Volts, 60 Hz. Have the possibility of mounting the unit to supporting beams. Mount the unit as level as possible in order to allow proper condensate drainage. Failure to do so may void warranty. (HRV-XI 450 only) Have access to a water drain for the condensate of the unit during defrost. (HRV-XI 450) LOCATION The HRV/ERV must be located in a heated space where it will be possible to conveniently service the unit. Typically the HRV/ERV would be located in the mechanical room, above a drop ceiling or an area close to the outside wall where the weatherhoods will be mounted. Attic installations are not normally recommended due to extreme temperatures, and difficulty in performing, required service & maintenance. If an attic is slected, special care should be taken in ensuring the unit will perform as intended. Unit may need to be protected with insulated shelter, built on site. Connecting appliances to the HRV/ERV It is not recommended, including: - clothes dryer - kitchen exhaust hoods - combustion venting - central vacuum system These appliance may cause lint, dust or grease to collect in the HRV, damaging the unit. NOTE: Connecting any of these type of appliances to the HRV will invalidate your warranty MOUNTING The HRV-XI or ERV-XI can be accessed for regular maintenance by both sides using one of the two latched doors. Leave appropriate clearance. Installing Drain Line (HRV-XI 450 only) Through normal operation and including defrost mode, the HRV-XI 450 may produce some condensation. This water should flow into a nearby drain, or be taken away by a condensate pump. The HRV and all condensate lines must be installed in a space where the temperature is maintained above the freezing point. A P trap should be made in the drain line. This will prevent odors from being drawn back up into the unit. The drain connection is a /2" NPT nipple. Install the drain hose, making a P trap 0

INSTALLING DUCTS GOING TO / FROM OUTSIDE INSTALLING THE DUCTING TO THE WEATHERHOODS OUTSIDE WEATHERHOODS The weatherhoods must have built-in "bird" screens with /4 inch (6.35 mm) minimum mesh to prevent birds and rodents from entering into the ductwork. Do not use smaller mesh as it will be very susceptible to pluging up. The preferred location of the weatherhoods is: no less than 0 ft. (3 m) apart from each other. at least 8 inches (457.2 mm) snow line or ground level. supply hood must be kept away from source of cantaminants, such as automobile exhaust fumes, gas meters, garbage cans, containers, cooling towers, tar roofs, etc. avoid prevailing winds, whenever reasonably possible. The outside perimeter of the weatherhood must be sealed to prevent leakage into the building. The design and size of the weatherhoods or louvers chosen by the installer must allow for adequate free area. Water and snow penetration of the system is minimized when the airflow does not exceed 000 FPM (5.08 m/s) free area velocity. DUCTING FROM THE WEATHERHOODS TO AND FROM THE HRV/ERV Insulated galvanized sheet metal ducting with sufficient cross section with an integral single piece vapor barier should be used to connect the HRV/ERV to the weatherhoods. Insulated flex duct may be used in moderation, if sized and installed properly. (Consult local codes) A minimum R value of insulation should be equal to 4 (RSI 0.75),consult local codes. All ducts should be sealed using a good bead of high quality caulking (preferably acoustical sealant) and a high quality aluminum foil tape, or other approved duct sealant.

INSTALLING DUCTS TO / FROM INSIDE To maximize airflow in the ductwork system, all ducts should be kept short and have as few bends or elbows as possible. Forty-five degree are preferred to 90 elbows. Use Y tees instead of 90 elbows whenever possible. All duct joints must be fastened with screws or duct sealant and wrapped with a quality duct tape to prevent leakage. Aluminum foil duct tape is recommended. SUPPLY AIR DUCTING In buildings without a forced air HVAC systems, fresh air should be supplied to all habitable areas. It should be supplied from high wall or ceiling locations. Grilles that diffuse the air comfortably such as Fantech grille {MGE (metal) or PGE (plastic)}s are recommended.to avoid possible noise transfer through the ductwork system, a piece of flexible ducting should be connected between the HRV and the supply ductwork system. If the floor is the only option available, then special care should be taken in locating grilles. Areas such as under baseboard heaters will help to temper the air. Also optional inline duct heaters are available for mounting in the supply duct work to add heat if required.in buildings with a forced air HVAC systems, you may want to connect the HRV to the HVAC ductwork (see information below). PRACTICAL TIPS The fresh air inlet from the HRV needs to ensure proper air mixing and temperature in the air handler. Units should be interlocked with one another so that the air handler runs, when there is a call for ventilation. Units may be operating at different static pressures. Compatibility of the two (2) systems must be verified by checking that balance of the HRV/ERV found in this manual. Direct Connection to Furnace/ Air handler return duct Should you wish to hard duct the supply air directly into the cold air return of the HVAC systems, remember to check the airflow balance of the HRV with the HVAC systems fan both on and off to determine that it does not imbalance the HRV more than 0%. Make sure you respect the minimum distance from the supply air in of the HRV/ERV and the HVAC systems (Refer to your local and National Building & Heating Codes for any variations in these notes). It may be necessary to install a separate fresh air supply ductwork system if the heating is other than forced air. When installing an HRV/ERV, the designer and installer should be aware of local codes that may require smoke detectors and/or firestats in the HVAC or HRV/ERV ductwork. Because an HRV/ERV is designed to bring fresh air into the building, structures may require supply voltage interrupt when smoke or flame sensors are triggered, or when a central fire alarm system is activated. * See installation examples found in this manual. Notes: See air handler manufacturer for appropriate specifications. 2

INSTALLING DUCTS TO / FROM INSIDE (CON T) Exhaust Air ducting The stale air exhaust system is used to draw air from the points in the building where the worst air quality problems occur. ( See installation examples in the manual.) PRACTICAL TIPS Choose the location your Supply and Exhaust Fantech grille {MGE (metal) or PGE (plastic)}s. The Exhaust Grilles should be located in areas where known contaminant's exist. A piece of flexible ducting should be placed between the HRV and the rigid ducting to absorb any noise or vibrations. Push the Fantech grille {MGE (metal) or PGE (plastic)} into the optional mounting collar or directly into installed elbow. The grilles should be installed on the ceiling or on high the wall 6 (52 mm) to 2 (305 mm) from the ceiling. Backdraft Dampers Backdraft dampers may be desired to prevent the passive migration of unwanted outside air when the HRV/ERV is set to standby or off mode. 3

INSTALLATION EXAMPLES * Drawings are illustrations only and actual port locations and airflow directions may vary, consult unit spec sheets. It is the responsibility of the installer to ensure all ductwork is sized and installed as designed to ensure the system will perform as intended. The amount of air (CFM) that an HRV/ERV will deliver is directly related to the total external static pressure (E.S.P.) of the system. Static pressure is a measure of resistance imposed on the blower by length of duct work/number of fittings used in duct work, duct heater etc. Fully Dedicated System Stale air drawn from areas of contamination Fresh air supplied to main areas HRV/ERV must be balanced External heating or cooling coil may be needed if air is not able to mix confortably. BALANCING DAMPERS SUPPLY IN EXHAUST OUT SUPPLY IN HRV UNIT Partially Dedicated System (Direct Connection) Stale air drawn from areas of contamination Fresh air supplied to return of air handler Air Handler blower may need to operate when call for ventilation HRV/ERV must be balanced AIR HANDLER UNIT RETURN AIR DUCT SUPPLY DUCT BALANCING DAMPERS SUPPLY IN EXHAUST OUT SUPPLY IN HRV UNIT EXHAUST AIR TO HRV UNIT

INSTALLATION EXAMPLES (CON'T) * Drawings are illustrations only and actual port locations and airflow directions may vary, consult unit spec sheets. It is the responsibility of the installer to ensure all ductwork is sized and installed as designed to ensure the system will perform as intended. The amount of air (CFM) that an HRV will deliver is directly related to the total external static pressure (E.S.P.) of the system. Static pressure is a measure of resistance imposed on the blower by length of duct work/number of fittings used in duct work, duct heater etc. Partially Dedicated System (Indirect Connections) Stale areas drawn from areas of contamination Fresh air supplied into ceiling return air plenum or grille HRV/ERV must be balanced AIR HANDLER UNIT 2" BREATHER SPACE CEILING RETURN AIR PLENUM SUPPLY DUCT BALANCING DAMPERS SUPPLY IN EXHAUST OUT SUPPLY IN HRV UNIT EXHAUST AIR TO HRV UNIT Simplified Installation Stale air drawn from return of air handler Fresh air supplied to return of air handler, further down stream of HRV/ERV exhaust Air Handler blower must operate when HRV/ERV is providing ventilation HRV/ERV must be balanced AIR HANDLER UNIT RETURN AIR DUCT BALANCING DAMPERS SUPPLY IN EXHAUST OUT SUPPLY IN HRV UNIT

Magnehelic AIR FLOW BALANCING PRACTICAL TIPS If the unit s airflows are not properly balanced... - The unit may not operate at it s maximum efficiency. - Heat & Energy recovery core damage may occur. - The unit s use could cause negative or positive pressure in the building causing cold air to enter or other combustible equipment to backdraft. The balancing procedure consists of measuring the exhaust air leaving the system and the supply air entering the system and ensuring that these two are equal. A deviation of 0% or less is acceptable. In such cases, it is recommended to have a greater amount of exhaust air than supply air as so to increase the supply air s temperature. A* Air Flow Pitot tube and gauge Duct Pitot Tube Magnehelic Gauge A The duct s airflow velocity is measured with a magnehelic gauge and a pitot tube. See Pitot Tube Balancing Procedure next page. To avoid airflow turbulence and incorrect readings, the airflow velocity should be measured on steel ducting a minimum of 3 duct cross-section from the unit or elbow and before any transition. - The unit may not defrost properly. PITOT TUBE BALANCING PROCEDURE PITOT TUBE BALANCING PROCEDURE The following is a method of field balancing an HRV/ERV using a Pitot tube, advantageous in situations when flow stations are not installed in the ductwork. Procedure should be performed with the HRV/ERV on high speed. The first step is to operate all mechanical systems on high speed, which have an influence on the ventilation system, i.e. the HRV/ERV itself and the forced air HVAC system or air handler if applicable. This will provide the maximum pressure that the HRV/ERV will need to overcome, and allow for a more accurate balance of the unit. Drill a small hole in the duct (about 3/6"), four feet downstream of any elbows or bends, and two feet upstream of any elbows or bends. These are recommended distances but the actual installation may limit the amount of straight duct. The Pitot tube should be connected to a magnehelic gauge or other manometer capable of reading from 0 to 0.25 in (0-62 Pa) of water, preferably to 3 digits of resolution. The tube coming out of the top of the pitot is connected to the high pressure side of the gauge. The tube coming out of the side of the pitot is connected to the low pressure or reference side of the gauge. 6 Insert the Pitot tube into the duct; pointing the tip into the airflow. For general balancing it is sufficient to move the pitot tube around in the duct and take an average or typical reading. Repeat this procedure in the other (supply or return) duct. Determine which duct has the highest airflow (highest reading on the gauge). Then damper that airflow back to match the lower reading from the other duct. The flows should now be balanced. Actual airflow can be determined from the gauge reading. The value read on the gauge is called the velocity pressure. The Pitot tube comes with a chart that will give the air flow velocity based on the velocity pressure indicated by the gauge. This velocity will be in either feet per minute or meters per second. To determine the actual airflow, the velocity is multiplied by the cross sectional areas of the duct being measured. The accuracy of the air flow reading will be affected by how close to any elbows or bends the readings are taken. Accuracy can be increased by taking an average of multiple readings as outlined in the literature supplied with the Pitot tube.

MAINTENANCE CAUTION MAKE SURE UNIT IS UNPLUGGED BEFORE ATTEMPTING ANY MAINTENANCE WORK The following components should also be inspected regularly and well maintained. PRACTICAL TIPS To prevent electrical shock, check that the unit is unplugged before doing any repairs or maintenance. A yearly inspection is recommended to ensure the efficiency and trouble-free use of your system. Run through the system and verify the different operating modes. The motor - The motors are factory balanced and lubricated for life. They require no maintenance. FILTERS The filters need to be checked and cleaned once a month or when they appear dirty. FIXED PLATE HRV-XI 450 (Polypropylene Core) Wash OK & ERV-XI 450 (Enthalpy Core) Vacuum Only Clean core on a average every 3-6 months. a) Open access door & remove filters. b) Carefully grip ends of core and pull evenly outward. Core may be snug, but will slide out of the channel. c) Vacuum only ERV-XI 450 core (do not wash). d) Wash HRV-XI 450 core in warm soapy water. e) Install clean core f) Install the clean filters g) Replace access door Note: Core installation label on the outer end of the core. To install the clean Core and Filters. a) first mount the bottom flange of the core guide into the bottom channel approximately /4 (6mm) b) mount the left or right side flange of the core guide approximately /4 (6mm) followed by the other side c) mount the top flange of the core guide into the top channel approximately /4 (6mm) d) with all four corners in place and the core straight and even, push hard in the centre of the core until the core stops on the back of the cabinet. The unit - The inside of the unit should be vacuumed yearly. Be careful not to damage any of the mechanical components and electrical connections. Condensation Panel - The condensation panel should be cleaned yearly or as needed. The drain and drain line - Units with drain hoses should have their line and connection checked regularly. Outside hoods - The outside hoods need to be checked every season to make sure there are no leaves or insects blocking the airflow. Check regularly that there are no pollutants near the intake hood. Make sure they are clear of any snow accumulation during the winter months. WHEEL ERV-WI 500 (Enthalpic Wheel) Wash OK Seals The seals are designed to be durable and require no maintenance other than adjustment, but if seals become worn or damaged they may easily be replaced. The seals are made to clip on the cassette or post metal easily. Wheel The wheel is somewhat self cleaning through its normal action of rotating in and out of countercurrent airflow streams.. If the wheel becomes dirty, it may be cleaned by blowing out the unit with compressed air (20 psig maximum). In cases of severe uncleanliness, the wheel may be removed from the cassette and washed with water following wheel removable procedures outlined below:. Open ERV-WI 500 access door so that the front or back of the cassette may be easily accessed. 2. Support the wheel from the bottom 3. If the unit is equipped with an internal bearing, unbolt the shaft screw on both sides of the shaft. Unbolt one post completely and remove post. Remove the shaft clips at the face of the hub from both sides of the shaft. Remove the shaft. Roll the wheel out carefully. 4. With the wheel out, wash the media carefully with water. Once clean, allow the media to dry out for several hours or days if necessary. 5. Reinstall using the reverse procedure. Run the unit. It may take several hours for the desiccant to dry out and for the wheel to perform normally. 7

WIRING DIAGRAM HRV-XI 450 LIVE TB TB TB4-TB6 Red TB8-TB0 Red White TB4-TB6 White TB8-TB0 FU REMOTE CONTROL TB TB 2 R (EXHAUST) 3 COM R2 (SUPPLY) COM 3 R3 (DEFROST) COM 3 R4 COM 3 2 2 2 2 GROUND 20VAC 24VAC NC NO TB3 NC 5 4 5 NO TB7 NC NO TB3 4 5 4 NC NO 5 4 POWER CORD 20 VAC Blue Black Red Defrost Timer White Yellow Black CLIX-ON or THERMISTOR 24VAC FOR AQS 6 (Green) EXHAUST (White) 2 (Red) 3 (Grey) 4 (Black) TB6 TB5 TB4 TB3 TB0 TB9 TB8 TB7 (White) 2 (Red) 3 (Grey) 4 (Black) SUPPLY 6 (Green) 5 (Blue) 5 (Blue) NEUTRAL TB2 TB2 TB2 WIRING DIAGRAM ERV-XI 450 LIVE TB TB FU REMOTE CONTROL TB TB 2 R R2 (EXHAUST) (SUPPLY) 3 3 COM COM 2 2 GROUND 20VAC 24VAC NC 5 NO TB3 NC NO TB7 4 5 4 POWER CORD 20 VAC TB4-TB6 Red TB8-TB0 Red White TB4-TB6 White TB8-TB0 24VAC FOR AQS 6 (Green) EXHAUST (White) 2 (Red) 3 (Grey) 4 (Black) TB6 TB5 TB4 TB3 TB0 TB9 TB8 TB7 (White) 2 (Red) 3 (Grey) 4 (Black) SUPPLY 6 (Green) 5 (Blue) 5 (Blue) 8 NEUTRAL TB2 TB2 TB2

WIRING DIAGRAM ERV-WI 500 LINE TB TB3 TB5 & TB6 Internal low voltage contacts for remote control option TB5 TB6 R 3 R2 3 R3 4 24 VAC 2 5 4 2 5 4 5 8 9 2 3 4 FU GROUND TB7 TB9 TB8 SPEED CONTROL (OPTIONAL) TB0 SPEED CONTROL (OPTIONAL) POWER CORD 20 VAC MOTOR WHEEL Brown Brown MOTOR EXHAUST Black MOTOR SUPPLY Black Blue Blue NEUTRAL TB2 TB4 TB4 9

Technical support hotline.800.565.3548 United States 72 Northgate Blvd. Sarasota, Fl. USA 34234 (T).800.747.762 (F).800.487.995 (T).94.309.6000 (F).94.309.6099 Ontario & Western Canada 0-6665 Tomken Road Mississauga, Ontario Canada L5T 2C4 (T).800.407.695 (F).800.407.8965 (T).905.696.9235 (F).905.696.9236 Québec & Atlantic Provinces 50 Kanalflakt Way Bouctouche, NB, Canada E4S 3M5 (T).800.565.3548 (F).877.747.86 (T).506.743.9500 (F).506.743.9600 www.fantech.net info@fantech.net Manufactured by: ISO 900 Article #: 30025 Rev Date: 02203